Schneider 3CT-H3-300-C Integrated 3-Phase Current Transformer

The 3CT-H3-300-C is a through-core combined three-phase current transformer of Schneider’s 3CT series (formerly Samwha from South Korea). It is specially developed to match the EOCR series motor protectors. Adopting an integrated three-phase synchronous sampling structure, it is designed for current collection on the main circuit of three-phase motors, meeting demands for motor protection against ...

  • 製品詳細

The 3CT-H3-300-C is a through-core combined three-phase 変流器シュナイダー’s 3CT series (formerly Samwha from South Korea). It is specially developed to match the EOCR series motor protectors. Adopting an integrated three-phase synchronous sampling structure, it is designed for current collection on the main circuit of three-phase motors, meeting demands for motor protection against overload, phase loss and locked rotor as well as current measurement. Equipped with circular through holes for cable threading and compatible with standard 35 mm DINレール取付, it greatly saves cabinet wiring and installation space.

  1. Step-by-Step Model Code Decoding

3CT-H3-300-C

  1. 3CT: Integrated 3-Phase Current Transformer
  2. H3: Frame code corresponding to primary current rating of 300 あ
  3. 300: Rated primary current 300 あ
  4. C: Circular through-hole structure; models with suffix Z in the same series feature square holes for busbar application

Ⅲ. 主要な技術仕様

アイテムパラメータ値
Current Ratio300/5 あ
Rated Burden1.25 バージニア州
精度クラス保護クラス 3.0
Through-hole DiameterCircular 24 mm
耐電圧2 kV power frequency withstand voltage, maximum circuit voltage withstand 1150 V
Phase ConfigurationIntegrated 3-phase, synchronous sampling for three circuits
取付方法Fixed on standard 35 mm DINレール
全体の寸法W 150 mm * H 71 mm
Compatible CablesCopper cables (single-core / multi-strand through-core wiring)
Matched EquipmentFull range of Schneider EOCR motor protectors (EOCR-SS / 3DE / FM, 等)
Core MaterialNanocrystalline alloy, low-distortion sampling for 50 Hz ~ 1 kHz
  1. Full Model Cross Reference for the Same Series
モデルRatioThrough-hole Structure
3CT-H1-100-C100/5 あType C with circular hole
3CT-HH-150-C150/5 あType C with circular hole
3CT-H2-200-C200/5 あType C with circular hole
3CT-H3-300-C300/5 あType C with circular hole
3CT-H4-400-C400/5 あType C with circular hole
3CT-H3-300-Z300/5 あType Z with square hole (for busbar only)
  1. 典型的なアプリケーションシナリオ
  2. Complete control cabinets for industrial three-phase asynchronous motors, cooperating with EOCR protectors to realize protection against overload, 位相損失, phase unbalance and locked rotor;
  3. Current monitoring of 0.4 kV low-voltage power circuits, sampling for ammeters and multi-function meters;
  4. Control boxes for high-power motors such as water pumps, ファン, air compressors and conveyors;
  5. Complete electrical control systems for automatic production lines, HVAC equipment and water treatment facilities.
  6. インストール & Operation Maintenance Key Points
  7. Thread the three primary-side cables separately through the three circular holes, keep cables centered against the core to avoid sampling errors caused by unilateral offset;
  8. Secondary output terminals shall be reliably connected to the EOCR current sampling ports. Never open the secondary circuit, as open-circuit will generate high voltage and damage components;
  9. When multiple transformers are connected in parallel for measurement, the total impedance of secondary circuit loads shall not exceed the rated burden limit of 1.25 バージニア州;
  10. Operating ambient temperature shall be maintained between -10℃ and +60℃, keep away from strong electromagnetic interference sources such as contactors and inverters;
  11. Tighten terminal screws after wiring, conduct regular inspections for cable insulation abrasion, overheating and discoloration.

Ⅶ. Troubleshooting Matrix

故障現象根本的な原因解決
EOCR frequently reports false overload alarmsOff-center cable threading, loose secondary wiringRe-thread cables in center position and fasten secondary terminals
No protection trigger upon motor locked rotor壊れた / open secondary circuitCut off power to check circuit continuity and repair wiring
Sampling reading deviation over 3%Long-term overload exceeding 300 A primary currentReplace transformer with higher ratio and control load current
Transformer housing overheatingContinuous overload, excessive secondary loadReduce quantity of secondary meters to match rated burden

VIII. Model Replacement Guidelines

  1. Same-rating replacement: 3CT-H3-300-Z only adopts square through holes, interchangeable for busbar applications; 3CT-H3-300-C is preferred for cable wiring;
  2. ブランド間の交換: Must match 300/5 A ratio, 1.25 VA burden and integrated 3-phase structure. Separate single-phase standalone transformers cannot be directly substituted, which will trigger abnormal phase-loss protection logic.
  3. 安全上の注意事項
  4. Primary rated current shall not exceed 300 A for long-term operation; sustained overload will permanently impair core measurement accuracy;
  5. No disconnectable components such as fuses or switches are allowed on the secondary side. Cut off power of the primary main circuit before any maintenance;
  6. Reserve heat dissipation gaps during cabinet mounting; do not install closely to heat-generating components including contactors and thermal relays;
  7. Only applicable to 50 Hz power frequency low-voltage power circuits; special inverter-type transformers are required for high-frequency variable-frequency circuits;
  8. Each product is delivered with an original factory calibration label. Verify the full model before spare part replacement; frames H1/H2/H3 cannot be mixed for use.