Chint thermal overload relays with a setting current range of 135-160A (including the adjustable interval of 135-160A) are mainly available in the following 4 시리즈, covering both old and new product lines and adapting to different installation and functional requirements:

  1. Core Adaptable Series & Model Overview
시리즈명Frame Model전류 범위 설정핵심 기능장착 방법Adaptable Contactors
JR36 Series (Classic Standalone Type)JR36-160100-160에이 (adjustable to 135-160A)Bimetallic strip type, 위상 오류 보호, temperature compensation, 10A trip classStandalone MountingTraditional contactors such as CJT1-100, CJT1-150
NR2 Series (Mainstream Plug-in Type)NR2-200100-160에이 (adjustable to 135-160A)Plug-in design, action indication, automatic/manual reset, 10A trip class플러그인 + 독립형NC2-160, NC2-200, 등.
NXR Series (KunLun New Generation)NXR-20080-160A/100-160A (adjustable to 135-160A)Added test/stop function, upgraded protection, 더욱 안정적인 성능플러그인 + 독립형Chint KunLun contactors such as NC3-160, NC3-200
NR4 Series (JRS2 Industry Designation)NR4-200100-160에이 (adjustable to 135-160A)Three-phase bimetallic strip, 차동 위상 오류 보호, temperature compensation, 10A trip class플러그인 + 독립형Universal for NC series
  1. Comparison of Key Parameters of Each Series
비교항목JR36 SeriesNR2 SeriesNXR SeriesNR4 Series
정격전압690V AC/50/60Hz690V AC/50/60Hz690V AC/50/60Hz690V/1000V AC/50/60Hz
Maximum Setting Current160에이630에이 (full series)630에이 (full series)180에이 (full series)
여행 클래스10에이10에이10에이10에이
보조 연락처1아니요+1NC (partial models)1아니요+1NC1아니요+1NC1아니요+1NC
기능적 차이기본 보호, simple structureStandard functions, 높은 시장 점유율Comprehensive functions, new generation main productIndustry universal, 강력한 호환성
적용 가능한 시나리오Renovation of old equipment, standalone mounting requirementsNew construction projects, mainstream application of plug-in typeHigh-end projects, functional upgrade requirementsExport/industry supporting, JRS2 standard adaptation

III. Key Points for Selection and Application

  1. Current Matching Principle: 135-160A is the upper adjustment limit of the 100-160A specification. Ensure the rated load current ≤ 160A and the long-term operating current ≤ 135A (에이 10% margin is reserved).
  2. Mounting and Heat Dissipation:

Reserve ventilation space for standalone mounting and avoid enclosed environments;

When the ambient temperature > 40℃, derate the load current by 10% for every 10℃ rise (예를 들어, 135-160A shall be derated to 121.5-144A at 50℃);

Ensure a firm snap connection with the contactor for plug-in mounting to maintain stable contact resistance.

  1. 교체 권장사항:

Prioritize the NXR Series for new designs (optimal performance, complete functions);

The NR2 Series is an option for replacement of in-service equipment (좋은 호환성, moderate cost);

The JR36 Series is available for maintenance of old systems (direct replacement without changing the mounting method).

  1. Examples of Complete Markings for Common Models

JR36-160 100-160A (Chint classic standalone thermal overload relay)

NR2-200 100-160A (mainstream plug-in type, adaptable to NC2 contactors)

NXR-200 100-160A (KunLun series, new generation thermal overload relay)

NR4-200 100-160A (JRS2 industry standard, adaptable to various contactors)

요약: Chint 135-160A thermal overload relays cover four major series: JR36 (classic), NR2 (mainstream), NXR (새로운 세대) and NR4 (industry standard). All adopt a bimetallic strip design with phase failure protection and temperature compensation functions. Users can select the appropriate series according to mounting methods, functional requirements and budgets.

 