  Model Code Definition Segment Code Detailed Description NM8N Series Code New-generation moulded case circuit breaker (MCCB) of Chint; N stands for upgraded version with higher breaking capacity 1600 Frame Size Maximum frame current: 1600A S Breaking Capacity Grade Standard breaking type, 50o (ultimate short-circuit breaking capacity at 400V) E Trip Unit Type Electronic intelligent trip unit with ...

  • Detalhes do produto

 

  1. Model Code Definition
SegmentoCódigoDescrição detalhada
NM8NCódigo da sérieNew-generation moulded case circuit breaker (MCCB) of Chint; N stands for upgraded version with higher breaking capacity
1600Tamanho do quadroMaximum frame current: 1600UM
SBreaking Capacity GradeStandard breaking type, 50o (ultimate short-circuit breaking capacity at 400V)
ETipo de unidade de viagemElectronic intelligent trip unit with four-stage protection functions
MTipo de montagemTipo fixo; Opcional: P=Plug-in, D=Draw-out
3PNúmero do pólo3-pólo, for main protection of three-phase circuits
1250UMCorrente nominalSetting rated current In​=1250A, long-term stable operating current
50oCapacidade de ruptura finalIcu​=50kA@400V, maximum short-circuit current that can be safely disconnected
  1. Parâmetros técnicos principais
ItemValorObservações
Corrente nominal (In​)1250UMElectronic trip unit adjustable range: 800–1250A
Tamanho do quadro1600UMCompatible with trip units ≤1600A
Número do pólo3PMain protection for three-phase three-wire systems
Tipo de montagemFixoVertical / horizontal mounting available; top & bottom incoming line supported
Tensão nominal de isolamento (Ui​)1000VCompatível com IEC 60947-2
Tensão operacional nominal (Ue​)AC400V / AC690VApplicable to power distribution systems of different voltage levels
Ultimate Short-circuit Breaking Capacity (Icu​)50kA@400VStandard S type; Ics​=100%Icu​
Service Short-circuit Breaking Capacity (Ics​)50kA@400VResists multiple short-circuit current impacts
Tipo de unidade de viagemElectronic Intelligent Type (E)Four-stage protection: long delay, short delay, instantâneo & falha de terra
Tensão de controleStandard AC230V, optional DC220VPower supply for shunt trip, under-voltage trip and control circuit
Mechanical Endurance≥10,000 timesIndustrial long-life design
Resistência Elétrica≥5,000 timesMaking & breaking capacity under rated current
Temperatura ambiente-40℃ ~ +70 ℃Adaptable to harsh industrial environments
  1. Core Functions of Electronic Intelligent Trip Unit (E-Type)
  2. Full-range Protection: Accurate four-stage protection including long delay (tempo inverso), short delay (fixed/inverse time), viagem instantânea (fixed time) e falha de terra (fixed/inverse time).
  3. Monitoring Function: Real-time monitoring of three-phase current, fault current and operating status, with fault memory.
  4. Adjustable Parameters: Flexible adjustment of protection current and delay time for customized protection in various distribution systems.
  5. Communication Expansion: Optional Modbus-RTU communication module for remote monitoring and data transmission.
  6. Comprehensive Protection Features: Sobrecarga, curto-circuito, under-voltage, phase loss and three-phase unbalance protection to prevent equipment damage and electrical fire hazards.
  7. Cenários de aplicação
  8. Distribuição de energia industrial: Incoming/outgoing circuit protection for main distribution cabinets in workshops and production lines; control circuits for large-capacity motors.
  9. Edifícios Comerciais: Distribution trunk protection for shopping malls, hotels, office buildings and large commercial complexes.
  10. Infrastructure: Secondary power distribution protection for hospitals, schools, data centers and other key facilities.
  11. Energy Systems: Low-voltage distribution protection for photovoltaic power stations, wind power systems and substations.
  12. Proteção do Motor: Overload and short-circuit protection for infrequently started large-capacity motors (bombas de água, fãs, compressores, etc.).
  13. Complete Accessory List (Classified by Function)

5.1 Operação & Control Accessories

Nome do acessórioModeloFunçãoApplicable Scope
Viagem de manobraNM8N-FRemote opening control, AC230V/DC220V optionalFull series; for emergency shutdown and remote control
Under-voltage TripNM8N-UVTDelayable under-voltage protection to avoid equipment damage from undervoltageFull series; essential for critical loads
Closing SolenoidNM8N-CERemote closing control for automatic control systemsFull series; for frequent operation
Electric Operating MechanismMOD22-M8Electric energy storage, closing & opening to improve operation efficiency1600Um quadro; suitable for unattended power distribution rooms
External Operating HandleRH11Extended cabinet external operation for safety and convenienceFull series

5.2 Auxiliar & Alarm Accessories

Nome do acessórioModeloConfiguração de contatoFunção
Contato AuxiliarNM8N-A1/A2/A41/2/4 changeover contactsCircuit breaker status indication and control circuit expansion
Contato de alarmeNM8N-B1/B21/2 changeover contactsFault alarm signal output and equipment linkage
Auxiliar & Alarm CombinationNM8N-AB2 contatos auxiliares + 1 contato de alarmeIntegrated status monitoring and space saving
Prepaid Trip UnitNM8N-PPRemote power cut-offLinked with prepaid system for automatic power outage on arrears

5.3 Conexão & Mounting Accessories

Nome do acessórioModeloApplicable FrameFunção
Phase BarrierNM8N-IS16001600Um quadroStandard inter-phase insulation barrier to prevent arc spreading
Front Connection PlateFM221600Um quadroDedicated for front wiring; enlarged terminal area for cable connection
Rear Wiring KitNM8N-RB1600Um quadroDedicated for rear wiring, suitable for draw-out cabinets
Plug-in BaseNM8N-IB1600Um quadroPlug-in installation for easy maintenance and replacement
Terminal Protective CoverNM8N-COVER1600Um quadroDustproof and anti-touch protection for wiring terminals

5.4 Segurança & Expansion Accessories

Nome do acessórioModeloFunçãoAplicativo
Key LockNM8N-KLLock on/off status to prevent misoperationPublic areas and key equipment protection
Padlock DeviceNM8N-LOCKLock circuit breaker at open position for safety isolationEquipment maintenance and overhaul
Módulo de ComunicaçãoNM8N-MODModbus-RTU protocol for remote monitoring and data uploadSmart power distribution and IoT systems
Residual Current Protection ModuleNM8N-LLeakage protection against electric shock and equipment leakage failureHumid environments and densely populated areas
  1. Cross-Brand Equivalent Comparison (Mainstream MCCB)
Chint NM8N ModelSchneider NSXABB Tmax XTSiemens 3VTChang Shu CM3Observações
NM8N-1600SEM-3P-1250A-50kANSX1600N 1250A Micrologic 5.0XT4S1600 TMD 1250A 50kA3VT8416-1AA03-0AA0CM3-1600H/3340 1250A1600Um quadro, viagem eletrônica, 50quebra de kA
NM8N-1600SPM-3P-1250A-50kANSX1600N 1250A Micrologic 2.0XT4S1600 TMD 1250A 50kA3VT8416-1AA03-0AA0CM3-1600H/3300 1250APlug-in type, standard protection
NM8N-1600EDM-3P-1250A-50kANSX1600N 1250A Micrologic 5.0XT4S1600 TMD 1250A 50kA3VT8416-1AA03-0AA0CM3-1600H/3340 1250ADraw-out type, intelligent protection
  1. Seleção & Procurement Guidelines
  2. Breaking Capacity Selection: 50kA standard S type for general industrial and commercial distribution; select H type (70o) or HH type (100o) for higher breaking requirements.
  3. Trip Unit Selection: Electronic intelligent E-type for precise protection and remote monitoring; thermal-magnetic T-type for conventional distribution scenarios.
  4. Tipo de montagem: Low-cost fixed type (M); replaceable plug-in type (P); draw-out type (D) for critical load maintenance.
  5. Accessory Configuration:

Essential: 1~2 sets of auxiliary contacts and under-voltage trip for basic control and protection.

Opcional: Electric operating mechanism, communication module and residual current module to enhance intelligence and safety.

  1. Conformidade de Certificação: Compliant with GB14048.2 and IEC 60947-2, with CE & UL certifications to ensure product quality and operational safety.

Chint NM8N Series MCCB Complete Model List & Price Guide

  1. Complete Naming Rule

NM8N-□□□□-□□-□□-□P

SegmentoDefiniçãoOptional CodeDescrição
NM8NSérieFixoChint upgraded MCCB series with enhanced breaking performance
Tamanho do quadroMax frame current125,160,250,400,630,800,1250,1600Covering 125A~1600A rated current
Breaking GradeShort-circuit capacityS(Padrão),H(Alto),R(Current-limiting),P, CS=50kA, H=70kA, R=100kA, Q=120kA, C=150kA@400V
Tipo de viagemProtection modeMT(Thermal-Magnetic), EM(Eletrônico)MT: overload inverse time + instantaneous short-circuit; EM: four-stage intelligent protection
Corrente nominalSetting current16~1600AElectronic trip adjustable: 63%~100% of rated current
MontagemInstallation formM(Fixo), P(Plug-in), D(Draw-out)Universal installation options for cabinet design
Número do póloMain poles1P/2P/3P/4B/4C4B: 4-pólo (N non-protected); 4C: 4-pólo (N protected)
Breaking CurrentEUcu25/36/50/70/100/120/150o400V short-circuit breaking parameter
  1. Full Model List by Frame Size

2.1 125Um quadro (NM8N-125)

BreakingViagemEmMountPóloModeloPreço de referência(USD)
S(50o)MT63~125AM3PNM8N-125S TM 125 M 3P65–80
S(50o)EM80~125AM4CNM8N-125S EM 100 M 4C108–128
H(70o)MT100~125AP3PNM8N-125H TM 125 P 3P90–108
R(100o)EM125UMD3PNM8N-125R EM 125 D 3P165–205

2.2 250Um quadro (NM8N-250)

BreakingViagemEmMountPóloModeloPreço de referência(USD)
S(50o)MT160~250AM3PNM8N-250S TM 250 M 3P136–160
P(120o)MT125~160AM2PNM8N-250Q TM 125 M 2P272–305
H(70o)EM200~250AP3PNM8N-250H EM 250 P 3P233–270
R(100o)EM250UMD4CNM8N-250R EM 250 D 4C318–368

2.3 400Um quadro (NM8N-400)

BreakingViagemEmMountPóloModeloPreço de referência(USD)
S(50o)MT315~400AM3PNM8N-400S TM 400 M 3P180–215
C(150o)MT315~400AM3PNM8N-400C TM 400 M 3P248–290
H(70o)EM350~400AP3PNM8N-400H EM 400 P 3P330–385
R(100o)EM400UMD4CNM8N-400R EM 400 D 4C440–500

2.4 630Um quadro (NM8N-630)

BreakingViagemEmMountPóloModeloPreço de referência(USD)
S(50o)MT500~630AM3PNM8N-630S TM 630 M 3P305–355
H(70o)MT630UMM4CNM8N-630H TM 630 M 4C388–445
R(100o)EM500~630AP3PNM8N-630R EM 630 P 3P528–595
C(150o)EM630UMD3PNM8N-630C EM 630 D 3P665–750

2.5 800Um quadro (NM8N-800)

BreakingViagemEmMountPóloModeloPreço de referência(USD)
S(50o)MT630~800AM3PNM8N-800S TM 800 M 3P430–495
H(70o)EM800UMM4CNM8N-800H EM 800 M 4C585–655
R(100o)EM800UMP3PNM8N-800R EM 800 P 3P735–820
C(150o)EM800UMD3PNM8N-800C EM 800 D 3P905–1005

2.6 1250Um quadro (NM8N-1250)

BreakingViagemEmMountPóloModeloPreço de referência(USD)
S(50o)MT1000~1250AM3PNM8N-1250S TM 1250 M 3P665–750
H(70o)EM1250UMM3PNM8N-1250H EM 1250 M 3P860–960
R(100o)EM1250UMP3PNM8N-1250R EM 1250 P 3P1040–1150
C(150o)EM1250UMD4CNM8N-1250C EM 1250 D 4C1290–1415

2.7 1600Um quadro (NM8N-1600)

BreakingViagemEmMountPóloModeloPreço de referência(USD)
S(50o)MT1250~1600AM3PNM8N-1600S TM 1600 M 3P905–1005
S(50o)EM1250UMM3PNM8N-1600S EM 1250 M 3P1220–1350
H(70o)EM1600UMM3PNM8N-1600H EM 1600 M 3P1450–1610
R(100o)EM1600UMD3PNM8N-1600R EM 1600 D 3P1795–2010
  1. Série Especial

3.1 DC MCCB (NM8NDC)

QuadroAtualBreakingPóloModeloPreço(USD)
125UM100UM25o2PNM8NDC-125B TM 100 2P80–95
400UM315UM36o3PNM8NDC-400C TM 315 3P248–290
1600UM800UM36o3PNM8NDC-1600C TM 800 3P720–805

3.2 Leakage Protection MCCB (NM8NL)

QuadroAtualLeakage CurrentPóloModeloPreço(USD)
125UM63UM500mA4BNM8NL-125S TM 63 4B RCD2510–550
250UM160UM2000mA3PNM8NL-250S EM 160 3P RCD4990–1050
400UM315UM500mA4CNM8NL-400H EM 315 4C RCD41360–1460
  1. Price Factors & Purchasing Advice

4.1 Price Influencing Factors

FactorPrice FluctuationExplicação
Breaking Grade+20%~+150%Price rises 20%~30% per grade from S to C type
Unidade de viagem+40%~+80%Electronic EM type 40%~80% higher than thermal-magnetic TM type
Tipo de montagem+15%~+40%Plug-in +15%~20%, Draw-out +30%~40% vs fixed type
Número do pólo+10%~+50%4-pole 10%~20% higher than 3-pole
Corrente nominal+5%~+30%Higher current within the same frame leads to higher cost
Acessórios+10%~+100%Viagem de manobra +10%, under-voltage trip +15%, electric mechanism +80%~100%

4.2 Selection Tips

  1. Quebrando Capacidade: S(50o) for general use; H(70o) for heavy industrial; R(100o) for key facilities.
  2. Unidade de viagem: TM for conventional distribution; EM for intelligent monitoring and precise protection.
  3. Mounting Solution: Fixed for cost-saving; Plug-in for easy replacement; Draw-out for critical loads.
  4. Certificação: Meet GB & IEC standards with CE/UL certification for global project delivery.
  5. Quick Selection Reference
AplicativoModelo recomendadoParâmetros principaisPreço(USD)
Residential DistributionNM8N-125S TM 100 M 3P125Um quadro, 100UM, 50o, 3P65–80
Edifício comercialNM8N-250S TM 200 M 3P250Um quadro, 200UM, 50o, 3P136–160
Industrial WorkshopNM8N-400H EM 350 M 3P400Um quadro, 350UM, 70o, viagem eletrônica330–385
Large FactoryNM8N-800R EM 800 P 3P800Um quadro, 800UM, 100o, plug-in735–820
Centro de dadosNM8N-1600C EM 1600 D 3P1600Um quadro, 1600UM, 150o, draw-out1795–2010

Observação: All prices are 2026 April market reference prices. Actual prices vary by purchase quantity, region and distributor. Confirm official quotation from authorized Chint dealers before ordering.

 