Brand: Telemecanique Sensors, OsiSense XS1 Series, M18 flush-mount inductive sensor
Model Code Explanation
XS1 18 B3 P A M12
XS1: XS1 general-purpose inductive sensor series
18: Thread size M18×1
B3: Flush-shielded type, nominal sensing distance Sn = 8 mm
P: PNP output
A: Normally-Open (NO)
M12: M12-4-pin male connector
Core Technical Specifications
| Item | Specification |
| Sensing Distance | Sn = 8 mm (flush mounting) |
| Power Supply | 12‑24 VDC, reverse‑polarity protection |
| Output | 3‑wire PNP‑NO (Normally Open) |
| Max Load Current | ≤200 mA, short‑circuit & overload protection |
| Switching Frequency | 1000 Hz |
| Housing | Nickel‑plated brass; Sensing face: PPS plastic |
| Mechanical Dimension | M18×1, overall length 50 mm, 2 lock nuts included |
| Ingress Protection | IP65 / IP67 / IP69K |
| Operating Temperature | -25℃~+70℃ |
| Electrical Interface | M12‑4‑pin male plug |
| Status Indicator | Yellow LED output indicator |
| Target Material | Metals (optimal for ferrous steel) |
Pin Assignment (M12-4-pin Male Connector)
1-Brown: DC + Power
2-Black: PNP Signal Output
3-Blue: 0V / GND
4-Not connected
Application
Position detection of metal objects on machine tools, conveyor lines, packaging machinery and mobile equipment. Suitable for wash-down conditions (IP69K).
Interchangeable Models within the Same Series
- XS118B3NAM12: NPN-NO, rest parameters identical
- XS118B3PCM12: PNP NO+NC, 4-wire output
- XS118B3PBL2: PNP-NO, 2 m fixed cable version
Key Points for Domestic-made Replacement
M18 flush-mount, sensing distance 8 mm, PNP-NO, M12 connector, 12-24 VDC, 200 mA
Must select shielded-flush type; do NOT use non-flush variant (Sn 12 mm) by mistake.
Core Advantages of Telemecanique XS-Series Inductive Proximity Sensors
Applicable to XS118B3PAM12 (XS1-series M18 flush-mount model) shown above.
- High Electrical Reliability, Low Field Failure Rate
- Comprehensive built-in protection: Integrated short-circuit, overload and reverse-polarity protection. Tolerates wiring mistakes and load short-circuits without easy burnout, offering high on-site fault tolerance for industrial environments.
- Stable output: Small differential hysteresis (1-15 % Sn), low signal jitter. No false triggering on high-speed stations; switching frequency up to 2000 Hz for high-cycle machinery.
- Wide voltage tolerance: DC versions accept 12-24 V DC; withstands transient surges up to 36 V for plants with unstable power supplies.
- Fully resin-potted solid-state circuitry, no mechanical contacts. Unlimited mechanical service life for continuous long-term operation.
- Robust Mechanical & Protection Performance for Harsh Conditions
- Standard nickel-plated brass housing; premium versions in stainless steel. PPS sensing face resists impact, cutting fluid, oil and emulsion corrosion.
- Ingress rating IP67 / IP68 / IP69K, withstands high-pressure wash-down for food-processing and machine-tool environments. Complies with IEC vibration and shock standards; stable under heavy machine vibration.
- Broad operating-temperature range:-25℃~+70℃ standard; special variants up to +85 ℃ for cold-store and hot-workshop applications.
- Full lineup of flush / non-flush options. Flush-shielded units can be fully embedded into metal fixtures without false triggering, offering high installation flexibility (XS118B3PAM12 is flush-mount).
- Excellent Anti-Interference Performance (Critical for Industrial Sites)
-Optimized internal oscillator circuit. Lower false-signal probability vs ordinary domestic sensors in strong-EMI areas near inverters and servo drives; reliable performance on machine-tools and welding stations.
-Consistent sensing distance across units; minimal part-to-part Sn deviation. No repeated adjustment required during mass-equipment commissioning.
- Comprehensive Portfolio for Easy Selection & Spare-parts Management
- Full range of sizes: M8/M12/M18/M30 cylindrical, square-flat, micro sizes. Flush / non-flush; PNP / NPN; NO / NC; cable-out / M12 connector; AC-DC 2-wire; IO-Link intelligent variants available.
- Standardized part-number coding. Complete parameters can be interpreted directly from model codes such as XS118B3PAM12, simplifying selection, replacement and spare-part handling.
- Global approvals: CE, UL, CSA, CCC; ready-to-use for export-oriented machinery.
- Large installed base; complete drawings, datasheets and CAD resources. Mature distributor network for easy spare-part procurement.
- Convenient Operation & Maintenance
- Clear yellow-LED status indicator for fast on-site diagnostics.
- M12-connector versions enable fast field replacement without cable stripping and crimping, minimizing downtime.
- Non-contact detection; zero mechanical wear, no contact-burn-out failure mode.
Objective Limitations vs Competitors
- Higher purchase cost than general domestic proximity sensors.
- Lead-time fluctuations for some legacy part numbers.
- Reduced sensing distance for non-ferrous metals (Al, Cu). This is inherent to inductive-sensor principle, not brand-specific defect.
Typical Application Fields
Machine tools, conveyor systems, packaging machinery, automotive tooling, food-processing wash-down equipment, welding stations, heavily-vibrated automation equipment.
Practical Application Cases of Telemecanique XS-Series Inductive Proximity Sensors
Cases cover XS118B3PAM12 (M18 flush-mount, Sn 8 mm, PNP-NO, M12 connector). Each includes working condition, solution and model recommendation.
Case 1: CNC Machine Tool — Fixture & Pallet-In-Position Detection
Working Condition: Machine-tool interior with cutting fluid, emulsion and oil; heavy vibration and strong EMI from servo / inverter systems. Detect whether fixtures and pallets are properly seated to prevent empty cuts and machine collision.
Solution: XS118B3PAM12 flush-mounted into fixture base to sense metal work-holding jigs. PNP signal sent to PLC; machining cycle only permitted after valid fixture detection.
Selection Justification: IP67/IP69K wash-down resistance; built-in reverse-polarity / short-circuit protection; vibration resistance; flush-shield design prevents false triggering against surrounding metal; yellow-LED visual status feedback.
Alternative: XS112B3PAM12 (M12) for compact-space installation.
Case 2: Conveyor & Sorting Line — Work-piece Arrival & Stopper-Cylinder Position Feedback
Working Condition: Factory conveyor with dust and oil contamination, continuous cyclic operation. Detect metal-work-piece arrival and extend-retract status of stopper cylinders for part-blocking, diverting and counting functions.
Solution: XS118B3PAM12 mounted on machine frame to sense cylinder piston rods and metal work-piece brackets. M12 quick-connector simplifies maintenance change-outs without re-crimping cables.
Selection Justification: 1 kHz switching frequency matches medium-cycle conveyors; wear-resistant nickel-plated brass housing; low signal jitter ensures reliable counting; unified part number for fleet-wide spare-part management.
Case 3: Automotive Component Tooling — Assembly-Station Presence Confirmation
Working Condition: Automotive-assembly tooling with occasional welding spatter and high vibration. Verify correct loading of metal components to avoid missing-part or mis-loading faults.
Solution: XS1-series M18 flush-mount sensors distributed across tooling. Next clamping action enabled only after all presence signals are confirmed. Upgrade to XS4 weld-field Factor 1 models for heavy-spatter zones (constant sensing distance for all metal types, anti-spatter performance).
Selection Justification: Low hysteresis, high detection consistency; immunity to welding-equipment EMI; CE/UL approvals for export machinery.
Case 4: Packaging Machinery — Filling & Cartoning Mechanism Position Sensing
Working Condition: Packaging lines with wash-down cleaning cycles and humid environment. Detect position of mechanical stops, cams and cylinders to sequence filling and cartoning actions.
Solution: XS118B3PAM12 for standard stations. Stainless-steel-housed XS variants for food-grade high-pressure wash-down (IP69K).
Selection Justification:-25~+70 ℃ operating range; fast-swap M12 connector; comprehensive electrical protection prevents sensor burnout from field wiring errors.
Case 5: Press-Equipment — Mold-Protection & Ejection-Confirmation
Working Condition: Press-shop environment with heavy shock-vibration and oil contamination. Confirm correct work-piece ejection; inhibit mold closing if no part detected for mold-damage prevention.
Solution: Long-range XS5-M30 series (Sn ≥ 15 mm) to compensate for mold wear and positional offset. XS118B3PAM12 NOT recommended; prioritize long-distance M30 sensors for press applications.
Selection Justification: High shock-vibration tolerance; generous installation tolerance; short-circuit / overload protection for fluctuating shop power.
Case 6: Robot Work-cell — Gripper-Part-Presence & Mechanical-Limit Detection
Working Condition: Robot end-effector with compact layout and reciprocating motion. Verify metal-part gripping status and mechanical hard-stop positions.
Solution: XS2-M12 for compact grippers; XS118B3PAM12 for larger targets. IO-Link capable XSA-series for high-end stations to access sensor diagnostic data.
Selection Justification: Fully-potted shock-resistant construction; non-contact wear-free operation; M12 plug compatible with robot-cable-chain routing.
Case 7: Lifting & Construction Machinery — Mobile-Equipment Limit-Position Detection
Working Condition: Lifts, hoists and construction machinery with wide temperature swing, heavy vibration, outdoor dust and rain exposure. Detect limit positions of booms and sliders for over-travel alarm.
Solution: XS1-series cylindrical proximity sensors (wide-voltage capable variants) for limit-alarm duties.
Selection Justification: Wide temperature range; high shock resistance; IP67 for outdoor harsh-environment deployment.
Quick-Reference Selection Table
| Application | Recommended Model | Suitability for XS118B3PAM12 |
| Machine‑tool fixture, general conveyor | XS118B3PAM12 | ✅ Preferred |
| Space‑constrained mounting | XS112B3PAM12(M12) | ❌ Oversized |
| Welding‑spatter station | XS4‑M18 weld‑resistant type | ❌ Standard model not spatter‑proof |
| Press‑mold protection | XS5‑M30 long‑range | ❌ Insufficient sensing distance |
| Food‑grade high‑pressure wash‑down | XS stainless‑steel housing version | ⚠️ Nickel‑plated‑brass housing not food‑safe |
Technical Specifications of Telemecanique XS-Series Inductive Proximity Sensors
Three sections: Full specifications of XS118B3PAM12; general electrical-mechanical specs for XS family; comparison of main sub-series.
- Full Specifications of XS118B3PAM12 (M18 Flush-mount, PNP-NO, M12 Connector)
| Parameter Item | Value |
| Product Series | XS1 General‑Purpose Inductive Proximity Sensor |
| Detection Principle | Inductive eddy‑current effect, metal‑only detection |
| Mounting Style | Flush‑shielded (Flush) |
| Thread Size | M18×1 |
| Nominal Sensing Distance Sn | 8 mm (standard steel target) |
| Supply Voltage | 12‑24 VDC; absolute limit 10‑36 VDC; reverse‑polarity protection |
| Output Type | 3‑wire DC, PNP‑NO Normally Open |
| Max Load Current | ≤200 mA; built‑in short‑circuit & overload protection |
| Switching Frequency | 1000 Hz |
| Hysteresis | 1‑15 % Sr of nominal distance |
| Overall Length | 50 mm, 2 lock nuts supplied |
| Housing Material | Nickel‑plated brass; Sensing face: PPS plastic |
| Electrical Interface | M12‑4‑pin male connector |
| Pin Definition | 1‑Brown: DC+ ; 2‑Black: Signal ; 3‑Blue: 0V ; 4‑No connection |
| Status Indicator | Yellow LED output indicator |
| Ingress Protection | IP65, IP67 |
| Operating Temperature | -25℃~+70℃ |
| Vibration Resistance | 10‑55 Hz, ±2 mm amplitude IEC60068‑2‑6 |
| Shock Resistance | 50 g, 11 ms IEC60068‑2‑27 |
| Approvals | CE, UL, CSA |
| Target‑Material Attenuation | Reduced range for Aluminium / Copper (inherent inductive‑sensor characteristic) |
- General Technical Specifications for XS-Series Inductive Sensors
Electrical Specifications
- Power Supply
-3-wire DC: 12-24 VDC, absolute limit 10-36 VDC. Reverse-polarity, short-circuit and overload protection standard.
-2-wire AC-DC: 24-240 VAC / 24-210 VDC
- Output Types: PNP, NPN; NO / NC / NO+NC; IO-Link intelligent; Analog 0-10 V / 4-20 mA
- Output Current: Max 200 mA for DC transistor types; Max 300 mA for 2-wire AC types
- Switching Frequency: M8 up to 5 kHz; M12 approx 2 kHz; M18 approx 1 kHz; M30 approx 500 Hz; AC-2-wire ≤ 25 Hz
- Hysteresis: Typical 1-15 % Sn; Repeat accuracy ≤ 1 % Sn
Mechanical & Environmental Specifications
- Body Styles: Cylindrical M8, M12, M18, M30; square, flat, micro Φ4-M5; flush-mount / non-flush-mount versions.
- Housing Materials: Nickel-plated brass, 303/316L stainless steel, PPS plastic.
- Connection Options: 2 m fixed cable; M8/M12 male / female connector.
- Ingress Protection: IP67 baseline; selected models IP68, IP69K for high-pressure wash-down.
- Operating Temperature:-25℃~+70 ℃ standard; high-temperature variants up to 85 ℃.
- Certifications: CE, UL, CSA, CCC; SIL2 safety-rated options available.
- Comparison Table of Main Sub-series
| Series | Positioning | Typical Sn Sensing Distance | Housing Material | Protection | Key Features |
| XS1 | General‑purpose Economy | 2‑15 mm | Nickel‑plated brass | IP67/IP69K | Machine‑tool & conveyor‑line use; comprehensive model offering (XS118B3PAM12 belongs here) |
| XS2 | High‑Performance Extended‑Range | M12:7‑8 mm ; M18:12 mm | Brass / Stainless Steel | IP67‑IP69K | Non‑flush long‑range, enhanced noise immunity |
| XS4 | Weld‑Field Factor 1 | 5‑15 mm | Brass/PPS | IP68 | Constant range across all metal types, anti‑weld‑spatter; automotive‑welding‑cell application |
| XS5 | Extra‑Long‑Range | M30 up to 22 mm | Brass | IP67 | Large installation tolerance, stamping‑tooling application |
| XSA | IO‑Link Intelligent | 4‑15 mm | Brass | IP67 | Remote parameter setup, temperature diagnosis, counter function; smart‑manufacturing deployment |
| XS6 | Square‑Body Proximity | 5‑20 mm | Plastic / Metal | IP67 | For confined mounting space; SIL2 safety‑rated options |
- Critical Selection Guidelines
- Flush Mount: Sensor may be fully embedded into metal fixture without false triggering. XS118B3PAM12 is flush-mount with Sn = 8 mm.
- Non-Flush Mount: Sensing face must protrude from surrounding metal. Longer sensing distance; cannot be recessed into metal bore.
- Factor-1 (XS4): Near-identical sensing distance for steel, aluminium and copper. Preferred for non-ferrous-metal-target applications.
- IP69K: Rated for high-temperature high-pressure wash-down, for food-industry machinery.
- IO-Link versions: Support temperature reading, part-counting, remote NO/NC inversion and threshold adjustment; enables predictive-maintenance capability.
Contactor,circuit breaker,sensor,Encoder,PLC,Converter