Siemens 6ES7136-6BA00-0CA0 Fail-Safe Digital Input Module - Contactor,circuit breaker,sensor,Encoder,PLC,Converter

PLC/

Siemens 6ES7136-6BA00-0CA0 Fail-Safe Digital Input Module

Full Name: SIMATIC DP ET200SP Fail-Safe Electronic Module F-DI 8×24VDC HF Direct Replacement Model: 6ES7136-6BA01-0CA0 (Factory upgraded version; the old model entered the phase-out stage starting Oct 1, 2024) ✅ Model Code Explanation 6ES7: SIMATIC S7 automation electronic module 136: ET200SP fail-safe F-I/O series 6BA00: F-DI 8-channel 24VDC high function (HF) 0CA0: ET200SP electronic module ...

  • Product Details

Full Name: SIMATIC DP ET200SP Fail-Safe Electronic Module F-DI 8×24VDC HF

Direct Replacement Model: 6ES7136-6BA01-0CA0 (Factory upgraded version; the old model entered the phase-out stage starting Oct 1, 2024)

✅ Model Code Explanation

6ES7: SIMATIC S7 automation electronic module

136: ET200SP fail-safe F-I/O series

6BA00: F-DI 8-channel 24VDC high function (HF)

0CA0: ET200SP electronic module version

📌 Key Specifications

Channels: 8 fail-safe digital inputs + 8 built-in sensor supply VS

Rated Voltage: DC24V, allowable range 19.2~28.8V, reverse polarity protection

Safety Rating: SIL3 (IEC61508), PLe / Cat.4 (ISO13849-1)

Input Type: Sinking input (P-reading), supports 3-wire / 4-wire safety sensors (E-stop, safety gate, safety light curtain, etc.)

Channel Delay: Independently configurable per channel from 0.4ms to 20ms

Width: 15 mm; Dimensions: 73(H) × 58(D) mm

Compatible BaseUnit: Type A0 BaseUnit, color marking CC01

Evaluation Modes: 1oo1 (single-channel), 1oo2 (dual-channel comparison detection)

Diagnostics: Channel-level short-circuit and wire-break diagnosis; configurable single-channel deactivation / module-wide deactivation

Firmware: V3.0, firmware upgrade supported; I&M0~I&M3 information supported

Programming Environment: TIA Portal V12+, SIMATIC Safety; STEP7 V5.5 SP3+

⚙️ Terminal Assignment (16-pin)

1:DI0|2:DI1|3:DI2|4:DI3|5:DI4|6:DI5|7:DI6|8:DI7

9:VS0|10:VS1|11:VS2|12:VS3|13:VS4|14:VS5|15:VS6|16:VS7

VSn = Module-integrated short-circuit protected 24V sensor supply; external 24V supply is also acceptable

🧩 Typical Application Scenarios

ET200SP distributed safety station, connected to F-CPU (F-1511C / F-1512C / F-1516F, etc.):

Emergency stop pushbuttons (E-STOP)

Safety gate switches, safety hinge switches

Safety light curtains, safety laser scanner signal acquisition

Safety limit switches, safety foot switches

⚠️ Upgrade & Compatibility Notes

  1. 6ES7136-6BA00-0CA0: PM400 obsolescence notice, phased supply reduction from Oct 1, 2024. New projects are recommended to select 6ES7136-6BA01-0CA0
  2. 6BA01 is pin-to-pin, terminal, dimension and program compatible for direct replacement; firmware and diagnostic details optimized. BaseUnit and user program remain unchanged for drop-in replacement
  3. F-CPU + Safety program package is mandatory; standard non-safety CPUs cannot recognize F-modules

📎 Common Bill of Supporting Materials

BaseUnit: 6ES7193-6BP00-0BA0 (A0 BU, light-colored base unit)

Color marking label: CC01

Front connector: ET200SP 16-pin straight plug terminal

📋 Troubleshooting Guide

DIAG red light: Module fault / F-communication fault / deactivation; DIAG green light: Module normal

Channel red light: Wire break, short-circuit, mismatch error under 1oo2 mode

Deactivation reset: Acknowledge (F-Ack) inside safety program or adjust deactivation parameter strategy

Common pitfalls: Do not short two signal wires in 1oo2 wiring; do not overload VS supply

6ES7136-6BA00-0CA0|ET200SP F-DI 8×24VDC HF Application Scenarios

Positioning: PROFIsafe distributed fail-safe digital input module, SIL3 / Cat.4 / PLe. Used with S7-1500F safety CPU. ET200SP remote station collects safety switch signals locally, replacing traditional safety relay circuits

  1. By Safety Signal Type (Most Common)
  2. E-Stop Pushbutton

Dual-channel 1oo2 wiring with normally closed dual contacts of E-stop. Wire break, short-circuit and contact mismatch can be diagnosed. Safety rating reaches PLe/SIL3. Widely used in robot cells, presses and conveyor lines.

  1. Safety Gate / Safety Hinge Switch

Guard door interlock with dual-contact safety gate switch under 1oo2 evaluation. Door opening triggers safe stop. Supports zone safety interlock for welding cells, protective enclosures and equipment access doors.

  1. Safety Light Curtain, Safety Laser Scanner, Safety Photoelectric

Collect OSSD safety output signals from light curtains. The built-in VS sensor supply can power the light curtain directly. Single-channel or dual-channel mode optional. Applied in packaging machines, stamping equipment and robot access protection.

  1. Safety Mat, Safety Edge

Pressure-sensitive safety sensors to detect personnel entering hazardous zones, mainly for peripheral protection of robot workcells.

  1. Two-Hand Control Device

Synchronization signal acquisition for two-hand operation to prevent accidental triggering, used for high-risk equipment such as presses, injection molding machines and punch presses.

  1. Safety Limit Switch, Travel Safety Switch

Axis hard limit and guard limit, distinguishing safety limits from ordinary limits. For large machine tools and gantry equipment.

  1. Rope Pull Emergency Stop Switch (Conveyor Line Pull Switch)

Long-distance line-side E-stop for belt conveyors and stacker cranes. Channel-level wire-break diagnosis suits long cable field installation.

  1. Industry & Machine Application

Automotive Automation: Welding stations, robot welding cells, final assembly conveyor lines, fixture stations

Multiple distributed ET200SP remote stations. Each station installs this module locally to manage its own safety signals and implement zone shutdown without affecting the whole line.

Machine Tool Industry: CNC machining centers, gantry milling machines, grinders

Spindle guard doors, slideway protective doors, safety hard limits. Supports long shielded cables (max. 1000m), fast response starting from 0.4ms input delay.

Packaging & Food & Beverage: Filling machines, palletizers, sleeve labeling machines, case erectors

Hopper access doors, safety light curtains, guard interlock. Meets CE Machinery Directive, suitable for hygienic machinery safety systems without separate safety relay cabinets.

Material Handling & Conveying: Belt lines, sorting lines, AS/RS stacker cranes

Line-side rope pull switches, access doors, safety guard switches, safety deviation signals.

Pharmaceutical Equipment: Filling, tableting and cleaning machines

SIL3-compliant safety signal acquisition, supports validation documentation and traceable safety diagnostics.

Rubber & Plastics, Injection Molding, Die Casting: Injection molding machines, die casting cells

Safety gates, two-hand buttons, safety light curtains for high-temperature molten material zone protection.

  1. Architecture & Usage Notes for Selection

1oo1 (Single-channel): Suitable for PLd / SIL2 applications with one signal per DI channel.

1oo2 (Dual-channel comparison): Cat.4 / PLe / SIL3. Fixed pairing: DI0&DI4, DI1&DI5, DI2&DI6, DI3&DI7 for cross-checking to detect short-circuits, wire breaks and contact discrepancies. This is the primary usage mode.

8 independent short-circuit protected VS sensor power supplies onboard. Can power safety sensors directly to reduce external 24V safety wiring; external power supply is also available.

Communication: PROFINET + PROFIsafe, mounted on ET200SP IM interface module. F-CPU + Safety package required; standard CPU cannot recognize F-modules.

Installation: Distributed near machine equipment to reduce heavy safety cable runs from control cabinets to field sensors, easier maintenance and zone diagnosis.

  1. Unsuitable Applications

Analog safety signals (select F-AI 6ES7136-6AAxx series)

Safety output (F-DQ, 6ES7136-6DB00 / 6DC00)

Intrinsically safe signals for explosion-proof zones

Ordinary non-safety digital input only (Standard ET200SP DI modules for lower cost)

6ES7136-6BA00-0CA0|Complete Installation & Wiring Instructions

Compatible BaseUnit: A0 light-colored base 6ES7193-6BP00-0BA0, color marking CC01. F-CPU + PROFIsafe mandatory; standard CPU not supported

Terminal Definition (16-pin BaseUnit)

1:DI0|2:DI1|3:DI2|4:DI3|5:DI4|6:DI5|7:DI6|8:DI7

9:VS0|10:VS1|11:VS2|12:VS3|13:VS4|14:VS5|15:VS6|16:VS7

VSn = Channel-wise short-circuit protected 24V sensor supply (integrated inside module)

✅ Fixed 1oo2 Pairing (Mandatory for SIL3/PLe/Cat.4)

Channel pairs: DI0&DI4; DI1&DI5; DI2&DI6; DI3&DI7

Only the first channel (DI0/DI1/DI2/DI3) is used for address assignment in configuration; the second channel is for cross-comparison check

  1. Mechanical Installation Steps (Standard ET200SP Workflow)
  2. Rail: 35mm standard DIN rail with reliable earthing. Horizontal installation preferred: 0~60℃; vertical installation: 0~50℃
  3. Station sequence: ET200SP IM interface module at the far left, then BaseUnits in sequence. The first BaseUnit must be type A0 light-colored, dark B0 cannot start the station
  4. Mount BaseUnit: Snap onto DIN rail and lock rightward. BaseUnits connect end to end; internal spring contacts automatically connect the backplane bus. F-modules can only use A0 BU
  5. Wiring prep: Pull the 16-pin front connector out of the BaseUnit before crimping wires, avoid live plugging of terminals
  6. After crimping, reinsert the front connector into BaseUnit → Clip the F-DI electronic module from top until audible click
  7. Attach CC01 color label to prevent mixing with other BaseUnit types
  8. Earthing: Shield of control cabinet and signal cables single-point grounded. Safety cables recommended shielded, routed separately from power cables

Protection Class: IP20, cabinet installation only, not for outdoor exposure

  1. Power Supply Options

Option A: Use built-in VS supply (Recommended for safety sensors, E-stop, safety gates)

Each VSn provides independent 24V+ with short-circuit diagnosis. One VS only supplies its matched sensor group

Example: VS0 powers the sensor group for DI0/DI4; VS1 powers DI1/DI5 group, and so on

Advantage: Short-circuit only triggers fault alarm for that individual channel without affecting other safety channels; wire break and short-circuit of supply circuit can be diagnosed

Option B: External 24V supply for sensors (Active OSSD light curtain, laser scanner)

VS terminals unused. Only two OSSD signal wires connect to DI channels. 0V of external 24V must be equipotential with PLC system M to avoid false alarms caused by potential difference

Module operating power: Supplied from L+/M bus of A0 BaseUnit, fed by power supply at IM side

  1. Three Typical Wiring Schemes

① 1oo2 Dual-channel Wiring (Dry-contact E-stop / Safety Gate, SIL3/PLe)

Take DI0+DI4 pair as example (most widely used)

  1. VS0 (Pin9) → Contact 1 of safety switch
  2. Output of safety switch contact1 → DI0 (Pin1)
  3. VS4 (Pin13) → Contact 2 of safety switch
  4. Output of safety switch contact2 → DI4 (Pin5)
  5. Common 0V of switch connected to system 24V M

Important: Never short the two contact signals! Module continuously compares DI0 and DI4 level; mismatch triggers deactivation and fault alarm. Normally closed dual contacts are standard for E-stop to meet safety requirements.

② 1oo2 Active OSSD (Safety Light Curtain, Laser Scanner)

Two OSSD outputs from light curtain are active 24V signals, no VS supply required

  1. OSSD1 → DI0 (Pin1)
  2. OSSD2 → DI4 (Pin5)
  3. Light curtain powered by external 24V, 0V tied to PLC M

Configuration: 1oo2 evaluation mode to verify synchronous status of two OSSD signals

③ 1oo1 Single-channel (Only PLd / SIL2, NOT for E-stop or safety gates)

One DI channel for one sensor, powered by corresponding VSn

Example: VS0 → Sensor +, sensor signal → DI0; DI4 unused. Configure 1oo1 mode in hardware

Warning: 1oo1 cannot achieve PLe / Cat.4, forbidden for high-risk workstations

  1. TIA Portal Configuration Points After Wiring
  2. Select 6ES7136-6BA00-0CA0 in hardware configuration, assign PROFIsafe target address (F-address)
  3. Select channel evaluation mode: 1oo1 / 1oo2. 1oo2 must strictly follow pairing rule 0&4, 1&5, 2&6, 3&7
  4. Channel delay: 0.4~20ms configurable for chatter suppression; 0.4~2ms typical for E-stop
  5. Deactivation setting: Single-channel deactivation / full module deactivation; define deactivation reset method (F-Ack inside safety program)
  6. Download hardware configuration and safety program, complete F-signature validation, confirm PROFIsafe communication fault-free online
  7. Online test: Actuate safety sensor and observe channel LEDs. Mismatch in 1oo2 triggers DIAG red light and channel F red light
  8. LED Indicator Description

PWR green: Module power supply OK

DIAG: Green = Normal; Red = F comms fault / deactivation / module failure

CHx green: Channel logic ON (signal=1)

Fx red: Wire break, short-circuit, dual-channel mismatch, supply fault on this channel

  1. Critical Rules & Field Pitfalls
  2. Do not short DI0 and DI4 under 1oo2 mode, this will trigger immediate fault
  3. VS cannot be cross-channel paralleled (e.g. VS0 cannot power DI0 and DI1 sensors together, independent short-circuit diagnosis will be lost)
  4. Separate routing for safety cables and power cables to avoid interference and unintended deactivation
  5. Equipotential bonding: All safety sensor 0V must share the same M potential with PLC. Floating ground causes random false alarms
  6. Never hot-swap module or front connector. Cut off safety circuit power before wiring
  7. The module diagnoses wire break and short-circuit, but the field cables must be safety-certified cables
  8. Commissioning Sequence

Power off & wire → Check continuity and no short-circuit → Power on → Download hardware + safety program in TIA → Establish PROFIsafe communication → Test each safety sensor → Trigger deactivation and test reset function → Safety acceptance

SIMATIC S7 6ES7 Automation Electronic Module List (Grouped by Series, including ET200SP F-modules you queried)

Prefix rule: 6ES7 = SIMATIC S7 electronic module

Suffix grade identifier: BA=Basic / ST=Standard / HF=High Function / HS=High Speed / F=Fail-safe (PROFIsafe)

  1. ET200SP Distributed I/O Modules (6ES713x, your primary series)

Digital Input DI

Order No.Description
6ES7131-6BH01-0BA0DI 16×24VDC ST
6ES7131-6BF00-0BA0DI 8×24VDC ST
6ES7131-6BH00-0BA0DI 16×24VDC HF
6ES7131-6FD00-0BB1DI 4×120..230VAC ST

Digital Output DQ

Order No.Description
6ES7132-6BH01-0BA0DQ 16×24VDC 0.5A ST
6ES7132-6BF00-0BA0DQ 8×24VDC 0.5A ST
6ES7132-6BD20-0BA0DQ 4×24VDC 2A HF
6ES7132-6HD00-0BB1DQ 4×120..230VAC 2A ST

Analog Input AI

Order No.Description
6ES7134-6HD01-0BA1AI 4×U/I ST
6ES7134-6GF00-0AA1AI 8×U/I HF
6ES7134-6JD00-0DA1AI 4×TC Thermocouple HS
6ES7134-6PA00-0CU0AI Energy Measurement Module
6ES7134-6JF00-0CA1AI 4×RTD Resistance Temperature Detector

Analog Output AQ

Order No.Description
6ES7135-6HD00-0BA1AQ 4×U/I ST
6ES7135-6FB00-0BA1AQ 2×U/I HF

✅ Fail-Safe F-Modules (PROFIsafe, your target model)

Order No.Description
6ES7136-6BA00-0CA0F-DI 8×24VDC HF (Old version, replaced by 6BA01)
6ES7136-6BA01-0CA0F-DI 8×24VDC HF (Upgraded direct replacement)
6ES7136-6DB00-0CA0F-DQ 4×24VDC 2A PPM
6ES7136-6DC00-0CA0F-DQ 8×24VDC 0.5A
6ES7136-6AA00-0CA0F-AI 4×I 0/4-20mA

ET200SP BaseUnit BU

Order No.Description
6ES7193-6BP00-0BA0A0 Light-colored BU (For F-modules, CC01 marking)
6ES7193-6BP00-0DA0B0 Dark-colored BU
  1. S7-1500 / ET200MP Signal Modules (6ES753x)

Digital

6ES7521-1BL00-0AB0: DI 32×24VDC HF

6ES7521-1BH00-0AB0: DI 16×24VDC HF

6ES7522-1BL01-0AB0: DQ 32×24VDC 0.5A HF

6ES7522-1BH01-0AB0: DQ 16×24VDC 0.5A HF

Analog

6ES7531-7NF00-0AB0: AI 8×U/I HF

6ES7531-7KF00-0AB0: AI 8×U/I/RTD/TC ST

6ES7532-5HD00-0AB0: AQ 4×U/I ST

6ES7532-5NB00-0AB0: AQ 2×U/I ST

6ES7536-1MF00-0AB0: F-AI 8×I 4-20mA Safety Analog Input

  1. S7-1200 Signal Modules SM (6ES722x / 6ES723x)

Digital

6ES7221-1BF32-0XB0: SM1221 DI 8×24VDC

6ES7221-1BH32-0XB0: SM1221 DI 16×24VDC

6ES7222-1BF32-0XB0: SM1222 DQ 8×24VDC Transistor

6ES7222-1BH32-0XB0: SM1222 DQ 16×24VDC Transistor

6ES7223-1BL32-0XB0: SM1223 16DI/16DQ

Analog

6ES7231-4HD32-0XB0: SM1231 AI 4×U/I

6ES7231-5ND32-0XB0: SM1231 AI 8×U/I

6ES7232-4HD32-0XB0: SM1232 AQ 4×U/I

6ES7234-4HE32-0XB0: SM1234 AI4/AQ2

  1. S7-200 SMART EM Expansion Modules (6ES7288)

6ES7288-2DE16-0AA1: EM DE16 16DI

6ES7288-2QT16-0AA1: EM QT16 16DQ Transistor

6ES7288-3AE04-0AA1: EM AE04 4AI

6ES7288-3AR04-0AA1: EM AR04 4RTD

6ES7288-3AT08-0AA1: EM AT08 8TC

  1. IM Interface Modules (ET200SP / MP Communication Base)

6ES7155-6AA01-0BN0: IM155-6 PN ST ET200SP PROFINET Interface

6ES7155-6BA00-0CN0: IM155-6 DP ST ET200SP PROFIBUS Interface

6ES7545-5DA00-0AB0: IM155-5 PN ET200MP

  1. Model Encoding Decoding Guide

6ES7 136 6BA00 0CA0

  1. 6ES7: SIMATIC S7 electronic module
  2. 136: ET200SP fail-safe F-I/O
  3. 6BA00: F-DI 8×24VDC HF
  4. 0CA0: Version and compatible BaseUnit type

Series segment identification:

13x = ET200SP I/O

52x/53x = S7-1500 / ET200MP I/O

22x/23x = S7-1200 SM signal module

288 = S7-200 SMART EM module

Prev: