Présentation du produit & Répartition du modèle
C125N420FM is a 4‑pole molded case circuit breaker from Schneider Electric’s ComPacT NS1250N series, equipped with a MicroLogic 2.0 control unit.
It is used for overload and short‑circuit protection in low‑voltage power distribution systems, widely applied in industrial plants, bâtiments commerciaux, and infrastructure projects.
| Segment de modèle | Description |
| C125N | ComPacT NS1250N series, frame size 1250A, breaking capacity 50kA@415VAC |
| 4 | 4‑pole configuration (4P.) |
| 20 | MicroLogique 2.0 control unit (fonctions de protection de base) |
| FM | Fixed mount, manual operation, front connection |
- Spécifications techniques de base
| Article | Valeur | Remarques |
| Modèle | Schneider Electric C125N420FM | Full description: ComPacT NS1250N 4P 1250A 50kA MIC2.0 |
| Frame current | 1250UN | Maximum rated operational current |
| Poteaux | 4 poteaux (4P.) | 3 étapes + protection neutre |
| Trip unit | MicroLogique 2.0 | Long‑time (L), short‑time (S), instantané (je) protection |
| Courant nominal (Ir) | 1250UN | Adjustable via trip unit |
| Pouvoir de coupure ultime (ICU) | 50kA@415VAC | Complies with IEC 60947‑2 |
| Montage | Fixé, front connection | Suitable for standard switchgear |
| Opération | Manuel | With mechanical indication and lockability |
| Tension d'isolement nominale (Interface utilisateur) | 1000ACC | CEI 60947‑2 |
| Tension de fonctionnement nominale (Ue) | 400/415ACC (50Hz) | Standard 3‑phase voltage |
| Short‑time withstand current (Icw/1s) | 50le | Ensures system stability during faults |
| Degré de protection | IP30 | Protection against solid foreign objects |
| Capacité de câblage | Max.. 300mm² cuivre | For high‑current loads |
- Caractéristiques & Avantages
- Protection complète
MicroLogique 2.0 provides 3‑stage protection (L‑S‑I) with adjustable settings.
Supports fault diagnostics and alarm output for easy maintenance.
- Efficient design
Green “T” design reduces panel wiring time by 40%.
Ergonomic operating handle for improved safety and comfort.
Modular structure supports accessories: contacts auxiliaires, contacts d'alarme, déclencheur à minimum de tension, etc..
- Reliable performance
50kA high breaking capacity for fast fault interruption.
Durée de vie mécanique: jusqu'à 10,000 opérations; electrical life: jusqu'à 5,000 opérations.
Température ambiante: −5°C to +40°C (full rating), −25°C to +70°C (derated).
- Installation & Applications
4.1 Exigences d'installation
Suitable for standard distribution boards with industry‑standard mounting depth.
Front connection for easy wiring and maintenance.
Sufficient heat dissipation space required for stable long‑term operation.
4.2 Applications typiques
Incoming protection for main power distribution boards in industrial plants
Power distribution systems for large commercial complexes
UPS input/output protection in data centers
Critical load protection in infrastructure (hôpitaux, aéroports, metros)
Main protection for Motor Control Centers (Centre multicompte)
- Related Models & Alternatives
5.1 Derived models in the same series
| Modèle | Différence | Application |
| C125N320FM | 3 poteaux (3P.) | 3‑phase loads without neutral protection |
| C125N450FM | MicroLogique 5.0 déclencheur | Energy measurement and advanced protection |
| C125N420PM | Draw‑out installation | Easy maintenance without power interruption |
| C125N420RM | Plug‑in installation | Fast replacement for backup equipment |
5.2 Cross‑series alternatives
| Remplacement | Série | Main difference | Price reference |
| NSX1250N 4P MIC2.0 | ComPacT NSX | New generation, pouvoir de coupure 65kA | Environ. +10% |
| Masterpact MTZ12 | Masterpact MTZ | Air circuit breaker for higher power systems | Environ. +50% |
5.3 Competitive brand equivalents
| Marque | Remplacement | Notation |
| Siemens | 3WL1212‑3CB36‑4GA4 | 1250A 4P 50kA basic protection |
| ABB | Tmax T6H1250 PR221DS‑LSI 4P | 1250A 4P 50kA LSI protection |
| Eaton | NZM4‑1250N 4P | 1250A 4P 50kA basic protection |
- Achat & Conseils d'utilisation
- Authentic procurement: Purchase via authorized Schneider Electric distributors or official channels to ensure quality and service.
- Accessoires: Optional auxiliary contacts, contacts d'alarme, voyage de dérivation, déclencheur à minimum de tension, etc..
- Paramétrage: MicroLogique 2.0 can be programmed; adjust according to load characteristics.
- Entretien: Routine inspection every 1–2 years, including mechanism, bornes, et fonctions de protection.
> Note: C125N420FM complies with IEC 60947‑2, FR 14048.2 and other international & national standards. It is fully compatible with Schneider Prisma E, Blokset and other panel systems.
- Sélection & Directives de remplacement
- Compatibility Rules
Industrial relay sockets follow international standard dimensions and are interchangeable across brands if:
Pin count matches relay pole number
Courant nominal (≥10A) meets load
Montage (DIN-rail/screw) matches panel design
- Terminal Type Selection
Conventional screw: PTF08A / PTF11A / PTF14A-suitable for low-vibration environments
Finger protection: PTFZ series-suitable for areas with frequent access
Push-In Plus: PTF-PU series-ideal for mass wiring, high vibration resistance
- Modèles abandonnés
PTF08A-E / PTF14A-E are discontinued with limited stock.
Use PTFZ series as the preferred replacement.
> Note: PTF series sockets are rated 10A/250VAC, dielectric strength AC 2000V, operating temp −25 °C to +55 °C, suitable for 0.5–2.5 mm² copper wires.
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires