모델 440RB23020C의 코드 지정 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

모델 440RB23020C의 코드 지정 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

소식무역 뉴스

모델 440RB23020C의 코드 지정

(Standard Format: 440R-B23020/C)

핵심 설명

이것은 safety monitoring relay from the Allen-Bradley (로크웰 오토메이션) Guardmaster Minotaur MSR5T Series, Series C version. It is intended for low-risk safety applications in industrial automation systems, such as safety gate monitoring and emergency stop button control.

1 완전한 모델 분석

모델 세그먼트Standard Format설명
440아르 자형440아르 자형Product family identifier for Rockwell Automation Bulletin 440R safety relays, part of the Guardmaster safety product range
-비Subseries code, representing the MSR5T Series (Minotaur Safety Relay Type 5T monitoring safety relay)
2302023020Function and configuration code, 다음과 같이 자세히:
– 2: Supply type (universal 24V AC/DC power supply)
– 3: Number of safety outputs (3 normally open NO safety outputs)
– 0: Auxiliary output type (1 normally closed NC auxiliary output)
– 2: Input configuration (1 normally closed NC single‑channel input, for safety gate interlocks and E‑stop buttons)
– 0: Reset type (selectable automatic / manual reset via jumper)
기음/기음Series version code, indicating Series C, the latest production version with firmware updates and performance improvements

2 Detailed Explanation of Each Code

  1. 440R – Product Family Identifier

440: Standard prefix for Rockwell Automation safety products, dedicated to the Guardmaster safety relay line

아르 자형: Abbreviation for Relay, defining the product as a safety relay, distinguishing it from other 440-series devices such as safety switches (440G) and safety controllers (440기음)

  1. B – Subseries Code (MSR5T)

B Corresponds exclusively to the Minotaur MSR5T model, a monitoring safety relay with key features:

Single-or dual-channel input (this model uses 1NC single-channel input)

3 independent redundant normally open safety outputs to ensure reliable safety function

1 normally closed auxiliary output for status feedback signals

Supports output monitoring to detect faults in the safety output circuit

  1. 23020 – Detailed Function Configuration Code
Digit의미Value in This Model사양
1세인트 자리 (2)Supply type2Universal 24V AC/DC power supply, wide‑range design for various control systems
2네 번째 자리 (3)Number of safety outputs33 평상시 열려 있음 (아니요) safety outputs for direct control of contactors or actuators
3rd digit (0)Auxiliary output type01 평상시 닫혀 있음 (NC) auxiliary output for PLC status feedback or indicator control
4번째 자리 (2)Input configuration21 평상시 닫혀 있음 (NC) single‑channel input for low‑risk applications
5번째 자리 (0)Reset type0Selectable automatic / manual reset via jumper on terminals X1‑X2
  1. C – Series Version Code

C Indicates the product is Series C, the latest production version

Version differences:

Series A: Original version

시리즈 B: Improved version with partial functional optimizations

Series C: Latest version with firmware updates, performance enhancements, and compatibility improvements

All series versions are fully functionally compatible and can be directly interchanged

3 주요 기술 매개변수 (for 440R-B23020/C)

매개변수사양
제품 유형Minotaur MSR5T safety monitoring relay
안전등급범주 4, PLe (ISO 13849‑1), 실 3 (IEC 61508), Stop Category 0
Input Configuration1 평상시 닫혀 있음 (NC) single‑channel input, suitable for safety gate interlocks and emergency stop buttons
출력 구성3 평상시 열려 있음 (아니요) safety outputs + 1 평상시 닫혀 있음 (NC) auxiliary output
공급 전압24V AC/DC (universal power supply)
재설정 방법오토매틱 / manual reset (selectable via jumper)
설치DIN 레일 장착 (안에 60715 준수), 너비 22.5 mm
보호 등급IP20 (앞쪽)
작동 온도-25 °C ~ +60 ℃

4 Application Areas & 선택 지침

일반적인 응용 분야

Safety gate monitoring (low-risk applications)

Emergency stop button control

Safety circuit monitoring for small machinery

주요 선택 포인트

Confirm input type: ensure single-channel 1NC input meets safety device connection requirements

Check output quantity: verify 3 NO safety outputs + 1 NC auxiliary output satisfy control circuit demands

Verify supply compatibility: confirm 24V AC/DC universal power matches system voltage

Version selection: Series C is the latest version and recommended for priority use

 