注文コード: 3AUA0000058188 Lifecycle Status: 廃止 (Classic Maintenance Phase). Spare parts available, long lead-time for new stock; upgrade to ACS380 series is recommended. Type Code Decoding ACS355-03E-07A3-4 Field Description ACS355 ABB Machinery Drive Series 3 Three‑phase AC power supply input E Built‑in 50Hz EMC RFI filter 07A3 Continuous rated output current 7.3 あ 4 電圧クラス: ...

  • 製品詳細

注文コード: 3AUA0000058188

ライフサイクルステータス: 廃止 (Classic Maintenance Phase). Spare parts available, long lead-time for new stock; upgrade to ACS380 series is recommended.

  1. Type Code Decoding

ACS355-03E-07A3-4

分野説明
ACS355ABB Machinery ドライブ シリーズ
3Three‑phase AC power supply input
EBuilt‑in 50Hz EMC RFI filter
07A3Continuous rated output current 7.3 あ
4電圧クラス: 380‑480 VAC three‑phase
  1. コア電気 & 機械仕様
アイテムパラメータ
Typical motor power rating3.0 kW (400 V three‑phase)
Rated output current I₂N7.3 あ
Input power supplyThree‑phase 380‑480 V ±10%, 48‑63 Hz
侵入保護IP20 (cabinet‑mount installation)
フレームサイズR1
出力周波数0‑600 Hz, ベクター / V/F制御
過負荷機能150% I₂N for 1 min per every 10 min; 180% I₂N peak for 2 s at start‑up
スイッチング周波数4 kHz (デフォルト); adjustable from 4 kHz to 16 kHz
Built‑in functionsSTO Safe Torque‑Off, integrated brake chopper, 8‑step sequence programming, FlashDrop fast parameter download
全体の寸法 (幅×高さ×奥行き)70 mm × 239 mm ×161 mm
正味重量1.8 kg
Standard delivery scopeControl panel NOT included; panel must be ordered separately
  1. Hardware Interface & Native I/O
  2. デジタル入力: 6 から; デジタル出力: 1 する; リレー出力:1 リレー
  3. アナログ入力:2 AI; アナログ出力:1 へ
  4. Native RS-485 (Modbus RTU); supports plug-in fieldbus option modules
  5. Dual-channel hardware STO safety terminals (compliant with machinery safety standards)
  6. Power terminals: L1/L2/L3 power input; U/V/W motor output; BR+ BR-brake resistor terminals; PE protective earth

⚠️ Brake resistor NOT supplied as standard; brake resistor is an external optional accessory.

  1. 包装内容明細書

✅ Items included in standard package:

  1. 1 × ACS355-03E-07A3-4 main unit
  2. I/O control terminal blocks, power terminals, mounting screw kit
  3. Paper-format installation manual & quick-start guide
  4. Paper mounting cutout template

❌ NOT included in standard delivery; must be ordered separately:

コントロールパネル: ACS-CP-A (Advanced panel J400), ACS-CP-C (Basic panel J404)

Fieldbus modules: FPBA-01 (プロフィバス-DP), FENA-01 (イーサネット/IP / プロフィネット), FMBA-01 (Modbus RTU), 等.

I/O expansion module MREL-01; encoder interface module MTAC-01

External brake resistor, panel extension cable, FlashDrop tool

  1. Compatible Replacement & アップグレードソリューション

Original model is obsolete; two selection scenarios below:

オプション 1: Upgrade to ABB ACS380-04-09A5-4 (3 kW,9.5 あ)

利点: New-generation machinery drive, 充実した機能, hardware STO supported, parameter migration tool available

⚠️ Notice: Terminal layout and cabinet mounting cutouts are NOT fully compatible. Cabinet modification is required. I/O definitions differ. Direct plug-and-play replacement is impossible. Rewiring, parameter conversion and commissioning are mandatory.

オプション 2: Spare-part stock of original ACS355-03E-07A3-4

利点: 同一の取り付け, 配線とパラメータ; direct drop-in replacement

短所: Limited stock, high unit price, long lead-time; classified as obsolete legacy spare-part stock.

  1. 典型的なアプリケーションシナリオ

OEM machinery supporting: コンベア, 包装機械, textile equipment, woodworking machines, food-beverage processing equipment, small-size pumps & ファン, simple lifting mechanisms and general-purpose variable-speed applications.

  1. 選定メモ & Application Boundary Conditions
  2. 周囲温度: Full-rating operation from 0 °C to +40 °C; derating required above 40 °C. Condensation, corrosive gas and heavy dust are prohibited. IP20 rating permits cabinet-only installation; direct field exposure is forbidden.
  3. This unit is factory-fitted with EMC filter. If input line reactor is added, ensure proper filter earthing.
  4. For heavy-duty cycles with frequent shock loading, select according to actual motor operating current instead of nominal power rating. If actual motor current exceeds 7.3 A, select the next higher drive frame size.
  5. Brake chopper is built-in; brake resistor must be externally fitted. Select brake resistor strictly per manual specifications. Never short-circuit BR terminals.
  6. For valid STO safety function in production operation, both STO channels shall be wired; single-channel short-circuit is prohibited.
  7. Important Maintenance Guidelines

Service life of R1-frame cooling fan: 約. 3 years; fan replacement is recommended upon expiry.

Retorque power terminals every 6 years.

Annual functional verification test for STO safety function is recommended.

Application Fields of ABB ACS355-03E-07A3-4 (3 kW) 頻度 コンバータ

This is a compact OEM-oriented vector drive with IP20 cabinet-mount rating. It comes with built-in STO Safe Torque-Off, integrated EMC filter and built-in brake chopper. It targets general-purpose variable-speed control for small-to-medium-power stand-alone OEM machinery, and is not intended for heavy-duty continuous high-power drive cycles.

  1. 包装 & Material-Handling Industry

ベルトコンベア, roller conveyors, chain conveyors, sorting equipment

Wrapping machines, case sealers, strapping machines, auxiliary palletizing mechanisms

特徴: Frequent start-stop cycles, smooth speed regulation; STO safety function supports machine safety protection.

  1. 木工機械

Wood cutting machines, sanders, multi-axis milling machines, saws

Material feed mechanisms for wood processing

Strengths: 0-600 Hz high-frequency output for high-speed spindles; on-board 8-step sequence programming reduces external PLC hardware requirement.

  1. 繊維機械

Small-scale spinning & weaving auxiliary feeders, 巻線機, sizing-machine auxiliary drives

要件: Stable low-speed torque, tension-control capability; suitable for light-to-medium-duty winding tasks.

  1. 食べ物 & Beverage Processing Equipment

Small mixing-tank drives, conveyor chains, filling-lines, ラベラー, sorting machines

注記: The drive must be installed inside electrical cabinets. Direct exposure to wash-down / humid environments is not allowed; proper cabinet environmental protection is required.

  1. パンプス & ファン (空調設備 & 水処理)

Process circulation pumps, water-supply pumps, small centrifugal fans, 排気ファン

述べる: Pumps and fans belong to quadratic-torque loads. This drive is applicable; しかし, dedicated fan-pump drives are preferred for large-capacity energy-saving projects.

  1. Plastics & Rubber Machinery Auxiliary Equipment

Feeder units, コンベヤーベルト, small extruder auxiliaries, take-up & pay-off mechanisms

⚠️ NOT recommended for main injection-molding pump drives: Severe shock-loading exceeds the drive’s overload margin.

  1. マテリアルハンドリング & Light Lifting Equipment

Light-duty elevators, auxiliary travelling mechanisms for small hoists, small lifting platforms

❗Critical boundary condition: For lifting applications, external brake resistor must be fitted and brake chopper enabled. Operation without brake resistor for lowering loads is strictly forbidden.

  1. General-Purpose Machine-Tools & Small Processing Equipment

Small grinders, feed drives, small spindle drives.

❌ Non-applicable Conditions (Selection Pitfalls)

  1. Outdoor direct installation (IP20; cabinet-mount only).
  2. Direct exposure to corrosive atmosphere, heavy conductive dust, condensation or moisture.
  3. Heavy-shock high-duty-cycle main drives (例えば. main injection-molding pumps, large winches).
  4. Field wall-mount installation requiring IP54 / IP65 high-protection rating.

Unit Application Matching Key Points

ACS355-03E-07A3-4 (3 kW /7.3 A) is intended for continuous rated load ≤3 kW motors. 150% overload for 1 min is specified for standard OEM machinery. For applications with frequent shock overload, select one power frame higher.

Full Detailed Parameters of ABB ACS355-03E-07A3-4

注文コード: 3AUA0000058188; Frame size R1; 廃止, spare-part maintenance supply only.

  1. Type-code Explanation
コードセグメント意味
ACS355ABB OEM Machinery Drive Series
3Three‑phase AC power input
EBuilt‑in C3‑class EMC RFI filter
07A3Continuous output rated current 7.3 A
4Voltage rating: 380‑480 V three‑phase
  1. Main Electrical Ratings
アイテム価値
Typical asynchronous motor power3.0 kW @400 V three‑phase
Rated output current I₂N7.3 あ
入力電圧Three‑phase 380‑480 VAC ±10%
入力周波数48‑63 Hz
出力電圧0 ~ supply voltage (three‑phase)
Output frequency range0‑600 Hz (センサレスベクトル制御)
過負荷機能150% I₂N for 1 min per every 10 min; 180% I₂N peak for 2 s on start‑up
スイッチング周波数Default 4 kHz; optional 4/8/12/16 kHz; derating required at high switching frequencies
Control modesScalar V/F, センサーレスベクトル; supports asynchronous & permanent‑magnet motors
Built‑in brake chopper ✅標準; brake resistor is external
STO Safe Torque‑Off ✅Dual‑channel hardware; SIL3 / PL e (ISO 13849‑1) 認定された
Drive efficiencyApprox.97% under rated load
DC bus voltage540 Vdc ±15%
  1. I/O Terminal Specifications

Native I/O fitted; no mandatory expansion card required. Control panel is optional, not factory-supplied.

信号の種類量 & 仕様
DI デジタル入力6 チャンネル; PNP/NPN compatible; 12‑24 VDC; impedance 2.4 kΩ; pulse‑input capable:0‑16 kHz
デジタル出力DO1 channel transistor output; max 30 VDC,100 ミリアンペア, short‑circuit protected; max pulse‑output frequency 16 kHz
Relay Output REL1 チャネル; contact rating max 250 VAC 5 A;30 VDC 0.5 A; AC/DC compatible relay contact
Analog Input AI2 チャンネル; configurable ‑10~+10 V voltage /‑20~20 mA current; AI1 impedance >312 kΩ (voltage mode),100 Ω (current mode)
アナログ出力AO1 チャネル;0‑20 mA, max driving load 500 Ω
Auxiliary 24 V output24 VDC ±10%, max 200 mA; for DI & external sensor power supply
On‑board communicationEmbedded EFB Modbus‑RTU (RS485); compatible with FPBA‑01, FENA‑01 and other fieldbus option modules
Safety terminalsX1C dual‑channel STO hardware safety terminals
  1. 機械式 & Outline Data
アイテムR1 Frame ACS355‑03E‑07A3‑4
侵入保護IP20 (cabinet‑internal installation); NEMA Open
取り付けDIN‑rail mounting / screw‑fixed panel mounting
Overall W×H×D70 mm ×239 mm ×161 mm (including mounting clips)
正味重量1.8 kg
Package dimensions220 mm ×130 mm ×350 mm; single‑unit carton
冷却Integrated axial cooling fan; typical fan service life ~3 years
  1. 環境条件
アイテム仕様
使用周囲温度0 … +40 °C full rating; derating above 40 °C; maximum permissible 50 °C (derated); icing and condensation prohibited
保管温度‑40 … +70 °C
高度Full rating up to 1000 m above sea level; derate 1 % per additional 100 m above 1000 m; maximum operating altitude 2000 m
汚染度Operation class 2C2; direct exposure to conductive dust or corrosive gas is forbidden
振動IEC 60068‑2‑6: 10‑57 Hz amplitude 0.25 mm; 57‑150 Hz 2 g
ショックTransport:15 g 11 ms; オペレーティング:2 g
  1. 認証 & コンプライアンス

CE, UL/cUL, RCM(C-Tick), EAC(GOST-R), RoHS; compliant with Low-Voltage, EMC and Machinery Directives

STO safety function: SIL3 IEC 61508, PL e ISO 13849-1

Built-in E-filter meets C3 industrial-grade EMC requirements

  1. Built-in Function List
  2. 8-step on-board sequence programming for reduced external PLC hardware
  3. FlashDrop fast parameter copy tool support
  4. Motor thermal-protection, 過電流, 過電圧, 不足電圧, earth-fault and output-short-circuit protection
  5. Stall protection, mechanical-brake control, PIDレギュレータ
  6. Speed-compensated stop, DC-braking, flux-braking
  7. Multiple parameter-set switching
  8. Complete fault-history logging, maintenance counters (fan runtime, power-on hours)
  9. Power Terminal Definition
ターミナル関数
L1 L2 L3Three‑phase AC power input
U V WThree‑phase motor output
BR+ BR‑Brake‑resistor connection (chopper built‑in; resistor external)
PE保護接地端子

⚠️ Do NOT short-circuit BR+ and BRterminals. Brake resistor must be selected strictly according to manual specifications.

  1. Option List (Not factory-supplied; order separately)
  2. コントロールパネル: ACS-CP-A advanced panel, ACS-CP-C basic panel
  3. Fieldbus modules: FPBA-01 プロフィバス-DP; FENA-01 PROFINET/EtherNet-IP; FMBA-01 Modbus-RTU
  4. I/O expansion MREL-01; encoder interface MTAC-01
  5. External brake resistor, panel extension cable, FlashDrop tool
  6. Application Boundary Notes
  7. IP20 rating permits cabinet-mount installation only; not suitable for wash-down or humid field environments.
  8. Lifting-load applications require external brake resistor and activation of built-in brake chopper.
  9. Current derating is mandatory for ambient temperature 40 °C and altitude 1000 m.
  10. Legacy obsolete model; spare-part stock availability is limited. Upgrade to ACS380-04-09A5-4 requires cabinet modification and full rewiring.