Siemens 3RT2025-1AC20 Motor Contactor

제품 시리즈: SIRIUS 3RT2 3-pole Power Contactor (Motor Contactor) Full Order No.: 3RT2025-1AC20 ✅ Model Code Explanation 3RT: SIRIUS contactor series 2: New generation SIRIUS Innovations 0: 3-pole motor contactor 25: S0 frame size, AC-3 17A, rated for 7.5kW motor at 400V 1: Built-in 1NO + 1NC auxiliary contacts A: AC coil C: 24뷔와, ...

  • 제품 세부정보

제품 시리즈: SIRIUS 3RT2 3-pole Power Contactor (Motor Contactor)

Full Order No.: 3RT2025-1AC20

✅ Model Code Explanation

3RT: SIRIUS contactor series

2: New generation SIRIUS Innovations

0: 3-pole motor contactor

25: S0 frame size, AC-3 17A, rated for 7.5kW motor at 400V

1: Built-in 1NO + 1NC 보조 접점

에이: AC 코일

기음: 24뷔와, 50/60헤르츠 코일

20: Screw-type terminal

✅ Core Technical Specifications

매개변수
Main Contacts Poles3피 (3 상시 개방형 주 접점)
Rated Current AC-317@400V
Rated Current AC-1 (저항 부하)40에이
맥스. 작동 전압690다섯
코일24뷔와, 50/60헤르츠
보조 연락처1아니요 + 1NC
프레임 크기S0
배선 유형나사 터미널
설치DIN 레일 장착
보호 등급IP20 (앞쪽 / 터미널)
주변 작동 온도-25℃ ~ +60℃
기계적 수명10 백만 개의 작업

✅ Typical Applications

Start/stop control of 3-phase asynchronous motors (팬, 슬리퍼, 컨베이어)

공조, 포장, machine tool automation control cabinets

Can be matched with 3RU2 thermal relays for motor overload protection; 보조 접점, surge suppressors and mechanical interlock modules can be added.

✅ Coil Variant Reference for Selection & 대사

3RT2025-1AC20: 24뷔와

3RT2025-1AG20: 110뷔와

3RT2025-1AN20: 220뷔와

3RT2025-1AP00: 230뷔와

3RT2025-1BB40: 24DC에서

✅ Replacement Information

  1. 지멘스 internal replacement: Old model 3RT1025-1AC20 (단종). Direct replacement with 3RT2025-1AC20, mounting dimensions are compatible.
  2. 국내 대체 참고자료: Chint NC1-18, Delixi CJX2-1810 (match coil voltage and confirm 1NO+1NC auxiliary contacts).

✅ Troubleshooting Guidelines

  1. Coil energized but no pull-in: Measure A1/A2 for 24V AC; check burnt coil and loose terminals.
  2. No output on main circuit after pull-in: Main contacts erosion, inspect L1/L2/L3 and T1/T2/T3.
  3. Repeated coil burnout: Overvoltage or surge on coil circuit. RC snubber module is recommended for parallel connection.
  4. Abnormal auxiliary contacts: Auxiliary contacts worn out. External auxiliary contact modules can be fitted.

The built-in 1NO+1NC auxiliary contacts integrated inside 3RT2025-1AC20 cannot be replaced separately.

They are integrated into the contactor housing with no spare parts available. Once the built-in auxiliary contacts are damaged, the whole contactor must be replaced.

Distinguish two concepts:

  1. 내장형 보조 접점 (1아니요+1NC): Integrated inside S0 frame body, non-detachable and non-replaceable individually.
  2. External add-on auxiliary contact modules (전면 장착 / 측면 장착): Detachable and replaceable separately, classified as accessories.

📌 External Auxiliary Contact Module Selection (분리 가능 & 교체 가능)

1) 전면 장착 (fit only 1 piece on front face)

3RH2911-1HA11: 1아니요+1NC

3RH2911-1HA22: 2아니요+2NC

2) 측면 장착 (can be fitted on left or right side, 최대 2 조각, one on each side)

3RH2921-1DA11: 1아니요+1NC

3RH2921-1DA20: 2아니요

3RH2921-1DA02: 2NC

🛠️ Fault Handling Solutions

  1. Burnt built-in auxiliary contacts: No spare parts available; replace the entire 3RT2025-1AC20 contactor.
  2. Damaged external auxiliary contact module: Remove the faulty auxiliary contact module and replace it with the same model accessory; reuse the contactor body.
  3. Insufficient contact quantity: Add front/side mounted auxiliary contact modules listed above.

⚠️ Additional Remarks

For S0 frame (3RT2025), no separate spare main contact kits are available. The whole contactor needs replacement when main contacts are burned. Only S2 and larger frame contactors have independent spare main contacts.

Siemens 3RT2025-1AC20 Main Contacts vs Auxiliary Contacts

  1. 정의 & 기능

주요 연락처 (L1/L2/L3 ↔ T1/T2/T3)

기능: Switch high-power main circuit, directly turn on/off motors and loads

수량: 3 normally-open sets (3피)

평가: AC-3 17A@400V for 7.5kW motor; AC-1 40A for resistive load

회로: High-power main circuit

구조: Oversized thick silver-alloy contacts with arc extinguishing chamber to withstand breaking arc under high current

주목: S0 프레임, main contacts cannot be replaced individually. Full contactor replacement required after damage.

보조 연락처 (Built-in 1NO+1NC, expandable with 3RH accessories)

기능: Signal feedback, 연동, 래칭 (control circuit logic, not for high-power load driving)

수량: Built-in 1NO +1NC. Expandable by external modules

평가: Low current, typically ≤6A for PLC input, relay coils and indicator lamps

회로: Low-power control circuit

구조: Small silver contacts without heavy-duty arc extinguishing, only for small current breaking

주목: Built-in auxiliary contacts are integrated and non-replaceable; external 3RH auxiliary modules can be assembled and replaced individually.

  1. 비교표
비교항목주요 연락처Built-in Auxiliary Contacts
터미널 마킹L1/L2/L3, T1/T2/T313/14 (NO 평상시 열림), 21/22 (NC 상시 폐쇄)
부하 용량High current for motors and heatersLow current only for signal, interlock and latching
정격전류AC-3:17@400VTypically 6A (AC-15)
아크 소화With arc chute for heavy arcNo heavy-duty arc suppression, only for minor arc
Individually Replaceable❌ Not available (S0 프레임)❌ Built-in non-replaceable; ✅ External auxiliary modules replaceable
일반적인 사용법Main power supply switching for motorsContactor latching, running feedback, 연동, 표시 램프, PLC acquisition
  1. Typical Wiring Example
  2. 주요 연락처: 3-phase power supply feeds L1/L2/L3 on contactor top terminals; bottom terminals T1/T2/T3 connect to motor.
  3. 보조 연락처

13-14 (NO 평상시 열림): Latching circuit or send “contactor energized” feedback signal to PLC.

21-22 (NC 상시 폐쇄): 전기적 인터록 (forward/reverse circuit, prevent simultaneous pull-in of two contactors causing 3-phase short circuit).

  1. Fault Differentiation

Main Contacts Failure: Motor weak rotation, 위상 손실, overheating or arcing at terminals, load cannot power up normally.

Auxiliary Contacts Failure: Motor can start/stop normally, but latching fails, loss of feedback signal, interlock invalid. Main power circuit remains unaffected.

  1. Important Warning

Never use auxiliary contacts to switch motors, heaters or other high-power loads. Contact erosion will occur rapidly. High-power loads must be wired via main contacts.

Siemens 3RT2025-1AC20|Application Scenarios of Main Contacts and Auxiliary Contacts

  1. 주요 연락처 (L1/L2/L3 ↔ T1/T2/T3, 3 sets of high-power normally-open contacts)

Core purpose: Switch high-power main circuit and carry load operating current

✅ 적용 가능한 시나리오:

  1. Direct start-stop of 3-phase motors (가장 일반적인): 슬리퍼, 팬, 컨베이어, 공기 압축기, machine tool spindle motors. This model is rated for 7.5kW 400V 3-phase motors.
  2. 3-phase resistive load control: 3-phase heating elements, large 3-phase dehumidification heaters, max 40A under AC-1 rating.
  3. High-power switching in power distribution circuits: Power switching for heavy loads inside control cabinets.

❌ Not suitable for:

PLC 신호, indicator lamps, small relay coils and other low-current control circuits;

Logical interlock or status feedback.

특징: Equipped with arc extinguishing chamber and thick silver contacts, withstand motor inrush current and breaking arc.

  1. 보조 연락처 (Built-in 1NO+1NC, 터미널:13-14 아니요,21-22 NC; expandable with 3RH external modules)

Core purpose: Low-current signal in control circuit, only transmit logic status, no high-power load driving

✅ Normally Open NO (13-14) 일반적인 시나리오

  1. Contactor latching (self-holding): Maintain coil energized after releasing start pushbutton to keep motor running continuously.
  2. Running status feedback: Send signal to PLC, DIO module or indicator lamp for HMI to display “contactor pulled in, equipment running”.
  3. Sequential startup: Use NO contact to trigger coil of next relay/contactor after this contactor pulls in, to realize sequential start-up.

✅ Normally Closed NC (21-22) 일반적인 시나리오

  1. 전기적 인터록 (classic application): Connected in series to coil circuit of reverse contactor in forward/reverse control circuit, to avoid 3-phase short circuit caused by simultaneous pull-in of forward and reverse contactors.
  2. 잘못 / stop feedback: NC closed when contactor is open, used for stop status acquisition.
  3. Safety circuit interlock: NC contact conducts when contactor is de-energized, serving as ready signal.

Auxiliary contacts are low rated (AC-15 approx.6A), only for low-current control circuits. Do NOT use auxiliary contacts to directly control motors or high-power heating loads.

Quick Selection Rule

모터, high-power heaters, 3-phase power → Main Contacts

래칭, 연동, PLC signal, running indicator lamp, logic linkage → Auxiliary Contacts

On-site Quick Fault Diagnosis

Motor fails to run, 위상 손실, hot or arcing terminals → Most likely main contact fault

Motor can start and stop, but stops immediately once start button released, no running feedback, risk of short circuit due to failed interlock → Most likely auxiliary contact fault