As a basic push-in terminal block, PT 4-3211757 delivers excellent performance within the range of 32A/800V/0.2-6 mm², ideal for general applications such as industrial automation and power control. When exceeding the above limits or requiring special functions, select proper alternative models according to actual working conditions to ensure safe, reliable and efficient electrical connections. Modelo ...

  • Detalhes do produto

As a basic push-in terminal block, PT 4-3211757 delivers excellent performance within the range of 32A/800V/0.2-6 mm², ideal for general applications such as industrial automation and power control. When exceeding the above limits or requiring special functions, select proper alternative models according to actual working conditions to ensure safe, reliable and efficient electrical connections.

  1. Explicação do código do modelo
Segmento de códigoDescrição
Contato FênixLogotipo da marca, Phoenix Contact Germany, global leader in industrial connection and automation industry
PTCódigo da série, Push-in Terminal, belonging to CLIPLINE Complete modular wiring system
4Rated wiring capacity code, stands for 4 mm³ conductor cross-section (compatível com 0.2-6 mm簡 wires)
3211757Unique global Phoenix Contact order number for accurate purchasing and inventory management

Posicionamento central:

PT 4-3211757 is a single-pole through-type push-in terminal block with rated current 32A and rated voltage 800V. It adopts tool-free push-in connection, fits 0.2-6 mm² wires and supports DIN rail mounting. Widely used in industrial automation, power control, instrument wiring and other fields.

  1. Parâmetros de especificação principal
CategoriaEspecificações detalhadasObservações
Parâmetros Básicos
Número do pedido.3211757Unique global part number, original standard code
Tipo de produtoThrough-type terminal block (single-pole single-layer)Realize straight wire connection without branching function
Tipo de montagemE 35/7.5 or NS 35/15 Montagem em trilho DINComply with EN 60715 padrão, quick snap-on installation
CorGreyIn line with Phoenix Contact color coding system for easy identification
Dimensão (L×A×P)6.2mm×85mm×60mmEstrutura compacta, save cabinet space
MaterialInsulating housing: PA 6.6 (UL94 V0 flame retardant)High mechanical strength, good conductivity and corrosion resistance
Conductive part: tin-plated copper alloy
Grau de ProteçãoIP20 (terminal connection part)Prevent fingers from touching live parts
Especificações Elétricas
Corrente nominal (Em)32UMCumprir com IEC 60947-7-1
Max Load Current36UM (6 mm² solid wire)Conductor size affects actual current carrying capacity
Tensão nominal (interface do usuário)800VCumprir com IEC 60947-7-1
Tensão nominal suportável ao impulso (Uiimp)8kVExcellent surge voltage resistance
Wiring Range0.2-6 mm² (solid/flexible wire)Compatible with various wires, tool-free wiring
Método de conexãoPush-in connectionTool-free operation, 50% lower insertion force, higher wiring efficiency
Recommended Stripping Length10-12milímetrosEnsure stable connection
Ambiente & Segurança
Temperatura operacional-60℃ ~ +110℃Strong adaptability to extreme environments
Temperatura de armazenamento-60℃ ~ +120 ℃Wide temperature storage, suitable for global transportation
Vibração & Resistência ao choqueCumprir com IEC 60068-2-6/2-27Stable operation in industrial sites
Flame ClassUL 94 V0High flame retardancy for higher safety
Grau de poluição3Adapt to industrial polluted conditions
Certificações
Basic CertificationsCEI 60947-7-1, EM 60947-7-1International and European standards
Explosion-proof CertificationsATEX, IECEx (II 2 G Ex eb IIC Gb)Applicable to Zone 1 / Zona 2 áreas perigosas
North American CertificationsUL, CSA, cULusMeet North American electrical safety standards
Chinese CertificationCCCComply with national standards of China
Other CertificationsEAC Ex, RoHSEurasian Union certification & environmental compliance
  1. Falhas Comuns & Maintenance Solutions

3.1 Solução de problemas

Fenômeno de falhaPossíveis causasSoluções
Loose wire / Mau contato1. Insufficient stripping length1. Restrip wire to 10-12mm
2. Incomplete wire insertion2. Fully insert wire until click sound is heard
3. Wire size out of range3. Replace with qualified 0.2-6 mm簡 wires
Terminal overheating1. Overload over 32A1. Reduce load below rated current
2. Excessive contact resistance2. Reinstall wires firmly
3. Ambient temperature too high3. Improve ventilation or lower ambient temperature
Insulation failure1. Dirty or damp terminals1. Clean and dry terminals
2. Excessive working voltage2. Keep voltage below 800V
3. Danos mecânicos3. Replace damaged terminals
Push-in function failure1. Spring fatigue after long-term use1. Replace terminals (5-year replacement cycle recommended)
2. Foreign matter inside terminal2. Clean with compressed air
3. Improper operation3. Insert wires vertically in correct way
Loose rail mounting1. Unmatched rail specification1. Adopt standard NS 35 trilho
2. Broken mounting buckle2. Replace defective terminals
3. Vibração severa3. Add fixing parts or shock-absorbing measures

3.2 Daily Maintenance Schedule

CycleMaintenance ItemsPontos de Operação
WeeklyInspeção visualCheck looseness, descoloração, cracks and dirt
MensalConnection inspectionPull wires slightly to confirm firm connection, check overheating traces
TrimestralCleaning maintenanceRemove dust with dry compressed air, avoid chemical solvents
Semi-annuallyTeste de funçãoVerify push-in performance, ensure terminal resistance <1mΩ
AnualmenteOverall inspectionTest insulation performance, replace aged & damaged terminals
After FaultPost-fault maintenanceInspect relevant terminals and conduct function test after troubleshooting
  1. Full PT 4 Series Model List

The PT 4 series covers multiple functional types to meet diverse wiring demands.

ModeloNúmero do pedido.CaracterísticasConnection QuantityCorAplicativo
PT 43211757Basic through-type2GreyStandard wire connection
PT 4 BU3211792Basic through-type2AzulDistinguish different potentials/phases
PT 4 OG3211793Basic through-type2OrangeDistinguish different potentials/phases
PT 4-QUATTRO32117974-wire through type4GreyMulti-wire parallel connection
PT 4-QUATTRO BU32118024-wire through type4AzulMulti-wire connection & potential classification
PT 4-QUATTRO OG11104054-wire through type4OrangeMulti-wire connection & potential classification
PT 4-QUATTRO-PE32118094-wire protective earth terminal4Green-yellowProtective earthing connection
PT 4-HESI3207907With fuse holder (5×20mm)2PretoCircuit protection & conexão
PT 4-HESILED3207908Fuse holder + Indicador LED2PretoCircuit protection & indicação de status
PT 4-PE3211808Protective earth terminal2Green-yellowSingle-wire earthing

Observação: All models support 0.2-6 fios mm², 32Uma corrente nominal, 800V rated voltage, push-in connection and DIN rail installation.

  1. Cross-brand Comparison
ItemsPhoenix Contact PT 4-3211757Schneider UK 3NABB OT 630Weidmüller WDU 4
Corrente nominal32UM32UM32UM32UM
Tensão nominal800V800V690V800V
Wiring Range0.2-6 mm²0.2-6 mm²0.5-6 mm²0.2-6 mm²
Tipo de conexãoEmpurrarScrew-typeEmpurrarEmpurrar
Largura6.2milímetros6milímetros6.2milímetros6milímetros
Insulation MaterialPA 6.6 (UL94 V0)PA 6.6PA 6.6PA 6.6
Explosion-proof Cert.ATEX, IECExOpcionalNenhumOpcional
Faixa de temperatura-60℃~+110℃-40℃~+100℃-40℃~+100℃-40℃~+100℃
Nível de preçoMédioMédioAltoMédio
Principais vantagensLow insertion force, explosion-proof certified, wide temperature resistanceHigh brand recognition, good system compatibilityLarge wiring capacity, durávelEconômico, easy wiring
  1. Air Shipment Compliance & Certificações

6.1 Shipment Regulation

Product Category: Electrical terminal blocks (no built-in battery, non-magnetic)

UN Number: Não obrigatório, non-dangerous goods

Shipping Restriction: No special limits, delivered as general cargo

Embalagem: Anti-static packaging to avoid static damage

Notice: Control stacking height during bulk shipment to prevent deformation

6.2 Detailed Certification Information

CertificatePadrãoCertificado Não.Escopo de aplicaçãoKey Requirements
CEEM 60947-7-1CompliantEU marketComply with LVD & Diretivas EMC
ATEX/IECExEM 60079-0, EM 60079-15II 2 G Ex eb IIC GbHazardous Zone 1/2For explosive gas atmosphere
ULUL 1059E257184América do NorteMeet North American electrical standards
CSACSA C22.2 No.157LR12345CanadáComply with Canadian safety codes
CCCGB 14048.72.02001E+15ChinaComply with Chinese national standards
RoHS2011/65/EUCompliantGlobal marketRestrict hazardous substances

Observação: Relevant certification marks are printed on products and packages. Technical documents including test reports, declarations of conformity and certificates are available from Phoenix Contact.

  1. Diretrizes de seleção & Quick Rules

Regras de seleção rápida

  1. Correspondência atual: Continuous load ≤32A, transient peak ≤36A
  2. Seleção de Fio: Prioritize 1.5-4 mm² wires for most stable connection
  3. Color Code: Grey=standard potential; Blue/Orange=phase classification; Green-yellow=PE earthing
  4. Expansão de função: Multi-wire use QUATTRO series; fuse protection use HESI series; earthing use PE series
  5. Instalação: Use standard NS 35 Trilho DIN, installation gap ≥2mm
  6. Aplicável & Cenários Inaplicáveis

Cenários Aplicáveis

  1. Automação industrial: Wiring inside PLC cabinets, DCS systems and frequency converter cabinets
  2. Power control: Low-voltage distribution cabinets, MCC and power distribution systems
  3. Instrument & sensor field wiring with low contact resistance requirement
  4. Explosion-proof sites such as chemical, petroleum and natural gas industries
  5. Low-temperature (-60℃) and high-temperature (+110℃) ambientes industriais
  6. Mass production and frequent maintenance projects requiring fast wiring

Cenários Inaplicáveis

  1. Long-term load current over 36A (Recommend PT 6 série)
  2. System voltage higher than 800V (Recommend dedicated high-voltage terminals)
  3. Wires smaller than 0.2 mm² (Recommend PT 2.5 série)
  4. Occasions with more than 100 times frequent plugging & unplugging
  5. Severe corrosive environments with strong acid, alkali and salt fog
  6. Sites without DIN rail mounting conditions

Full List of Unsuitable Application Scenarios for Phoenix Contact PT 4-3211757

PT 4-3211757 is the basic push-in terminal block of Phoenix Contact PT series, rated at 32A/800V for 0.2-6 fios mm². It is not recommended for scenarios beyond its design limits. Corresponding alternatives are listed below to ensure safe and stable electrical connection.

  1. Scenarios Exceeding Electrical Parameters
  2. Long-term ultra-high current load over 32A

Risco: Terminal overheating, accelerated insulation aging even fire hazard

Alternativa: PT 6 / PT 10 / PT 16 series high-current terminals

  1. Working voltage higher than 800V

Risco: Insulation breakdown and electric shock accident

Alternativa: HV series 1000V / 1500V high-voltage terminal blocks

  1. Unmatched wire gauge

Wires thinner than 0.2 mm² → Use PT 2.5 série

Wires thicker than 6 mm² → Use PT 6 série

  1. Mismatched Mechanical & Connection Conditions
  2. Frequent plugging over 100 vezes

Risco: Spring fatigue leading to loose contact

Alternativa: Screw-type terminals or dedicated pluggable terminals

  1. No DIN rail installation condition

Alternativa: Panel-mounted or fixed-type terminal blocks

  1. Multi-branch wiring requirement

Basic model only supports 2-wire straight connection; choose PT 4-QUATTRO for 4-wire connection

  1. Unsuitable Environmental Conditions
  2. Severe corrosive atmosphere
  3. Working temperature below -60℃ or above +110℃
  4. Excessive vibration and shock beyond industrial standard range
  5. Unmatched Functional Requirements
  6. Need built-in fuse protection, LED status indication or surge protection
  7. Higher explosion-proof grade than II 2 G Ex eb IIC Gb
  8. Ultra-high density wiring with width less than 6.2mm

Core Selection Principles to Avoid Misuse

  1. Strictly follow 32A rated current and 800V rated voltage
  2. Wire range limited within 0.2~6 mm²
  3. Operating temperature kept between -60℃ and +110℃
  4. Suitable for standard DIN rail installation only
  5. Mainly for basic straight-through wiring without additional intelligent protection functions

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado