Apresentando estrutura compacta, high-efficiency control and reliable performance, Danfoss FC-051P18KT4E20H3BXCXXXSXXX inverter delivers outstanding performance in fields including fans & bombas de água, material handling, comida & textile industry, tratamento de água, achieving an average energy-saving rate of 30-50%. It also extends service life of equipment, improves product quality and cuts maintenance costs. Reasonable configuration shall be conducted according to load characteristics, ambient conditions and control requirements during model selection to maximize its technical advantages.
- Definição de código de modelo
| Código | Significado | Descrição detalhada |
| FC-051 | Código da série | VLT® Micro Drive FC-51 Compact General-purpose Inverter Series |
| P18K | Classificação de potência | Matched motor power: 18.5kW / 25HP |
| T4 | Power Supply Spec. | T=Three-phase input; 4=380-480VAC voltage class |
| E20 | Classe de Proteção | Proteção IP20, chassis mounting type |
| H3 | RFI Filter | Equipped with RFI Class A1/B (C1) filtro |
| B | Unidade de freio | Chopper de freio integrado |
| X | Local Control Panel | Without local control panel (LCP to be ordered separately) |
| C | PCB Coating | Coated printed circuit board for higher reliability in harsh environments |
| X | Power Option | Standard power configuration without special options |
| X | Adapter A | Standard cable entry |
| X | Adapter B | No extra adapters |
| SXXX | Versão do software | Latest standard software version |
| M5 | Tamanho do quadro | M5 frame (corresponding to 18.5kW power grade) |
| Número do pedido. | 132F0060 | Official unique identification code |
- Especificações Técnicas Principais
| Categoria | Especificação | Observações |
| Parâmetros Básicos | ||
| Potência nominal | 18.5kW / 25HP | Matched motor power |
| Corrente de saída nominal | 37UM (Serviço Pesado) / 34UM (Light-duty) | Current values for different load types |
| Tensão de entrada | 3-phase 380-480VAC | Allowable fluctuation: ±10% |
| Frequência de entrada | 50/60Hz | Auto-adaptive |
| Tensão de saída | 0~100% of input voltage | Varies with frequency |
| Frequência de saída | 0-200Hz (VVC+ Mode) / 0-400Hz (U/f Mode) | Controle vetorial / V/f ratio control |
| Control Features | ||
| Modo de controle | VVC+ (Voltage Vector Control), U/f Control | Closed-loop vector control available (encoder optional) |
| Capacidade de sobrecarga | 150% corrente nominal para 60 segundos | Standard overload protection |
| Acc/Dec Time | 0.1~3600s | Acceleration and deceleration time set independently |
| Entrada Digital | 5 programmable inputs | Support PNP/NPN logic, 0-24CCV |
| Entrada Analógica | 1 channel 0-10V/4-20mA | Programmable functions |
| Saída de relé | 2 canais (1 NÃO + 1 NC) | Max switching capacity: 250VAC/2A |
| Propriedades Físicas | ||
| Grau de Proteção | IP20 | Chassis mounting |
| Método de resfriamento | Resfriamento natural + forced air cooling | M5 frame with built-in fan |
| Temperatura ambiente | -20°C ~ +50°C | Derating operation required above 40°C |
| Umidade relativa | 5%~95%, sem condensação | Standard industrial environment requirement |
| Peso | Aprox.. 9.98kg (net weight) | Aprox.. 10.27kg with package |
| Certificação & Conformidade | ||
| Safety Certifications | CE, UL, cUL, RoHS | Compliant with EU Low Voltage Directive 2014/35/EU |
| EMC Standard | EM 55011 Classe A | EMC requirement for industrial environment |
| ECCN Code | EU: Y901, NÓS: 3A999.a | Export control classification code |
- Full Series Model List (380-480V Three-phase)
| Poder | Modelo | Número do pedido | Corrente nominal | Tamanho do quadro |
| 0.37kW | FC-051PK37T4E20H3BXCXXXSXXX | 132F0001 | 1.1UM | M1 |
| 0.75kW | FC-051PK75T4E20H3BXCXXXSXXX | 132F0002 | 2.1UM | M1 |
| 1.5kW | FC-051P1K5T4E20H3BXCXXXSXXX | 132F0003 | 3.7UM | M1 |
| 2.2kW | FC-051P2K2T4E20H3BXCXXXSXXX | 132F0004 | 5.2UM | M1 |
| 3.0kW | FC-051P3K0T4E20H3BXCXXXSXXX | 132F0024 | 7.0UM | M2 |
| 4.0kW | FC-051P4K0T4E20H3BXCXXXSXXX | 132F0025 | 9.3UM | M2 |
| 5.5kW | FC-051P5K5T4E20H3BXCXXXSXXX | 132F0026 | 12.5UM | M3 |
| 7.5kW | FC-051P7K5T4E20H3BXCXXXSXXX | 132F0027 | 17.0UM | M3 |
| 11kW | FC-051P11KT4E20H3BXCXXXSXXX | 132F0059 | 25.0UM | M4 |
| 15kW | FC-051P15KT4E20H3BXCXXXSXXX | 132F0060 | 32.0UM | M5 |
| 18.5kW | FC-051P18KT4E20H3BXCXXXSXXX | 132F0060 | 37.0UM | M5 |
| 22kW | FC-051P22KT4E20H3BXCXXXSXXX | 132F0061 | 45.0UM | M5 |
- Cross-brand Equivalent Model Comparison
| Danfoss FC-051P18KT4E20H3BXCXXXSXXX | Siemens | Schneider | ABB | Replacement Suggestion |
| 18.5kW/37A/380-480V | SINAMICS G120C 6SL3210-1KE22-6UF1 | Altivar 320 ATV320U40N4 | ACS150-03E-04A1-4 | Similar functions, communication protocols need matching |
| Modo de controle: VVC+/U/f | Controle vetorial | Controle vetorial | DTC Direct Torque Control | ABB features fastest dynamic response; Schneider offers higher cost performance |
| Chopper de freio integrado | External accessory required | Integrado | External accessory required | Danfoss features more flexible configuration |
| RFI Class A1/B | Optional Class A/B | Built-in Class A | Optional Class A/B | Meet industrial EMC standards |
| Without LCP (adquirido separadamente) | Standard BOP-2 | Standard keypad | Standard assistant control panel | Siemens owns friendliest operation interface |
Obsolete Replacement: FC-051 is still mainstream without direct discontinued substitutes. For function upgrade, choose Danfoss FC-301 series with richer functions and support for PROFINET and other advanced communication protocols.
- Ambiente de aplicação & Industry Cases
Cenários Aplicáveis
Fãs & Water Pumps: Sistemas HVAC, water treatment plants, cooling towers, realize 30%-50% energy saving via variable frequency speed regulation
Material Conveying: Transportadores, guinchos, máquinas de embalagem, achieve smooth start/stop and precise speed control
Comida & Beverage Industry: Filling lines, máquinas de etiquetagem, sterilization equipment, adapt to humid environment with PCB coating protection
Máquinas Têxteis: Spinning machines, weaving machines, satisfy low-speed high-torque demands
Small Machine Tools: Drilling machines, milling machines, grinders, realize accurate speed adjustment
Non-recommended Scenarios
Heavy-duty impact loads: Such as crushers and punch presses (FC-302 series is recommended)
Explosion-proof occasions: Special explosion-proof models required (FC-051 has no explosion-proof certification)
Altitude above 1000m: Derating operation needed (1% power reduction per 100m rise)
Ambient temperature over 50°C: Additional cooling measures or derating operation required
Casos de aplicação típicos
- Constant Pressure Water Supply System
Adopt FC-051P18KT4 to control 18.5kW water pump with closed-loop control via pressure sensor, realizing 40% economia de energia, stabilizing pipeline pressure and extending equipment service life.
- Packaging Production Line
Four sets of FC-051 series inverters including 18.5kW model are applied to control conveyor speed for synchronous operation, lowering product damage rate and greatly reducing downtime frequency.
- Central Air-conditioner Fan System
Applied in shopping mall air conditioner fans to adjust rotating speed automatically by ambient temperature, economizando cerca de 28,000 RMB electricity fee annually per unit and reducing operating noise.
- Air Freight Compliance & Certificação
Air Freight Regulations
Built-in Capacitor: Equipped with DC bus electrolytic capacitors without lithium batteries, UN38.3 test report is not required
Transport Classification: Non-dangerous goods, deliverable as common electronic products by air
Packaging Requirements
Power off completely with capacitors discharged for more than 5 minutos
Fixed in anti-static package to avoid collision damage
Mark with labels of “Fragile Electronic Equipment” e “This Side Up”
Main Certifications
| Código de falha | Descrição da falha | Possíveis causas | Etapas de solução de problemas |
| AL16 | Output Short Circuit | 1. Motor winding short circuit | 1. Cut off power and disconnect UVW motor wiring |
| 2. Damaged motor cable | 2. Test three-phase motor winding resistance balance | ||
| 3. Power module failure | 3. Check cable insulation condition | ||
| 4. Reset and test inverter output under no-load state | |||
| AL10 | Motor Overheating | 1. Overloaded operation | 1. Confirm actual load within rated range |
| 2. Poor motor heat dissipation | 2. Clean motor heat sink | ||
| 3. Temperature sensor failure | 3. Inspect PT100 and thermistor connection | ||
| AL51 | DC Bus Undervoltage | 1. Low input voltage | 1. Measure input voltage (normal range: 342-528V) |
| 2. Phase loss of power supply | 2. Check three-phase power balance | ||
| 3. Rectifier bridge failure | 3. Detect rectifier module output | ||
| AL71 | Inverter Overheating | 1. Excessively high ambient temperature | 1. Ensure ambient temperature ≤40°C |
| 2. Cooling fan malfunction | 2. Check fan running status | ||
| 3. Radiator blockage | 3. Remove dust and sundries on radiator | ||
| AL52 | Input Phase Loss | 1. Power supply phase missing | 1. Measure three-phase input voltage |
| 2. Loose wiring terminals | 2. Fasten terminal wiring | ||
| 3. Faulty input contactor | 3. Test contactor switching performance |
- Falhas Comuns & Guia de solução de problemas
| Nome do acessório | Modelo | Função | Necessity |
| Local Control Panel | LCP 12 | On-site parameter setting and monitoring | Recomendado (not standard equipped) |
| Brake Resistor | MCE 101-0300 | Dissipate regenerative energy and prevent overvoltage | Mandatory for models with code B |
| Módulo de Comunicação | FC CAN/Profibus | Realize industrial network connection | Optional on demand |
| Input Filter | H3 Upgrade Kit | Upgrade EMC performance to Class B | Recommended for electromagnetic sensitive occasions |
| Capa protetora | FC-051-IP40 | Upgrade protection class to IP40 | Recommended for dusty working sites |
- Selection Rules & Quick Tips
- Combinação de poder: Inverter rated current ≥ 1.1 times motor rated current to cope with starting impact
- Voltage Confirmation: Input voltage shall stay within 380-480V with fluctuation ≤±10%
- Brake Configuration: Models with code B have built-in brake choppers, external brake resistors required (power ≥ 30% of motor power)
- Dissipação de Calor: Keep ventilation space over 10cm for M5 frame; desclassificar 10% power per 5°C rise above 40°C
- Expansão da Comunicação: Additional Modbus/Profibus modules need separate purchase for network communication
- Recommended Key Accessories
| Nome do acessório | Modelo | Função | Necessity |
| Local Control Panel | LCP 12 | On-site parameter setting and monitoring | Recomendado (not standard equipped) |
| Brake Resistor | MCE 101-0300 | Dissipate regenerative energy and prevent overvoltage | Mandatory for models with code B |
| Módulo de Comunicação | FC CAN/Profibus | Realize industrial network connection | Optional on demand |
| Input Filter | H3 Upgrade Kit | Upgrade EMC performance to Class B | Recommended for electromagnetic sensitive occasions |
| Capa protetora | FC-051-IP40 | Upgrade protection class to IP40 | Recommended for dusty working sites |
Full Analysis on Application Cases of Danfoss FC-051P18KT4E20H3BXCXXXSXXX (18.5kW) Inversor
- Overview of Core Application Fields
This 18.5kW/37A/380-480V inverter with built-in brake chopper and coated PCB board is widely applied relying on VVC+ vector control, IP20 protection and high cost performance:
HVAC industry: Central air conditioner fans, cooling towers, bombas de água
Tratamento de água: Abastecimento de água com pressão constante, aeration tanks, sludge return pumps
Manuseio de materiais: Heavy-duty conveyors, elevadores, logistics sorting lines
Food industry: Máquinas de enchimento, sterilization equipment, packaging machines
Textile industry: Spinning machines, weaving machines, setting machines
Building material machinery: Misturadores, light-duty crushers
- Detailed Introduction of Five Typical Application Cases
Caso 1: Constant Pressure Water Supply for Residential Communities
Original power frequency water supply system suffered from severe pressure fluctuation, high power consumption and frequent pump startup-stop. After adopting FC-051 constant pressure frequency conversion control system with pressure sensor feedback, it realizes sleep & wake-up automatic operation, cutting daily power consumption greatly, stabilizing water supply pressure and prolonging pump service life obviously.
Caso 2: Central Air-conditioner Fan System in Shopping Malls
Replace fixed-speed fan operation with variable frequency temperature closed-loop control, set minimum frequency to avoid fan surging, realize intelligent speed regulation according to indoor temperature, save massive electricity cost annually and lower operating noise effectively.
Caso 3: Food Packaging Production Line Multi-machine Linkage
Adopt multi-speed regulation and synchronous follow-up control to match operating speed of different conveying equipment. Built-in brake chopper achieves rapid stop, reduces material stacking and product damage rate, and improves overall production efficiency. Coated PCB adapts to humid and dusty food workshop environment.
Caso 4: Spinning Machine Control System in Textile Mill
Replace traditional slip speed regulating motor with VVC+ vector control inverter, realize high torque output at low speed, broaden speed regulation range, promote motor operating efficiency, reduce yarn breakage rate and cut daily maintenance frequency.
Caso 5: Aeration System for Sewage Treatment Plant
Match dissolved oxygen sensor to build PID closed-loop control system, automatically adjust fan air volume to keep dissolved oxygen content in optimal range, stabilize sewage treatment effect, reduce invalid energy consumption and lower equipment abrasion.
- Application Scene Matching Table
| Application Scene | Matching Level | Principais vantagens | Notas |
| Abastecimento de água com pressão constante / circulating pump | ★★★★★ | PI regulation + intelligent logic, prominent energy-saving effect | Equipped with pressure sensor and brake resistor suggested |
| Central air conditioner / cooling tower fan | ★★★★★ | Temperature closed-loop control, low noise and energy saving | Surge prevention setting required, derate at high altitude |
| Heavy conveyor / hoist | ★★★★☆ | Stable start-stop, strong overload resistance | Confirm actual load type in advance |
| Comida & beverage production line | ★★★★☆ | Multi-speed control, high synchronization precision | Coated PCB for humid environment adaptation |
| Textile printing & dyeing machinery | ★★★★☆ | Low-speed high torque, wide speed range | Add anti-interference measures |
| Sewage treatment aeration system | ★★★★☆ | Precise PID control, energy consumption optimization | Regular radiator cleaning required |
| Heavy impact load equipment | ★☆☆☆☆ | – | Choose FC-302 series instead |
| Explosion-proof working environment | ★☆☆☆☆ | – | Special explosion-proof inverters required |
| Altitude over 2000m | ★☆☆☆☆ | – | Not recommended due to large power derating amplitude |
- Key Selection Points for Practical Application
- Match inverter current reasonably according to actual motor load
- Select models with built-in brake units for frequent start-stop and fast stop working conditions
- Choose U/f control mode for fan & pump loads, VVC+ vector control for transmission and processing equipment
- Prioritize coated PCB models for humid, dusty and corrosive sites
- Select matched external accessories and control panels according to on-site debugging and remote control demands
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares




















NH42-63-318x560.png)