Schneider BMXDDI3202KH Digital Input Module - Contactor,circuit breaker,sensor,Encoder,PLC,Converter

Wechat: +86-13184948252  WhatsaApp: 0086-13811255435  E-mail:  kent@bestcontactor.com

About    Contact    |    

Schneider BMXDDI3202KH Digital Input Module - Contactor,circuit breaker,sensor,Encoder,PLC,Converter

PLC/

Schneider BMXDDI3202KH Digital Input Module

Series: Modicon X80 (M340 PLC) Model explanation: BMXDDI3202KH = BMXDDI3202K + H; H = Conformal Coating version for harsh environments. Electrical specifications are identical to BMXDDI3202K. Only the PCB is coated with conformal coating for moisture-proof, mould-proof and salt-spray resistance, suitable for ports, chemical plants, underground sites, high-humidity and dusty conditions. ✅ Basic Specifications Type: ...

  • Product Details

Series: Modicon X80 (M340 PLC)

Model explanation: BMXDDI3202KH = BMXDDI3202K + H; H = Conformal Coating version for harsh environments. Electrical specifications are identical to BMXDDI3202K. Only the PCB is coated with conformal coating for moisture-proof, mould-proof and salt-spray resistance, suitable for ports, chemical plants, underground sites, high-humidity and dusty conditions.

✅ Basic Specifications

Type: 32-channel isolated digital input module, Sink (positive logic)

Input voltage: 24VDC, sensor supply range 19~30VDC

Input current per channel: 2.5mA @24V

Logic 1: ≥11V / ≥2mA; Logic 0: ≤5V / ≤0.5mA

Input impedance: 9600Ω

Response time: Typical 4ms, maximum 7ms

Isolation: Channel-to-channel isolation, insulation resistance >10MΩ at 500VDC

Wiring: Compatible with 2-wire / 3-wire proximity switches (IEC61131-2 Type3, IEC60947-5-2). Input parallel connection is not allowed

Connector: Single 40-pin FCN interface, single slot, hot-swap supported

Power consumption: ≤3.9W; Typical backplane 3.3V consumption 121mA

Enclosure protection: IP20

📌 Matching Cables (40-pin FCN)

  1. BMXFCWxxx3: Pre-wired loose cables (3m/5m/10m: BMXFCW303 / BMXFCW503 / BMXFCW1003)
  2. BMXFCCxxx3: Pre-assembled HE10 terminal cables (0.5/1/2/3/5/10m)

🧩 Compatible CPUs

Full Modicon M340 series: BMXP34xx00, BMXP34xx20 (including H versions). General X80 rack, configured via Unity Pro software.

⚖️ Model Comparison

BMXDDI3202K: Standard version, no conformal coating, for conventional control cabinets

BMXDDI3202KH: Conformal coated version for harsh environments. Fully interchangeable in program, pinout and cabling.

📎 Alternative Selection Reference

Same-platform replacement: No drop-in equivalent. For fewer points, refer to BMXDDI1602K(H) (16-point Sink DI).

Domestic replacement: Verify sink logic, isolation and filter time, suitable for domestic PLC remote IO modules.

⚠️ Troubleshooting Tips

  1. No input signal: Check 24V supply, sensor polarity (Sink, signal connects to 0V), broken pins in prefabricated cables.
  2. Flashing / false triggering: Check voltage drop and shielding. This module uses fixed hardware filter; filter parameters cannot be modified by software.
  3. Prefer KH version for humid and corrosive environments; standard K version is prone to PCB corrosion under long-term high humidity.

Schneider Digital Input (DI) Module List by Platform

Note: Suffix H = Conformal coating for harsh environments. X80 platform compatible with M340 / M580; Sink = sinking input, Source = sourcing input; AC = AC input.

  1. Modicon X80 (BMX series, M340 / M580)

DC Digital Input (BMXDDI)

ModelPointsDescription
BMXDDI1602K / BMXDDI1602KH1624VDC, Sink
BMXDDI1603K / BMXDDI1603KH1648VDC, Sink
BMXDDI1604T16125VDC, Sink, wide temperature
BMXDDI3202K / BMXDDI3202KH3224VDC, Sink (the model you enquired)
BMXDDI3203K / BMXDDI3203KH3248VDC, Sink
BMXDDI3232K / BMXDDI3232KH3212/24VDC, Sink/Source configurable
BMXDDI6402K / BMXDDI6402KH6424VDC, Sink

AC Digital Input (BMXDAI)

ModelPointsDescription
BMXDAI08058220VAC
BMXDAI08148100~120VAC
BMXDAI16021624VAC/24VDC, Source
BMXDAI16031648VAC
BMXDAI160416100~120VAC
BMXDAI161416220VAC

X80 Safety DI (Safety PLC dedicated)

ModelPointsDescription
BMXSDI160216Safety digital input, 24VDC
  1. TM3 Series (Expansion for M221/M241/M251/M262 Compact PLC)
ModelPointsDescription
TM3DI8824VDC, screw terminals
TM3DI8G824VDC, spring clamp terminals
TM3DI8A8120VAC
TM3DI161624VDC, screw terminals
TM3DI16G1624VDC, spring clamp terminals
TM3DI16K1624VDC, HE10 connector
TM3DI32K3224VDC, HE10 connector
  1. Advantys STB Distributed Remote IO
ModelPointsDescription
STBDDI37251624VDC Sink
STBDDI3420824VDC Sink
STBDDI3610424VDC Sink
STBDAI02002100~240VAC
STBDAI04004100~240VAC
  1. Supplementary Notes
  2. X80 naming rule: `BMXDDI` = DC DI; `BMXDAI` = AC DI; `K` standard, `KH` conformal coated.
  3. K and KH variants of the same model are fully interchangeable in pinout, programming and backplane interface, only differing in PCB protection.
  4. Mixed I/O modules (DI+DO) such as BMXDDM16022 are excluded from this table.

Application Scenarios of Schneider Digital Input (DI) Modules (X80/STB/TM3, etc.)

Core function of DI modules: Collect binary switch signals, transfer ON/OFF status from external dry contacts, sensors, pushbuttons, limit switches and auxiliary contacts of contactors to PLC. It only detects on/off status and does not process analog signals. The following is sorted by industry and signal type, applicable to BMXDDI3202KH and other X80 modules.

  1. General Signal Acquisition (Used across all industries)
  2. Pushbuttons, selector switches, emergency stop buttons

Local cabinet operation, remote control boxes, E-stop signals (general E-stop; safety E-stop should use dedicated safety DI module BMXSDI1602).

  1. Limit switches, travel switches, proximity switches, photoelectric sensors

Equipment position detection: cylinder confirmation, door switches, baffle limit for material level, object presence detection.

BMXDDI3202KH is 24VDC Sink, compatible with mainstream NPN proximity switches.

  1. Auxiliary contacts of contactors / relays, circuit breaker status feedback

Motor running feedback, VFD ready feedback, circuit breaker open/close status, thermal relay fault signals.

  1. Dry contact signals

Fire alarm systems, access control, damper/valve position feedback in HVAC, float level switches.

  1. HVAC

Running / fault feedback of fans and water pumps

Differential pressure switches, frost protection switches, air damper / water valve end-position feedback

Filter differential pressure alarm, high/low float level switches

Feedback of smoke exhaust dampers and fire dampers

Conformal coated KH versions (BMXDDIxxxxKH) are preferred for humid and dusty machine rooms.

  1. Water Treatment, Water Supply & Drainage, Wastewater Plants

Level switches (high level, low level, overflow)

Pump run, fault, hand-auto status

Limit signals for bar screens and sludge scrapers

Pulse signals from flow meters (high-speed pulses require dedicated high-speed counter modules; standard DI is not suitable for high-frequency pulses)

Valve open / closed position feedback

KH coated modules are widely used in corrosive, high-humidity wastewater sites.

  1. Packaging, Assembly Lines & Automated Production Lines

Photoelectric detection for material presence / missing material

Cylinder and clamp confirmation signals

Conveyor belt jam and deviation switches

Barcode detection, silo level switches

Safety gate and guard door status signals

BMXDDI6402K (64-point DI) is commonly used for high-point-count lines to save slots.

  1. Crane Systems, Conveying & Warehouse Logistics

Crane travel limits, upper/lower hard limits, buffer switches

Pallet in-position, bay detection

Roller conveyor deviation and E-stop loop feedback

Roller shutter and guard door status

  1. Power Distribution Rooms & Energy Monitoring

Circuit breaker and disconnector open/close position feedback for high-voltage cabinets

Cabinet door interlock, earthing switch status

Transformer thermostat switches, cooling fan feedback

DC panel fault alarm dry contacts

BMXDAI AC DI modules are often used for 220VAC cabinet signals.

  1. Oil & Gas, Chemical Industry, Ports (Harsh Environments)

Valve position feedback, pump status, dry contact output of combustible gas detectors

Limit switches and door interlocks for trestle and quay equipment

Salt spray, high humidity and condensation → select KH conformal coated versions (BMXDDI3202KH etc.). Standard K versions are vulnerable to corrosion.

  1. Building Automation, Fire Protection & Pumping Stations

Dry contact alarms from fire host, sprinkler pressure switches

Elevator interlock signals, smoke exhaust fan status

Rainwater pumps, sump tank level monitoring

✅ Quick Selection Guide by Scenario

Normal indoor control cabinet, dry environment: BMXDDIxxxK

Chemical / port / high humidity & salt spray: BMXDDIxxxKH (conformal coating)

220VAC contact signals: BMXDAI AC DI

Safety circuits, safety gates, safety E-stop: BMXSDI safety DI

Small machines, low I/O count: TM3DI series

Distributed remote IO with scattered field points: STB Advantys remote DI

⚠️ Scope Limitations (What DI modules cannot do)

  1. Cannot directly measure 4-20mA or temperature (AI analog modules required)
  2. Standard DI is not suitable for high-frequency pulse counting (high-speed counter module required)
  3. Safety functions shall not be implemented via ordinary DI; dedicated safety DI modules are mandatory.

Prev:

Next:

Leave a Reply

Leave a message