Sensore di livello conduttivo Carlo Gavazzi 481046 - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Sensore di livello conduttivo Carlo Gavazzi 481046 - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

NotiziaNotizie commerciali

Sensore di livello conduttivo Carlo Gavazzi 481046

Carlo Gavazzi VNY 4 NS/NT Conductive Level Sensor (Item No.: 481046)

Carlo Gavazzi VNY 4 NS/NT Conductive Level Sensor (Item No.: 481046)

Segmento modelloDescrizione
VNYSerie di prodotti: Conductive level probe; VNY series features threaded connection with PBTP housing and non-insulated electrodes
4Electrode quantity: 4 electrodes, supporting multi-level monitoring (Alto / Medio / Basso / Ultra-low)
NSElectrode type: Non-Isolated, suitable for general conductive liquid measurement
NTTipo di connessione: Morsetti a vite, convenient for field wiring
481046Global unique item / numero dell'ordine, official Carlo Gavazzi part identifier
  1. Full Core Technical Specifications
Categoria dei parametriSpecificheOsservazioni
Informazioni di baseConductive level sensor for multi-point level control of conductive liquidsMust be used with amplifier relays (SV series, S195/196, ELA/ELC/ELD)
Ordine n.481046 (corresponds to model VNY 4 NS/NT)Order strictly by this part number
ProduttoreCarlo GavazziWell-known brand in industrial automation sensors
Electrode Configuration4 non-insulated electrodes, AISI316 stainless steel (DIN1.4401)Diameter 5mm, standard length 100cm (field-cuttable)
Materiale dell'alloggiamentoPBTP engineering plasticCorrosion-resistant for industrial environments
Tipo di montaggio1 1/2″ pipe thread (ISO 228/1-G1 1/2″)Standard industrial pipeline mounting, fixed with VM15 nut
Metodo di connessioneScrew terminal connection (NT)More suitable for vibrating environments than cable connection, facile manutenzione
Protezione dall'ingressoIP67Dust-tight and waterproof, submersible in liquid
Temperatura operativa0°C ~ 90°C (32°F ~ 194°F)Compatible with most industrial liquid temperature ranges
Temperatura di conservazione-25°C ~ 100°C (-13°F ~ 212°F)Adaptable to extreme transportation and storage conditions
Pressione di esercizio10 sbarra (@ 60°C)Suitable for medium and high-pressure tank applications
Specifiche del cavoNo built-in cable (screw terminal type)Customer-supplied cable recommended; shielded cable preferred to reduce interference
CertificazioniCertificato CE (conforme alla CEI 529)Meets EU industrial safety requirements
DimensioniElectrode diameter 5mm, total length approx. 100cmElectrode length can be cut on-site according to actual liquid level
Pesoca. 0.8kgLightweight design for easy installation and maintenance
  1. VNY Series Full Model List
Item No.ModelloElectrode QtyElectrode TypeTipo di connessioneMateriale dell'alloggiamentoMounting ThreadCaratteristiche speciali
481046VNY 4 NS/NT4Non-Isolated (NS)Screw Terminal (NT)PBTP1 1/2″Multi-level control, general industrial use
481043VNY 1 NS/NT1Non-Isolated (NS)Screw Terminal (NT)PBTP1 1/2″Single-point level detection, conveniente
481044VNY 2 NS/NT2Non-Isolated (NS)Screw Terminal (NT)PBTP1 1/2″Two-point high/low level control
481045VNY 3 NS/NT3Non-Isolated (NS)Screw Terminal (NT)PBTP1 1/2″Three-point high/medium/low level control
481047VNYI 4 IS/NT4Insulated (IS)Screw Terminal (NT)PBTP1 1/2″PE insulated electrodes, anti-clinging liquid interference
481042VNY 1 NS/CB1Non-Isolated (NS)Connessione via cavo (CB)PBTP1 1/2″2m fixed cable length, suitable for long-distance installation
  1. Sostituzione & Cross Reference

4.1 Same Brand Direct Replacement

Modello originaleModello sostitutivoReplacement DescriptionScenario applicativo
VNY 4 NS/NT (481046)VNYI 4 IS/NTUpgraded insulated electrodes to avoid false triggering from liquid clingingViscous liquids and wall-adhering media (syrup, lubricating oil)
VNY 4 NS/NT (481046)VNY 4 NS/CBChanged to cable connection for heavy vibration environmentsLevel monitoring for vibrating equipment such as pump sets and compressors
VNY 4 NS/NT (481046)VN 4 NS/CBCable type with PBTP housing and 1 1/2″ filoGeneral industrial environments, better cost performance

4.2 Cross-Brand Equivalent Models

Carlo GavazziSchneiderOmronPepperl+FuchsPrincipali differenze
VNY 4 NS/NT (481046)XPSAK3711D4CC-4000FTL20-0020Carlo Gavazzi adopts superior AISI316 material with IP67 protection
Schneider higher integration; Omron more cost-competitive
Field-cuttable electrode length for better adaptability
Pepperl+Fuchs suitable for explosion-proof areas; Carlo Gavazzi for general industry
  1. Application Industries & Casi tipici

Applicazioni consigliate

  1. Process Industry: Tank level monitoring in chemical, petrochemical and pharmaceutical industries to prevent overflow and dry running
  2. Cibo & Bevanda: Raw material and finished tank level control for beer, beverage and dairy production lines
  3. Trattamento delle acque: Level monitoring for sedimentation tanks and reaction tanks in waterworks and wastewater plants
  4. Energy Sector: Level protection for cooling and lubrication systems in power plants and substations
  5. Mechanical Manufacturing: Oil level monitoring for hydraulic and lubrication systems to avoid equipment damage
  6. Industria marina: Level measurement for ship ballast tanks, fuel tanks and fresh water tanks

 

Casi applicativi tipici

  1. Chemical Plant Acid & Alkali Tank Level Control System

Application Goal: Monitor high/low levels of three 100m³ acid and alkali tanks to prevent overflow and pump dry running

Vantaggi fondamentali: AISI316 corrosion-resistant electrodes; IP67 suitable for outdoor installation; 4-electrode enables multi-point level monitoring

System Configuration: VNY 4 NS/NT (481046) × 3 + ELA amplifier relay + PLC control system + HMI touch screen

Operation Effect: Level control accuracy ±1cm, false alarm rate reduced by 95%, maintenance cost cut by 60%

 

  1. Automobile Factory Hydraulic Station Oil Level Monitoring System

Application Goal: Monitor oil levels of 5 hydraulic stations to ensure stable operation and prevent oil shortage failure

Vantaggi fondamentali: Vibration-resistant screw terminal design; oil-resistant PBTP housing; field-cuttable electrodes adaptable to various tank heights

System Configuration: VNY 4 NS/NT (481046) × 5 + S196 amplifier + indicatore luminoso + cicalino

Operation Effect: Equipment failure rate reduced by 40%, maintenance cycle doubled

Not Recommended Applications

Non-conductive liquids: Such as pure oil, alcohol, acetone; not detectable by conductive sensors

Alta temperatura >90°C: Adopt VPP series (up to 100°C) or high-temperature versions

Working pressure >10 sbarra: Special high-pressure level sensor required

Strong corrosive media: Concentrated hydrochloric acid, concentrated sulfuric acid; use VPP series with PVDF electrodes or anti-corrosion coated models

  1. Installazione & Linee guida per il cablaggio

Requisiti di installazione

  1. Posizione di montaggio: Install on tank top or side, away from inlet ports and agitators; ensure vertical electrode immersion
  2. Electrode Cutting: Cut electrode length on-site according to actual liquid level; deburr the end after cutting for accuracy
  3. Sigillatura: Use suitable gaskets (PTFE recommended) for leak-tight installation to maintain IP67 protection
  4. Earthing Requirement: Conductive tank body can serve as common electrode; non-conductive tanks require separate common electrode grounding
  5. Spacing Requirement: Keep ≥50mm between electrodes and between electrodes and tank wall to avoid signal interference

Core Terminal Definition

Terminal No.FunzioneTipoOsservazioni
E1/E2/E3/E4Electrode 1–4Signal InputCorrespond to four level detection points; freely assign high/medium/low functions
COMTerminale comuneSignal ReferenceConnect to tank wall or separate common electrode to complete circuit
+V/-VAlimentazione elettrica24VCCRequires matching amplifier relay; sensor itself needs no independent power supply
NO/NC/COMUscita relèSwitch ContactProvided by amplifier relay for valve control or alarm output

Punti chiave della messa in servizio

  1. Electrode Setting: Define corresponding level heights for each electrode (per esempio. E1=Low, E2=Medium, E3=High, E4=Ultra-high)
  2. Sensitivity Adjustment: Adjust amplifier relay sensitivity to avoid false triggering caused by foam or clinging liquid
  3. Prova di funzionalità: Simulate level changes to verify accurate switching action and response time
  4. Insulation Check: For non-insulated type, ensure no short circuit between electrodes and tank wall; check insulation integrity for insulated type
  5. Environmental Adaptation Test: Verify long-term stability within rated temperature and pressure range
  6. Regole di selezione & Quick Reference

Linee guida per la selezione

  1. Liquid Type: Choose VNY series for conductive liquids; use capacitive or ultrasonic sensors for non-conductive liquids
  2. Electrode Quantity: 1=single point, 2=high/low, 3=high/medium/low, 4=four-point full control
  3. Electrode Insulation: NS for normal liquids; IS insulated type for viscous wall-adhering media
  4. Tipo di connessione: NT screw terminal for vibration environments; CB cable type for long-distance installation
  5. Mounting Thread: 1 1/2″ for large tanks, 1″ for medium, 1/2″ for small containers
  6. Temperatura & Pressione: VNY for 0–90°C / 10 sbarra; VPP for higher temperature; special models for higher pressure
  7. Air Freight Compliance & Certificazioni

Air Freight Compliance: No lithium battery / supercapacitor. Pure mechanical and metallic structure, compliant with IATA DGR Class 9, shippable as standard general cargo.

Certificazioni:

– CE: Conforme alla norma CEI 529 ingress protection standard

– RoHS: EU RoHS compliant, free of hazardous heavy metals

Material Certification: AISI316 stainless steel electrodes meet food-contact grade requirements for food & beverage industry

Conformità ambientale: Compliant with REACH regulations for global market access

  1. Acquisto & Informazioni logistiche
Purchase ItemDettagli
MOQ1 unità
Tempi di consegnaStandard 5–7 days; Express 2–3 days
ConfezioneIndividual carton with installation manual, sealing gasket and mounting nut
Garanzia12 months from commissioning acceptance
Recommended SparesSame model sensor, electrode extension joint (VD1), mounting nut (VM15)
Accessori coordinatiCarlo Gavazzi ELA/ELC/ELD amplifier relay, PLC, HMI touch screen

Prec:

Lascia una risposta