(Código de pedido completo: BOS 18KF-PA-1QD-S4-C)
Tipo: M18 cylindrical retroreflective sensor fotoelétrico with transparent object detection capability
🔹 Core Technical Specifications
Fonte de luz: Red LED with polarizing filter
Alcance de detecção: 0~4.5 m (requires reflector)
Tensão de alimentação: 10~30 VCC
Saída: PNP, switchable NO / NC (normalmente aberto / normalmente fechado)
Conexão: Conector macho M12×1 de 4 pinos
Mechanical dimension: M18 threaded cylinder, Φ18 × 81.5 milímetros
Material de habitação: Plástico PBT; optical window: PMMA
Certificações: CE, UKCA, cULus
Peso: Aprox.. 33.3 g
Código HS: 85365019
🔹 Key Features
- Detecção de objetos transparentes: Reliably detects transparent films, glass bottles and clear plastic parts-this is the core advantage of this model.
- Straight flat optical window, fits standard M18 mounting holes.
- Visible status LED on the side for easy on-site commissioning.
- Red light with clear light spot, simple alignment with the reflector.
🔹 Typical Applications
Transparent material inspection on packaging lines, glass bottle detection, transparent film break monitoring, workpiece counting on conveyor lines, position confirmation in material handling & logistics systems.
🔹 Accessories & Opções de substituição
Must be used with a retroreflector (retroreflective principle; cannot detect targets without a reflector).
Interchangeable variants within the BOS 18KF series (different cable types, NPN output or IO-Link versions).
Alternativas domésticas: M18 retroreflective photoelectric sensors with transparent detection function; verificar 4.5 alcance m, PNP output and transparent sensing performance before replacement.
🔹 Pin Assignment (M12 4-pin Connector)
1: Brown-DC+
2: Black-Switching output
3: Blue-DC 0V (GND)
4: White-NO/NC function switching
White wire open-circuit = NO (padrão); white wire connected to GND = NC.
BOS00K3 (BOS 18KF-PA-1QD-S4-C) Comissionamento & Guia de solução de problemas
Princípio de funcionamento: Retroreflective photoelectric sensor optimized for transparent object detection. A reflector is mandatory; it does not work as a diffuse sensor.
- On-site Commissioning Procedure (follow step by step)
- Wiring Check
M12 4-pin pinout:
1 Marrom: DC+ 10~30V
3 Azul: CC 0V
2 Preto: Saída PNP
4 Branco: NO/NC switching
White wire floating: NÃO; white wire shorted to GND: NC
Never short positive and negative terminals; supply voltage must not exceed 30 CCV.
- Montagem & Seleção de Refletor
Recomendado original balluff reflectors: BOS-R10, BOS-R20. Generic reflectors work but reduce stability for transparent targets.
Keep the sensor face parallel to the reflector; deflection angle < 5°.
Keep operating distance between 0.3~4 m; avoid the full 4.5 m maximum range, leave 10% safety margin for stable operation.
Transparent workpieces must pass directly through the light beam between sensor and reflector; avoid oblique beam occlusion.
- Beam Alignment
Power on and slowly adjust the sensor angle until the green LED stays steadily lit (receiving reflected light from the reflector).
Insert the transparent workpiece into the beam: green LED turns off (signal triggered). Remove the workpiece, green LED lights up again.
Center the red light spot on the reflector for best anti-interference performance.
- Environmental Notes (critical for transparent detection)
Detection stability varies with material thickness and refractive index: thick glass bottles are easier to detect than thin PET films.
Condensação, oil stains or scratches on transparent surfaces will easily cause missed detections.
Avoid direct strong sunlight or high-bay lighting shining onto the optical window.
- Falhas Comuns, Causas & Soluções
| Fenômeno de falha | Causa raiz | Remédio |
| Green LED never lights up after power-on (sem luz de retorno) | ① Power polarity reversed; ② Reflector dirty/missing; ③ Misaligned angle; ④ Supply voltage below 10 CCV; ⑤ Dirty optical lens | Check positive/negative wiring; clean or replace reflector; re-align beam; measure supply voltage; wipe the sensor window |
| LED keeps on even when transparent workpiece blocks the beam | ① The beam is not fully blocked by the transparent part; ② The film is ultra-thin with very low light attenuation; ③ The reflector is too close; ④ Ambient stray light interference | Adjust beam position to ensure full occlusion; shorten sensing distance; add anti-glare shielding; switch to polarized reflector |
| Random signal flicker / falso acionamento | ① Lens or reflector contaminated with dust/oil; ② Vibration causing angle drift; ③ Shiny surrounding surfaces reflecting light back; ④ Voltage fluctuation | Regularly clean optical surfaces; lock the sensor mounting nut; install polarizing filter; stabilize the power supply |
Full Model List-BOS 18KF Series (Balluff M18 Straight-Body Photoelectric Sensors)
- Retroreflective Type (Transparent Detection Models-Main Series)
1) Cabo & Connector Versions (0~4.5 m, red light, detecção transparente)
- BOS00K2
Modelo: BOS 18KF-PA-1QD-C-02
Conexão: 2 m fixed PVC cable; PNP NO/NC comutável; detecção transparente; faixa 4.5 eu.
- BOS00K3 (Seu modelo atual)
Modelo: BOS 18KF-PA-1QD-S4-C
Conexão: Plugue M12 de 4 pinos; PNP NO/NC comutável; detecção transparente; faixa 4.5 eu.
- NPN equivalent: BOS 18KF-NA-1QD-S4-C (Número do pedido. BOS00K4).
- IO-Link intelligent version: BOS 18KF-PA-1QD-S4-IL (adjustable threshold via IO-Link).
Summary of differences:
C-02 = 2 m cabo fixo; S4-C = M12 4-pin connector
PA = PNP output; NA = NPN output; 1QD = retroreflective + detecção transparente (4.5 eu).
- Diffuse Sensors (No Reflector Required)
1) Standard Energy-Type Diffuse (Infrared Light)
BOS00K1: BOS 18KF-PA-1PE-S4-C; Plugue M12; PNP; sensing range 0~700 mm.
BOS00K0: BOS 18KF-PA-1PE-C-02; 2 m cabo; PNP; 0~700 mm.
2) Fixed Background Suppression (BGS, Anti-interferência)
BOS00JY: BOS 18KF-PA-1PD-C-02; 2 m cabo; 0~400 mm; background blanking.
BOS00JP: BOS 18KF-PA-1LOC-S4-C; Plugue M12; 0~350 mm; supressão de fundo.
3) Short-Range Laser Type (Small Light Spot)
BOS 18KF-PA-1N1R-S4-C (Número do pedido. BOS00JW); 5~100 mm; tiny laser spot for small target detection.
- Through-Beam Sensors (Transmitter BLS + Receiver BLE, Máx.. 20 eu)
Transmissor (BLS)
BOS00EP: BLS 18KF-XX-1P-S4-L; Plugue M12; infrared; range 0~20 m.
Receptor (BLE)
BOS00CK: BLE 18KF-PA-1PP-S4-C; Plugue M12; PNP; 0~20 m.
BOS00CH: BLE 18KF-PA-1LT-S4-C; laser version; máx.. 60 alcance m.
- BOS 18KF Model Coding Rule
BOS 18KF PA 1QD S4 C
- BOS = Photoelectric sensor; 18KF = M18 straight-body series
- PA = PNP output; NA = NPN output
- 1QD = Retroreflective + detecção transparente (4.5 eu)
1PE = Standard diffuse (700 milímetros)
1PD = Background suppression diffuse (400 milímetros)
- S4 = M12 4-pin connector; C-02 = 2 m cabo fixo
- C = Standard PBT plastic housing.
- Derivative Series: 90° Angled Head (BOS 18KW)
For tight installation space (side light emission):
BOS 18KW-PA-1QC-S4-C (retroreflective, 3 alcance m).
BOS 18KW-PA-1PD-C-02 (diffuse with background suppression).
- Direct Drop-In Replacements for BOS00K3 (Only Cable Type Differs)
- Cable version: BOS00K2 (BOS 18KF-PA-1QD-C-02).
- Versão do plug (modelo atual): BOS00K3.
- NPN plug variant: BOS00K4.
Contator,disjuntor,sensor,Codificador,CLP,Conversor