PNOZ I B0 772138
상표: 버섯 (버섯, 독일)
제품 시리즈: PNOZmulti Modular Safety Relay / Programmable Safety Controller
✅ Model Description
PNOZ m: PNOZmulti modular safety system
B0: 기본 단위 (main controller body, no expansion modules included)
772138: Material number
📋 Key Specifications
- 안전등급: PL 전자 / 실 3 (ISO에서 13849-1 / IEC 61508)
- 전원공급장치: DC 24V
- 입력: 14 digital safety inputs
- 출력: 4 semiconductor safety outputs (OSSD)
- 의사소통: The base unit has an integrated Ethernet port. Programming is supported via the PNOZmulti Configurator software; expansion modules can be connected.
- 기능: Graphical configuration of safety logic for E-stop, 안전문, 안전 라이트 커튼, two-hand buttons, safety limit switches, 등.
- 울로 둘러싼 땅: DIN 레일 장착, IP20, 캐비닛 설치
- 소프트웨어: PNOZmulti Configurator (free configuration software, graphical drag-and-drop, no programming language required)
🧩 Product Positioning
The PNOZ m B0 (772138) is a compact modular safety PLC within the PNOZmulti family. It operates independently. When I/O capacity is insufficient, PNOZmulti expansion modules (예를 들어. 772140, 772142) can be added to expand safety inputs and relay outputs.
🛠️ 일반적인 적용 시나리오
공작기계, 포장 기계, 자동화된 생산 라인
Robot safety protection, safety gate interlocking
Emergency stop circuits, safety light curtain monitoring
Presses, conveyor safety control
⚠️ Critical Model Distinction (일반적인 혼란)
772138: PNOZ I B0 (semiconductor OSSD outputs, 4 OSSD channels)
772140: PNOZ m B1 (version with relay outputs)
📌 Configuration & 진단
PC Connection: Use USB/Ethernet to connect to a PC for program download and online diagnostics via PNOZmulti Configurator
Local Indication: Front-panel LEDs for fast diagnosis of input, output and fault status
🔍 Spare Parts & 교체 정보
Original direct replacement: Same part number 772138. Check the latest PILZ product obsolescence notice for end-of-life status.
Domestic equivalent reference: 혁신, Xinje safety PLC, Schneider XPSM series. These are solution-level alternatives only, not direct hardware drop-in replacements. Safety logic must be reconfigured.
📎 Common Troubleshooting Checklist
- No LEDs after power-up: Check DC24V supply and polarity
- Flashing fault LED: Configuration validation error, wiring short-circuit, OSSD overload
- Safety circuit cannot be enabled: Check wiring of safety input channels, contact status of E-stop / safety gate, software configuration logic
- 통신 실패: Inspect network cable, IP address, software version compatibility
PNOZmulti Configurator Getting Started Example (PNOZ I B0 /772138)
Project Goal: Dual-channel E-stop + dual-channel safety gate, shared external reset button, meeting PL e / SIL3. Uses only onboard I/O of the base unit, no expansion modules.
소프트웨어: PNOZmulti Configurator (free download from official website, graphical drag-and-drop configuration, no coding)
- Hardware Point Assignment (PNOZ m B0 Terminal Block)
| 신호 | Hardware Channel | 설명 |
| Dual-channel E-stop (평상시 닫혀 있음) | I0 / I1, test pulses T0 / T1 | 유형 3 듀얼 채널, cross-contact short-circuit detection |
| Dual-channel safety gate (PSEN mechanical safety gate, 평상시 닫혀 있음) | I2 / I3, test pulses T2 / T3 | 유형 3 듀얼 채널, cross-contact short-circuit detection |
| Manual reset button (평상시 열려 있음) | I4 | Reset signal, single-channel input |
| Safety semiconductor OSSD output | O0, O1 (paired OSSD) | Safety enable output, drives servo / contactor safety circuit |
배선 참고 사항: E-stop and safety gate must use two independent normally closed contacts. The reset button is normally open. Manual reset is mandatory (per safety standards: manual confirmation required after fault clearance; automatic restart on power-up is prohibited).
- New Project Setup in Software
- Open Configurator → New project, hardware selection PNOZ m B0 (772138)
- Enter [하드웨어 구성]: No expansion modules for this project, confirm directly
- Enter [User Program] (graphical canvas, drag-and-drop function blocks)
III. 추가하다 & Configure Function Blocks
1) Add E-STOP Function Block
Drag E-STOP from the library onto the canvas
Input tab:
스위치 유형: Type3 (Dual-channel NC)
✅ Check Detect short-circuit between contacts (mandatory for dual-channel fault diagnosis)
Channel1: I0, test pulse T0; Channel2: I1, test pulse T1
Reset tab: 수동 재설정, reset input I4
이름: E-STOP_Machine_EmergencyStop
2) Add Safety Gate Function Block
Drag the Safety Gate function block
Input tab:
유형: Type3 dual-channel normally closed
✅ Check detect short-circuit between contacts
Channel1: I2, T2; Channel2: I3, T3
Reset tab: 수동 재설정, reset input I4 (shared reset button with E-stop)
이름: `SAFETY_GATE_ProtectionGate`
3) Add AND Logic Block
Logic rule: E-stop OK AND Safety gate closed → Safety output enable
Drag AND logic block
Two AND inputs: connect to OK output of E-STOP block and OK output of Safety Gate block respectively
AND output → connect to [Semiconductor Safety Output OSSD] function block
4) Add Semiconductor Safety Output OSSD
Drag OSSD output block, assign hardware O0, O1 (paired safety output)
입력: Output signal from AND block
Output feedback: Contactor feedback monitoring not implemented in this example; can be added later if required
Simplified logic description: E-stop released AND safety gate closed → press reset, OSSD safety output ON. If any safety condition is violated, OSSD cuts off immediately.
- 확인, 다운로드 & Online Diagnostics
- Click [Project Validation] to check CRC, parameters and hardware matching, resolve all errors
- Two download options:
Option A: Micro USB cable directly connected to PNOZ m B0 for online program download
Option B: Download to memory chip card, insert card into controller; program loads automatically on power-up
- Online diagnostic: Real-time monitoring of I0~I4 input status, OSSD output status and fault codes
- After download, set hardware to Run mode and perform field testing
- Field Test Logic (확인)
- Normal condition: E-stop released, safety gate closed → press reset → OSSD output ON (safety enable)
- E-stop pressed: E-STOP block trips → AND output de-energized → OSSD OFF immediately
- Safety gate opened: Safety gate block trips → AND output de-energized → OSSD OFF immediately
- Fault recovery: After E-stop released / gate closed, reset button must be pressed again to re-enable safety output
- Common Configuration Pitfalls (High Priority)
- Type3 dual-channel: Two contacts must be independent, do not short internally, otherwise short-circuit detection triggers faults
- Test pulse T must correspond one-to-one with input I; channels cannot share test pulses
- Reset configuration: Machinery safety standards forbid automatic reset. Safety output cannot auto-restart after gate opening or E-stop activation
- OSSD is semiconductor output with short-circuit monitoring; short circuit on downstream load triggers safety fault
- Safety rating: This configuration achieves PL e / SIL3 only with correct wiring. Incorrect wiring downgrades safety level.
Ⅶ. Expansion Options (Modify within the same project later)
Add safety light curtain function block
Add contactor feedback monitoring (external feedback circuit)
Add OFF-Delay for inertial stopping
Add Modbus TCP/Profinet communication to transmit safety status to PLC
PILZ PNOZmulti 2 전체 모델 목록 (PNOZ m Series including 772138)
설명: PNOZmulti 2 is the second-generation modular safety controller. Divided into Base Unit, I/O Expansion Modules EF, Fieldbus Communication Modules ES, Motion Monitoring Modules and Accessories. Your referenced 772138 = PNOZ m ES Profinet (Profinet communication module)
- 기본 단위 (Main Controller)
| 부품 번호. | Model Name | 주요 설명 |
| 772100 | PNOZ I B0 | General base unit, 최대 6 safety expansion modules; 20 safety inputs, 4 OSSD semiconductor outputs, USB + memory chip card |
| 772104 | PNOZ m B0.1 | Economy B0 version, 최대 1 I/O expansion module only; 20 safety inputs, 4 OSSD |
| 772101 | PNOZ m B1 | Large-scale project main unit, integrated Modbus TCP, 듀얼 이더넷 포트; 최대 12 safety expansion modules |
| 772102 | PNOZ m B1 Burner | B1 burner dedicated version with built-in burner safety function blocks |
| 772105 | PNOZ m C0 | Compact non-expandable standalone unit; 8 safety inputs, 4 OSSD, 확장 기능 없음, for small standalone machines |
- I/O Expansion Modules (PNOZ m EF series, right-side expansion)
| 부품 번호. | Model Name | 사양 |
| 772140 | PNOZ m EF 16DI | 16-channel safety digital input |
| 772142 | PNOZ m EF 8DI4DO | 8 safety DI + 4 safety semiconductor OSSD outputs |
| 772143 | PNOZ m EF 4DI4DOR | 4 safety DI + 4 safety relay outputs (relay contacts) |
| 772144 | PNOZ m EF 8DI2DOT | 8 safety DI + 2 bipolar semiconductor safety outputs (press machine dedicated) |
| 772145 | PNOZ m EF 2DOR | 2-channel safety relay output module (new compact relay module) |
| 772160 | PNOZ m EF 4AI | 4-channel safety analog input (0-10다섯 / 4-20엄마) |
| 772170 | PNOZ m EF 1MM | Single-axis safety motion monitoring (속도, standstill, direction) |
| 772171 | PNOZ m EF 2MM | Dual-axis safety motion monitoring |
| 772120 | PNOZ m EF Multi Link | Safety interconnection between two PNOZmulti2 controllers |
| 772122 | PNOZ m EF SafetyNET | SafetyNET p real-time safety Ethernet interconnection module |
III. Fieldbus Communication Modules (PNOZ m ES, plug into left side of base unit, 포함 772138)
Bus modules communicate with upper PLC to read safety status and transmit control signals
| 772138 | PNOZ m ES Profinet | Profinet Industrial Ethernet (타겟 모델) |
| 772134 | PNOZ m ES EtherCAT | EtherCAT (FSoE safety protocol) |
| 772135 | PNOZ m ES EtherNet/IP | 이더넷/IP |
| 772136 | PNOZ m ES Profibus | 프로피버스 DP |
| 772137 | PNOZ m ES CANopen | CANopen |
| 772131 | PNOZ m ES CC-Link | CC-링크 |
| 772130 | PNOZ m ES Powerlink | Ethernet POWERLINK |
| 772123 | PNOZ m ES ETH | General Ethernet module (모드버스 TCP) |
- Remote Distributed I/O (PDP67, IP67 field-side modules, requires PDP-Link)
| 부품 번호. | Model Name | 사양 |
| 772600 | PDP67 F 8DI4DO | 8에서 + 4~하다, IP67 보호 등급 |
| 772610 | PDP67 F 10DI4DO | 10에서 + 4~하다 |
| 772121 | PNOZ m EF PDP Link | Controller-side coupler for PDP67 |
- Common Accessories List
| 부품 번호. | 액세서리 이름 |
| 779261 | End cap (termination cover for module bus end) |
| 312992 | Mini USB download cable, 3중 |
| 750008 | Screw terminal kit |
| 751008 | Spring-cage terminal kit |
Supplementary Key Notes
- Installation Position Differentiation
EF I/O modules: cascaded on the right side
ES bus communication modules: inserted on the left side of base unit, 최대 1 bus module per controller
- 호환성: B0/B0.1/B1/C0 all support ES bus modules. B0.1 supports only 1 EF I/O module; B0 max 6 EF modules, B1 max 12 EF modules
- 안전 수준: Proper configuration and wiring of the full system achieves maximum PL e / SIL3
- 소프트웨어: All devices use PNOZmulti Configurator for unified configuration
Legacy PNOZmulti Classic (1st Generation, separate from PNOZmulti2)
Old generation mm0p/mm1p/mm2p/mm3p, part number series 7720xx. Hardware is incompatible with 2nd-gen B0/B1. Project migration requires full reconfiguration; hardware cannot be hot-swapped as direct replacement.
PNOZmulti 2 (PILZ 2nd-Gen Modular Safety Controller) 응용 시나리오
PNOZmulti2 core positioning: Programmable modular safety system up to PL e / SIL3. Used for stand-alone / multi-axis machine safety monitoring, replacing discrete safety relays. Supports safety logic configuration, fieldbus communication and safety motion monitoring. Applications grouped by industry and safety tasks as below.
- 공작기계 산업 (가장 일반적인 응용 프로그램)
- Metal-cutting machine tools (머시닝 센터, 선반, 그라인더, 밀링 머신)
Guard door interlock, safety light curtain / laser scanner monitoring
Dual-channel E-stop, two-hand operation buttons
Axis safety monitoring: SSM 안전 속도 모니터링, SS1 Safe Stop 1, SLS Safely Limited Speed (paired with MM motion modules)
Safe stop for spindle / feed axes; axis lockout when guard door is open
Local safety diagnostics, safety status and fault codes uploaded via Profinet/EtherCAT to main PLC (772138 PNOZ m ES Profinet widely used)
- 누르다 / 굽힘 / shearing machines
안전 라이트 커튼 + two-hand button combination
Press cam monitoring, slide position monitoring
Anti-restart function, delayed safe stop for inertial hazard mitigation
선택 팁: PNOZ m EF 8DI2DOT bipolar semiconductor output module is frequently selected.
- 포장 & Conveyor Automation
- 포장 기계: Vertical form fill seal, pillow packaging, case packers, 팔레타이저, stretch wrappers
Machine guard doors, 안전 라이트 커튼, E-stop circuits
Safety zone monitoring for conveyor lines, area laser scanners
Conveyor safe stop, material jam safety interlock
- Complete production lines, 정렬 & 운반 시스템
Multi-zone safety interlock: Opening door A stops only the corresponding zone instead of the whole line (zone safety is a major advantage of PNOZmulti2)
Distributed field I/O PDP67 for local sensor connection (IP67)
Safety status transmitted via fieldbus to main PLC / HMI for fault alarming
III. Robot Workcells (Industrial Robot Safety)
Robot perimeter guard doors, safety laser scanners
Safety zone switching: Automatic operation zone / reduced safe speed SLS for manual intervention
Dual-channel E-stop, safety reset logic
Combined safety interlock for robot + peripheral tooling (tool guard doors, clamp confirmation)
Safety signal exchange with robot controller; Profinet/EtherCAT transmits safety diagnostic data
- 고무 & 플라스틱, Extrusion & Injection Molding Equipment
사출 성형기: Mold safety doors, injection unit guards, 안전 라이트 커튼
압출기, pelletizing lines: Barrel and die head guard interlocks
롤러, calender safety protection against entrapment hazards
Delayed safe stop for inertial rotating rollers
- 자재 취급 & Warehouse Automation
- 스태커 크레인, 자동화 창고, RGV/AGV workstations
Maintenance access doors, guardrail safety doors, 비상 정지
Travel axis safe speed limiting, safe standstill monitoring
Zone locking during maintenance for partial isolation
- 리프트, 엘리베이터, hoist auxiliary equipment (only surrounding safety control, not the hoisting mechanism itself)
Guard doors, safety limit monitoring to prevent personnel entering lifting zones
- 음식 & 제약 장비
충전물 기계, capping machines, 라벨러, cleaning equipment
Hygienic safety doors and safety sensors
Compliance with EN ISO13849 machinery safety standard; IP20 controller in electrical cabinet paired with IP67 PDP67 remote I/O for sensors installed on-machine for washdown environments.
Ⅶ. Tire, 종이 & Textile Large Production Lines
Large roller equipment, 와인더, paper rewinding machines
Multi-axis coordinated safety monitoring (Dual-axis motion module EF 2MM)
Multiple E-stop buttons along long production lines, segmented safety isolation
Centralized management for many safety doors and light curtains on large machines
Ⅷ. 특수산업
- Combustion / heat-treatment equipment: PNOZ m B1 Burner dedicated base unit with built-in burner safety function blocks
- 테스트 벤치 / trial equipment: Durability test rigs, impact test stands. Safety logic can be modified flexibly for product changeover without hardware replacement.
✅ Application Selection Guide (When to choose PNOZmulti2)
Recommended when:
Safety logic is not simple series connection of E-stop + safety gate, requiring AND/OR logic, 타이머, zone safety, conditional interlocks
High quantity of safety I/O, many safety gates, light curtains and E-stops to be centrally managed
Safety motion monitoring required (SLS/SSM/SS1 etc.)
Fieldbus communication needed (프로피네트, EtherCAT) to upload safety diagnostics to standard PLC (772138 Profinet module widely adopted)
Frequent product changeovers requiring safety logic modification without hardware swap
Inter-safety communication between multiple machines (Multi Link module for safe data exchange between two PNOZmulti2 controllers)
권장되지 않음 (simple applications, discrete safety relays offer lower cost):
오직 1 dual-channel E-stop, no other safety signals, simple logic
No fieldbus, no motion monitoring, minimal safety I/O
📌 Typical Configuration Example (772138 해결책)
PNOZ I B0 (772100) + PNOZ m ES Profinet (772138) + EF I/O expansion modules
애플리케이션: Robot workstation / machining center. Safety logic runs independently inside PNOZmulti2. Profinet transmits safety status and fault codes to Siemens S7 PLC / HMI.
🔎 Core Strengths Matching Application Highlights
- Graphical drag-and-drop configuration, simple safety logic modification
- Modular architecture: 기본 유닛 + I/O 확장 + bus + motion modules assembled on demand
- Independent safety kernel: Safety logic runs autonomously, independent of upper PLC (core advantage of safety controllers. Protection remains valid even if main PLC fails.)
- Supports IP67 distributed remote I/O for large production lines
- Multi-axis safety motion monitoring, key selling point for machine tool and robot applications
- Rich fieldbus interfaces for seamless connection with mainstream PLC brands
접촉기,회로 차단기,감지기,인코더,PLC,변환기






















NH42-63-318x560.png)