 Allen‑Bradley 20G11NC011AA0NNNNN AC Drive

PowerFlex 755 Air-Cooled AC Variable Frequency Drive (VFD) Lifecycle: Obsolete (Last order date: 2024‑06‑30). Direct OEM replacement part number: 20G11NC011JA0NNNNN Catalog Number Breakdown (20G Series Coding Rule) 20G 1 1 N C 011 A 0 NNNNN Segment Code Description 1~3 20G PowerFlex 755 air-cooled AC drive series 4 1 Embedded EtherNet/IP, standard protection, forced air ...

  • Product Details

PowerFlex 755 Air-Cooled AC Variable Frequency Drive (VFD)

Lifecycle: Obsolete (Last order date: 2024‑06‑30). Direct OEM replacement part number: 20G11NC011JA0NNNNN

  1. Catalog Number Breakdown (20G Series Coding Rule)

20G 1 1 N C 011 A 0 NNNNN

SegmentCodeDescription
1~320GPowerFlex 755 air-cooled AC drive series
41Embedded EtherNet/IP, standard protection, forced air cooling
51AC input with DC bus terminals
6NIP20 / IP00, Open Frame (NEMA Open Type)
7C400V three-phase (380~480VAC)
8~1011Rated output current 11.5A
11AIntegrated Dynamic Braking Transistor (DB Transistor)
120No HIM keypad (blank)
13~17NNNNNNo additional option modules
  1. Key Electrical Specifications

Rated Current: 11.5A

Voltage Class: 3-phase 400V AC

Power Rating:

ND (Normal Duty): 5.5kW

HD (Heavy Duty): 4kW

Frame Size: Frame 2

Cooling: Forced air cooling

Communication: Embedded EtherNet/IP (DLR ring support)

Dynamic Braking: Built-in DB transistor, external braking resistor required

Enclosure Rating: IP20 (for cabinet mounting only)

Input: AC main circuit with brought-out DC bus terminals, suitable for common DC bus applications

  1. Typical Applications

Conveyors, fans, pumps, extruders and general-purpose industrial motor speed control; supports multi-axis EtherNet/IP motion control and can share the same network with Kinetix servo drives.

  1. Hardware & Maintenance Notes
  2. Obsolete notice: After discontinuation of AA0 suffix legacy units, JA0 is the drop-in compatible replacement. Mounting dimensions, I/O and program parameters are fully compatible for direct replacement.
  3. Optional Accessories: HIM keypad (20‑750‑HIM), input EMC filter, dynamic braking resistor, Safe Torque Off (STO) module.
  4. Common failure points: Fan aging, DC bus capacitor degradation, ESD damage on EtherNet/IP port; for spare part replacement, prioritize OEM JA0 version.
  5. Domestic Alternative Reference (Same rating 400V /11.5A VFD)

Inovance MD880, V&T AC800, Xinje DS500. Hardware replacement is feasible, but communication program, parameter groups and terminal definitions require re-commissioning. Cannot directly inherit the original Rockwell EtherNet/IP motion link.

  1. HS Code Reference

8504409990 (Other static converters, general classification for VFDs. Final customs classification subject to local customs authority.)

PowerFlex755 (20G11NC011AA0NNNNN) Power-On Commissioning Parameter List

Applicable: 400V, ND 5.5kW / HD 4kW, embedded EtherNet/IP, integrated braking transistor. Structure: Pre-power-on inspection → Factory reset → Motor nameplate data → Control mode → Start / Speed reference source → Accel/Decel & limits & protection → Autotune → EtherNet/IP communication → Dynamic braking & fault strategy → Monitoring parameters

Note: Parameter numbers refer to Port0 (drive native parameters). Actual values from motor nameplate must be entered on site. Italic values below are examples.

  1. Pre-Power-On Hardware Check (Not parameters, mandatory before commissioning)
  2. Main circuit: 3-phase input R/S/T, output U/V/W, DC bus, braking resistor wiring and earthing.
  3. Control circuit: 24V control supply, STO safety terminals must be shorted (short required if no STO module, otherwise safety fault alarm).
  4. Motor decoupling recommended: Disconnect mechanical load before initial autotune.
  5. Rating verification: Drive rated 11.5A, match motor rated current.
  6. Factory Reset (New project / After repair)
Parameter No.English NameChinese NameSettingRemarks
5Reset To Default恢复出厂Options>Factory ResetTakes effect after power cycle; clears all custom parameters. Recommended for new commissioning.
  1. Motor Nameplate Parameters (Critical, enter from nameplate)
Parameter No.English NameChinese NameExample ValueRemarks
26Motor NP FLA电机额定电流10.5AMotor full load current from nameplate, shall not exceed drive 11.5A
27Motor NP Hertz电机额定频率50HzFrom nameplate
28Motor NP RPM电机额定转速1480RPMFrom nameplate
29Mtr NP Pwr Units电机功率单位0=kW /1=HP0=kilowatt
30Motor NP Power电机额定功率5.5kWFrom nameplate
31Motor NP Volts电机额定电压380VFrom nameplate
  1. Control Mode (TotalFORCE, for induction motors)
Parameter No.English NameChinese NameRecommended SettingRemarks
35Motor Cntl Mode电机控制模式2=Sensorless VectorPreferred for fans/pumps/conveyors;
use 3=Flux Vector for high precision torque control (encoder required)
  1. Command Source & Speed Reference Source (Select ONE: Terminal Control / EtherNet/IP Network Control)

Option A: EtherNet/IP Network Control (Built-in port standard on this unit, most common for projects)

Parameter No.English NameChinese NameSettingRemarks
160Start Source启动命令源Port13 (Embedded EtherNet/IP)Start/stop command from Logix controller
161Speed Ref Source速度给定源Port13 (Embedded EtherNet/IP)Speed reference from network

Option B: Local Terminal Control (Commissioning test / Standalone test)

Parameter No.English NameChinese NameSettingRemarks
160Start Source启动命令源Digital Input (DI Terminal)Start/stop via DI terminals
161Speed Ref Source速度给定源Analog Input 0 (AI0)AI analog 0-10V /4-20mA reference
163DI Run数字输入 – 运行DI0DI0 = Run command
164DI Stop数字输入 – 停止DI1DI1 = Stop (normally closed for safety)
  1. Accel / Decel & Limit Parameters
Parameter No.English NameChinese NameExampleRemarks
53Accel Time 1加速时间 15.0sExtend for heavy load; 8~20s for fans/pumps
54Decel Time 1减速时间 15.0sExtend for high inertia loads; can shorten if braking resistor fitted
55Max Freq最大频率50HzMaximum operating frequency, do not exceed motor nameplate
56Min Freq最小频率0HzMinimum output frequency
57Speed CLIP Hi最高转速限幅1480RPMMatches motor rated speed
  1. Current / Torque Protection Parameters
Parameter No.English NameChinese NameExampleRemarks
42Motor OL Current电机过载保护电流Motor nameplate FLAMotor thermal protection, use nameplate value
44Motor OL Select电机过载保护模式1=Class10Class10 for standard induction motors; Class20 for heavy duty
47Current Limit 1电流限幅11.5ADrive rated output current
49Torque Limit Pos正向转矩限幅150%Default 150%; reduce for hoist applications
50Torque Limit Neg反向转矩限幅150%Reverse torque limit
  1. Motor Autotune (Critical! Run after entering nameplate data)
Parameter No.English NameChinese NameOperationRemarks
70Autotune电机自整定Static Tune 2Motor decoupled from load before autotune.
Static Tune: No motor rotation.
Rotational Tune: Motor spins, higher accuracy for commissioning

After successful autotune, parameter 70 automatically returns to Ready 0. If autotune fails, check wiring, nameplate entries and short-circuit to earth.

  1. Embedded EtherNet/IP Communication Parameters (Port13 Embedded Adapter)
Parameter No.English NameChinese NameSettingRemarks
36BOOTPBOOTP 模式0=BOOTP DisabledFor static IP addressing
37IP AddressIP 地址192.168.1.10Site planned IP address
38Subnet Mask子网掩码255.255.255.0Match subnet segment
39Gateway网关192.168.1.1Gateway address
84Comm Flt Action通讯丢失动作0=Fault (Fault Trip)Network break protection; optional 1=Coast, 2=Hold Speed
85Idle Flt Action控制器 Idle 动作0=FaultDrive action when PLC enters idle state

Hardware DIP switch: All DIPs set to 0 to allow software-configured IP. If DIPs are non-zero, IP is determined by hardware switches.

  1. Dynamic Braking Parameters (A suffix = integrated DB transistor on this model)
Parameter No.English NameChinese NameExampleRemarks
100DB Resistor Ohms制动电阻阻值Enter actual resistor valueMust match fitted external braking resistor
101DB Resistor Power制动电阻功率Actual power rating
102DB Level制动投入电压780VDefault for 400V class drives
103DB Overload制动电阻过载保护Set per resistor selection
  1. Auto Restart on Fault (Optional, safety hazard risk)
Parameter No.English NameChinese NameSettingRemarks
348Auto Rstrt Tries自动重启次数0=Disabled1~5 allowed for fans/conveyors; DO NOT enable for safety-critical machinery
349Auto Rstrt Delay重启延时5sDelay between each fault restart attempt
  1. Read-only Monitoring Parameters (For observation only, no write)
Parameter No.English NameChinese NamePurpose
10Output Freq输出频率Actual output frequency
11DC Bus Volts直流母线电压Normal ~540~580V for 400V class
12Output Current输出电流Actual motor current
13Motor Speed电机转速Estimated motor speed
220Digital In Sts数字输入状态Diagnose DI terminal status
  1. Standard Commissioning Procedure
  2. Power off → Factory reset parameters → Apply power
  3. Enter all motor nameplate parameters
  4. Configure control mode, command source and reference source
  5. Set accel/decel, limits and overload protection
  6. Run motor autotune with load decoupled, confirm autotune success
  7. EtherNet/IP: Set IP address, download PLC project, establish I/O connection
  8. No-load jog test, verify rotation direction, current and speed
  9. Loaded trial run, fine-tune accel/decel and torque limits
  10. Save parameters to drive (parameter backup), export via Studio5000
  11. Record and archive full parameter set
  12. Common Commissioning Pitfalls
  13. STO safety terminals: 20G11NC011AA0NNNNN has no STO module; STO jumpers on control board must be shorted, otherwise safety fault on power-up.
  14. Autotune fault: Check for open 3-phase motor wiring, nameplate data entry and earth short circuit.
  15. Replacement 20G11NC011AA0NNNNN → 20G11NC011JA0NNNNN: Parameters can be uploaded/downloaded directly, nearly fully compatible; only verify firmware version.

4. High inertia loads: Extend deceleration time or select higher rated braking resistor