Basic Model Definition
ブランド: SIRAI (now owned by ASCO Emerson, original Italian manufacturer)
モデル: L323V01G
関数: 3/2 Direct-Acting Normally Closed (ノースカロライナ州) Mini Solenoid Valve Body (Coil Not Included; ZA/ZB Series Coils to Be Ordered Separately)
- 主要な技術仕様
Fluid Structure Parameters
| パラメータ項目 | 仕様 |
| 回路構成 | 3-Way 2-Position, 通常閉 (ノースカロライナ州) |
| Actuation Type | 直動式 (No pilot; reliable actuation at low pressure) |
| ポートネジ | G1/4 Female Thread (ISO228/1) |
| オリフィス径 | 1.5 mm |
| Flow Coefficient Kv | 0.08 m3/h |
| バルブボディ材質 | OT58 Brass |
| Standard Seal | NBR Nitrile Rubber (FKM Fluoroelastomer / EPDM Optional) |
| Max Medium Viscosity | 37 cSt (5°E) |
圧力範囲
Max Static Pressure Rating: 40 バー
Operating Pressure Differential for AC Coils: 0 ~ 16 バー
Operating Pressure Differential for DC Coils: 0 ~ 10 バー
温度範囲
中温: -10℃ ~ +90℃
周囲温度: -10℃~+50℃ (Max 60℃ for Class F Coils; Max 80℃ for Class H Coils)
電気的整合 (Coil Not Included with Valve Body)
Compatible Coil Models: ZA10A, ZB10A, ZA13A, ZB14A, 等.
Standard Voltages:
交流: 24V/50Hz, 110V, 220/230V 50Hz
直流: 12V, 24V
侵入保護: IP67 when fitted with standard DIN connector; 100% ED (Continuous energization without coil burnout)
- 3/2-Way Operating Principle
- 通電されていない (Normal Closed State): Inlet Port 1 is sealed; ポート 2 communicates with exhaust Port 3 for pressure relief.
- 元気が出る (Open State): Solenoid pulls plunger; flow path 1→2 opens, exhaust Port 3 is closed.
アプリケーション: Pneumatic direction switching, vacuum gripping, small air circuit shutoff, water spray control.
- Compatible Media & 産業用途
- Applicable Media: 圧縮空気, nitrogen, clean water, diluted coolant, non-corrosive inert gas.
NBR is incompatible with oil and high-temperature steam; select FKM seal version for corrosive media.
- 代表的な用途
Mini pneumatic directional valves for automation equipment
Water circuit control for small washers and humidifying spray systems
Small air circuit shutoff for packaging machines & 繊維機械
実験器具 & miniature vacuum circuit control
- モデルの選択 & Matching Guidelines
- Complete Order Model Format: L323V01G-ZA10A 230VAC (Valve Body + コイル + 定格電圧)
- Seal Upgrade: Custom valve bodies with FKM fluoroelastomer seals available for high-temperature / oil-water working conditions.
- 代替モデル: Same series L323V02G (Normally Open NO), L323V03G Universal Type
- Mounting Requirements: Mountable at any angle. Install a 40–100 mesh filter upstream of piping to prevent plunger jamming by contaminants. Only wrap the last two rear threads of male pipe threads with PTFE tape to avoid debris entering the valve chamber.
- 一般的なトラブルシューティング マトリックス
| 故障現象 | 根本的な原因 | 是正措置 |
| No switching when energized | 焼けたコイル, mismatched voltage, pressure differential exceeds 10 bar for DC | Replace matching coil; reduce pipeline pressure differential |
| Persistent leakage after shutdown | Contaminants on plunger, aged seals | Disassemble and clean plunger; replace NBR/FKM seal kit |
| Coil heats up rapidly | Incorrect voltage selection, long-term excessive pressure differential, damaged coil insulation | Verify nameplate voltage; adopt Class H high-temperature coil |
| Continuous air leakage from exhaust port | Worn plunger, seal scratched by particulate media | Install upstream filter; replace complete valve body assembly |
ASCO SIRAI L323V01G Solenoid Valve Instruction Manual
正式な製品名: SIRAI L323V01G 3/2 Direct-Acting Normally Closed Mini Solenoid Valve Body (Coil Not Included)
Brand Affiliation: SIRAI Italy, a fluid control brand under Emerson ASCO
適用規格: CE, UL, RoHS, DIN43650 electrical connector, ISO228/1 pipe thread
Table of Contents
- 製品概要 & モデルの解釈
- 主要な技術仕様
- Valve Body Structure & Fluid Circuit Principle
- 材料 & Seal Selection
- Matching Coil Models & 電気仕様
- 全体の寸法 & 取付方法
- Piping Installation Specifications
- Electrical Wiring Instructions
- Media Compatibility & アプリケーションシナリオ
- メンテナンス手順
- 故障診断 & 救済策
- Complete Order Model Rules
- Safety Prohibitions
- 製品概要 & モデルの解釈
1.1 Product Introduction
The L323V01G is a 3-Way 2-Position Normally Closed (ノースカロライナ州) direct-acting solenoid valve body. Pilot-free design enables reliable startup under low pressure. Compact size adapts to miniature pneumatic, water and vacuum control loops. Valve body and coils are supplied separately; ZA/ZB series coils must be ordered independently.
1.2 Model Breakdown – L323V01G
| セグメント | 意味 |
| L323 | L323 series miniature direct-acting solenoid valve platform |
| V | Brass valve body version (OT58 Brass) |
| 1 | 3/2 通常閉 (ノースカロライナ州) |
| G | G1/4 BSPP Female Thread (ISO228/1) |
Suffix Comparison for Same Series:
02 = 3/2 通常開 (いいえ)
03 = 3/2 ユニバーサルタイプ
Thread Suffix F = G1/8
- 主要な技術仕様
2.1 Fluid Performance
| パラメータ項目 | Standard Specification |
| Functional Type | 3-Way 2-Position, 通常閉 (ノースカロライナ州) |
| 接続口径 | G1/4 Female Thread |
| Seat Orifice Diameter | 1.5 mm |
| Flow Coefficient Kv | 0.08 m3/h |
| Max Medium Viscosity | 37 cSt (5°E) |
| Max Static Pressure Rating | 40 バー |
| Max Operating Differential Pressure (ACコイル) | 0 ~ 16 バー |
| Max Operating Differential Pressure (DCコイル) | 0 ~ 10 バー |
2.2 温度範囲
中温: -10℃ ~ +90℃ (NBR Seal); -10℃ ~ 120℃ (FKM Fluoroelastomer Seal)
周囲温度: -10℃ ~ +50℃ for standard Class F coils; max 80℃ for Class H high-temperature coils
2.3 保護 & 認証
IP67 dustproof and waterproof with standard DIN connector
CE EMC compliance, UL coil certification, RoHS lead-free environmental standard
Coils support 100% ED continuous energization without overheating burnout risk
- Valve Body Structure & Fluid Circuit Principle
3.1 Valve Port Number Definition (3-Way)
ポート 1 (P): Media Inlet (Air/Water Supply)
ポート 2 (あ): Actuator Outlet (Cylinders, Spray Nozzles, Vacuum Suction Cups)
ポート 3 (R): Exhaust / Drain Port
3.2 Operating States
- De-energized Normal State (NC Closed)
Spring resets the plunger to seal Port 1; ポート 2 connects to Port 3 for pressure relief at the actuator end.
- Coil Energized Open State
Solenoid magnetic force overcomes spring tension to pull the plunger; flow path 1→2 opens for media output, and Port 3 exhaust passage is sealed.
- 材料 & Seal Selection
4.1 Base Materials
Valve Body: OT58 Brass
Plunger & Moving Armature: ステンレス鋼
春: 304 ステンレス鋼
4.2 Seal Material Selection Table
| Seal Grade | 材料 | Applicable Media | Max Temperature |
| Standard Factory Fit | NBR Nitrile Rubber | 圧縮空気, clean water, diluted coolant | 90℃ |
| Optional Upgrade | FKM Fluoroelastomer | Engine oil, diesel, high-temperature water, weakly corrosive solvents | 120℃ |
| Special Custom | EPDM Ethylene Propylene Rubber | Hot water, ozone, weak acid water | 110℃ |
- Matching Coil Models & 電気仕様
Coils are not included with valve bodies. Complete valve assembly requires matching ZA/ZB series coils; standard models: ZA10A, ZB10A, ZA13A, ZB14A.
5.1 Standard Voltage List
AC Alternating Current: 24V 50Hz, 110V 50Hz, 230V 50Hz
DC Direct Current: 12ワシントンDCで, 24ワシントンDCで
5.2 Coil Electrical Characteristics
絶縁クラス: Optional Class F (155℃) / クラスH (180℃)
コネクタ: DIN43650 3-pin standard plug (2 power pins + earth pin)
消費電力: 約. 8AC用VA; 約. 6DCの場合はW
- 全体の寸法 & 取付方法
- 取り付け & 固定する: Two M3 through mounting holes at valve bottom; mountable at any orientation (水平, vertical, inverted without position restrictions).
- Key Overall Dimensions (mm):
Total valve length: 45.5, 幅: 28, 身長: 21; Thread depth: 9.9
- Coil Assembly: Vertically snap coil onto positioning posts on valve top; secure via rotary latch, no tools required for assembly/disassembly.
- Piping Installation Specifications
- Install upstream filter: 40–100 mesh precision screen to prevent seal scratching by particulate contaminants.
- Thread Sealing: Only wrap the last two rear threads of male pipe fittings with PTFE tape; forbid debris entering valve chamber.
- トルク制御: Tightening torque for G1/4 fittings: 8–10N·m to avoid thread slipping or brass body cracking.
- Media Flow Direction: Strictly follow marking 1(P)→2(あ) on valve body; reverse pressurization prohibited.
- Maintenance Clearance: Reserve minimum 30mm clearance on coil side for disassembly.
- Electrical Wiring Instructions
8.1 Pre-Wiring Safety Requirements
Perform wiring with power disconnected; confirm zero circuit voltage before plug insertion/removal.
Voltage fluctuation limited within ±10% of rated voltage.
8.2 端子の定義 (3-Pin DIN Connector)
ピン 1: パワーラインL / DC Positive (+)
ピン 2: Neutral Line N / DC Negative (-)
ピン 3: Protective Earth (Yellow-Green cable; reliable equipment grounding required)
8.3 AC vs DC Distinction
- AC Coils: 無極性; Pin1/Pin2 can connect live and neutral interchangeably.
- DC Coils: Pin1 connects positive, Pin2 connects negative. Reverse polarity will not damage coil but prevents valve switching.
8.4 Waterproof Treatment
Rubber sealing gasket built into plug; tighten lock nut fully after wiring to maintain IP67 rating. Select LED-indicator waterproof plugs for humid outdoor environments.
- Media Compatibility & アプリケーションシナリオ
9.1 Permitted Media
Dry compressed air, nitrogen, clean water, diluted cutting fluid, vacuum negative pressure circuits
9.2 Prohibited Media
Concentrated acid & アルカリ, strong organic solvents, high-viscosity oil, particle-laden wastewater, steam (custom high-temperature FKM version required for steam service)
9.3 Typical Industrial Applications
- Mini cylinder direction switching for automation equipment
- Adhesive spraying & water mist humidification control for packaging machinery
- Small air circuit shutoff for textile machines
- 実験器具 & miniature medical fluid circuits
- Vacuum gripping & water switch control for small cleaning equipment
- メンテナンス手順
10.1 Routine Monthly Inspection
- Check coils for abnormal overheating or abnormal noise
- Inspect pipe threads for media leakage
- Verify no continuous air/water dripping from exhaust port
10.2 Periodic Disassembly & クリーニング (毎 3000 Operating Hours)
- Shut off air/water supply, release residual pressure and cut power supply.
- Remove coil, disassemble plunger assembly at valve bottom.
- Rinse contaminants from plunger and valve seat with purified water and anhydrous alcohol.
- Inspect seals for aging or cracking; replace full seal kit if damaged.
- Reassemble in original sequence and perform air/water leakage test.
10.3 Spare Parts List
シールキット, complete plunger assembly, matching coils, DIN waterproof connectors
- 故障診断 & Remedy Matrix
| 故障現象 | 根本的な原因 | Standard Remedial Solution |
| Valve fails to switch on energization | 1. 焼けたコイル; 2. Mismatched voltage; 3. Differential pressure over 10 bar for DC | コイル抵抗を測定する, replace compatible coil; reduce pipeline differential pressure |
| Persistent leakage at Port 2 after power-off | Contaminant adhesion on plunger, scratched worn NBR seals | Disassemble and clean plunger; replace full seal set |
| Continuous air leakage at exhaust Port 3 | Damaged seat seal, sealing surface worn by particulate media | Install upstream filter; replace complete valve body assembly |
| Coil overheats rapidly | Excessive supply voltage, long-term over differential pressure, aged coil insulation | Match supply voltage to nameplate; replace Class H high-temperature coil |
| Threaded fitting leakage | Insufficient PTFE tape wrapping, insufficient fitting torque | Rewrap sealing tape and fasten to specified torque |
- Complete Order Model Rules
Standard Full Model Format:
L323V01G-ZA10A 24VDC
Breakdown: Valve Body Model + Coil Model + 定格電圧
例:
L323V01G-ZB10A 230VAC (Complete valve with 220V AC coil)
L323V01G-ZA13A 24VDC (Complete valve with 24V DC coil)
Seal Upgrade Marking for Orders: Append suffix -FKM, 例えば. L323V01G-FKM-ZA10A 24VDC
- Safety Operating Prohibitions
- Static pressure exceeding 40 bar strictly forbidden; overpressure will rupture brass valve body directly.
- DC circuit differential pressure cannot exceed 10 bar for long-term operation, otherwise full shutoff cannot be achieved.
- Operation without upstream filter prohibited; contaminants will permanently damage seals.
- Hot plug/unplug of coil connector forbidden; electric arcs may burn coil terminals.
- FKM seal version mandatory when medium temperature exceeds 90℃; NBR seals degrade rapidly and fail.
- Reverse media installation (inlet via Port2, outlet via Port1) prohibited; permanent internal leakage will occur.
- Do not cover coil surface with thermal insulation cotton or debris; sufficient heat dissipation space must be reserved.
コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池