ABB 2UEA001345 Phase Module Kit

ABB 2UEA001345 (ACS 2040-PMK1000) 4kV Phase Module Kit

ABB 2UEA001345 is a dedicated phase module kit for ACS 2040 series 4kV medium-voltage frequency converters. It serves as the core power unit of the ACS2000 medium-voltage drive system, adopting 3-level IGBT topology. It is applicable to 4kV power grid systems with rated power ranging from 300-1000HP (225-750kW).

Its core strengths include high-reliability design (MTBF>100,000 hours), low harmonic output (compliant with IEEE 519 standard), modular structure for easy maintenance and replacement, and wide operating temperature range (-10℃ ~ +40 ℃). It is perfectly suited for general industrial loads such as fans, pompe e compressori dell'acqua, which can effectively improve system energy efficiency (20%-40% risparmio energetico) and reduce maintenance costs.

  1. Spiegazione del codice modello
SezioneCodiceDefinizione
Serie di prodotti2UEASeries code for ABB medium-voltage inverter power modules (2UEA=ACS 2040 serie, 2UEB=ACS 2000 serie)
Part Number1345Unique identification code of phase module kit, corresponding to model ACS 2040-PMK1000
Applicable Voltage4kVMatches 4000V medium-voltage power grid system
Tipo di prodottoPMK1000Phase Module Kit, corrente nominale: 1000UN
Sistema applicabileACS 2040Compatible with ABB ACS 2040 series medium-voltage inverters

Numero d'ordine: 2UEA001345 (Standard single packing)

Modello corrispondente: 2UEA001141 (Complementary phase module of the same series)

  1. Main Technical Specifications
CategoriaArticoloParametroOsservazioni
Informazioni di baseTipo di prodotto4kV Medium Voltage Inverter Phase Module Kit3-level IGBT topology, integrated drive and protection circuits
Applicable InverterACS 2040 Serie (ACS2000 Platform)Compatible with Frame 1 misurare (300-1000HP)
Tensione nominale4kV (4000V)Intervallo di tensione operativa: 3.6~4.4kV
Corrente nominale1000UNMax peak current: 2000UN (2 times rated value)
Power DevicesIGBT TypeHigh-voltage IGBT Module1700V/1200A, ABB customized version
Topology3-level NPC (Neutral Point Clamped)Reduce dv/dt and motor insulation stress
Cooling ModeRaffreddamento ad aria forzataVentola di raffreddamento incorporata, redundant design supported
Parametri ElettriciFrequenza di ingresso50/60Hz, ±5%Compatible with global power grid standards
Switching Frequency2~8kHz (Regolabile)Balance energy efficiency and noise performance
Power Lossca. 1.2kW per moduleUnder typical working conditions
Classe di isolamentoOvervoltage Category IV (CEI 60664)Meet insulation requirements of medium-voltage systems
Parametri meccaniciDimensione (L×L×A)650×450×320mmStandard Frame 1 misurare
Peso netto48.5kgExcluding packaging
Classe di protezioneIP20Adatto per installazione in armadio
Funzioni di protezioneProtezione da sovracorrente2000UN (2 times rated)Short-circuit response time <10μs
Protezione da sovratensione4.4kVDC bus overvoltage protection
Over-temperature Protection100℃IGBT module overtemperature protection
Protezione da sottotensione3.6kVGrid undervoltage protection
Certificazioni & ConformitàCE CertificateConforme alla norma EN 61800-5-1
UL CertificateMeet North American medium-voltage equipment standards
IEEE 519 ConformitàTotal harmonic distortion <5%
  1. Full Model List of ACS 2040 Series Phase Modules
ModelloOrdine n.Tensione nominaleCorrente nominaleApplicable InverterNote
ACS 2040-PMK10002UEA0013454kV1000UNACS 2040 Telaio 1Standard phase module
ACS 2040-PMK10002UEA0011414kV1000UNACS 2040 Telaio 1Complementary phase module
ACS 2040-PMK12002UEA0013464kV1200UNACS 2040 Telaio 1High current version
ACS 2040-PMK8002UEA0013474kV800UNACS 2040 Telaio 1Low current version
ACS 2040-PMK1000-6kV2UEA0013486kV1000UNACS 2040 Telaio 26kV dedicated version
  1. Sostituzione & Equivalent Models

4.1 Internal ABB Replacement

Old ModelNew ModelReplacement Description
ACS 1040-PMK1000ACS 2040-PMK1000 (2UEA001345)Upgraded to 3-level topology, efficiency increased by 2%, harmonic distortion reduced by 30%
ACS 2040-PMK800 (2UEA001347)ACS 2040-PMK1000 (2UEA001345)Higher current model in the same series, wider power coverage

4.2 Cross-brand Equivalent Products

MarcaModello equivalenteVantaggi
SiemensSINAMICS GM150 Power ModuleSuperior 3-level topology, lower dv/dt, better motor insulation protection
Schneider ElectricAltivar 6100 Medium Voltage ModuleEasier maintenance with modular design, higher MTBF (>100,000 hours)
Mitsubishi ElectricMV-VFD Power ModuleWider applicable voltage range (3.6-4.4kV), stronger environmental adaptability
  1. Scenari applicativi & Industry Cases

5.1 Applicazioni consigliate

Tipo di applicazioneTypical Working ConditionsVantaggi fondamentali
Industrial FansPower plant induced draft fans, cement plant kiln fans, steel plant dust removal fansWide speed regulation range (0.1-100Hz), 30%-40% risparmio energetico
Industrial Water PumpsWater plant high-pressure water supply pumps, mine drainage pumps, petrochemical circulating pumpsSoft start without impact, reduce pipeline stress and extend service life
CompressoriCompressori d'aria, natural gas compressors, compressori frigoriferiPrecise pressure control, reduce no-load loss and improve energy efficiency
TrasportatoriLong-distance mine conveyors, port container conveyorsSmooth speed regulation, avoid material accumulation and mechanical wear
General Industrial EquipmentMiscelatori, frantoi, estrusori, ecc.Modular design for convenient maintenance, MTBF>100,000 hours

5.2 Not Recommended Usage Scenarios

Aree a prova di esplosione (non-explosion-proof structure, customized version required)

Offshore platforms (additional anti-corrosion treatment needed)

Ultra-high voltage systems above 4.4kV (select 6kV version instead)

Equipment with frequent start-stop operations (più di 10 volte all'ora, special customized modules recommended)

5.3 Practical Cases

Caso 1: Induced Draft Fan Renovation in Thermal Power Plant

Original system: Fixed-speed motor + baffle adjustment, high energy consumption and severe baffle wear

Renovation solution: ACS 2040 inverter + 3 sets of 2UEA001345 phase modules (3-fase)

Effect: Energy consumption reduced by 38%, annual electricity cost saved about 1.8 million RMB, baffle maintenance cycle extended 5 volte

Caso 2: High-pressure Water Supply System for Large Water Plant

Richiesta: Constant pressure water supply with large load fluctuation (20%-100%)

Soluzione: ACS 2040 Telaio 1 (3 pcs 2UEA001345 modules) + PID control system

Effect: Stable pressure deviation within ±0.05MPa, 32% risparmio energetico, service life extended by 3 anni

  1. Air Shipment Compliance & Certification Guide

6.1 Shipment Compliance Confirmation

ArticoloStatoSpiegazione
Built-in Lithium BatteryNOOnly electronic components and IGBT modules equipped
Dangerous Goods ClassificationNon-dangerous goodsCompliant with IATA DGR Class 9, no special shipping restrictions
Transport RestrictionsNessunoCan be shipped as ordinary industrial equipment
Packaging StandardStandard shockproof packageFix IGBT modules firmly to avoid damage during transit
Intervallo di temperatura-20℃ ~ +50℃Avoid extreme temperature during transportation

6.2 Certification Document Acquisition

CE Certificate: Available for download on official ABB website (Document ID: ACS2000-PHTC01U-EN)

UL Certificate: Apply via ABB global technical support center

Manufacturer Declaration: Including EMC, safety and RoHS compliance statements

  1. Linee guida per la selezione & Quick Rules

Regole di selezione

  1. Corrispondenza della tensione: 2UEA001345 for 4kV systems; choose 2UEA001348 for 6kV systems
  2. Current Selection: 1000A standard (PMK1000), 800A low current (PMK800), 1200Una corrente elevata (PMK1200)
  3. Compatibilità del sistema: Only applicable to ACS 2040 serie (ACS2000 platform) Telaio 1 misurare
  4. Quantity Matching: 3 phase modules required for one 3-phase inverter, 1 spare module is recommended
  5. Suggerimenti per la manutenzione: Regularly inspect cooling fans, replace IGBT modules every 5 years to ensure stable insulation performance
  6. Main Accessories & Configurazione consigliata
Nome dell'accessorioModelloFunzione
Unità di controlloACS 2040-CUCore control unit matched with phase modules
Cooling Fan3HAC031683-001Special cooling fan for phase modules, support redundant operation
Drive Board3HAC031684-001IGBT drive circuit with integrated protection functions
Voltage Sensor3HAC031685-0014kV system voltage monitoring, realize over/under voltage protection
Current Sensor3HAC031686-0011000A current detection, sovracorrente & protezione da cortocircuito
Installation Kit3HAC031687-001Including fixing bolts, gaskets, insulating sleeves etc.