 PHOENIX 2904371 DIN Rail Switching Power Supply

Full Order Code: UNO-PS/2AC/24DC/90W/C2LPS Phoenix Contact UNO POWER Series 2-Phase Input DIN Rail Power Supply ✅ Key Specifications Input: 2-phase AC 400~500 V AC (Wide range: 264–575 V AC) Output: 24 V DC, rated current 3.75 A, 90 W Adjustable output voltage: 24~28 V DC (via potentiometer) Output ripple: <50 mVpp Overvoltage protection (OVP): ≤35 ...

  • Product Details

Full Order Code: UNO-PS/2AC/24DC/90W/C2LPS

Phoenix Contact UNO POWER Series 2-Phase Input DIN Rail Power Supply

✅ Key Specifications

Input: 2-phase AC 400~500 V AC (Wide range: 264–575 V AC)

Output: 24 V DC, rated current 3.75 A, 90 W

Adjustable output voltage: 24~28 V DC (via potentiometer)

Output ripple: <50 mVpp

Overvoltage protection (OVP): ≤35 V DC

No-load power consumption: <0.7 W

Power factor cosφ: 0.48

Protection class: IP20

Mounting: NS35 DIN rail

Operating temperature: -25℃ ~ +70℃; derating 2.5% per Kelvin above 55℃

Terminals: Screw-type clamping terminals

C2LPS = NEC Class 2 output certification + hazardous area approval (Class I, Division 2, T4). The output circuit can be wired per Class 2 requirements without extra isolation or protective sheathing, suitable for powering PLCs, sensors and valve islands in explosion-proof cabinets.

No parallel or series connection allowed

✅ Typical Applications

Control cabinets with 400V two-phase power supply, hazardous locations, construction machinery, HVAC, wind turbine auxiliary control systems; power supply for PLCs, proximity switches, solenoid valves and HMIs.

Important distinction: Unlike conventional single-phase 220V UNO power supplies, this model is a high-voltage two-phase input version, which is frequently misselected on site.

✅ Replacement Reference

Single-phase counterpart in the same series: 2902994 (UNO-PS/1AC/24DC/90W/C2LPS), input range 85–264 V AC. Do not interchange the two models.

For higher power with the same structure: UNO 150W & 240W two-phase variants.

✅ Troubleshooting Guide

  1. DC OK indicator off: First verify two-phase input voltage. The unit will not start under phase loss or input voltage below 264 V AC.
  2. Excessive voltage drop under load: Check for overcurrent or temperature-induced derating.
  3. Frequent protection trips: Load short circuit or output earth fault. Class 2 models feature highly sensitive short-circuit protection.

PHOENIX 2904371 (UNO-PS/2AC/24DC/90W/C2LPS) Installation Manual

Safety Precondition: Indoor cabinet mounting only, IP20 rating. C2LPS stands for Class 2 output plus Class I Division 2 hazardous area certification. All installation in explosive environments must comply strictly with ISA-12.12.01 standards.

  1. Product Overview

Order No.: 2904371

Series: UNO POWER 2-phase DIN rail power supply

Input: 2-phase AC 264–575 V (400V two-phase, NOT single-phase 220V)

Output: 24 V DC, 3.75 A / 90 W, adjustable 24–28 V

Mounting: NS35 DIN rail (EN60715), horizontal installation

Housing width: 55 mm

  1. Clearance Requirements (Mandatory for Heat Dissipation)

Side-by-side horizontal installation: 0 mm minimum clearance (units may be mounted tightly together)

Vertical stacking: Minimum 30 mm upper and lower clearance for cooling air flow

No upside-down or side mounting; only horizontal installation with terminals facing forward/downward

Do not install adjacent to heat-generating components (contactors, braking resistors); high ambient temperature will trigger power derating

Altitude derating: Power rating and insulation voltage must be reduced above 2000 m elevation

  1. DIN Rail Installation & Removal
  2. Hook the top latch onto the NS35 rail first
  3. Press down the unit until the latch clicks securely into place
  4. Removal: Insert a flat screwdriver into the bottom latch tab, pry upward to release the lock and pull the unit off the rail

Vibration resistance: Compliant with industrial cabinet vibration standards; no extra locking screws required once clipped firmly.

  1. Wiring Specifications (M3 Screw Terminals)

Terminal type: Screw clamping terminals

Conductor size: Solid wire 0.2–2.5 mm²; stranded wire 0.2–2.5 mm²; AWG24~AWG14

Strip length: 8 mm

Cable temperature rating: ≥75℃ for ambient <55℃; ≥90℃ for 55~70℃ ambient

Tightening torque: 0.5–0.7 Nm (avoid over-tightening to prevent thread damage)

Terminal Definition (Critical: Two-phase input, no neutral N!)

Input terminals: L1, L2 (two-phase 400V AC, neutral N is not connected); PE protective earth terminal

Output terminals: +24 V, 0 V (24 V DC)

Adjustment potentiometer: ADJ (24~28 V fine-tuning; factory preset to 24 V)

Indicator: DC OK (green light ON = normal output; OFF = no output or protection active)

⚠️ Critical Warning: This is a 2-phase AC power supply. Never wire it as a single-phase L+N unit; incorrect wiring will cause failure or permanent damage.

  1. Wiring Sequence (Lockout-Tagout Safety Procedure)
  2. Confirm upstream circuit is de-energized and apply lockout-tagout
  3. Connect PE protective earth first (reliable earthing is mandatory)
  4. Wire the two-phase input lines L1/L2
  5. Terminate the 24V DC load cables
  6. Inspect for short circuits and earth insulation; confirm no shorted load circuits
  7. Apply power and verify the DC OK green LED illuminates; trim the ADJ potentiometer to set target output voltage
  8. Class 2 (C2LPS) wiring rule: Output cabling shall follow NEC Class 2 specifications; no shared trunking with high-voltage power cables without isolation barriers.
  9. Protection Functions & Fault Diagnosis

Short-circuit protection: Constant current limiting. Class 2 versions feature high sensitivity; short-circuit triggers immediate shutdown, auto-recovery after fault removal.

Overload protection: Current exceeding 105% rated value activates current limiting

Overvoltage protection (OVP): Output shuts down above 35 V DC

Thermal protection: Over-temperature shutdown; auto-restart after cooling down

Undervoltage / phase loss: No start-up if input voltage drops below 264 V AC; DC OK light remains off.

  1. Environmental & Installation Restrictions

Operating temperature: -25℃ ~ +70℃; 2.5%/K power derating above 55℃

Humidity: 5%~95% non-condensing

Forbidden applications: Outdoor direct mounting, dusty/corrosive atmospheres, water splash exposure

Explosion-proof installation (Class I Div.2 T4): Cabinet-only mounting; external wiring must not create ignition sources, comply with flameproof/enclosure standards.

  1. Parallel & Series Connection

❌ This model does NOT support parallel current expansion or series voltage boosting. Select the QUINT series if multi-unit parallel operation is required.

  1. EMC & Earthing

The PE terminal must connect securely to cabinet protective earth; floating earth is prohibited

Upstream overcurrent protection recommendation: C-curve MCB, 1 A or 2 A (for 400V two-phase circuit)

Class 2 output circuits normally do not require additional fuses; if required, implement UL1310 Class 2 current-limiting designs.

  1. Commissioning Checklist

Unit fully clipped onto DIN rail with no play

PE earth connection solid and reliable

L1/L2 two-phase input voltage stays within 264–575 V AC

No short circuit or earth fault on output wiring

DC OK green LED stays steady ON after power-up

Measured output voltage matches the set value

30 mm vertical cooling clearance is maintained top and bottom

III. UNO-PS Full Model List

3.1 UNO-PS / 1AC Single-phase Standard Models (24V Output)

Order No.Full ModelPowerRated Current
2902991UNO-PS/1AC/24DC/30W30 W1.25 A
2902992UNO-PS/1AC/24DC/60W60 W2.5 A
2902993UNO-PS/1AC/24DC/100W100 W4.2 A
1088851UNO-PS/1AC/24DC/100W/H100 W High-altitude version—
2904376UNO-PS/1AC/24DC/150W150 W6.25 A
2904377UNO-PS/1AC/24DC/240W240 W10 A

3.2 Other Output Voltages (12V / 15V / 48V)

Order No.Full ModelOutput Rating
2902998UNO-PS/1AC/12DC/30W12 V / 30 W
2902999UNO-PS/1AC/12DC/55W12 V / 55 W
2902997UNO-PS/1AC/12DC/100W12 V / 100 W
2903000UNO-PS/1AC/15DC/30W15 V / 30 W
2903001UNO-PS/1AC/15DC/55W15 V / 55 W
2903002UNO-PS/1AC/15DC/100W15 V / 100 W
2902995UNO-PS/1AC/48DC/60W48 V / 60 W
2902996UNO-PS/1AC/48DC/100W48 V / 100 W
  1. UNO-PS/2AC Two-phase Standard Models (Non-C2LPS, No Class 2 Explosion Protection)
Order No.Full ModelPower Rating
2904371UNO-PS/2AC/24DC/90W/C2LPS90 W (C2LPS explosion-proof variant, your model)
2904376UNO-PS/2AC/24DC/150W150 W (standard two-phase model)
2904377UNO-PS/2AC/24DC/240W240 W (standard two-phase model)
  1. Model Naming Rule (For Selection Reference)

UNO-PS / 1AC/2AC / 24DC / 90W / C2LPS

  1. 1AC = Single-phase input; 2AC = Two-phase 400V input (L1+L2, no neutral N)
  2. 24DC = 24 V DC output
  3. 90W = Nominal output power
  4. C2LPS = Class 2 output + Class I Division 2 hazardous area certification (only available for the 90W model)
  5. Supplementary Notes
  6. Only two C2LPS explosion-proof models are available:

Single-phase: 2902994

Two-phase: 2904371 (your model). No higher-power two-phase C2LPS variants exist.

  1. No parallel current expansion for the entire UNO series. Use the QUINT series if parallel operation is required.