Schneider GV2P32 Motor Circuit Breaker

The GV2P32 is a 3-pole thermal-magnetic motor circuit breaker (MPCB) from Schneider TeSys GV2 series. It features an adjustable current setting of 24-32A, compatible with 15kW @ 400V three-phase motors. Providing dual protection against overload and short circuit, with IP20 protection degree, it is widely applied in industrial motor control circuits. Model Code Explanation Code ...

  • Dettagli del prodotto

The GV2P32 is a 3-pole thermal-magnetic motor circuit breaker (MPCB) from Schneider TeSys GV2 series. It features an adjustable current setting of 24-32A, compatible with 15kW @ 400V three-phase motors. Providing dual protection against overload and short circuit, with IP20 protection degree, it is widely applied in industrial motor control circuits.

  1. Spiegazione del codice modello
Segmento di codiceSensoDescrizione
GV2Serie di prodottiTeSys GV2 series motor circuit breakers for motor overload and short-circuit protection
POperation TypeRotary knob manual control, imported version (equivalente domestico: GV2PM series)
32Valutazione attualeAdjustable setting range: 24-32UN, for motor circuits with rated current up to 32A

Definizione completa del modello: GV2P32 = Schneider GV2 series, rotary knob type, 32A rated motor circuit breaker

  1. Specifiche tecniche principali
CategoriaSpecificheOsservazioni
General Characteristics
Tipo di prodotto3-pole thermal-magnetic motor circuit breaker (MPCB)Conforme alla norma CEI 60947-4-1
Adjustable Current Range24-32UN (regolabile)Thermal trip with ambient temperature compensation
Poli3P (Trifase)Designed for three-phase motor protection
Modalità operativaRotary knob manual controlWith ON/OFF indicator and lockable function
Parametri Elettrici
Tensione operativa nominale230-690V e, 50/60HzSuitable for global industrial power grids
Potenza motore compatibile15kW @ 400/415V, 50/60HzMaximum applicable power under standard operating conditions
Magnetic Trip Threshold12×In = 384A (Instant short-circuit protection)Fast disconnection upon short-circuit faults
Potere di interruzione in cortocircuito10kA @ 400V, 50HzMeets industrial standard requirements
Tipo di terminaleMorsetti a viteApplicable copper wire cross-section: 1.5-25mm²
Fisico & Parametri Ambientali
Grado di protezioneIP20Prevents finger access to live parts
Tipo di montaggioGuida DIN standard da 35 mmModular installation, salvaspazio
Dimensioni (L×A×P)45×85×95mmCompact design for distribution cabinets
Temperatura operativa-25℃ ~ +60 ℃Wide temperature range for industrial environments
CertificazioniCCC, UL, CSA, EAC, Marine Classification (DNV, GL, BV), ATEXMultiple certifications for global application
Informazioni sull'ordinazione
Manufacturer Part No.GV2P32Official Schneider model
Codice d'ordine standardGV2P32Original imported version
  1. Full GV2P Series Model List
ModelloAdjustable Current RangePotenza motore compatibile (400V)Corrente di intervento magnetico
GV2P010.16-0.25UN0.06kW3.0UN
GV2P020.25-0.4UN0.12kW4.8UN
GV2P030.4-0.63UN0.25kW7.6UN
GV2P040.63-1UN0.37kW12UN
GV2P051-1.6UN0.75kW19UN
GV2P061.6-2.5UN1.1kW30UN
GV2P072.5-4UN1.5kW48UN
GV2P084-6.3UN3kW76UN
GV2P096.3-10UN4kW120UN
GV2P1010-16UN7.5kW190UN
GV2P1413-18UN11kW216UN
GV2P1616-24UN11kW288UN
GV2P2020-32UN15kW384UN
GV2P3224-32UN15kW384UN
GV2P4032-40UN18.5kW480UN
  1. Modelli sostitutivi & Confronto della concorrenza

4.1 Internal Schneider Replacements

Modello originaleModello sostitutivoDifferenzeScenari applicativi
GV2P32 (Importato)GV2PM32C (Domestico)Different origin, minor certification differences; profondità: 91mm (GV2P: 95mm)Domestic projects, cost-sensitive applications, CCC certification required
GV2P32GV2ME32 (Domestic push-button type)Funzionamento tramite pulsante, parametri elettrici identiciApplications requiring push-button control, limited budget
GV2P32GV3P32 (Upgraded series)Higher breaking capacity and enhanced functionsEnvironments with high short-circuit risk, advanced protection required

4.2 Cross-brand Competitor Comparison

MarcaModelloIntervallo correntePoliMagnetic Trip RatioPrincipali differenze
SchneiderGV2P3224-32UN3P12×InMultiple certifications including marine approval, IP20
ABBMS325-3224-32UN3P12×InPotere di interruzione: 15IL, larger dimensions
Siemens3RV2031-4KA1024-32UN3P13×InOptional electronic trip, prezzo più alto
EatonPKZM0-3224-32UN3P12×InSpring terminals for easy installation
CintoNM1-63S/330025-32UN3P10×InCost advantage, alternativa domestica
  1. Ambienti applicativi & Casi tipici

5.1 Applicazioni consigliate

Controllo motori industriali: Main circuit protection for three-phase motors such as pumps, tifosi, compressori e trasportatori

Attrezzatura OEM: Supporting machine tools, macchine per l'imballaggio, printing machines and textile machinery

Realizzazione di impianti elettrici: Protection for critical motors including air conditioning units, fire water pumps and drainage pumps

Marino & Offshore Engineering: Compliant with marine classification standards for ship power systems

Aree pericolose: ATEX certified for motor protection in non-explosion-proof zones

5.2 Not Recommended Applications

Single-phase Motors: 3-pole design not suitable for single-phase circuit protection

Frequent Start-Stop Operations: Più di 10 cycles per hour will shorten service life

High Altitude (>2000M): È necessario un declassamento (10% reduction per 1000m rise)

Severe Vibration Environments: Extra reinforcement needed to avoid false tripping

Corrosive Environments: IP20 protection is insufficient; additional enclosure is required

5.3 Casi applicativi tipici

Caso 1: Water Treatment Plant Pump Protection

Attrezzatura: 3 sets of 15kW submersible three-phase pumps (400V)

Configurazione: GV2P32 + LC1D32 Contactor + LRD3322 Thermal Overload Relay (redundant protection)

Risultato: Prevented 3 motor overload faults and 1 short-circuit fault, extending equipment service life by 2 anni

Caso 2: Conveyor System in Automobile Manufacturing Plant

Attrezzatura: 12 conveyor lines each equipped with 15kW motor

Configurazione: GV2P32 linked with Schneider PLC

Caratteristiche: Rotary knob enables quick on-site reset and reduces downtime

  1. Risoluzione dei problemi & Maintenance Manual

6.1 Difetti comuni & Soluzioni

Fenomeno di guastoPossibili causeSoluzioni
Frequent thermal tripping1. Sovraccarico del motore1. Check motor load and eliminate mechanical jamming
2. Improper low current setting2. Set current to 1.1 times motor Full Load Current (FLA)
3. Temperatura ambiente eccessivamente elevata3. Migliorare la ventilazione e abbassare la temperatura ambiente
4. Loose terminals causing overheating4. Inspect and tighten terminals
Instant magnetic tripping1. Circuit short circuit1. Power off and test circuit insulation
2. Damaged motor winding insulation2. Measure winding resistance and replace faulty motor
3. Arc short circuit inside contactor3. Inspect contactor contacts and replace if necessary
Mancata chiusura1. Tripping mechanism not reset1. Turn knob to OFF position then re-close
2. Damaged rotary knob2. Check knob linkage and replace damaged parts
3. Internal mechanical failure3. Arrange professional maintenance or replace the breaker
Nessuna uscita dopo la chiusura1. Burned internal contacts1. Spegnimento, inspect main contacts and replace defective unit
2. Cablaggio errato2. Verify wiring to ensure correct three-phase connection
3. Faulty tripping mechanism3. Check tripping mechanism and replace if needed

6.2 Maintenance Procedures

  1. Ispezione giornaliera (Settimanale)

Check knob position and status indication

Look for abnormal heat, odor or noise

Confirm all terminals are tightly connected

  1. Manutenzione ordinaria (Ogni 6 Mesi)

Power off and remove dust with dry compressed air

Inspect main contacts for burning and oxidation

Test tripping function by simulating overload and short circuit conditions

  1. Manutenzione annuale

Check lubrication of internal mechanical components

Verify accuracy of current setting

Retighten all electrical connections

6.3 Quick Diagnosis Tips

Thermal trip? Check load and current setting.

Magnetic trip? Locate short circuit and test insulation.

Fail to close? Reset first; replace for mechanical faults.

Nessuna uscita? Inspect contacts and wiring.

  1. Selezione & Linee guida per l'installazione

7.1 Regole di selezione

Corrispondenza attuale: Motor FLA must fall within 24-32A; recommended setting: FLA × 1.1

Abbinamento di potenza: Standard solution for 15kW @ 400V three-phase motors

Coordinamento della protezione: Use with contactors and fuses to ensure selective protection

Ambient Derating: Declassare 1% per ℃ above 40℃

7.2 Note di installazione

Direzione di montaggio: Installazione verticale (allowable deviation: ±15°) for normal tripping operation

Liquidazione: Reserve 10mm space on left & right sides, 20mm on top & bottom for heat dissipation

Wiring Standard: Copper wire with cross-section 1.5-25mm²; coppia di serraggio: 6-8Nm

Locking Function: Padlock can be fitted to prevent accidental operation, complying with safety regulations

  1. Production Status & Soluzioni di aggiornamento

Current Status of GV2P32: In produzione, no discontinuation plan (as of June 2026)

Aggiornamento & Opzioni di sostituzione:

  1. Aggiornamento funzionale: GV3P32 (higher breaking capacity and extra protection functions)
  2. Alternativa domestica: GV2PM32C (lower cost with equivalent performance)
  3. Aggiornamento intelligente: TeSys T series (with communication for remote monitoring)