CX-75A belongs to the CX Turbo Medium-pressure Centrifugal Blower, comunemente noto come turboventilatore a media pressione. I marchi popolari includono Eurostandard, Vento pieno, MANVAC, ecc. Si tratta di un ventilatore in lega di alluminio ad accoppiamento diretto standard del settore con potenza nominale di 0,75 kW (1HP).
✅ Specifiche chiave (50Hz Standard)
Potenza nominale: 0.75 kW / 750W (1HP)
Alimentazione elettrica: Monofase 220V / Three-phase 380V optional
Flusso d'aria: 13 m3/min (780 m³/h); fino a 15 m³/min at 60Hz
Max Positive Pressure: 2.4 kPa (2400 mmH₂O)
Max Negative Pressure: 1.7 kPa (1700 mmH₂O)
Ingresso & Presa: Inlet 125mm, Outlet 100mm
Materiale: Die-cast aluminum alloy housing + aluminum impeller, azionamento diretto, no belt
Classe di protezione: IP54/IP55, Isolamento di classe F
Livello di rumore: 64~80dB(UN)
Peso netto: ca. 14~17kg (varies slightly by manufacturer)
✅ Structural Features
- Turbo structure, medium pressure with large air volume, different from high-pressure ring blowers.
- Motor and impeller are coaxial direct-coupled, dimensioni compatte, belt-free maintenance.
- Full die-cast aluminum, lightweight with good heat dissipation; suitable for long continuous operation.
- Sealed maintenance-free bearings, manutenzione ridotta in condizioni di lavoro normali.
✅ Applicazioni tipiche
Ventilatore di combustione per bruciatori, asciugatura ad aria calda, circolazione dell'aria calda nei forni
Trasporto pneumatico di polveri/granuli a breve distanza, estrazione della polvere, attrezzature per la raccolta delle polveri
Soffio d'aria per la stampa, laminazione, macchine per il soffiaggio e il rivestimento di pellicole
Raffreddamento delle apparecchiature, fornitura d'aria, trasporto aereo, ventilazione ambientale, raccolta polveri di lavorazione del legno
✅Selezione & Punti di supporto
Parole chiave di ricerca: CX-75A, Ventilatore Turbo a media pressione, 0.75kW Ventilatore a media pressione
Accessori opzionali: Filtro dell'aria, silenziatore, serranda di regolazione, connettore del tubo, piedini ammortizzanti
Installazione: Connettori flessibili consigliati in ingresso e in uscita per ridurre la trasmissione delle vibrazioni. È necessario installare un filtro dell'aria in ingresso per evitare che la polvere danneggi la girante in alluminio.
✅ Risoluzione dei problemi comuni
- Flusso d'aria ridotto: Filtro di ingresso intasato, perdita d'aria nelle tubazioni, accumulo di polvere sulla girante
- Intervento per surriscaldamento: Pressione sovraccarica, tensione instabile, passaggio di dissipazione del calore ostruito
- Rumore anomalo: Cuscinetto usurato, involucro della girante che sfrega, corpi estranei entrano nella camera
- Vibrazioni eccessive: Nessun assorbimento degli urti alla base, girante sbilanciata, collegamento di tubi rigidi
✅ Confronto all'interno della stessa serie (Per la selezione alternativa)
CX-75SA (0.4kW) < CX-75A (0.75kW) < CX-100A (1.5kW) < CX-125A (2.2kW)
CX-75A (0.75Ventilatore a media pressione kW Turbo) Casi di applicazione
Vantaggi fondamentali: Media pressione e grande volume d'aria, design ad accoppiamento diretto esente da manutenzione. Adatto per applicazioni di soffiaggio/aspirazione con resistenza nelle tubazioni, different from high-pressure ring blowers. Ideale per piccoli & attrezzatura media e funzionamento continuo 24 ore su 24.
🔥 Caso 1: Fornitura d'aria per bruciatori / Piccoli Forni Industriali (Applicazione classica)
Condizioni di lavoro: Bruciatori a biomassa, bruciatori diesel, piccoli inceneritori, forni ad aria calda per il reintegro dell'aria comburente.
Soluzione: CX-75A fornisce aria stabile a media pressione per superare la resistenza degli ugelli e dei filtri del bruciatore, garantendo un rapporto stabile di ossigeno. Modello trifase 380V per funzionamento continuo.
Accessori: Filtro dell'aria in ingresso, serranda aria manuale per la regolazione del flusso; utilizzare il modello CX-75AH termoisolato per condizioni di lavoro ad alta temperatura per isolare il calore radiante dal forno.
Punto chiave: La pressione dell'aria stabile impedisce lo spegnimento della fiamma; molti piccoli bruciatori domestici adottano questo modello come standard OEM.
🧹 Caso 2: Raccolta polveri per la lavorazione del legno / Lavorazione della pietra
Condizioni di lavoro: Aspirazione polveri a stazione singola per piccole fresatrici per legno CNC, levigatrici, smerigliatrici a pietra con box raccolta polveri.
Soluzione: Il ventilatore crea una pressione negativa per estrarre trucioli di legno e polvere di quarzo; il flusso d'aria di 13 m³/min supporta la tubazione delle polveri a stazione singola.
Nota: Installare la cartuccia / filtro primario in aspirazione per evitare l'abrasione della girante in alluminio da parte della polvere. Ridurre al minimo i gomiti a 90° nelle tubazioni per ridurre la resistenza.
🧾 Caso 3: Asciugatura con lama d'aria per la stampa, Laminazione & Attrezzatura per il soffiaggio della pellicola
Condizioni di lavoro: Stampanti per etichette autoadesive, macchine per rivestimento, soffiatori di pellicola, stampa di etichette, blow off moisture on paper/film surface and assist static elimination.
Soluzione: CX-75A supplies continuous medium-pressure airflow to air knives to blow off ink moisture, accelerate drying and avoid adhesion.
Caratteristica: Moderate air pressure, will not deform thin paper or film; stable air flow for continuous roll production.
🧪 Case 4: Blow-off for PCB / Glass Washing Lines (Industria elettronica)
Condizioni di lavoro: Blow residual water after ultrasonic cleaning of PCB etching lines and flat glass.
Soluzione: Air is fed to air knives to remove water droplets from workpiece surface, lower cost compared with high-pressure air compressors.
Suggerimento per la selezione: Per ambienti umidi, adopt moisture-proof motor treatment and install mist filter at air inlet.
🥣 Case 5: Food Machinery · Short-distance Pneumatic Conveying of Powder & Granules
Condizioni di lavoro: Grain sorting, sugar powder, starch, plastic pellets short-distance conveying (5~10m pipeline), piccola macchina di alimentazione centralizzata.
Soluzione: La pressione positiva spinge il materiale granulare a superare la resistenza dei gomiti dei tubi; girante in acciaio inossidabile disponibile per requisiti di grado alimentare.
Limitazione: Solo per trasporti a breve distanza e a bassa concentrazione; aggiornamento a CX-100A per carichi di polvere elevati e a lunga distanza.
💧 Caso 6: Aeration for Wastewater Treatment / Acquacoltura
Condizioni di lavoro: Aerazione per piccoli serbatoi biochimici, aquaculture nursery ponds, liquid agitation in electroplating tanks.
Soluzione: Il soffiatore fornisce aria ai dischi di aerazione microporosi per l'ossigenazione dell'acqua; la pressione media supera la profondità dell'acqua e la resistenza della tubazione.
Mancia: Dare priorità al modello trifase IP55 in ambienti umidi; il filtro di ingresso dell'aria impedisce agli amenti e ai detriti di bloccare i dischi di aerazione.
🌡️ Caso 7: Hot Air Circulation for Ovens & Constant Temperature Chambers
Condizioni di lavoro: Hot air circulation in small industrial ovens, armadi di asciugatura, matched with hot air generators.
Soluzione: CX-75A funge da ventilatore di circolazione per far circolare l'aria calda all'interno della camera e garantire una distribuzione uniforme della temperatura.
High-temperature Condition: È necessario utilizzare CX-75A termoisolato con piastra di isolamento termico per evitare la bruciatura del motore causata dalla conduzione del calore.
🛠️ Caso 8: Raffreddamento delle apparecchiature & Workpiece Chip Removal for Machine Tools
Condizioni di lavoro: Saldatura ad onda, raffreddamento della saldatura a riflusso, CNC machine tool chip blowing, auxiliary cooling for laser equipment.
Soluzione: Flusso d'aria direzionale continuo per raffreddare i pezzi e soffiare via la polvere di taglio dei metalli.
Selection Trade-off Guidelines (Pratica industriale)
- Gomiti multipli ed elevata resistenza del filtro → Soffiante a media pressione CX-75A; bassa resistenza che richiede solo una grande portata → ventilatore centrifugo a più ali; è necessaria un'elevata pressione negativa → soffiante ad anello ad alta pressione.
- Monofase 220V per piccole apparecchiature autonome; trifase 380 V consigliato per un funzionamento continuo prolungato in fabbrica.
- Per polveroso, condizioni umide o ad alta temperatura, upgrade accessories or select heat-insulated / versioni resistenti alla corrosione.
Alternative Models for Similar Applications
Flusso inferiore: CX-75SA (0.4kW)
Flusso più elevato: CX-100A (1.5kW)
Complete Industrial Fan Selection Methodology (Applicable for CX Turbo Blowers, Soffiatori ad anello, Ventilatori centrifughi, Versione ingegneristica)
Logica fondamentale: Definire i limiti delle condizioni di lavoro → Calcolare il flusso d'aria e la pressione → Selezionare il tipo di ventilatore → Verificare il mezzo & ambiente → Seleziona motore & materiale → Controllare il margine di sicurezza → Abbinare gli accessori
Fare un passo 1: Raccogliere i parametri di base delle condizioni di lavoro (Prerequisito per la selezione)
- Applicazione: Soffiaggio a pressione positiva / Aspirazione a pressione negativa / Circolazione dell'aria calda / Trasporto pneumatico / Aerazione / Dust collection
- Medio: Ambient air / Hot air / Dust-laden air / Moisture/oil mist / Corrosive gas
Clean ambient air: Standard aluminum turbo blower (CX-75A for example)
Alta temperatura: Heat-insulated turbo blower, high-temperature resistant centrifugal fan (heat insulation plate required to prevent heat transfer to motor)
Polvere pesante: Thickened impeller, prefiltro; heavy dust service: wear-resistant coating or stainless steel impeller
Corrosive gas: FRP / stainless steel housing with anti-corrosion coating
- Temperatura media: Ambiente (≤40℃), Temperatura media (40~180℃), Alta temperatura (>180℃)
- Ambiente: Al coperto / All'aperto, umido, explosion-proof requirement (Ex-proof motor mandatory for flammable gas/dust)
- Modalità operativa: Avvio-arresto intermittente / 24h continuous operation (motore trifase, Class F insulation preferred for continuous duty)
Fare un passo 2: Calculate Required Air Flow Q (m3/min)
Air Flow = Process Base Flow × Safety Factor
- Source of base process flow:
Dust collection: Air velocity at suction port × cross-sectional area of suction port; recommended suction velocity for dust:18~25m/s
Air knife drying: Cross-sectional area of air knife × designed outlet velocity
Trasporto pneumatico: Air volume for material carrying + pipeline leakage
Combustion air supply: Theoretical air volume calculated by fuel combustion
- Fattore di sicurezza: Normally 1.1~1.3; adottare 1.3 for long pipelines, many elbows and easy filter clogging.
Esempio: Process requirement 10m³/min, factor 1.3, selected air flow ≥13m³/min → CX-75A is suitable.
Passaggio 3: Calculate Total Pressure P (Pa/kPa)【Most Common Pitfall】
Fan total pressure is used to overcome total system resistance: pipeline resistance + filter resistance + elbows/reducers/valves + internal equipment resistance
- Resistance components:
Friction loss of straight pipe
Local resistance (90° elbow, tee, reducer, flexible joint, air damper, filtro)
Equipment internal resistance (bruciatore, cartuccia filtrante, air knife, aeration disc)
- Regola di selezione: Fan rated pressure ≥ Total system resistance × 1.1~1.2 margin
Quick comparison of fan categories by pressure range:
| Fan Type | Intervallo di pressione | Applicazione | Esempio di modello |
| Multi-wing Centrifugal Fan | <1kPa | Grande flusso, bassa resistenza, oven circulation, general exhaust | Multi-wing centrifugal fan |
| Ventilatore Turbo a media pressione | 1~10kPa | Medium resistance, dust collection, air knife, combustion air, short-distance conveying | CX Series (CX-75A) |
| Ring Blower | 10~100kPa | High vacuum suction, vacuum feeding, narrow air knife | RB, HG Series |
Promemoria importante: Do NOT select fan only by power rating! For same 0.75kW, ring blower delivers high pressure but low flow; CX-75A features medium pressure and large flow.
Passaggio 4: Selection of Fan Structure & Tipo di unità
- Direct-coupled (CX Series): Motor and impeller coaxial, dimensioni compatte, esente da manutenzione, fixed speed; adatto per piccoli & medium power and 24h continuous running, CX-75A belongs to this type. Svantaggio: Speed cannot be adjusted without VFD.
- Belt Drive: Speed adjustable via pulley, for larger power; disadvantage: belt periodic replacement, maintenance required.
- Coupling Drive: High-power industrial centrifugal fans for large dust collection and ventilation.
Passaggio 5: Motore, Alimentazione elettrica & Selezione della classe di protezione
- Alimentazione elettrica:
Monofase 220V: Piccolo potere, funzionamento intermittente della macchina autonoma
Trifase 380V: Preferito per il funzionamento continuo in fabbrica, maggiore efficienza e migliore capacità di sovraccarico
- Classe di isolamento: Classe F consigliata per il funzionamento continuo; Classe H per alte temperature
- Classe di protezione:
IP54: Officina normale e asciutta
IP55: Umido & laboratorio polveroso (comune per la serie CX)
IP65: Ambiente con molta polvere e spruzzi d'acqua
- A prova di esplosione: Motore antideflagrante richiesto per polveri/gas infiammabili.
Passaggio 6: Verifica delle condizioni di lavoro (Eliminare i modelli non idonei)
- Trasporto pneumatico: A breve distanza, bassa concentrazione → turboventilatore CX; alta concentrazione a lunga distanza → Soffiatore per radici
- Aspirazione delle polveri a pressione negativa: Dare priorità al controllo della pressione negativa quando la resistenza della tubazione è elevata; La pressione negativa massima del CX-75A è 1,7 kPa, in caso di superamento passare al soffiatore ad anello.
- Aria calda: Il ventilatore CX standard non può essere utilizzato direttamente per l'aria calda; la conduzione del calore brucerà il motore, use CX-H heat-insulated model with heat shield.
- Noise Requirement: Install inlet/outlet silencer, shock pad and flexible joint for noise above 65dB.
Step7: Selection of Auxiliary Accessories (Indispensable for System, Often Neglected)
Inlet side: Filtro dell'aria (mandatory for dusty application), silenziatore, vacuum/pressure gauge
Outlet side: Silenziatore, valvola di ritegno (prevent backflow after shutdown), manual/electric damper, flexible canvas joint
Base: Shock-absorbing foot pads to reduce vibration transmission; flexible joint is mandatory for rigid pipe connection to avoid casing crack.
Step8: Simplified Decision Flow Chart for CX-75A Selection
- Process air flow 8~13m³/min, total system resistance 1~2.4kPa
✅ Prefer CX-75A (0.75Ventilatore a media pressione kW Turbo)
- Air flow less than 8m³/min, resistance 1~2kPa → CX-75SA (0.4kW)
- Air flow>13m³/min, resistance 2~3kPa → CX-100A (1.5kW)
- System resistance>3kPa → Abandon CX turbo blower, selezionare il soffiatore ad anello
- Resistenza <1kPa, è necessaria solo una grande portata di circolazione → Ventilatore centrifugo a più ali
Passaggio 9: Errori comuni di selezione
- ❌ Selezionare la ventola solo in base alla potenza del motore: I ventilatori con la stessa potenza nominale presentano un'enorme differenza nel flusso d'aria e nella pressione per i diversi tipi.
- ❌ Nessun margine di resistenza riservato: L'intasamento del filtro aumenta la resistenza del sistema in servizio e porta a un flusso insufficiente.
- ❌ Nessun filtro per condizioni di lavoro polverose, con conseguente rapida usura della girante e durata di servizio ridotta.
- ❌ Utilizzare il ventilatore CX standard direttamente per l'aria ad alta temperatura, causando la combustione del motore per conduzione di calore.
- ❌ Collegamento tubo rigido in ingresso/uscita, le vibrazioni provocano crepe nell'involucro e rotture delle saldature.
Passaggio 10: Elenco dei risultati finali per il documento di selezione dei tifosi
- Flusso d'aria di processo e resistenza totale del sistema
- Parametri medi, temperatura, dust condition
- Fan model, operating point on P-Q performance curve (must stay within high-efficiency zone)
- Motor parameters: Voltaggio, energia, isolamento, protection class, explosion-proof requirement
- Materiale, ingresso & outlet dimension
- Accessory list and vibration isolation scheme
CX Turbo Medium-pressure Blower Full Model List (50Hz, Standard Ambient Model, Same Series as CX-75A)
Descrizione del suffisso:
UN: Standard direct-coupled type; H: High-temperature heat-insulated model (CX-XXAH), fitted with heat shield for hot air service
Alimentazione elettrica: 1~ Single-phase 220V / 3~ Three-phase 380V; small models support both single & three phase, large models only three-phase
Misurare: IN=Inlet, OUT=Outlet; flow and pressure refer to maximum parameters under 50Hz
| Modello | Energia(kW) | Max Air Flow(m鲁/min) | Max Positive Pressure(kPa) | Max Negative Pressure(kPa) | Ingresso & Presa(mm) | Peso netto(kg) |
| CX-65A | 0.2 | 4.5 | 1.1 | 0.7 | IN100 / OUT65 | 7 |
| CX-75SA | 0.4 | 7 | 1.6 | 1.1 | IN100 / OUT75 | 10 |
| CX-75A | 0.75 | 13 | 2.4 | 1.7 | IN125 / OUT100 | 14~16 |
| CX-100A | 1.5 | 20 | 3 | 2 | IN125 / OUT100 | 26~28 |
| CX-125A | 2.2 | 32 | 3.7 | 2.4 | IN252 / OUT125 | 36~38 |
| CX-150A | 3.7 | 46 | 4.4 | 3.2 | IN252 / OUT150 | 52~54 |
Derived High-temperature Models (CX-XXAH, with Heat Shield for Hot Air / Furnace Combustion)
CX-75SAH (0.4kW, high temp version of CX-75SA)
CX-75AH (0.75kW, high temp version of CX-75A, per l'alimentazione dell'aria calda del forno e del bruciatore)
CX-100AH (1.5kW)
CX-125AH (2.2kW)
CX-150AH (3.7kW)
Riferimento per la selezione rapida
- CX-65A (0.2kW): Basso flusso e bassa resistenza, raffreddamento di piccole apparecchiature e semplice soffiaggio dell'aria
- CX-75SA (0.4kW): Soffio/aspirazione a bassa potenza, piccole macchine per etichette, aerazione della piccola acquacoltura
- CX-75A (0.75kW): Il più versatile, alimentazione dell'aria comburente, asciugatura con lama d'aria, raccolta polveri a stazione singola (modello di destinazione)
- CX-100A (1.5kW): Raccolta polveri a doppia stazione, lama d'aria a grande flusso, trasporto pneumatico
- CX-125A (2.2kW): Aspiratore multistazione, circolazione dell'aria calda del forno, trasporto delle polveri
- CX-150A (3.7kW): Ampia raccolta di polvere, aria di combustione di forni industriali, aerazione a grande flusso
Note importanti
- Modelli di diversi produttori (Vento pieno, MANVAC, Ouguan ecc.) avere parametri di prestazione coerenti, solo una leggera differenza di peso.
- Aumento del flusso d'aria e della pressione di circa il 15% sotto 60 Hz; controlla la curva delle prestazioni a 60 Hz per i progetti di esportazione.
- Questa serie è un ventilatore turbo a media pressione, non è la stessa serie del turboventilatore multistadio HTB e del soffiatore ad anello ad alta pressione RB, non mescolarli.
Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore




















NH42-63-318x560.png)