ABB MCCB T6V 800 PR221DS

T6V 800 PR221DS|ABB Tmax T6 Series High Performance Moulded Case Circuit Breaker (MCCB)

Modello completo: T6V 800 PR221DS-LS/I In=800 (Common Order Codes: 1SDA069432R1, 1SDA069429R1, 3P/4P selectable)

Marca: ABB (SACE Tmax Series)

  1. Detailed Model Interpretation
Segmento modelloSensoKey Description
T6Series DesignationTmax T6 series, frame current 800A, suitable for medium and high voltage power distribution systems
VClasse del potere di interruzioneClass V, ultra-high breaking capacity: 120kA at 400V, 200kA at 220V
800Corrente nominale800UN (same as frame current)
PR221DSTipo di unità di sgancioElectronic intelligent trip unit with LS/I protection (Long-time delay L, Short-time delay S, Istantaneo I)
LS/IConfigurazione della protezioneStandard three-stage protection; earth fault protection optional (extra configuration required)
F FMontaggio / ConnessioneFirst F: Montaggio fisso; Second F: Collegamento frontale
  1. Parametri tecnici fondamentali
ArticoloSpecificaOsservazioni
Tensione nominale (Ue)690V eSuitable for industrial high-voltage power distribution systems
Tensione di isolamento nominale (Ui)1000V eHigher than rated operating voltage, large safety margin
Ultimate Breaking Capacity (terapia intensiva)120kA@400V, 200kA@220VHighest Class V, adatto per ambienti industriali difficili
Corrente operativa nominale (In)800UNMaximum continuous operating current
Poli3P/4P selectable3P for three-phase circuits, 4P includes neutral protection
Caratteristica del viaggioLS/I three-stage protectionLong-time delay inverse time, short-time / instantaneous definite time
Tipo di montaggioFissoDraw-out type also available (special model required)
Tipo di connessioneCollegamento frontaleCompatible with cables or busbars
Grado di protezioneIP30Standard switchgear installation protection
Applicable StandardCEI 60947-2International standard for low-voltage switchgear
  1. Caratteristiche principali & Applicazioni

Vantaggi fondamentali

  1. Ultra-high breaking capacity: Class V can withstand severe short-circuit faults and ensure system safety
  2. Intelligent protection: PR221DS trip unit provides accurate overload and short-circuit protection with adjustable parameters
  3. Reliable and durable: ABB Tmax series design, suitable for frequent operation and harsh industrial environments
  4. Flexible extension: Supporta vari accessori (contatti ausiliari, alarm contacts, sganciatore di minima tensione, ecc.)

Applicazioni tipiche

Main power distribution systems in large industrial plants

690V high-voltage Motor Control Centers (Centro clienti)

Power supply for data centers and critical infrastructure

Combiner box protection for new energy power systems (PV, wind power)

Marine and offshore platform power distribution systems

  1. Reference Replacement Models

Same-brand Upgrades / Replacements

ModelloCapacità di interruzioneTipo di viaggioApplicazione
T6V 800 PR222DS-LSIG120kA@400VWith earth fault protection (G)Systems requiring earth fault detection
T6V 800 PR223DS120kA@400VAdvanced intelligent trip unitApplications requiring remote monitoring and communication
T6S 800 PR221DS70kA@400VStandard breaking capacityGeneral industrial power distribution, costo inferiore

Cross-brand Alternatives

MarcaModelloParametri di corrispondenza chiave
SchneiderMasterpact MT25H1 800A800UN, 120kA breaking, three-stage protection
Siemens3WL1210-3BB36-4GA4800UN, 100kA breaking, intelligent trip unit
MitsubishiNF800-SEW800UN, 100kA breaking, electronic trip unit
  1. Note sulla selezione
  2. Breaking capacity matching: Select V/S/H/N/L classes based on system short-circuit current calculation
  3. Protection function selection: Basic LS/I meets most needs; choose LSIG for earth fault protection
  4. Mounting type: Fixed for standard switchgear, draw-out for easy maintenance and replacement
  5. Accessory configuration: Select auxiliary contacts, alarm contacts, motor operators, ecc., according to control requirements
  6. Voltage compatibility: T6V suitable for systems up to 690V; use dedicated 1000V series (per esempio., T6L) for higher voltages