3-contattore CA a polo, rated current 115A (AC-3), 220VAC coil, 1Contatti ausiliari NA+1NC, terminali a vite
Numero d'ordine: LC1D11500M7C (full model), LC1D115M7C (abbreviated model)
Domestic TeSys D series, phased out (launched in July 2025). Recommended replacements: LC1D115KUEC or LC1E120M5N
Complete certifications: UL, CSA, CEI, CCC, EAC, ecc. Compliant with RoHS/REACh standards
- Spiegazione del codice modello
| Segmento | Codice | Descrizione |
| Categoria di prodotto | LC1 | Contactor series |
| Construction Type | D | TeSys serie D (Domestic high-current type) |
| Corrente nominale | 115 | Rated operational current 115A (AC-3, ≤440 V) |
| Contatti ausiliari | 0 | Configurazione standard: 1NO + 1Contatti ausiliari NC |
| Coil Rating | M | 220VAC coil voltage |
| Codice di frequenza | 7 | Universal coil for 50/60Hz |
| Manufacturing Code | C | Manufactured by SSIC (allineare: 9~620A) |
Modello completo: LC1D11500M7C (official standard model), Abbreviated Model: LC1D115M7C
- Specifiche principali
| Categoria | Dettagli |
| Parametri di base | 3-palo (3P), 3NESSUN contatto principale, 1Contatti ausiliari NA+1NC, collegamento con terminale a vite |
| Corrente nominale | AC-1: 200UN (≤440 V, ≤60°C); AC-3: 115UN (≤440 V, ≤60°C) |
| Tensione nominale | Circuito principale: ≤1000VAC; Circuito di controllo: 220VCA, 50/60Hz |
| Motor Control Rating | 30kW (220~230V), 55kW (380~400V), 75kW (500V) |
| Vita meccanica | 10 milioni di operazioni (AC-3), 10 milioni di operazioni (AC-1) |
| Vita elettrica | 1 million operations at rated current (AC-3), 1 million operations at rated current (AC-1) |
| Caratteristiche della bobina | Pick-up power: 1200VA; Detenere il potere: 120VA; Impedance: 0.6MΩ |
| Montaggio | 35mm DIN rail mounting or direct panel mounting |
| Dimensioni & Peso | Altezza: 158mm; Larghezza: 120mm; Profondità: 136mm; Peso: ca. 2.5kg |
| Classe di protezione | IP20 (per IEC 60529) |
| Certificazioni | UL, CSA, CEI, CCC, EAC, Marino, RINA, DNV, ecc. |
- Elenco completo dei modelli (LC1D Series 115A)
| Modello | Tensione della bobina | Tipo di terminale | Osservazioni |
| LC1D11500M7C | 220VCA | Vite | Tipo standard (original model) |
| LC1D11500P7C | 380VCA | Vite | Common alternative voltage |
| LC1D11500F7C | 110VCA | Vite | Low voltage control |
| LC1D11500B7C | 24VCA | Vite | Safety extra-low voltage control |
| LC1D115006M7C | 220VCA | Ring terminal | For special wiring requirements |
| LC1D115KUEC | 100~250VAC/DC | Vite | Voltaggio universale, replacement model |
| LC1D115ABD | 24VCC | Vite | Versione con bobina CC |
| LC1D115ALBD | 24VCC | Vite | Low-power DC coil |
- Attraverso & Replacement Model List
4.1 Sostituzioni originali Schneider
| Modello originale | Modello sostitutivo | Motivo della sostituzione | Compatibilità |
| LC1D115M7C | LC1D115KUEC | Universal voltage coil (100~250VAC/DC), higher flexibility | Pienamente compatibile, identical mounting dimensions |
| LC1D115M7C | LC1E120M5N | Upgraded TeSys E Series with improved performance | Identical mounting dimensions; verify auxiliary contact configuration |
| LC1D115M7C | LC1D11500M7C | Full official model, identical to abbreviated version | 100% compatibile |
4.2 Sostituzioni tra marchi diversi
| Marca | Modello sostitutivo | Principali differenze | Applicability |
| ABB | A145-30-11 | Rated current 145A with larger margin | Different mounting dimensions; layout adjustment required |
| Siemens | 3RT2036-1BB40 | 125UN, AC-3, 220Bobina V | Same auxiliary contact layout, sostituzione diretta |
| Interruttore Changshu | CJX2-1210 | Alternativa domestica, conveniente | Slightly lower performance, for general working conditions |
| Cinto | NC1-1210 | Alternativa domestica, prestazione ad alto costo | Meets basic requirements, shorter service life |
- Applicazione & Casi di settore
5.1 Scenari applicabili
Controllo motorio: Inizio, stop and reverse control for 30~75kW three-phase squirrel-cage motors
Automazione industriale: Control circuits for production lines, trasportatori, compressors and pumps
Distribuzione dell'energia: Switching control for non-inductive or weakly inductive loads such as resistance furnaces and heaters (AC-1)
Sistemi HVAC: Control of large air conditioning compressors and ventilation fans
Marino & Offshore Engineering: Certified by marine classification societies for offshore equipment
5.2 Scenari non consigliati
High-Frequency Operation: Più di 120 starts/stops per minute (use LC1D170 series or dedicated contactors)
Ambienti difficili: Polvere pesante, corrosive gas or severe vibration (additional protection required)
DC Loads: Use dedicated DC contactors (per esempio. LC1D115ABD)
High Altitude: Derating required above 2000m (10% derating per additional 1000m)
5.3 Casi applicativi tipici
Caso 1: Fan Control in Steel Plant
Operating conditions: 380V, 55kW fan, AC-3, 10 starts per day, 20-hour continuous operation
Soluzione: LC1D115M7C + LRD3365 thermal overload relay
Vantaggi: 3 years of stable operation without failure, basso costo di manutenzione
Caso 2: HVAC System in Pharmaceutical Factory
Operating conditions: 400V, 45kW compressor, AC-3, 24-hour continuous operation and frequent cycling
Soluzione: LC1D115M7C + Controllo PLC + soppressore di sovratensioni
Vantaggi: Low noise and power consumption, compliant with GMP standards
- Risoluzione dei problemi & Maintenance Manual
6.1 Common Fault Diagnosis
| Fenomeno di guasto | Possibili cause | Soluzioni |
| Il contattore non si chiude | 1. No voltage on coil; 2. Bobina bruciata; 3. Inceppamento meccanico | 1. Measure voltage across terminal A1/A2; 2. Controllare la resistenza della bobina (normale: ca. 320OH); 3. Spegnimento, inspect mechanism and remove foreign objects |
| Loud noise after closing | 1. Sottotensione; 2. Oil contamination on core contact surface; 3. Anello di ombreggiatura rotto | 1. Ensure voltage within ±10% of rated value; 2. Clean core surface; 3. Sostituire il gruppo bobina |
| Overheated / burnt main contacts | 1. Overload current; 2. Contatto scarso; 3. Failed arc suppression | 1. Check for load overload; 2. Clean or replace contacts; 3. Inspect arc chute integrity |
| Auxiliary contact malfunction | 1. Ossidazione da contatto; 2. Cablaggio allentato; 3. Mechanical wear | 1. Contatti puliti; 2. Stringere nuovamente i terminali; 3. Replace auxiliary contact block |
| Repeated coil burnout | 1. Forti fluttuazioni di tensione; 2. Frequent cycling; 3. Excess ambient temperature | 1. Installare lo stabilizzatore di tensione; 2. Replace with high-cycle model; 3. Improve heat dissipation |
6.2 Programma di manutenzione & Procedures
| Articolo di manutenzione | Intervallo | Operazione |
| Ispezione visiva | Mensile | Check for overheating marks, abnormal odors and loose parts |
| Contatta l'ispezione | Trimestrale | Misurare la resistenza di contatto (<50m惟), check for ablation |
| Ispezione della bobina | Semestrale | Measure coil resistance and insulation performance |
| Mechanical Lubrication | Annualmente | Lightly lubricate moving parts (silicone grease recommended) |
| Overhaul | Ogni 2 anni | Disassemble for full inspection, replace worn parts and clean interior |
- Phase-Out & Migration Guide
7.1 Phase-Out Information
Phase-out Plan: Schneider launched the phase-out of domestic high-current TeSys D series (115-170UN) in July 2025
Transition Period: July 2025 – December 2026. Production will cease after the period
Inventory: Stock is still available via some distributors. Procurement or model replacement is recommended as soon as possible.
7.2 Migration Solutions
| Migration Type | Modello consigliato | Vantaggi | Note |
| In-Series Upgrade | LC1D115KUEC | Universal voltage coil for wider application | Identical mounting size, no cabinet modification needed |
| Cross-Series Upgrade | LC1E120M5N | TeSys E Series with enhanced performance and longer service life | Auxiliary contact layout may differ; verify control circuit |
| Cost-Saving Replacement | Changshu CJX2-1210 / Chint NC1-1210 | 30-50% riduzione dei costi | Slight performance difference; for non-critical applications |
7.3 Migration Steps
- Confirm voltage and current requirements of the original control circuit
- Select suitable replacement model (LC1D115KUEC recommended)
- Verify compatibility of mounting dimensions and fixtures
- Confirm quantity and type of auxiliary contacts
- Replace contactor and conduct commissioning test
- Keep spare parts of the original model until the end of transition period
- Linee guida per la selezione
Regole di riferimento rapido
- LC1D: Schneider TeSys D series contactor
- 115: 115Una corrente nominale (AC-3), matches 55kW motor at 400V
- M7C: 220VAC 50/60Hz coil, manufactured by SSIC
- 00: Standard 1NO+1NC auxiliary contacts
- Phase-out Notice: Prioritize LC1D115KUEC for replacement since July 2025
- Conformità del trasporto aereo & Certificazioni
Transport Classification: Merci non pericolose. Nessuna batteria al litio integrata / supercapacitor, compliant with IATA regulations
Certificazione CE: Conforme alla norma EN 60947-4-1, CE marked
Certificazione Ambientale: Compliant with RoHS/REACh directives, Prodotto verde premium
Confezione: Individual packaging to prevent damage during transit. Original packaging is recommended.