OMRON CP1W-8ER 순수 출력 확장 모듈 - 접촉기,회로 차단기,감지기,인코더,PLC,변환기

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

OMRON CP1W-8ER 순수 출력 확장 모듈 - 접촉기,회로 차단기,감지기,인코더,PLC,변환기

PLC/

OMRON CP1W-8ER 순수 출력 확장 모듈

CP1W: Expansion unit for CP1 series 8: 8 points E: Expansion R: Relay normally open (아니요) output Type: Pure output expansion module, no input points Core Specifications Number of output points: 8-point relay NO output Rated current per channel: 2 에이 (저항 부하) Output voltage range: AC/DC 4.5~30 V (passive relay contact) On/off delay: 대략. ...

  • 제품 세부정보

CP1W: Expansion unit for CP1 series

8: 8 전철기

이자형: 확장

아르 자형: Relay normally open (아니요) 산출

유형: Pure output expansion module, no input points

핵심사양

Number of output points: 8-point relay NO output

채널당 정격 전류: 2 에이 (저항 부하)

Output voltage range: AC/DC 4.5~30 V (passive relay contact)

On/off delay: 대략. 15 ms

소비전력: 5 DC에서 0.21 에이; 24 DC에서 0.13 에이

치수: W66 × H90 × D50 mm

무게: 대략. 250 g

인증: CE, UL, CSA

수명주기 상태: 활동적인, 중단되지 않음

호환 가능 CPU 단위

CP1E / CP1H / CP1L (CP1 series PLC); also compatible with legacy CPM1A/CPM2A

메모: 20-point CP1E CPU does not support expansion. Only 30/40/60-point CPUs can connect CP1W expansion units.

Cross-model Comparison (for selection)

CP1W-8ER: 8-포인트 릴레이 출력 (수동적인, AC/DC 범용)

CP1W-8ET: 8-포인트 NPN 트랜지스터 출력 (DC24V 전용)

CP1W-8ED: 8-포인트 DC24V 입력 모듈

CP1W-16ER: 16-포인트 릴레이 출력

배선 지침

  1. Two independent common terminals: COM0 (00~03), COM1 (04~07)
  2. Relay is dry contact: connect AC L / DC+ to COM as required, then wire the load to the contact terminal
  3. Do not drive high-power motors directly; add intermediate contactors
  4. 유도 부하용 (솔레노이드 밸브, 코일), install freewheeling diodes (DC) 또는 RC 스너버 (교류) to extend relay life.

문제 해결

출력 동작 없음:

1) Check if the expansion cable is firmly plugged in and the CPU recognizes the expansion unit

2) Verify the I/O address assignment (expansion I/O follows the previous unit’s address sequentially)

3) Measure COM power supply and check for open circuits in the load loop

Permanent ON for one channel: relay contact welding; replace the point or the whole module

No output on all channels: expansion function disabled, too many expansion units, or damaged cable.

교체 옵션

  1. 직접 교체: CP1W-8ER (우선의, no program modification needed)
  2. Transistor alternative: CP1W-8ET (for high-frequency switching and DC loads; cannot handle AC)
  3. 국내 대안: CP1-bus compatible 8-point relay expansion module (verify bus protocol and address mapping)

Service Life of CP1W-8ER (Limited by relay contacts)

Official rated life per relay channel

  1. 기계적 수명 (무부하 작동): ≥20 million operations
  2. 전기적 수명 (2 저항 부하): ≥100,000 작업

요점: Electrical life is the bottleneck, not the PCB. 유도 부하 (솔레노이드 밸브, 접촉기 코일) drastically shorten service life down to 20,000~50,000 cycles. Snubber circuits will improve this.

Time Estimation (for project evaluation)

1 operation per minute: 100,000 cycles ≈ 19 연령

1 operation per 10 초: 100,000 cycles ≈ 2.8 연령

1 operation per second: 100,000 cycles ≈ 27 시간

For equipment with continuous ON state and rare switching: contact wear is minimal. In clean, temperature-controlled cabinets, the PCB, cable and terminals can run stably for 8~15 years. Service life is halved in high-temperature, 습하고 먼지가 많은 환경.

Two Types of Service Life

Contact life: limited by switching cycles; failure symptoms: contact welding or poor contact

Module body life: PCB, cable and drive circuit; aging depends on environmental conditions, no fixed cycle rating.

Life Extension Tips

  1. Add freewheeling diodes (DC) 또는 RC 스너버 (교류) for inductive loads such as solenoid valves and contactors.
  2. Keep load current below 1 에이; avoid continuous full-load (2 에이) 작업.
  3. For high-frequency switching (cycles within seconds), use CP1W-8ET transistor output instead of ER relay modules.
  4. Regularly inspect expansion cables and terminals for oxidation and loose connections.

Full List of 오므론 CP1W Expansion Units (CP1E / CP1H / CP1L Compatible)

메모: CP1W units are bus-connected expansion modules (daisy-chained with flat cable). CIF, ADB and DAB boards are CPU side option boards (not bus expansion units). 20-point CP1E cannot use expansion units; only 30/40/60-point CP1E, CP1H and CP1L-M support CP1W expansion.

  1. Digital Input Only Units
모델설명
CP1W-8ED8-포인트 DC24V 입력 (NPN/PNP universal)
  1. Digital Output Only Units (CP1W-8ER listed here)
모델설명
CP1W-8ER8-point relay NO output, 2 에이
CP1W-8ET8-point NPN (sinking) 트랜지스터 출력, 0.3 에이
CP1W-8ET18-point PNP (소싱) 트랜지스터 출력, 0.3 에이
CP1W-16ER16-point relay NO output, 2 에이
CP1W-16ET16-포인트 NPN 트랜지스터 출력, 0.3 에이
CP1W-16ET116-point PNP transistor output, 0.3 에이
CP1W-32ER32-point relay NO output, 2 에이
CP1W-32ET32-포인트 NPN 트랜지스터 출력, 0.3 에이
CP1W-32ET132-point PNP transistor output, 0.3 에이
  1. 혼합 I/O 장치 (입력 + Output integrated)
모델설명
CP1W-20EDR112 DC inputs + 8 릴레이 출력
CP1W-20EDT12 DC inputs + 8 NPN transistor outputs
CP1W-20EDT112 DC inputs + 8 PNP transistor outputs
CP1W-40EDR24 DC inputs + 16 릴레이 출력
CP1W-40EDT24 DC inputs + 16 NPN transistor outputs
CP1W-40EDT124 DC inputs + 16 PNP transistor outputs
  1. Analog I/O Units (전압 / 현재 신호)
모델설명
CP1W-AD0414 일체 포함, 해결 1/6000; 전압/전류 선택 가능
CP1W-AD0424 일체 포함, 고해상도 1/12000
CP1W-DA0212 에, 해결 1/6000
CP1W-DA0414 에, 해결 1/6000
CP1W-DA0424 에, 고해상도 1/12000
CP1W-MAD112 일체 포함 + 1 에, 해결 1/6000
CP1W-MAD424 일체 포함 + 2 에, 고해상도 1/12000 (가장 인기있는)
  1. Temperature Input Units (열전대 / Pt RTD)
모델설명
CP1W-TS0012-채널 열전대 (K/J type)
CP1W-TS0022-channel Pt100/Pt1000 RTD
CP1W-TS0032-channel multi-function: 열전대 / RTD / 아날로그 입력
CP1W-TS00412-채널 열전대 (for oven & injection molding multi-point temperature monitoring)
  1. 부속품 (Expansion Cable)
모델설명
CP1W-CN81180 cm extension cable; short cable (6 cm) included with each module

보충: CPU Side Option Boards (NOT Bus Expansion Units)

These plug directly into the CPU side slot and cannot be daisy-chained on the I/O bus:

CP1W-CIF01: RS232C

CP1W-CIF11: Non-isolated RS422/485

CP1W-CIF12 / CIF12-V1: Opto-isolated RS422/485

CP1W-CIF41: Ethernet option board

CP1W-DAM01: LCD display panel

CP1W-ADB21 / DAB21V / MAB221: Small analog option boards

빠른 선택 가이드

  1. 고주파 스위칭, 솔레노이드 밸브, servo pulse output → Choose ET / ET1 transistor models, do not use ER relay modules
  2. AC220V loads with infrequent switching → Select ER relay models
  3. 열전대 온도 측정: TS001; Pt RTD: TS002; multi-point temperature monitoring: TS004
  4. 아날로그 I/O: MAD42 (4-인 2아웃) 선호된다; new projects select high-resolution AD042 / DA042

 

이전:

다음:

답장을 남겨주세요

메시지를 남겨주세요