オムロン K8DS series slim three-phase voltage + phase-reversal & phase-loss monitoring relays deliver integrated protection for industrial 3-wire three-phase power systems. A single unit monitors four major faults simultaneously: 過電圧, 不足電圧, phase loss and phase reversal. Featuring enhanced anti-interference performance against inverters, it supports adjustable wide industrial voltage ranges from 380V to 480V. Adopting a slim 17.5mm standard DIN rail housing, it drastically cuts cabinet installation space. Widely installed on the power supply side of power equipment including three-phase asynchronous motors, ウォーターポンプ, air compressors and conveyor lines, it prevents equipment damage and production downtime caused by grid abnormalities.
Step-by-Step Model Code Breakdown
フルモデル: `K8DS-PM2`
- K8DS: Series code for OMRON slim monitoring relays, corresponding to the 17.5mm DIN rail mounting form factor
- 午後: Function type code, representing combined functions of three-phase voltage monitoring, phase reversal detection and phase loss detection
- 2: Voltage grade code, matching 3-wire three-phase AC380/400/415/480V input specifications (サフィックス “1” stands for AC200~240V grade)
主要な技術仕様
| パラメータのカテゴリ | パラメータ項目 | 詳細仕様 |
| 入力特性 | 定格入力電圧 | 3-wire three-phase: AC380V / 400V / 415V / 480V (selectable via rotary switch) |
| Input Frequency | Universal for 50Hz / 60Hz | |
| Rated Input Power Consumption | 約. 2.8バージニア州 | |
| Voltage Adjustment Range | 過電圧: -30% ~ +25% 定格価値の | |
| 不足電圧: -30% ~ +25% 定格価値の | ||
| Reset Hysteresis | Fixed at 5% of actuation value, auto-reset mode | |
| Actuation Time | Over/Undervoltage Delay | Continuously adjustable from 0.1s to 30s |
| Phase Reversal Detection Time | 0.1s ± 0.05s | |
| Phase Loss Detection Time | ≤0.1秒 | |
| Power-Up Blocking Time | 1s ± 0.5s | |
| 出力特性 | Output Contact Form | 1 切替接点 (1c / SPDT) |
| Rated Contact Capacity | AC250V 5A (抵抗負荷); DC30V 5A | |
| Contact Mechanical Service Life | 1,000万回以上の操作 | |
| 機械式 & 取り付け | 取付方法 | 標準DINレール取付 |
| Unit Width | 17.5mm | |
| 配線方法 | ネジ締め端子 | |
| ステータス表示 | 4 LED indicators for Power, 過電圧, Undervoltage and Fault | |
| 環境 & 認証 | 動作周囲温度 | -20℃~60℃ |
| 保管温度 | -40℃ ~ 85℃ | |
| 侵入保護評価 | IP20 (with terminal cover fitted) | |
| コンプライアンス認証 | CE, UL, CSA certified |
Cross Reference of Same Series Models
- Same Function, Different Voltage Grades
| フルモデル | 定格入力電圧 | 該当するシナリオ |
| K8DS-PM1 | 3-wire three-phase AC200/220/230/240V | Low-voltage three-phase systems, supporting imported equipment |
| K8DS-PM2 | 3-wire three-phase AC380/400/415/480V | Standard domestic industrial three-phase systems, export machinery |
- Full K8DS Series Function Comparison
| モデル | 主要な監視機能 |
| K8DS-PH | 位相反転 + phase loss detection only |
| K8DS-PM | 過電圧 + 不足電圧 + 位相反転 + 位相損失 |
| K8DS-PA | Three-phase unbalance + 位相反転 + 位相損失 |
| K8DS-PU | 不足電圧 + 位相反転 + 位相損失 |
| K8DS-PZ | 過電圧 + 不足電圧 + 三相アンバランス + 位相反転 + 位相損失 |
典型的なアプリケーションシナリオ
- Front-end Protection for Three-Phase Asynchronous Motors: Connected in series to the control circuit of the main circuit contactor for real-time power supply status monitoring. It instantly cuts off the control circuit upon phase loss or phase reversal to avoid motor burnout, ideal for long-running power equipment such as fans, ウォーターポンプとエアコンプレッサー.
- Incoming Power Monitoring for Control Cabinets: Mounted at the incoming side of power distribution cabinets to monitor voltage quality of the entire cabinet’s three-phase supply. It outputs alarm signals for overvoltage or undervoltage faults to trigger sound-light alarms or upper monitoring systems.
- Front-End Power Protection for Inverters: Designed with enhanced anti-inverter interference capability, it is installed on the input side of inverters to detect grid voltage abnormalities and protect inverter rectifier modules against surges and phase loss damage.
- Conveying Systems for Automated Production Lines: Matched with conveyor and roller motor groups to uniformly monitor three-phase phase sequence and voltage, preventing production accidents caused by reversed equipment operation due to wrong phase sequence wiring.
- Protection for Central Air Conditioning & 冷凍ユニット: Installed in the power supply circuit of compressors for commercial buildings and industrial refrigeration to monitor three-phase power conditions and ensure safe operation of refrigeration compressors.
Common Troubleshooting Matrix
| 故障現象 | Root Cause Analysis | Step-by-Step Solutions |
| Power indicator off, relay no response | 1. Missing phase at three-phase incoming lines or loose wiring | 1. Measure L1/L2/L3 three-phase line voltages to confirm they fall within the rated 380~480V range |
| 2. Input voltage out of rated range | 2. Tighten terminal wiring and inspect upstream circuit breakers and fuses | |
| 3. Damaged internal power circuit of the module | 3. Replace the module for hardware troubleshooting if voltage is normal yet no indicator lights up | |
| Three-phase voltages normal, fault light stays on and output actuates | 1. Reversed phase sequence triggers phase reversal protection | 1. Verify L1/L2/L3 phase sequence matches terminal marking |
| 2. Over/undervoltage set thresholds are too low | 2. Adjust overvoltage and undervoltage threshold knobs to match actual on-site voltage range | |
| 3. Excessive three-phase voltage unbalance | 3. Measure three-phase line voltage differences to eliminate severe unbalance issues | |
| Relay fails to actuate during voltage abnormalities | 1. Overlong actuation delay setting | 1. Turn down the over/undervoltage delay knob to shorten protection response time |
| 2. Fault duration shorter than configured delay | 2. Check deviation between set thresholds and actual voltage to confirm fault magnitude exceeds actuation limits | |
| 3. Voltage fluctuation fails to reach set threshold | 3. Monitor voltage fluctuations with a multimeter to verify protection trigger conditions are met | |
| Relay fails to reset after voltage returns to normal | 1. Fault not fully eliminated with latent phase loss/voltage anomalies remaining | 1. Continuously monitor three-phase voltages until all phases fully recover and stabilize |
| 2. Contact adhesion or mechanical jamming | 2. Power cycle the unit to test normal relay reset performance | |
| 3. Power off and measure contact continuity to rule out adhesion; replace the module if necessary |
Typical Application Scenarios of OMRON K8DS-PM2
As a slim four-in-one three-phase monitoring relay integrating overvoltage, 不足電圧, phase loss and phase reversal protection, the K8DS-PM2 is positioned as an economical power protection device for industrial three-phase power loads. Its applications fall into three core categories: three-phase load protection, power quality monitoring, and anti-interference drive matching, 詳細は次のとおりです:
- Front-End Protection for General Three-Phase Power Loads (Most Widely Used)
This is the dominant basic application of the model, providing power-side fault protection for all types of three-phase inductive loads and serving as a direct replacement for traditional single-function phase sequence relays.
- Body Protection for Three-Phase Asynchronous Motors
取付位置: Connected in series to the coil control circuit of the motor main circuit contactor, or wired to PLC emergency stop interlock input terminals
Core Problems Solved: Overheating and burnout of motor windings from phase-loss operation; mechanical accidents from reversed equipment rotation due to wrong phase sequence; accelerated insulation aging and shortened service life under sustained over/undervoltage
Typical Compatible Equipment: General power equipment including fans, ウォーターポンプ, エアコンプレッサー, 破砕機, machine tool spindles and lifting motors
アプリケーションの価値: Fast 0.1s-level response for phase loss and phase reversal, directly cutting the control circuit upon faults. Single-unit protection cost is far lower than motor repair and production downtime losses.
- Specialized Protection for Industrial Pumps
取付位置: Incoming side of electrical control boxes for centrifugal pumps, submersible pumps, screw pumps and other pump equipment
Core Problems Solved: Pump overload burnout caused by phase loss; damaged mechanical seals and bearings plus out-of-control pipeline pressure from impeller reverse rotation due to reversed phase sequence
Typical Applicable Scenarios: Cooling circulation water pumps, 化学プロセスポンプ, hydraulic station oil pumps, water supply and drainage pump sets
アプリケーションの価値: Adjustable 0.1~30s delay avoids false shutdowns from short-term grid voltage sags while guaranteeing reliable actuation under severe faults.
- Supporting Protection for Inverter & Drive Systems (Differentiated Advantage Scenarios)
Equipped with enhanced harmonic and electromagnetic interference resistance, the K8DS-PM2 can be directly installed inside inverter cabinets, making it highly suitable for inverter drive applications.
- Power Protection on Inverter Input Side
取付位置: Main circuit incoming terminals of inverters, DIN rail mounted inside inverter cabinets
Core Problems Solved: Damage to inverter rectifier modules and DC bus capacitors from grid phase loss or sharp voltage surges/drops; false alarms and misoperation of ordinary phase sequence relays under harmonic interference
Typical Applicable Scenarios: Variable-speed fan & pump systems, production line inverter drive systems, air compressor inverter retrofitting projects
アプリケーションの価値: Tolerates high-order harmonics generated by inverters for stable operation without misactuation, while safeguarding core power components of inverters.
- Power Monitoring for Soft Starters & Servo Drive Systems
取付位置: Incoming side of soft starters, main power inlet of multi-axis servo control cabinets
Core Problems Solved: Drive failures from instantaneous voltage dips during equipment startup; thyristor burnout of soft starters caused by phase loss
アプリケーションの価値: Wide voltage tolerance accommodates voltage fluctuations during startup, with a built-in 1s power-up blocking function to prevent false protection triggering at power-on.
Ⅲ. Industry-Specific Engineering Application Scenarios
- 冶金 & Mining Industry
Power cabinets for belt conveyors and scraper conveyors: Mass monitoring of power supply status for multiple drum motors to prevent full production line shutdown from single motor burnout due to phase loss
Control circuits for ball mills and vibrating feeders: Withstands grid surges and voltage fluctuations generated by startup/shutdown of large plant equipment
Hoist and winch drive systems for mining: Phase reversal protection eliminates risks of reversed lifting direction, complying with mine safety regulations.
- 化学薬品 & 製薬産業
Agitator motors and metering pump sets for reaction kettles: Ensures stable power supply for continuous production processes, triggering process interlock shutdown upon faults to avoid material scrapping and safety incidents
Purified water & water-for-injection circulation systems: Stable power supply guarantees compliant water quality for pharmaceutical processes and prevents scrapped production batches due to power anomalies
Cabinets for hazardous explosion-proof areas: Compliant with industrial EMC standards, compatible with explosion-proof control cabinets to monitor three-phase power integrity.
- Municipal & 水処理産業
Water plant delivery pump houses and booster pump stations: Uniformly fitted to multiple pump units to guarantee uninterrupted urban water supply and fast switchover to standby pumps during faults
Aeration fans and sludge dewaterers in sewage treatment plants: Adapts to voltage drops and mild three-phase unbalance from long-distance power supply within plants
Municipal flood drainage pump stations: Prevents pump equipment failure from phase loss or overvoltage under heavy-load operation in rainy seasons to secure drainage capacity.
- 工事 & Building Industry
Chilled water units and cooling tower fans of central air conditioning: Protects main compressor motors and avoids damaged valve plates from reversed compressor rotation caused by wrong phase sequence
Fire water pumps and smoke exhaust fans: Meets fire code requirements for terminal power monitoring and ensures reliable operation of fire-fighting loads
Power circuits for elevators and escalators: Monitors supply phase sequence and voltage quality to eliminate safety hazards from power system faults.
- ロジスティクス & 自動生産ライン
Roller conveyor and sorting machine motor groups: Unified power monitoring for full production lines to prevent material collision accidents from reversed conveying direction due to on-site wiring phase sequence errors
Stacker and shuttle car systems for automated warehouses: Guarantees reliable power supply to avoid damage to precision logistics equipment from power anomalies
OEM packaging & filling production lines: Slim 17.5mm design fits compact small control cabinets and significantly saves internal cabinet space.
- Supporting Equipment for Complete Machinery & Export Projects
- Incoming Power Monitoring for MCC / PLC Cabinets
Installed at the power inlet of motor control centers and automated control cabinets to monitor three-phase power status for the entire cabinet. Relay output contacts can be linked with sound-light alarms or upper SCADA systems. Four LED indicators enable on-site rapid identification of fault types (過電圧 / 不足電圧 / 位相損失 / 位相反転).
- Standard Matching for Export Equipment
Supports four selectable voltage grades (380V/400V/415V/480V) to fit grid standards across China, 欧州連合, 東南アジア, the Middle East and other regions. Fully certified with CE, UL and CSA international approvals to meet export machinery compliance requirements, covering global projects with a single model.
- Terminal Protection for Diesel Generator Sets
Mounted on the load output side of diesel generators to monitor output voltage stability and phase sequence, preventing damage to downstream precision loads caused by abnormal generator voltage regulation or reversed phase sequence wiring.
コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池






















NH42-63-318x560.png)