Grundfos DDE 6-10 B-PP/E/C-X-31I001FG Diaphragm Dosing Pump
재료번호: 97720906|Grundfos SMART Digital DDE Economy Digital Diaphragm Dosing 펌프 (Stepper Motor Driven)
모델 코드 분석
DDE 6-10 B-PP/E/C-X-31I001FG
- DDE: 시리즈, economy digital dosing pump (기본 모델, differs from premium DDA/DDC)
- 6: Max flow rate 6 L/h
- 10: 최대 작동 압력 10 술집
- 비: Control version = Basic, manual adjustment + pulse signal input control
- PP: Pump head material = Polypropylene
- 이자형: Seal material = EPDM (ethylene propylene diene monomer, resistant to water, weak acids & weak alkalis)
- 기음: Ball material = Ceramic
- 엑스: Valve type = Standard double ball valve (non-spring-loaded)
- 31I001: 전압 / 지역 / connection code: 230V 50Hz, I = Australia & New Zealand specification, 4/6mm hose connection
- FG: Cable and certification configuration code
핵심 기술 데이터
Max flow: 6 L/h; Min flow: 6 mL/h
Turn-down ratio: 1:1000, logarithmic adjustment knob 0.1~100% continuous regulation
운전하다: Stepper motor, full-stroke operation, stable dosing even with aerated media
횡격막: Solid PTFE diaphragm
Repeat accuracy: 5% 이하
보호 등급: IP65 / 네마 4X
Max medium viscosity: 50 mPa·s
Built-in air vent valve for easy priming
제어 모드: Local manual, external pulse input (dividable)
인증: CE, CSA-US, NSF61, EAC, RCM
일반적인 응용 분야
수처리 (raw water, 폐수, 보일러 물, 순환 냉각수), RO & ultrafiltration, swimming pools, light chemical dosing, sodium hypochlorite, 산 & alkali dosing (subject to EPDM chemical compatibility)
메모: EPDM is not suitable for strong oxidants, concentrated chlorine or aromatic solvents. For high-chlorine applications, select V (FKM) 버전.
Equivalent Series Reference (선택을 위해 & 대사)
DDE 6-10 B-PP/V/C-X-31I001FG: PP pump head + FKM 씰 (sodium hypochlorite resistant)
DDE 6-10 B-PVC/E/C-X-31I001FG: PVC pump head + EPDM 씰
DDE 6-10 B-PV/T/C-X-31I001FG: PVDF pump head + PTFE seals (heavy corrosion)
옵션 액세서리 (설치 키트)
Foot valve, injection valve, PE discharge tubing, PVC suction tubing, vent tubing, compression fittings (4/6mm hose)
Spare Parts List for DDE 6-10 B-PP/E/C-X-31I001FG (97720906)
Pump configuration: PP pump head + EPDM 씰 + ceramic ball valves (SD-S-1-PP/E/C-2, S-series for 6~9L/h flow range)
Complete Repair Kit (가장 인기있는, Full Set)
97751105|Pump Head Repair Kit SD-S-1-PP/E/C-2
Contains:
- PTFE composite main diaphragm
- Suction valve assembly (ceramic ball + EPDM seat seal)
- Discharge valve assembly (ceramic ball + EPDM seat seal)
- Pump head O-rings and small sealing gaskets
- Fixing screws, shims and air vent components
Compatible with DDE 6-10 and equivalently configured DDA 6–9L/h, PP/E/C combination
알림: Grundfos S-series (≤15L/h) does not supply loose individual balls or diaphragms as standalone OEM part numbers. Factory supply prioritizes complete valve kits or diaphragm+valve kits; loose single parts on the market are mostly aftermarket.
Split Kits (Separate Procurement If Required)
- Valve Kit (흡입관 + discharge valves only, no diaphragm)
암호: SD-S-PP/E/C-2 valve assembly (8-digit material number to be retrieved via Grundfos channel using pump PN 97720906)
내용물: 2 sets of valve assemblies (Al₂O₃ ceramic ball + EPDM valve seals)
- Diaphragm Only Kit (PTFE diaphragm only, no valves)
암호: SD-S-1-PP diaphragm kit, also retrieved by pump serial/material number
Material Breakdown (Cross-check for replacements)
횡격막: PTFE faced diaphragm with support flange
Valve ball: Al₂O₃ alumina ceramic ball
Valve seat O-ring / main pump head O-ring: EPDM (E code)
Pump head body: 폴리프로필렌 (PP)
If upgraded to sodium hypochlorite resistant version (V=FKM), repair kit PN will change and cannot be interchanged.
Cross-reference for different material sets (stocking reference)
PP/V/C (FKM seal for chlorine): Different repair kit PN from 97751105
PVDF/T/C (PTFE seal for heavy corrosion): Separate SD-S-PVDF/T/C-2 valve kit
PVC/E/C: Dedicated repair kit PN for PVC pump head variant
Grundfos DDE 6-10 B-PP/E/C-X-31I001FG Troubleshooting Guide
Applicable to DDE economy digital diaphragm dosing pump, PP pump head + EPDM 씰 + ceramic ball valve configuration
예방법: Isolate power before service. Wear protection for corrosive chemicals; ensure ventilation for hypochlorite, acid and alkali media.
- 잘못: Pump runs, no suction / no chemical output
| 징후 | 가능한 원인 | 확인하다 & 치료 |
| Stepper motor runs normally, stroke action visible, no discharge | Air trapped inside pump head, insufficient priming | 1. Open manual air vent valve on pump head;2. Keep suction hose fully submerged to drain air from piping;3. Cycle pump at low flow to purge bubbles; close vent after air removed |
| Air leakage on suction side (가장 빈번한) | Inspect foot valve, hose ferrules, cracked tubing;Ageing / kinked PE tubing or loose fittings leak air;Submerge foot valve ≥10cm below liquid level; avoid suction pipe above tank liquid level | |
| Suction/discharge valve stuck, ball stuck or fouled | Dismantle valve assemblies, clean ceramic balls and EPDM seats;Dirt, scale or crystals prevent tight sealing;Inspect balls for chipping or cracking | |
| Foot valve clogged / foot valve check valve failed | Remove and clean foot valve strainer; replace foot valve if worn or jammed | |
| Diaphragm ruptured | Check vent port and pump housing for chemical leakage;Medium entering drive chamber means diaphragm failure; shut down and replace repair kit | |
| Excessive suction lift | DDE has limited self-priming capability; flood suction side preferred (tank above pump); vertical suction lift ≤2m | |
| Medium viscosity out of range | Viscosity >50 mPa·s exceeds pump specification, poor priming |
- 잘못: Inaccurate flow, low/high actual output, flow drift
| 징후 | 가능한 원인 | 확인하다 & 치료 |
| Metered flow deviates from setpoint, persistently low flow | Air ingress or poor valve sealing (same as above leakage issues) | Perform air purge and suction side leak test first; this is the #1 cause of flow inaccuracy |
| Valve ball / seat wear, crystal buildup, poor sealing | Dismantle and clean valve assemblies; EPDM ages and swells under continuous high chlorine exposure – replace repair kit | |
| Diaphragm fatigue, reduced swept volume | Diaphragm creep after long runtime; replace full repair kit | |
| Unstable outlet backpressure, backpressure too low | Install backpressure valve on dosing pump outlet; free flow siphoning occurs without backpressure valve, causing uncontrolled flow;This pump rated 10 술집; continuous low-pressure siphoning leads to over-dosing | |
| Pulse control mode: wrong pulse scaling or faulty signal source | Verify pulse ratio and scaling parameters for external pulse control;Switch to local manual mode to isolate pump fault vs controller signal fault | |
| Changing chemical temperature or crystallisation | Temperature changes alter density; crystals accelerate valve wear and gradual flow decay | |
| Calibration lost | Re-calibrate by timed volumetric collection and re-set calibration on pump panel |
- 잘못: 비정상적인 소음, 진동
| 징후 | 가능한 원인 | 확인하다 & 치료 | |
| Regular tapping / clicking sound with unstable discharge | Ball hammering seat (typical air-bound noise) | Purge air first; cavitation causes dry ball impact noise | |
| 깨진 / chipped ceramic ball | Disassemble valve set; replace valve kit if ceramic ball damaged | ||
| Hum from motor, 심한 진동, intermittent output | Piping resonance, loose hose supports | Add pipe clamps; avoid rigid hard pipe tension pulling pump inlet/outlet | |
| Pump installed off-level, pump head under stress | Mount pump horizontally; prevent hose tension pulling pump head | ||
| Stepper motor overload, diaphragm jammed | DDE has no manual crank; energise and observe stroke movement;Jammed crystals or debris on diaphragm increase load | ||
| Intermittent high-pitched whistling | Over-restriction / dead-head pressure or cavitation | Check for blocked outlet piping or clogged injection valve; clean injection check valve |
- Other Common Faults
- Display normal, no pumping action at all
Power supply fault / 저전압; check 230V supply and loose terminals
Keypad lock active; unlock panel
- Leakage at pump head
Aged pump head O-rings, uneven bolt torque; tighten pump head bolts diagonally and evenly
Ruptured diaphragm with chemical leaking into drive side → stop immediately, replace repair kit
- Continuous dripping from air vent
Worn vent valve seal; replace vent valve component or full repair kit
Recommended Diagnostic Sequence
- Confirm power supply and control mode (현지의 / 맥박)
- Vent air → inspect suction side for air leaks
- Volumetric flow test to confirm true pump fault or signal issue
- Dismantle and inspect valve assemblies, ceramic balls and EPDM seals
- Inspect diaphragm for rupture and leakage
- Check outlet backpressure valve and injection valve for blockage or failure
- Final action: replace complete pump head repair kit (97751105)
안전 & 유지보수 노트
For crystallising media (PAC, phosphate, high brine), flush pump head and valves with clean water after shutdown to prevent seizure
EPDM seals are not suitable for long-term high-concentration sodium hypochlorite service; use V variant (FKM) for chlorine dosing
Tighten pump head bolts diagonally and evenly; uneven torque can crack PP pump head
Grundfos SMART Digital DDE Series List (S-series ≤15L/h Economy Range)
Important separation: S-series small flow DDE (6-10 /15-4) (the model above); separate XL large flow DDE (60/120/200 L/h). Spare parts are NOT interchangeable.
Control variants exclusive to DDE: 비 / 피 / PR
비: Basic|manual adjustment + pulse input (당신의 유닛: DDE 6-10 비)
피: 비 + external start/stop + low-level input
PR: 피 + 릴레이 경보 출력 (stroke signal, 오류 릴레이)
- S-series DDE (low flow 0–15 L/h, 널리 사용되는) 기본 모델
| 기본 모델 | Max Flow | Max Pressure | Turn-down Ratio | Min Flow |
| DDE 6-10 | 6 L/h | 10 술집 | 1000:01:00 | 0.006 L/h (6 mL/h) |
| DDE 15-4 | 15 L/h | 4 술집 | 1000:01:00 | 0.015 L/h (15 mL/h) |
전체 모델 형식:
DDE Flow-Pressure Control Code-Pumphead/Seal/Ball-Valve Type-Voltage Region Code FG
예: `DDE 6-10 B-PP/E/C-X-31I001FG`
Material Combinations (Pumphead / 밀봉하다 / Ball)
PP/E/C: PP pump head + EPDM 씰 + ceramic ball (your configuration, fresh water, weak acid/alkali)
PP/V/C: PP pump head + FKM 씰 + ceramic ball (sodium hypochlorite, chlorine media)
PVC/E/C: PVC pump head + EPDM 씰 + ceramic ball
PVC/V/C: PVC pump head + FKM 씰 + ceramic ball
PVDF/T/C: PVDF pump head + PTFE seal + ceramic ball (strong acid / heavy corrosion)
PP/E/SS: PP + EPDM + stainless steel ball (special abrasion service)
Valve Type Codes
엑스: Standard double ball valve (non-spring-loaded, 범용)
시간: Spring-loaded valve (unstable backpressure, high viscosity media)
전압 / Region Codes (흔한)
31I001: 230V 50Hz, RCM AU/NZ, 4/6mm hose compression (당신의 유닛)
31U2U2: 100–240V universal voltage, CE, EU specification
31다섯: 110V North America version
S-series Finished Model Examples (Direct for PO)
- DDE 6-10 B-PP/E/C-X-31I001FG (PN 97720906|your pump)
- DDE 6-10 B-PP/V/C-X-31I001FG (chlorine resistant same rating)
- DDE 6-10 PR-PP/V/C-X-31U2U2FG|alarm relay, 범용 전압
- DDE 15-4 B-PP/E/C-X-31I001FG|15L/h 4bar, EPDM
- DDE 15-4 P-PVDF/T/C-X-31U2U2FG|PVDF heavy corrosion, 펄스 제어
- SMART Digital XL DDE (Large Flow 60~200 L/h, 독립 범위)
XL pump head structure and repair kits are incompatible with S-series 6-10 /15-4
| DDE 60-10 | 60 L/h | 10 술집 |
| DDE 120-7 | 120 L/h | 7 술집 |
| DDE 200-4 | 200 L/h | 4 술집 |
XL example:
DDE 60-10 B-PP/V/C-F-31U3U3FG
- DDE Control Variant Function Table
| Control Code | Manual Adjustment | Pulse Input | External Stop / 낮은 수준 | Relay Alarm Output |
| 비 | ✅ | ✅ | ❌ | ❌ |
| 피 | ✅ | ✅ | ✅ | ❌ |
| PR | ✅ | ✅ | ✅ | ✅ (2 릴레이) |
- 시리즈 차별화 (Avoid mixing with DDC / DDA)
DDE: 경제, basic function, no 4-20mA analog input, 비용 효율적 (OEM water treatment standard)
DDC: Standard grade, 4-20mA 아날로그, extended menu, additional alarms
DDA: Premium grade, built-in FCM flow monitoring, 높은 정확도, batch dosing, complex interlock
- Spare Part Cross-reference Summary
S-series (6-10 /15-4): Repair kit family SD-S-1-xxx, PN 97751105 for PP/E/C
XL series (60/120/200): Dedicated XL repair kits, 교환불가
- 빠른 선택 안내
- Sodium hypochlorite / chlorine dioxide dosing: prefer `/V/` (FKM), avoid EPDM `/E/`
- 농축산 / heavy corrosion: PVDF `/T/`
- Unstable backpressure or siphon risk: select H spring-loaded valve instead of X standard valve
- Standard domestic global supply: prefer 31U2U2 universal voltage; AU/NZ export use 31I001