Schneider BMXDDI3202KH Digital Input Module - Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Schneider BMXDDI3202KH Digital Input Module - Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

PLC/

Schneider BMXDDI3202KH Digital Input Module

Serie: Modicon X80 (PLC M340) Model explanation: BMXDDI3202KH = BMXDDI3202K + H; H = Conformal Coating version for harsh environments. Electrical specifications are identical to BMXDDI3202K. Only the PCB is coated with conformal coating for moisture-proof, mould-proof and salt-spray resistance, suitable for ports, impianti chimici, underground sites, high-humidity and dusty conditions. ✅ Basic Specifications Type: ...

  • Dettagli del prodotto

Serie: Modicon X80 (PLC M340)

Model explanation: BMXDDI3202KH = BMXDDI3202K + H; H = Conformal Coating version for harsh environments. Electrical specifications are identical to BMXDDI3202K. Only the PCB is coated with conformal coating for moisture-proof, mould-proof and salt-spray resistance, suitable for ports, impianti chimici, underground sites, high-humidity and dusty conditions.

✅ Specifiche di base

Tipo: 32-channel isolated digital input module, Lavello (positive logic)

Tensione in ingresso: 24VCC, sensor supply range 19~30VDC

Input current per channel: 2.5mA @24V

Logica 1: ≥11V / ≥2mA; Logica 0: ≤5 V / ≤0.5mA

Impedenza di ingresso: 9600OH

Tempo di risposta: Typical 4ms, maximum 7ms

Isolamento: Channel-to-channel isolation, resistenza di isolamento >10MΩ at 500VDC

Cablaggio: Compatible with 2-wire / 3-wire proximity switches (IEC61131-2 Type3, IEC60947-5-2). Input parallel connection is not allowed

Connettore: Single 40-pin FCN interface, single slot, supporto hot-swap

Consumo energetico: ≤3.9W; Typical backplane 3.3V consumption 121mA

Protezione della custodia: IP20

📌 Matching Cables (40-pin FCN)

  1. BMXFCWxxx3: Pre-wired loose cables (3m/5 m/10 m: BMXFCW303 / BMXFCW503 / BMXFCW1003)
  2. BMXFCCxxx3: Pre-assembled HE10 terminal cables (0.5/1/2/3/5/10M)

🧩 Compatible CPUs

Full Modicon M340 series: BMXP34xx00, BMXP34xx20 (including H versions). General X80 rack, configured via Unity Pro software.

⚖️ Model Comparison

BMXDDI3202K: Versione standard, no conformal coating, for conventional control cabinets

BMXDDI3202KH: Conformal coated version for harsh environments. Fully interchangeable in program, pinout and cabling.

📎 Alternative Selection Reference

Same-platform replacement: No drop-in equivalent. For fewer points, refer to BMXDDI1602K(H) (16-point Sink DI).

Sostituzione domestica: Verify sink logic, isolation and filter time, suitable for domestic PLC remote IO modules.

⚠️ Troubleshooting Tips

  1. No input signal: Check 24V supply, sensor polarity (Lavello, signal connects to 0V), broken pins in prefabricated cables.
  2. Lampeggiante / falso innesco: Check voltage drop and shielding. This module uses fixed hardware filter; filter parameters cannot be modified by software.
  3. Prefer KH version for humid and corrosive environments; standard K version is prone to PCB corrosion under long-term high humidity.

Schneider Ingresso digitale (DI) Module List by Platform

Nota: Suffix H = Conformal coating for harsh environments. X80 platform compatible with M340 / M580; Sink = sinking input, Source = sourcing input; AC = AC input.

  1. Modicon X80 (BMX series, M340 / M580)

Ingresso digitale CC (BMXDDI)

ModelloPuntiDescrizione
BMXDDI1602K / BMXDDI1602KH1624VCC, Lavello
BMXDDI1603K / BMXDDI1603KH1648VCC, Lavello
BMXDDI1604T16125VCC, Lavello, ampia temperatura
BMXDDI3202K / BMXDDI3202KH3224VCC, Lavello (the model you enquired)
BMXDDI3203K / BMXDDI3203KH3248VCC, Lavello
BMXDDI3232K / BMXDDI3232KH3212/24VCC, Sink/Source configurable
BMXDDI6402K / BMXDDI6402KH6424VCC, Lavello

AC Digital Input (BMXDAI)

ModelloPuntiDescrizione
BMXDAI08058220VCA
BMXDAI08148100~120VAC
BMXDAI16021624VAC/24VDC, Fonte
BMXDAI16031648VCA
BMXDAI160416100~120VAC
BMXDAI161416220VCA

X80 Safety DI (Safety PLC dedicated)

ModelloPuntiDescrizione
BMXSDI160216Safety digital input, 24VCC
  1. TM3 Series (Expansion for M221/M241/M251/M262 Compact PLC)
ModelloPuntiDescrizione
TM3DI8824VCC, terminali a vite
TM3DI8G824VCC, spring clamp terminals
TM3DI8A8120VCA
TM3DI161624VCC, terminali a vite
TM3DI16G1624VCC, spring clamp terminals
TM3DI16K1624VCC, HE10 connector
TM3DI32K3224VCC, HE10 connector
  1. Advantys STB Distributed Remote IO
ModelloPuntiDescrizione
STBDDI37251624VDC Sink
STBDDI3420824VDC Sink
STBDDI3610424VDC Sink
STBDAI02002100~240 VCA
STBDAI04004100~240 VCA
  1. Note supplementari
  2. X80 naming rule: `BMXDDI` = DC DI; `BMXDAI` = AC DI; `K` standard, `KH` conformal coated.
  3. K and KH variants of the same model are fully interchangeable in pinout, programming and backplane interface, only differing in PCB protection.
  4. Mixed I/O modules (DI+DO) such as BMXDDM16022 are excluded from this table.

Application Scenarios of Schneider Digital Input (DI) Moduli (X80/STB/TM3, ecc.)

Core function of DI modules: Collect binary switch signals, transfer ON/OFF status from external dry contacts, sensori, pulsanti, limit switches and auxiliary contacts of contactors to PLC. It only detects on/off status and does not process analog signals. The following is sorted by industry and signal type, applicable to BMXDDI3202KH and other X80 modules.

  1. General Signal Acquisition (Used across all industries)
  2. Pulsanti, selettori, pulsanti di arresto di emergenza

Local cabinet operation, remote control boxes, E-stop signals (general E-stop; safety E-stop should use dedicated safety DI module BMXSDI1602).

  1. Interruttori di limite, interruttori di viaggio, interruttori di prossimità, sensori fotoelettrici

Equipment position detection: cylinder confirmation, interruttori delle porte, baffle limit for material level, object presence detection.

BMXDDI3202KH is 24VDC Sink, compatible with mainstream NPN proximity switches.

  1. Auxiliary contacts of contactors / relè, circuit breaker status feedback

Motor running feedback, VFD ready feedback, circuit breaker open/close status, thermal relay fault signals.

  1. Dry contact signals

Fire alarm systems, controllo degli accessi, damper/valve position feedback in HVAC, float level switches.

  1. HVAC

Corsa / fault feedback of fans and water pumps

Differential pressure switches, frost protection switches, air damper / water valve end-position feedback

Filter differential pressure alarm, high/low float level switches

Feedback of smoke exhaust dampers and fire dampers

Conformal coated KH versions (BMXDDIxxxxKH) are preferred for humid and dusty machine rooms.

  1. Trattamento delle acque, Fornitura d'acqua & Drenaggio, Impianti di acque reflue

Level switches (alto livello, basso livello, overflow)

Pump run, colpa, hand-auto status

Limit signals for bar screens and sludge scrapers

Pulse signals from flow meters (high-speed pulses require dedicated high-speed counter modules; standard DI is not suitable for high-frequency pulses)

Valve open / closed position feedback

KH coated modules are widely used in corrosive, high-humidity wastewater sites.

  1. Confezione, Linee di assemblaggio & Linee di produzione automatizzate

Photoelectric detection for material presence / missing material

Cylinder and clamp confirmation signals

Conveyor belt jam and deviation switches

Barcode detection, silo level switches

Safety gate and guard door status signals

BMXDDI6402K (64-point DI) is commonly used for high-point-count lines to save slots.

  1. Crane Systems, Trasmettere & Warehouse Logistics

Crane travel limits, upper/lower hard limits, buffer switches

Pallet in-position, bay detection

Roller conveyor deviation and E-stop loop feedback

Roller shutter and guard door status

  1. Power Distribution Rooms & Energy Monitoring

Circuit breaker and disconnector open/close position feedback for high-voltage cabinets

Cabinet door interlock, earthing switch status

Transformer thermostat switches, cooling fan feedback

DC panel fault alarm dry contacts

BMXDAI AC DI modules are often used for 220VAC cabinet signals.

  1. Olio & Gas, Industria chimica, Porti (Ambienti difficili)

Valve position feedback, pump status, dry contact output of combustible gas detectors

Limit switches and door interlocks for trestle and quay equipment

Salt spray, high humidity and condensation → select KH conformal coated versions (BMXDDI3202KH etc.). Standard K versions are vulnerable to corrosion.

  1. Automazione degli edifici, Fire Protection & Stazioni di pompaggio

Dry contact alarms from fire host, sprinkler pressure switches

Elevator interlock signals, smoke exhaust fan status

Rainwater pumps, sump tank level monitoring

✅ Quick Selection Guide by Scenario

Normal indoor control cabinet, ambiente secco: BMXDDIxxxK

Chimico / porta / elevata umidità & nebbia salina: BMXDDIxxxKH (rivestimento conforme)

220VAC contact signals: BMXDAI AC DI

Circuiti di sicurezza, cancelli di sicurezza, safety E-stop: BMXSDI safety DI

Piccole macchine, low I/O count: TM3DI series

Distributed remote IO with scattered field points: STB Advantys remote DI

⚠️ Scope Limitations (What DI modules cannot do)

  1. Cannot directly measure 4-20mA or temperature (AI analog modules required)
  2. Standard DI is not suitable for high-frequency pulse counting (high-speed counter module required)
  3. Safety functions shall not be implemented via ordinary DI; dedicated safety DI modules are mandatory.

Prec:

Prossimo:

Lascia una risposta

Lasciate un messaggio