Schneider LC1E1801 Contactor

모델 코드 설명: LC1E = TeSys E series contactor; 18 = rated 18A at 400V under AC-3 duty; 01 = built-in 1 상시 폐쇄 접점 (1NC) ⚠️ The LC1E series has been discontinued (production stopped in July 2020). The standard replacement model is LC1N1801, 장착 시 완벽하게 호환됨, terminal layout and performance. Key Specifications Main ...

  • 제품 세부정보

모델 코드 설명: LC1E = TeSys E series 접촉기; 18 = rated 18A at 400V under AC-3 duty; 01 = built-in 1 상시 폐쇄 접점 (1NC)

⚠️ The LC1E series has been discontinued (production stopped in July 2020). The standard replacement model is LC1N1801, 장착 시 완벽하게 호환됨, terminal layout and performance.

주요 사양

주요 연락처: 3피, 3아니요

AC-3 (모터 듀티): 18A @ 400V; AC-1 (저항 부하): 25에이

모터 정격: 7.5kW @ 380/400V; 4kW @ 220V; 9kW @ 440V

절연전압 Ui: 690다섯; 임펄스 내전압 Uimp: 6kV

보조 접점: 1NC (평상시 닫힘)

설치: DIN 레일 / base plate screw mounting

전체 치수: W45mm × H74mm × D80mm, net weight ≈0.3kg

보호 등급: IP20; 작동 온도: -5~+55℃; No derating up to 3000m altitude

기계적 수명: 10 백만 개의 작업; AC-3 전기적 수명: 1.2 백만 개의 작업; 최대 작동 주파수: 1800 주기/시간

Coil suffix definitions (complete model number)

LC1E1801B5: AC24V, 50헤르츠

LC1E1801F5: AC110V, 50헤르츠

LC1E1801M5: AC220V, 50헤르츠 (중국에서 가장 흔한)

LC1E1801Q5: AC380V, 50헤르츠

접미사 7 = 50/60Hz universal; 접미사 6 = 60Hz only

코일 전력 소비 (M5 220V example)

Inrush VA: 95버지니아; Sealed holding VA: 8.5버지니아; Coil heat dissipation: 2~3W

픽업 전압: 0.85~1.1Uc; 드롭아웃 전압: 0.3~0.6Uc

조임 토크 & wire gauge

Torque for main circuit and control circuit terminals: 1.2 N·m

단선: 1.5~6mm²; 연선 (페룰 포함): 1~4mm²

Matching selection reference

일치하는 열 과부하 계전기: LRD07 / LRN07 (current range suitable for 18A)

부속품: LA1EN auxiliary contact block, LA9D coil surge suppressor, mechanical interlock block

국내 대안: CJX2-1801 (similar outline, pay attention to mounting hole and marking differences)

문제 해결 가이드

  1. 코일에 전원이 공급되었으나 풀인이 없음: Check if coil voltage is within 0.85~1.1Uc; inspect broken coil wire and loose terminals
  2. Pulled in but main circuit no continuity: 주요 접점 침식, 접촉 용접, 느슨한 배선
  3. Buzzing / chattering: 저전압, large harmonic distortion, dust accumulated on core faces
  4. Failed to drop out after power-off: 용접된 주요 접점, core stuck by oil and dirt

Detailed Installation Procedure for 슈나이더 LC1E1801 Contactor

⚠️ Safety precondition: Operated by qualified electricians; cut off all power supply and verify zero voltage before installation. LC1E1801: 3P main contacts with built-in 1NC auxiliary contact. 단자 마킹: Main circuit L1/L2/L3 (line side, incoming), T1/T2/T3 (부하 측, outgoing); Coil A1, A2; 보조 접점: 95, 96 (1NC)

  1. 설치 전 준비
  2. 코일 전압 확인: LC1E1801M5=AC220V, Q5=AC380V, F5=AC110V. Coil rated voltage must match control circuit voltage to avoid coil burnout.
  3. 육안검사: No shell cracks, intact terminals, armature moves freely without jamming when pressed manually.
  4. 도구: 2 십자 드라이버, 와이어 스트리퍼, 멀티미터, 토크 렌치; 35mm standard DIN rail or mounting base plate.
  5. Wire specification

Main circuit solid wire: 1.5~6mm²; Stranded wire with ferrule: 1~4mm²

제어 회로 (A1/A2, 보조 접점): 0.75~1.5mm²

조임 토크: 1.2 N·m (avoid over-tightening to prevent thread stripping, or loose connection causing overheating)

  1. Environmental check: Cabinet temperature -5℃~+55℃, keep away from dust, 수분과 오일. Mount vertically upright. Do NOT install upside down or horizontally.
  2. 고정 (2 methods: DIN 레일 / base plate screw mounting)

방법 1: 35mm DIN 레일 장착 (우선의)

  1. The contactor has upper hooks and a spring locking clip at the bottom.
  2. Hook the upper notch onto the top edge of the DIN rail first.
  3. Press the bottom of the contactor down until you hear a click, the bottom clip locks onto the rail.
  4. Shake lightly to confirm firm fixation. 제거: Use a flat screwdriver to pry down the bottom clip and pull out the contactor.

방법 2: Screw mounting on insulated base plate (no rail)

  1. Mark and drill holes on the insulated plate according to the rear mounting holes (for M4 screws).
  2. Insert screws diagonally, pre-tighten, then torque evenly in diagonal sequence; do not force one side to avoid casing deformation.
  3. Accessory Fitting (선택 과목: LA1EN auxiliary block, mechanical interlock etc.)
  4. Top auxiliary contact block: Align with the slots on top of contactor, push vertically down until latched.
  5. Thermal relay LRD/LRN: Clip directly underneath the contactor, align positioning slots; the linkage will engage automatically.
  6. Surge suppressor LA9D: Clip beside coil terminals A1/A2, absorbs back EMF to protect PLC output points.
  7. 배선 순서 (Main circuit → Auxiliary contacts → Coil control circuit)

Standard routing: Line side on top, load side on bottom. L1/L2/L3 on top for three-phase supply; T1/T2/T3 at bottom for load (모터).

  1. 주회로 배선

Strip insulation 5~6mm, avoid loose copper strands; ferrules are mandatory for stranded wire.

Keep phase sequence L1→T1, L2→T2, L3→T3 as per drawing.

Torque screws to 1.2N·m; only one conductor per terminal.

  1. 보조접점 내장 (95-96, NC)

터미널 95-96: Conductive when coil de-energized, open when contactor pulls in. Usually used in stop circuit or fault feedback for motor control.

If NO contact is required, add LA1EN auxiliary block.

  1. Coil A1, A2 (제어 회로)

A1 and A2 have no polarity for AC. For AC220V: one to live, one to neutral; for AC380V: connect to two different phases.

Wire in series with start/stop pushbuttons, thermal relay NC contact or PLC outputs.

Route control wires separately from power cables to reduce interference.

Terminal summary:

L1/L2/L3 (Supply In), T1/T2/T3 (Load Out), A1 A2 (코일), 95-96 (1NC 내장)

  1. 전원 켜기 전 검사
  2. 육안검사: All terminals tightened, no exposed copper, no short circuit risk, no loose strands touching adjacent terminals.
  3. Continuity test with multimeter:

전원이 차단된 상태: No continuity between L-T; 95-96 auxiliary contact is conductive.

Manually press armature to simulate pull-in: L-T becomes conductive, 95-96 opens.

  1. Double-check coil voltage; separate power supply for main circuit and control circuit.
  2. 전원 공급 시 시운전
  3. Energize control circuit only, keep main power off: Press start button, contactor should pull-in smoothly without chattering or buzzing; release stop button for reliable drop-out.

수다쟁이: 낮은 공급 전압, loose wiring or dirty core surfaces.

  1. After control circuit test passes, energize main circuit and run on load.
  2. Temperature check after 10min running: No obvious overheating at terminals (temperature rise indicates poor connection).
  3. 설치 참고 사항 & 금지 사항
  4. Keep minimum clearance ≥10mm between contactor and fuse / MCB for heat dissipation.
  5. Minimum spacing ≥5mm between multiple contactors; increase spacing for high ambient temperature.
  6. Do not plug or remove auxiliary blocks when energized.
  7. Do not trap wire insulation inside terminal clamps; copper must be fully clamped.
  8. LC1E discontinued, spare replacement: LC1N1801, same mounting size and terminal definition.
  9. 일반적인 설치 오류

No pull-in after energized: Wrong A1/A2 voltage, broken control wire or open button circuit

Buzzing when pulled in: 저전압, dust or rust on magnetic core faces

Cannot drop out after power cut: Welded main contacts or core jammed by oil

Schneider Easy TeSys E (LC1E / 이지팩트 TVS) Series Full List

중요사항: LC1E series fully discontinued in July 2020. 직접 교체: LC1N series, identical mounting dimensions and terminal layout.

모델 규칙: LC1E + current code + auxiliary contact code (10=1NO; 01= 1NC) + coil suffix

Coil suffix description:

B5=AC24V 50Hz; F5=AC110V 50Hz; M5=AC220V 50Hz; Q5=AC380V 50Hz

B7/F7/M7/Q7=50/60Hz universal; BD=DC24V; 6=60Hz only

  1. 3P LC1E Contactors (AC-3 @400V)
기본 모델AC-3 전류Motor Rating @400VBuilt-in Auxiliary Contact
LC1E06106에이2.2kW1아니요
LC1E06016에이2.2kW1NC
LC1E09109에이4kW1아니요
LC1E09019에이4kW1NC
LC1E121012에이5.5kW1아니요
LC1E120112에이5.5kW1NC
LC1E181018에이7.5kW1아니요
LC1E180118에이7.5kW1NC (your referenced model)
LC1E251025에이11kW1아니요
LC1E250125에이11kW1NC
LC1E321032에이15kW1아니요
LC1E320132에이15kW1NC
LC1E381038에이18.5kW1아니요
LC1E380138에이18.5kW1NC
LC1E401140에이18.5kW1아니요+1NC
LC1E501150에이22kW1아니요+1NC
LC1E651165에이30kW1아니요+1NC
LC1E801180에이37kW1아니요+1NC
LC1E951195에이45kW1아니요+1NC
LC1E120120에이55kW내장 없음, add auxiliary block separately
LC1E160160에이75kW내장 없음, add auxiliary block separately
LC1E200200에이90kW내장 없음, add auxiliary block separately
LC1E300300에이160kW내장 없음, add auxiliary block separately

Example complete model: LC1E1801M7 = 18A, 1NC, AC220V 50/60Hz universal

  1. Matching LRE Thermal Overload Relays (plug-on fit for LC1E)

LRE01N~LRE35N (for 06~38A); LRE322N~LRE365N (for 40~300A)

LRE01N: 0.1~0.16A

LRE02N: 0.16~0.25A

LRE03N: 0.25~0.4A

LRE04N: 0.4~0.63A

LRE05N: 0.63~1A

LRE06N: 1~1.6A

LRE07N: 1.6~2.5A

LRE08N: 2.5~4A

LRE09N: 4~6A

LRE10N: 6~10A

LRE12N: 10~16A

LRE14N: 16~24A

LRE16N: 24~36A

LRE21N: 28~36A

LRE22N: 36~48A

LRE322N: 55~70A

LRE323N: 63~80A

LRE353N: 80~104A

LRE355N: 104~135A

LRE365N: 130~165A

  1. E-series Accessories
  2. LA1EN: Top-mounted auxiliary contact block (1아니요 / 1NC, stackable)
  3. LAEM1: 기계적 인터록 모듈 (for two contactor interlocking)
  4. LA9D: 코일 서지 억제기 (RC 네트워크 / 배리스터, PLC output protection)
  5. LAEB1N / LAEB3N: Thermal relay independent base (when not mounted under contactor)
  6. LA1EBN: Timed auxiliary contact block (지연 시 / 오프 딜레이)
  7. 2피 / 4P LC1E (single phase, 조명 & 저항 부하, AC-1 duty)

LC1E0920: 2질문 9A

LC1E2520: 2P 25A

LC1E0940: 4질문 9A

LC1E2540: 4P 25A

LC1E4040: 4P 40A

4P versions commonly used for HVAC, lighting and heating resistive loads

  1. Cross Reference Table
Old LC1E ModelDirect Replacement LC1N
LC1E0601/0610LC1N0601 / LC1N0610
LC1E0901/0910LC1N0901 / LC1N0910
LC1E1201/1210LC1N1201 / LC1N1210
LC1E1801/1810LC1N1801 / LC1N1810
LC1E2501/2510LC1N2501 / LC1N2510
LC1E3201/3210LC1N3201 / LC1N3210
LC1E3801/3810LC1N3801 / LC1N3810
LC1E40~95LC1N40~95

이전:

답장을 남겨주세요

메시지를 남겨주세요