제품 시리즈: Zelio Count
제품 유형: Electromechanical Totalising Counter
상태: 단종 (단종). No direct replacement model; alternative selection is required.
계산 모드: Up-count only. Values are permanently retained upon power loss; no battery required.
표시하다: 6-digit mechanical roller display, range 0~999999, digit height 4 mm.
모델 디코딩
XBK T 6 0000 U10M
XBK: Zelio Count counter family
티: Totalising counter
6: 6-자리 표시
유: 24 V DC 전원 공급 장치
10: With manual reset knob (Version U00M = XBKT60000U00M without reset)
중: Version suffix
핵심 전기 & 기계적 매개변수
| 목 | 사양 |
| 정격 공급 | DC24V (±10%, 19.2~26.4V DC) |
| 맥스. Counting Frequency | 25 헤르츠 |
| 입력 유형 | Passive dry contact input (triggered by contact signal) |
| 전력 소비 | 대략. 0.15 여 |
| 재설정 방법 | Front-panel manual mechanical reset |
| 기계적 수명 | ≥10,000,000 counting cycles |
| 설치 | Panel flush mounting |
| 전반적인 차원 | 20(시간) × 30(여) × 42(디) mm |
| 종료 | AMP quick-disconnect lugs |
| 작동 온도 | -40℃ ~ +85℃ |
일반적인 애플리케이션 시나리오
Equipment operation cycle counting, production line workpiece counting, total output statistics for stamping/packaging/textile machinery. Suitable for low-speed contact pulse signals (proximity switches, 리미트 스위치, relay contacts). Not applicable for high-frequency pulses.
문제 해결 가이드
- No counting: Check 24V power supply; verify reliable ON/OFF of input contacts. Contact bounce may cause missing counts; confirm pulse frequency ≤25 Hz.
- 재설정 실패: Jammed manual reset mechanism or worn internal gears (common ageing fault for electromechanical counters).
- Erratic counting / extra counts: Contact bounce; add RC debounce circuit; pulse frequency exceeds 25 헤르츠.
- Stuck digits: Worn internal gears, irreversible mechanical damage; 교체 필요.
Alternative Selection (Replacement for Discontinued Unit)
- Equivalent mechanical counters: Compare panel cutout dimensions. Select alternative 6-digit electromechanical totalising counters, verify reset function and 25 Hz limit.
- Electronic pulse counters: 슈나이더 XBT series or domestic electronic counters, support higher frequency, external power supply required, some models offer power-fail data retention.
메모: Mechanical models limited to 25 Hz max. Electronic counters must be selected if field pulse >25 헤르츠.
설치 & 부속품
Panel cutout size 20×30 mm, front panel snap-in mounting; AMP lug wiring, incompatible with standard screw terminals.
Typical Application Cases of Schneider XBKT60000U10M Electromechanical Totalising Counter
Core characteristics preamble: 6-digit mechanical accumulation, DC24V supply, dry contact input, 최대 25 헤르츠, front panel manual reset, permanent value retention after power loss. Optimized for low-speed contact pulse scenarios; unsuitable for high-frequency pulses.
사례 1: Stamping Machine – Cumulative Mold Stroke Counting
대본
작은 & medium mechanical stamping press, total stroke counting for mold life management. Schedule maintenance/mold repair once target stroke count is reached.
해결책
- Signal Acquisition: Limit switch actuated when slide reaches bottom dead centre, dry contact signal wired to XBKT counter input; DC24V sourced from machine control circuit.
- 설치: Embedded into machine operation panel, 20×30 mm cutout.
- 논리: +1 count for every completed stamping cycle upon contact closure; count value preserved after power cut. Rotate front reset knob to zero when mold is replaced.
장점
Direct-read mechanical rollers, readable under strong light and dusty workshop environments; no battery required to retain cumulative data.
제한사항
Stamping cycle frequency cannot exceed 25 counts/second. RC debounce is required to avoid miscounting caused by contact bounce.
사례 2: Packaging Line – Total Finished Carton Output Counting
대본
Low-speed carton packaging line (주기 >0.04 에스). Count total cartons off the line for shift/monthly production logging, acting as independent hardware backup counter separate from PLC.
해결책
Photoelectric proximity sensor detects carton presence and outputs dry contact pulse to XBKT; PLC performs real-time monitoring, while XBKT serves as independent hardware totaliser.
값
Cumulative production data remains intact even if PLC stops or power fails, preventing data loss. Operators read values directly without PC access. Manual reset for new production shifts.
사례 3: Injection Molding Machine – Mold Open/Close Cycle Counting
대본
Horizontal injection molding machine. Count total mold open-close cycles to predict wear on mold, guide pins and ejector pins for predictive maintenance planning.
해결책
Use limit switch signal triggered when mold is fully closed to drive counter; DC24V from injection machine control power supply.
Key Points
Capture stable mold fully closed signal only. Avoid solenoid valve signals (prone to bounce and false counts).
Count value retained during power-off maintenance; manual reset upon mold replacement.
사례 4: Conveyor Sorting Equipment – Cumulative Material Count
대본
Low-speed belt sorting line (material interval >40 ms). Count total workpieces passing through sorting station.
해결책
Diffuse photoelectric sensor detects incoming material and sends dry contact pulse; XBKT performs total accumulation.
Suitable for cartons and large workpieces. Not recommended for high-speed small-item sorting (frequency exceeding 25 헤르츠), electronic counters required instead.
사례 5: Hydraulic Equipment – Cylinder Actuation Cycle Count
대본
Hydraulic workholding fixtures and hydraulic bending machines. Count reciprocating cylinder cycles to evaluate service life of seals and cylinder assembly.
해결책
Magnetic proximity switch triggered when cylinder fully extends, dry contact pulse for counting; unit installed inside control cabinet panel.
특징
Robust mechanical gear design suitable for high vibration industrial environments; immune to EMI interference from variable frequency drives and will not lose counts.
사례 6: Valve Test Bench – Valve Opening/Closing Durability Cycle Test
대본
Fatigue life test bench for gate valves and butterfly valves. Count total valve open-close cycles.
해결책
Limit switch at fully open valve position provides counting pulse; 24 V DC 공급. Manual reset when test batch changes.
Matches XBKT’s strength for low-speed dry-contact counting and power-fail retention, acts as hardware checksum against upper computer logged data.
General Notes for Selection & 작업 (모든 경우에 적용 가능)
- 25 Hz pulse limit: Event interval ≥40 ms. Electronic counters must be used for faster cycles.
- Dry contact input only: Accept relays, limit switches and proximity switch passive contacts; cannot connect voltage pulses directly.
- Environmental tolerance: -40~+85°C operating range, suitable for dusty workshops; avoid heavy oil immersion on digit window.
- 제품상태: 이 모델은 단종되었습니다. Not recommended for new projects. Spare part replacement for existing machines can use alternative domestic 6-digit electromechanical counters or Schneider electronic counters.
Counting Accuracy of Schneider XBKT60000U10M
This is an electromechanical totalising counter. Unlike measuring instruments with percentage accuracy, official datasheets do not specify ±xx% error. Core definition: Under rated operating conditions, 1 pulse = 1 count with zero pulse error.
- Counting Resolution
1 count (1 손가락). 6-digit mechanical roller, display range: 000000 ~ 999999, minimum counting unit = 1 event.
- Nominal Counting Accuracy (Ideal Operating Condition)
All conditions met: 1 valid input pulse = accurate +1 increment, no inherent counting error
Dry contact input pulse ≤25 Hz
Good contact debounce with no bounce or duplicate pulses
DC24V supply within 19.2~26.4 V
작동 온도 -40 ~ +85°C, no continuous heavy shock/vibration
Intact mechanical gears without jamming or wear
자연: It is an event counter, not a metering instrument. New unit under rated conditions will not lose or add spurious counts, no percentage error defined in factory documentation.
- Sources of Field Count Error (Not inherent counter inaccuracy)
- Contact bounce (most frequent cause): Mechanical bounce of limit/relay contacts generates multiple pulses from one single action → extra counts.
- Pulse frequency over 25 헤르츠: Signals arrive faster than internal electromagnetic mechanism can respond → lost counts.
- Ageing and mechanical wear: Long-term operation causes gear wear and jamming → missed counts or stuck digits (ageing failure, requires replacement).
- Supply voltage drop: Insufficient voltage fails to pull in electromagnetic actuator → no counting action.
- 중요한 구별
✅ New unit with compliant pulses: Counting Accuracy = ±0 counts
❌ Percentage error metrics like ±0.1%, ±1% do NOT apply; no such parameter in official documentation.
Visual reading error for mechanical rollers: Max ±0.5 digit, occurs when roller sits between two numerals (human reading deviation).
- 선택 팁
For metering-grade precision (percentage error requirement), electromechanical counters such as XBKT are unsuitable. Electronic pulse counters are recommended.
접촉기,회로 차단기,감지기,인코더,PLC,변환기