Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Sobretensão de reinicialização automática Chint & Protetor de Subtensão ABERTO - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

Sobretensão de reinicialização automática Chint & Protetor de Subtensão ABERTO

The Chint Self-Resetting Over-Voltage & Under-Voltage Protector OUVR Series is a new type of intelligent protection electrical device. It can automatically cut off the circuit when over-voltage or under-voltage occurs in the line, and automatically reconnect the circuit once the voltage returns to normal. Product Models OUVR-1: As the basic model of this series, it ...

  • Detalhes do produto

O Sobretensão de reinicialização automática Chint & Under-Voltage Protector OUVR Series is a new type of intelligent protection electrical device. It can automatically cut off the circuit when over-voltage or under-voltage occurs in the line, and automatically reconnect the circuit once the voltage returns to normal.

Product Models

OUVR-1: As the basic model of this series, it adopts a modular standard design, available in pole configurations such as 1P+N and 3P+N, with rated current specifications including 32A, 40UM, 50UM, 63UM, and 80A.

OUVR-2: An upgraded version of OUVR-1, it features compact size, built-in wires, high-altitude adaptability and wide temperature rise tolerance. It also comes in 1P+N and 3P+N pole types, with rated current specifications similar to OUVR-1.

OUVR-3: A digital display type over-voltage and under-voltage protector equipped with a voltage display function. It can show the line voltage in real time, enabling users to intuitively monitor the voltage status.

 

Recursos do produto

Anti-malfunction: The protector will not trip when sudden transient over-voltage occurs in the line; it will not reconnect the circuit in case of voltage instability caused by poor contact or similar faults, or when power supply resumes abruptly after a sudden outage.

Reliable operation: The protection operates with an inverse time-lag characteristic, com tempo de operação ≤ 1 segundo.

Wide voltage protection range: The voltage protection range is 0-450V. The protector itself will not be damaged even when the line fault voltage reaches the maximum level.

Surge voltage withstanding capacity: It can withstand a 4kV surge voltage, complying with the safety standards for Class III electrical appliances.

Status indication: The protector is equipped with LED indicators to show its working status. The green light indicates normal voltage, while the red light indicates over-voltage or under-voltage conditions.

Easy installation: With a modular design, it is mounted on a DIN rail, allowing convenient installation inside distribution boxes.

Parâmetros Técnicos

Taking OUVR-1 as an example, its over-voltage tripping value is 270V±5V, under-voltage tripping value is 170V±5V, over-voltage recovery value ranges from 240V to 260V, under-voltage recovery value ranges from 185V to 195V, and the self-reset delay time is 30s±10s.

Scope of Application

It is suitable for users or loads with an AC voltage of 230/400V, a frequency of 50Hz, and a rated operating current of 80A or below. It is mainly used in residential sub-distribution boxes or other distribution lines requiring protection, and can prevent accidents caused by abnormal voltage supplied to terminal electrical appliances.

Dimensões & Instalação

Dimensões: The 1P+N version of the OUVR-2 series only occupies 27mm of space, and the 3P+N version takes up 54mm. Its compact size saves installation space.

Installation method: It is installed on TH35-7.5 steel mounting rails, with the inclination angle between the mounting surface and the vertical plane not exceeding 5°.

Application Scenarios of Chint OUVR Series Self-Resetting Over-Voltage & Protetor de subtensão

The Chint OUVR Series (the termQUERYVRmentioned by the user is a misnomer) is an intelligent over-voltage and under-voltage protection device. It is mainly applicable to users or loads with an AC voltage of 230/400V, a frequency of 50Hz, and a rated operating current ≤ 80A. It can quickly cut off the circuit during over-voltage/under-voltage events and automatically reset when the voltage returns to normal, making it ideal for unattended scenarios. Below are detailed application scenarios and boundary specifications:

  1. Basic Application Conditions (Mandatory Requirements)
Parameter ItemSpecification RequirementsRemarks
Faixa de tensão230V/400V (Single-phase/Three-phase)Suitable for household and small commercial power grids
Frequency50HzStandard power frequency grid
Corrente nominal≤ 80ACovering specifications such as 32A, 40UM, 50UM, 63UM, and 80A
Installation EnvironmentDry, free of flammable and explosive gases, sem condensaçãoProhibited for use in humid, corrosive, or dusty environments
Mounting MethodTH35-7.5 steel DIN railStandard installation position in distribution boxes, inclination ≤ 5°
  1. Core Application Scenarios
  2. Residential Sub-distribution Boxes (Most Mainstream)

Application Objective: Protect the main household circuit and terminal electrical appliances (geladeiras, condicionadores de ar, TVs, smart home devices, etc.)

Pain Points Solved:

Electrical appliance damage caused by grid fluctuations (por exemplo, lightning strikes, transformer failures)

Abnormal operation of electrical appliances due to unstable power supply in old residential communities

Damage from surge when power resumes abruptly after an outage (equipped with anti-reconnection function)

Recommended Models: OUVR-1/2 (1P+N) for single-phase household entry, OUVR-1/2 (3P+N) for three-phase villas

  1. Distribution Lines in Public Buildings
Building TypeSpecific Application LocationProtection Value
Office Buildings/ApartmentsFloor distribution boxes, public lighting circuitsEnsure stable operation of office equipment and public lighting
Shops/Convenience StoresCash register systems, cold chain equipment, lightingAvoid business interruption caused by abnormal voltage
Schools/HospitalsFront-end of laboratory equipment and medical instrumentsPrevent damage to precision equipment due to voltage fluctuations
Small FactoriesControl circuits, auxiliary equipmentProtect weak current equipment such as PLCs and sensors
  1. Special Protection for Specific Loads

Sensitive electronic devices: Computers, servers, monitoring systems, preventing motherboard/power supply breakdown due to over-voltage

Continuous operation equipment: Refrigerators, freezers, bombas de água, avoiding motor burnout caused by under-voltage

Smart home systems: Gateways, smart switches, security devices, ensuring continuous system operation

Building supporting facilities: Lighting, ventilation, heating, water supply systems, compatible with the high-altitude and wide temperature rise characteristics of the OUVR-2 series

III. Scenario Adaptation Differences by Model

ModeloCore FeaturesOptimal Application Scenarios
OUVR-1Basic version, tamanho compactoSub-distribution boxes of ordinary residences and old residential communities
OUVR-2Upgraded version, built-in wires, suitable for high-altitude environmentsNewly renovated residences, high-rise/super high-rise apartments, buildings in plateau areas
OUVR-3Digital display version, real-time voltage displayLaboratories, computer rooms, and precision equipment scenarios sensitive to voltage
OUVR-5Enhanced version, stronger surge resistanceCritical loads in areas with frequent lightning strikes and unstable power grids
  1. Extended Application Scenarios (Requiring Matching Selection)
  2. Photovoltaic/Energy Storage Systems

Application Position: Protection at the output end of inverters before grid connection

Core Function: Prevent inverter damage caused by over-voltage from photovoltaic panels (por exemplo, under strong sunlight on sunny days) or grid voltage loss

Selection Key Points: Must match the output voltage and current of the inverter; the OUVR-5 series is recommended (withstanding 4kV surge voltage, complying with Class III electrical appliance standards)

  1. Front-end of Small Charging Piles

Protection Target: Electric vehicle charging guns and charging controllers

Problem Solved: Charging module failures caused by grid fluctuations, avoiding charging interruptions or damage to vehicle batteries

Observação: Must be used in conjunction with dedicated residual current protectors for charging piles; it cannot replace surge protection devices (SPDs)

  1. Non-Applicable Scenarios (Clear Boundaries)
  2. Industrial heavy-load scenarios: Motores, frequency converters, welding machines with rated current > 80UM (industrial-grade over-voltage and under-voltage protectors are required)
  3. Flammable and explosive environments: Gas stations, chemical workshops, coal mines, etc.. (violates safety regulations)
  4. DC circuits: The OUVR series is only suitable for AC circuits; dedicated DC over-voltage and under-voltage protection devices are required for DC systems
  5. Core lightning protection: Cannot replace SPDs; they must be used together to handle instantaneous lightning-induced over-voltage
  6. Scenario Selection Quick Reference Table
CenárioRecommended ModelPole ConfigurationCorrente nominalInstallation Tips
Ordinary Residence (Single-phase)OUVR-1/21P+N40A/63AInstall after the household main switch
Villa (Three-phase)OUVR-1/23P+N63A/80ASuitable for three-phase household entry distribution boxes
Shop/Convenience StoreOUVR-21P+N50A/63ABuilt-in wires for easy installation
Computer Room/LaboratoryOUVR-31P+N/3P+N32A/40ADigital display for real-time voltage monitoring
Residence in Lightning-prone AreaOUVR-51P+N/3P+N40A/63AEnhanced surge resistance

Vii. Instalação & Usage Recommendations

  1. Especificações de fiação: Strictly distinguish between the neutral (N) pole and phase lines; the N pole must be correctly connected with reliable wiring.
  2. Matching Devices: It is recommended to install a circuit breaker (por exemplo, Chint DZ47 series) at the front end, and connect loads at the rear end, forming a protection chain of “disjuntor + OUVR + load”.
  3. Maintenance Tips: Regularly check the LED status indicators (green = normal, red = over-voltage/under-voltage) to ensure the protection function is effective.

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado