Schneider XB2-BVM4LC LED Pilot Light - コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池

微信: +86-13184948252 ワッツアップ: 0086-13811255435 電子メール: kent@bestcontactor.com

について 接触 |

Schneider XB2-BVM4LC LED Pilot Light - コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池

電気/

Schneider XB2-BVM4LC LED Pilot Light

型式コードの説明 (XB2-BVM4LC) Model Segment Definition XB2 Harmony XB2 Series – 22mm Standard Pushbutton & Pilot Light Range B Integrated complete pilot light (head and base as one unit, no assembly required) V Pilot Light M LED light source, AC 220~230V 50/60Hz AC version 4 Light head color: Red LC Factory version complying with Chinese ...

  • 製品詳細

型式コードの説明 (XB2-BVM4LC)

モデルセグメント意味
XB2Harmony XB2 Series – 22mm Standard Pushbutton & Pilot Light Range
BIntegrated complete pilot light (head and base as one unit, no assembly required)
VPilot Light
MLED光源, AC 220~230V 50/60Hz AC version
4Light head color: 赤
LCFactory version complying with Chinese standards, plastic threaded mounting base

Supplementary color codes for the same series:

1 = White, 3 = Green, 4 = Red, 5 = Yellow, 6 = Blue

Suffixes for voltage differentiation:

M: AC220V

Q: AC380V

B: AC/DC24V

D: DC direct current

  1. 主要な技術仕様

2.1 Electrical Ratings

定格電圧: AC 220~230V, 50/60Hz

Allowable Voltage Fluctuation: 0.8~1.1×Us (176V~253V)

動作電流: 約. 20ミリアンペア

光源: High-brightness monochromatic LED, filament-free, 長寿命

過電圧カテゴリ: クラスI

2.2 Mechanical Mounting Dimensions

パネルカットアウト: Standard Φ22.5mm

取付方法: Secured via rotating plastic lock nut; compatible with control cabinet panels of 1~6mm thickness

Head Appearance: Round convex lens cover

2.3 保護 & 環境仕様

侵入保護: IP66 (front dustproof and waterproof); IK05 impact resistance

動作温度: -25℃~+55℃

保管温度: -40℃~+70℃

Applicable Altitude: ≤2000m, no power derating required

準拠基準: IEC60947-5-1, GB/T14048.5, CE, RoHS, 到着

2.4 Service Life Metrics

LED Electrical Service Life: ≥50,000 hours of continuous illumination

耐振動性: 15g (40~2000Hz)

  1. 構造 & 配線説明書

3.1 端子の定義

The base is equipped with only 2 wiring terminals X1 and X2, non-polarized for AC supply

X1: Live wire L

X2: Neutral wire N

AC circuits have no polarity; connecting the two terminals to any position of a 220V circuit will light up the red pilot light.

3.2 Mounting Procedures

  1. Drill a Φ22.5mm round hole on the control cabinet panel, insert the pilot light body from the front side of the panel;
  2. Fit the lock nut onto the rear side and tighten manually for fixation;
  3. Connect control wires to terminals X1 and X2 on the base, then fasten wire clamping screws;
  4. Switch on power to test steady illumination.
  5. アプリケーションシナリオ
  6. Standard application for red lights: Equipment fault alarm, emergency stop circuit indication, overload warning, shutdown alert;
  7. Compatible equipment: PLC control cabinets, エアコンプレッサー, 工作機械, 生産ライン, water pump & fan control boxes;
  8. 回路の種類: Mains AC 220V control circuit, no intermediate transformer required.
  9. Cross-Series Selection Reference Table
モデル定格電圧アプリケーションシナリオ
XB2-BVM1LCAC220V待機する, power-on indication
XB2-BVM3LCAC220VNormal equipment running status
XB2-BVM4LCAC220V故障, シャットダウン, アラーム
XB2-BVM5LC黄色AC220VReady state, pre-alert warning
XB2-BVM6LCAC220VManual/Auto mode differentiation

24V low-voltage alternative model: XB2-BVB4LC (赤, 24AC/DCV)

  1. トラブルシューティング マトリックス
故障現象根本的な原因解決
No illumination after power-on1. No 220V supply in circuit; 2. Loose wire terminals; 3. Burnt LED chipMeasure circuit voltage with multimeter; retighten wiring terminals; replace the complete pilot light assembly
Flickering light with unstable brightnessVoltage exceeds 0.8~1.1 times rated value, ワイヤーの接触不良Stabilize supply voltage; re-crimp connecting wires
Severe overheating of pilot lightLong-term overvoltage operation, circuit leakageVerify input voltage; inspect circuit insulation integrity
Internal short circuit caused by water ingress into panelLoose lock nut, oversized panel cutout damaging IP66 performanceTighten lock nut fully, seal gaps on panel cutout
  1. 安全動作仕様
  2. Strictly prohibit direct connection to 380V supply, which will burn out the LED instantly; select XB2-BVQ4LC for 380V circuits;
  3. 推奨電線: 0.75~1.5mm² solid copper wire;
  4. Install cabinet sealing gaskets for humid control cabinets and outdoor enclosures to maintain IP66 protection;
  5. Designed solely for status indication, unable to carry high-power loads; no contact output function;
  6. Do not strike or grind the lens cover; scratches will drastically reduce light transmittance and protection performance.
  7. Order & 梱包情報

Individually packed per unit; standard packaging: 5 pieces per small box, 100 カートンあたりの個数

スペアパーツ: No separate LED chip spares available; replace the complete pilot light assembly if damaged

Conclusion on Color Replacement for シュナイダー XB2-BVM4LC (XB2BVM4LC)

  1. Official Factory Conclusion: The lens cover and LED color cannot be replaced separately
  2. The XB2-BVM series adopts an integrated non-detachable sealed structure (lens cover, colored LED chip, 220V current-limiting circuit and base housing are integrally injection-molded).
  3. Schneider official FAQ clearly states: The internal LED module of integrated XB2 pilot lights cannot be disassembled separately, and colored lens covers or LED components are not sold as separate spare parts. Only illuminated pushbuttons with split bases support LED core replacement; this all-in-one light does not allow color component replacement.
  4. Illumination principle: The lens cover itself is transparent, with a built-in red LED chip (color is not generated via colored filter lenses). Even if the lens cover is forcibly unscrewed, the internal light source remains red and color modification is impossible.
  5. Two On-Site Color Modification Solutions

解決 1: Direct Full Unit Replacement (推奨, 準拠, Factory Standard)

Purchase complete units of target color with the same AC 220V voltage; no wiring modification required, compatible with standard panel cutouts:

白: XB2-BVM1LC

緑: XB2-BVM3LC

黄色: XB2-BVM5LC

青: XB2-BVM6LC

交換手順: Cut off power → Loosen rear lock nut on panel → Remove old red light → Install new colored pilot light → Tighten lock nut and restore wiring.

解決 2: Temporary Emergency Fix (Only for short-term maintenance, not recommended for long-term equipment operation)

  1. External colored film: Attach high-temperature resistant translucent colored film to lens surface. Drawbacks: Reduced light transmittance, accelerated aging due to heat, degraded IP protection rating;
  2. Translucent colored spray coating inside lens cover: Permanently destroys factory IP66 protection rating; water vapor ingress easily triggers short circuits and fails equipment acceptance standards.
  3. Distinction Between Two Easily Confused Products (To Avoid Wrong Selection)
  4. XB2-BVM Integrated Pilot Light (This Model): Non-replaceable color, integrated encapsulation, no separate LED core spares;
  5. XB4 Series Pilot Light / XB2 Split Illuminated Pushbutton: Modular design with separately replaceable LED heads for free color switching, suitable for cabinets requiring frequent color adjustments.
  6. 補足事項
  7. Mandatory voltage matching: The original XB2-BVM4LC is rated AC 220V; only models with suffix M (220V) are acceptable for replacement. Models with suffix B (24V) or Q (380V) cannot be used;
  8. Safety standards compliance: Red/Green/Yellow pilot lights on industrial equipment correspond to fault/Running/pre-alarm status. Unauthorized long-term color modification via film violates machine tool and power distribution safety standards and will fail acceptance inspection;
  9. スペアパーツの調達: No separate lens or LED spares; only complete pilot light assemblies can be ordered as replacements.

前へ:

返信を残す

伝言を残す