This is a ABB F200 Series 4-pole Type B Residual Current Circuit Breaker (RCD) with a rated current of 63A and a rated residual operating current of 30mA. This model is obsolete. The original manufacturer replacement part number is 2CSF204568R1630 (F204B-63/0.03-4TE). It is designed for industrial applications equipped with frequency converters, UPS and other devices, ...

  • Dettagli del prodotto

Questo è un ABB F200 Series 4-pole Type B Interruttore automatico della corrente residua (RCD) with a rated current of 63A and a rated residual operating current of 30mA. This model is obsolete. The original manufacturer replacement part number is 2CSF204568R1630 (F204B-63/0.03-4TE). It is designed for industrial applications equipped with frequency converters, UPS and other devices, and provides protection against smooth DC leakage current.

  1. Spiegazione del codice modello
Segmento modelloDefinizioneDescrizione dettagliata
F204Modello baseF200 Series, 4-pole residual current circuit breaker
BTipo di corrente residuaTipo B, capable of detecting AC, pulsating DC and smooth DC residual current (0-1000Hz)
63Corrente operativa nominale63UN, continuous current rating
0.03Corrente operativa residua nominale0.03A = 30mA, high-sensitivity protection against direct human contact
2CSF204592R1630Codice ordineUnique official ABB identification code for purchasing and traceability
4ILTipo di montaggioStandard DIN rail mounting with 4-pole terminals (marked on partial versions)
  1. Principali Specifiche Tecniche
CategoriaDati tecniciOsservazioni
Caratteristiche di base
Tipo di prodottoInterruttore automatico della corrente residua (RCD)No overload or short-circuit protection; must be used with MCB
SerieSystem pro M compact® F200ABB modular power distribution product line
Poli4P (L1, L2, L3, N)Protection for 3-phase 4-wire systems
Tensione nominale400V e (50/60Hz)Intervallo di tensione operativa: 380-415V
Corrente nominale (In)63UNCompliant with IEC/EN 61008-1
Corrente operativa residua nominale (IΔn)30mATipo istantaneo (no time delay)
Tipo di corrente residuaTipo BComprehensive protection against AC, pulsating DC and smooth DC leakage current
Parametri di prestazione
Capacità di interruzione (IΔm)3ILBreaking capacity under rated conditions
Tempo di funzionamento≤0.04s @ IΔn=30mAMeets requirements for rapid personal safety protection
Rated Residual Non-operating Current (Io... no)15mANo tripping below this value to avoid nuisance tripping
Test ButtonIntegratoFor regular functional testing
Caratteristiche fisiche
Dimensioni (L × A × P)70mm × 85mm × 60mmDesign modulare standard, occupa 4 module units
Montaggio35Guida DIN da mmConforme alla norma EN 50022
Tipo di terminaleBi-directional cylindrical terminalsFacilitates cable connection and enhances safety
Pesoca. 360GWeight per unit
Ambiente & Certificazioni
Temperatura operativa-25°C~+55°CPerformance may be affected beyond this range
Temperatura di conservazione-40°C~+85°C
Umidità5% ~ 95% (senza condensa)
Protezione dall'ingressoIP20A prova di dita, not suitable for outdoor use
CertificazioniCEI/EN 61008-1, CEI/EN 61008-2-1Certificato CE, complies with international safety standards
Stato del ciclo di vita
StatoObsoletoStock still available via some distributors
Data di interruzioneJun-24Official record
  1. Elenco completo dei modelli (F204 Type B)
ModelloCodice ordineCorrente nominaleRated Residual CurrentCaratteristiche
F204 B-25/0.032CSF204592R125025UN30mA4-pole Type B, basic model
F204 B-40/0.032CSF204592R140040UN30mA4-pole Type B, medium current
F204 B-63/0.032CSF204592R163063UN30mA4-pole Type B, standard industrial model
F204 B-63/0.12CSF204592R263063UN100mA4-pole Type B, higher sensitivity
F204 B-63/0.32CSF204592R363063UN300mA4-pole Type B, equipment protection
F204 B-63/0.52CSF204592R463063UN500mA4-pole Type B, system protection
F204 B-80/0.032CSF204592R180080UN30mA4-pole Type B, corrente elevata
F204 B-100/0.032CSF204592R1100100UN30mA4-pole Type B, extra high current
F204 B-125/0.032CSF204592R1125125UN30mA4-pole Type B, maximum current
F204 B-63/0.03-4TE2CSF204568R163063UN30mAModello sostitutivo, 4-pole Type B, standard terminals
  1. Soluzioni sostitutive & Equivalenti cross-brand

4.1 Original Manufacturer Replacements

Modello originaleModello sostitutivoMotivo della sostituzioneCompatibilità
F204 B-63/0.03 (2CSF204592R1630)F204 B-63/0.03-4TE (2CSF204568R1630)Product upgrade with optimized terminal designPienamente compatibile, sostituzione diretta
DDA204 B-63/0.03 AP-R (2CSB204592R1630)FI-Block series, integrated designIdentical mounting dimensions and functions

4.2 Cross-Brand Compatible Replacements

MarcaModelloTechnical Matching RateOsservazioni
SchneideriC60H RCCB 4P 63A 30mA Type B95%Dimensionally compatible, equivalent performance
Siemens5SU1356-6KK6390%Slight difference in tripping characteristics
Legrand4102 63 03 B90%Different wiring terminals
Cinto (Cina)NXBLE-400/4P 63A 30mA Type B85%Cost-effective with complete certifications
  1. Ambienti applicativi & Casi tipici

5.1 Applicazioni consigliate

Sistemi di Automazione Industriale: Frequency converters, servoazionamenti, PLC cabinets; protects against smooth DC leakage current.

Attrezzature mediche: Operating rooms, ICU devices; provides top-level leakage protection.

Centri dati: Sistemi UPS, server cabinets; prevents nuisance tripping caused by power fluctuation.

Energia rinnovabile: inverter fotovoltaici, sistemi di accumulo dell’energia; protects DC side leakage.

Edifici commerciali: Kitchen equipment, central air conditioning, elevator control systems; protection for 3-phase loads.

5.2 Non-Recommended Applications

Pure residential single-phase loads: Type B is overqualified; Type AC is sufficient.

Outdoor humid environments: IP20 rating is inadequate; additional enclosure protection required.

Aree pericolose esplosive: Explosion-proof products must be used.

Applications requiring overload/short-circuit protection: This unit only provides leakage protection and shall be used together with MCB.

5.3 Casi applicativi tipici

Caso 1: Automotive Manufacturing Workshop

Attrezzatura: Robotic welding systems, converter-driven production lines

Problema: Frequent nuisance tripping of conventional Type AC RCCBs affected production.

Soluzione: Install F204 B-63/0.03 to protect against smooth DC leakage generated by converters.

Risultato: Nuisance tripping rate reduced by 90%, production efficiency improved by 15%.

Caso 2: Hospital Operating Room

Attrezzatura: Anesthesia machines, patient monitors, surgical lights

Requirements: Highest safety level, zero nuisance tripping and fast response.

Soluzione: Adopt F204 B-63/0.03 combined with S204-B63 MCB.

Risultato: Complies with medical equipment safety standards and ensures operational safety.

  1. Risoluzione dei problemi & Maintenance Manual

6.1 Difetti comuni & Soluzioni

Fenomeno di guastoPossibili causePassaggi per la risoluzione dei problemi
Inciampi frequenti1. Actual circuit leakage1. Test circuit insulation with megohmmeter after power off
2. DC leakage from loads2. Verify if loads require Type B RCCB
3. Product aging3. Check production date; replace if service life exceeds 10 anni
4. Loose wiring terminals4. Retighten wiring terminals
Failure to trip1. Damaged test button1. Replace test button assembly
2. Internal trip mechanism fault2. Send for repair or replace the unit
3. Cablaggio errato (neutral wire disconnected)3. Check wiring and ensure neutral wire is properly connected
Cannot be reset1. Mechanical lock failure1. Manually reset after power off; replace if failed
2. Persistent leakage2. Eliminate leakage fault before resetting
3. Temperatura ambiente eccessivamente elevata3. Migliorare la ventilazione e abbassare la temperatura ambiente
Indicator light off1. Damaged indicator lamp1. Replace indicator lamp
2. Internal circuit fault2. Send for repair or replace the unit

6.2 Maintenance Procedures

  1. Ispezione di routine (Mensile)

Visually inspect for damage or discoloration.

Press test button to confirm normal tripping and reset.

Check terminals for looseness and overheating marks.

  1. Periodic Maintenance (Annualmente)

Clean unit surface with dry soft cloth after power cut.

Check firmness of DIN rail mounting.

Measure insulation resistance (≥1MΩ).

Record test results.

  1. Ciclo di sostituzione

Normal operating conditions: 10 anni

Ambienti difficili (alta temperatura / high humidity): 5~7 years

Frequent tripping conditions: 3~5 years

6.3 Quick Diagnosis Tips

Type B RCCB handles DC leakage well.

Check wiring first for frequent tripping; load type matters most.

Replace unit immediately if test button malfunctions.

Power off and clear faults before resetting.

Replace after 10 years for reliable safety.

  1. Linee guida per la selezione
  2. Residual Current Type Selection: Choose Type B for systems with converters, UPS or medical devices; Type AC for general lighting and sockets; Type A for pulsating DC loads.
  3. Selezione della corrente nominale: Corrente nominale ≥ 1.2 times total load current. 63A is suitable for most industrial control cabinets.
  4. Residual Current Rating Selection: 30mA per la protezione personale; 100~300mA for equipment protection; 500mA~1A for system protection.
  5. Selezione del palo: 2P for single-phase systems; 3P for 3-phase 3-wire systems; 4P (con filo neutro) for 3-phase 4-wire systems.
  6. Replacement Principle: Prioritize upgraded models from the same series for obsolete products to guarantee identical dimensions and performance.