Mitsubishi AJ65SBTB1-32D Compact Remote Input Module - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 Mitsubishi AJ65SBTB1-32D Compact Remote Input Module - Contator,disjuntor,sensor,Codificador,CLP,Conversor

CLP/

Mitsubishi AJ65SBTB1-32D Compact Remote Input Module

AJ65SBTB1-32D is a Mitsubishi MELSEC CC-Link compact remote DC digital input module Model Code Definition AJ65: CC-Link remote I/O module series SBTB1: Compact remote I/O main body 32: 32 I/O points D: Entrada Digital (Entrada CC) Key Specifications Item Parameter Network CC-Link Ver.1/2 Type Remote DC digital input module Points 32 input points Occupied stations ...

  • Detalhes do produto

AJ65SBTB1-32D is a Mitsubishi MELSEC CC-Link compact remote DC digital input module

  1. Definição de código de modelo

AJ65: CC-Link remote I/O module series

SBTB1: Compact remote I/O main body

32: 32 Pontos de E/S

D: Entrada Digital (Entrada CC)

  1. Especificações principais
ItemParâmetro
RedeCC-Link Ver.1/2
TipoRemote DC digital input module
Pontos32 pontos de entrada
Occupied stations1 estação
Tensão de entrada nominalCC24V
Corrente de entradaAprox.. 7mA por ponto
Input response time1.5EM (DESLIGADO→LIGADO / LIGADO→DESLIGADO)
Input polaritySink/Source compatible (works with both NPN and PNP sensors)
IsolamentoIsolamento do optoacoplador
Fonte de alimentação do móduloCC24V; Module power consumption approx. 45mA
ON threshold≥14VCC / ≥3.5mA
OFF threshold≤6VDC / ≤1.7mA
Dimensões geraisW179 × H50 × D40 mm
Peso0.25 kg
TerminaisBloco terminal de parafuso M3
Classe de proteçãoIP2X
  1. Cenários de aplicação

Remote sensor signal acquisition for production lines: sensores fotoelétricos, interruptores de proximidade, interruptores magnéticos, pushbutton signals

Distributed I/O architecture to reduce bulk hardwiring from control cabinets to field devices via CC-Link bus networking

Compatible with Mitsubishi Q-series, FX3U/FX5U PLCs equipped with CC-Link master station

  1. Distinção de modelo (Frequently Confused Models)
  2. AJ65SBTB1-32D: Versão padrão, 1.5resposta da senhora, 32DE
  3. AJ65SBTB1-32D1: Versão de alta velocidade, 0.2resposta da senhora, 32DE, preferred for high-frequency sensors
  4. AJ65SBTB1-32T: 32-point transistor output module
  5. AJ65SBTB1-32DT: 16-input +16-output mixed I/O module

Lifecycle note: AJ65SBTB1-32D is discontinued. Only stock or used units available. Para novos projetos, AJ65SBTB1-32D1 is the preferred replacement. Same mounting dimensions and terminal definitions; only faster response speed, nenhuma modificação do programa necessária.

  1. Instalação & Diretrizes de fiação
  2. Fonte de energia: Independent DC24V supply for module itself; sensors also use DC24V signal
  3. CC-Link bus: DA/DB cables; 110Ω terminating resistors fitted at both ends of the bus
  4. Common terminals: 8 points per common group, supports NPN/PNP. Keep unified polarity during wiring
  5. Aterramento: Reliable earthing on FG terminal to reduce bus interference
  6. Station number setting: DIP switches on module body to set CC-Link station number
  7. Solução de problemas de falhas comuns
  8. RUN indicator off: Check DC24V supply, polarity and internal fuse
  9. ERR indicator flashing: CC-Link communication failure. Inspect DA/DB wiring, terminating resistors, duplicate station numbers, shield earthing
  10. No signal at input channel: Verify sensor power supply and common polarity; measure terminal voltage with multimeter; check for damaged optocoupler channel
  11. Acionamento de sinal falso: Interferência de cabo, use shielded cable; check response time. Para cabos longos, select D1 high-speed variant
  12. Alternative Selection List
  13. Substituição direta (mesmo tamanho & terminais): AJ65SBTB1-32D1 (Recomendado para novos projetos)
  14. Domestic compatible CC-Link 32DI remote I/O: Inovação, Inwell CC-Link remote input modules (verify CC-Link version and register mapping)
  15. Upgrade to CC-Link IE Field bus: NZ-series remote I/O (hardware architecture completely different; PLC program rewrite required)
  16. Referência do Código HS

8537101100 (Programmable controller digital input module, for customs declaration only; subject to customs final judgement)

CC-Link Master Station Parameter Configuration (for AJ65SBTB1-32D, Remote I/O Station, ocupa 1 estação)

Master module: QJ61BT11N (Q-series); Software de programação: GX Works2; AJ65SBTB1-32D = Remote I/O Station, ocupa 1 estação, 32-point RX input, no RY output and no RW registers.

Master station fixed station number: Station 0. Slave AJ65SBTB1-32D station number set via DIP switch: 1~64. Station 1 is used in this example.

  1. Hardware DIP Switch (Set AJ65SBTB1-32D first!)
  2. Station number DIP switch: Binary DIP switch for station address (por exemplo. Station 1 = 00000001)
  3. Baud rate DIP switch: Must match master station baud rate

000 → 156kbps

001 → 625kbps

010 → 2.5Mbps (most commonly used on site)

011 → 5Mbps

100 →10Mbps

Fit 110Ω terminating resistors at both ends of the bus

  1. GX Works2 Q-series CC-Link Master Basic Parameters

Caminho: Project Navigator → Parameters → Network Parameters → CC-Link

ItemSetting ValueObservações
Modelo de móduloQJ61BT11NMaster station module
Start I/O Address0000 (modify according to actual slot)Module I/O address
Master Station No.0CC-Link master fixed at station 0
ModoRemote Net(Ver.1 Mode)AJ65SBTB1-32D is Ver.1 compatible remote I/O
Total Connected Stations1For single AJ65SBTB1-32D network; update for multiple slaves
Velocidade de comunicação2.5MbpsMust match slave DIP baud rate
Retry Count3Padrão
Standby MasterNenhumStandard single-master system
Scan ModeAssíncronoPadrão

Station Information (Crítico!)

Clique [Station Information], add Station No.1:

ItemContexto
Estação nº.1DIP station number of AJ65SBTB1-32D
Tipo de estaçãoRemote I/O Station⚠️ NOT Remote Device Station!
Occupied Stations1AJ65SBTB1-32D fixed as 1 estação
RX(Remote Input)32 pontosX0~X1F (corresponds to 32DI)
RY(Remote Output)0 pontosThis module has inputs only, no outputs
RWw/RWr0 palavrasRemote I/O stations do not use registers

Remote I/O station soft element mapping rule:

Station1: RX0~RX1F correspond to the 32 DI channels of AJ65SBTB1-32D

PLC internal soft elements for master station: RX mapped to PLC X addresses (auto-refreshed by GX Works)

  1. Soft Element Refresh Mapping (QJ61BT11N)

CC-Link automatic refresh:

RX: Remote input → PLC internal X

RY: PLC output → Remote module output

RWw: PLC writes to remote registers

RWR: Remote registers read into PLC

AJ65SBTB1-32D (Station 1)

RX0~RX1F (32pedaço) = 32 DC input channels of the module

Exemplo: Sensor ON → RXn=ON; read RX bit directly in program.

  1. FX5U + FX5-CCL-MS (FX5U CC-Link Master, GX Works2/3)

FX5U with FX5-CCL-MS master card can connect AJ65SBTB1-32D

  1. Project → Parameters → CC-Link Parameters, Master type: Master station, Ver.1 mode
  2. Add station entry for Station 1: Remote I/O Station, ocupa 1 estação, RX=32, RY=0
  3. Soft element refresh: RX mapped to FX5U X or M (customizable refresh address)

FX5U built-in Ethernet CC-Link IE Field Basic cannot directly connect old AJ65SBTB1-32D. This classic CC-Link uses RS485 bus and requires FX5-CCL-MS module.

  1. Download & Etapas de comissionamento
  2. Complete all parameter settings, clique [Verificar], confirm no errors;
  3. Escrever [Parâmetros + Programa] to PLC; PLC reset;
  4. Power up remote modules with DC24V first, then power up PLC master station;
  5. Observe os indicadores:

M/S: Master steady ON; CORRER: Slave steady ON;

ERR off = Communication normal; ERR flashing = bus fault;

  1. Online monitor RX soft elements; trigger sensors and verify corresponding RX bits turn ON/OFF.
  2. Erros Comuns
  3. ❌ Wrong station type: selected as Remote Device Station → communication failure; must use Remote I/O Station
  4. ❌ Baud rate mismatch between master and slave
  5. ❌ Missing terminating resistors, random disconnection over long cables
  6. ❌ Duplicate station numbers, frequent in multi-slave networks
  7. ❌ Ver.2 mode enabled; old AJ65SBTB1-32D is Ver.1 compatible, use Remote Net Ver.1 Mode by priority
  8. Sample Program (ST / Ladder compatible)

Directly monitor RX0~RX1F, no special communication instruction required, CC-Link auto cyclic refresh.

Exemplo: LD RX0 reads channel 0 input of AJ65SBTB1-32D.

Optional extensions available upon request:

  1. Screenshot-style GX Works2 CC-Link parameter setup guide
  2. Batch parameters for multiple AJ65SBTB1-32D network (Station1, Station2, Station3…)
  3. Communication fault code (ERR lamp) reference table
  4. Ladder example to map RX to internal M relays for easier programming

CC-Link ERR Lamp + QJ61BT11N Fault Code Reference Table (For AJ65SBTB1-32D)

Two sections: Quick LED Indicator Diagnosis (On-site check) + Hex Fault Codes read from GX Works Diagnosis (Precise troubleshooting)

Mestre: QJ61BT11N; Escravo: AJ65SBTB1-32D

  1. LED Status Quick Reference (Master QJ61BT11N ERR Lamp)
Master ERR LampDescrição da falhaSolução de problemas
DESLIGADOCommunication normal–
Constantemente ligadoAll stations communication failureBus breakage, DA/DB reversed, dual master conflict, parameter error, baud mismatch, faltando resistor de terminação
PiscandoPartial slave fault, faulty station existsSingle/multiple slave offline, duplicate station number, slave power off, slave hardware damage

Slave AJ65SBTB1-32D L.ERR Indicator

Slave L.ERR LampDescrição da falhaSolução de problemas
DESLIGADOCommunication normal–
Constantemente ligadoSlave communication errorStation number out of range, bus broken, power supply abnormal
Regular periodic flashingDIP switch modified under power (station/baud)Desligar, reset DIP switch, repower
Irregular random flashingNoise interference / faulty terminating resistor110惟 resistors at both bus ends, shield earthing, danos no cabo, parallel power cable interference

PW lamp OFF: No DC24V supply to slave, check power terminals and fuse first.

L.RUN lamp OFF: Data link not established; master cannot detect this slave station.

  1. QJ61BT11N Master Hex Fault Codes (Read via GX Works CC-Link Diagnosis)
Código de falha(HEX)Nome da falhaCausaAção
B823Remote control mode errorIncorrect master mode settingSet network parameter to Remote Net(Ver.1 Mode). AJ65SBTB1-32D does not support Ver.2 extended mode
B983 / B984Invalid module typeMode incompatibility between master and slaveOld AJ65SBTB1-32D is Ver.1 remote I/O; disable Ver.2 mode
BA1BAll stations failureWhole bus communication interruptionDA/DB wiring, 110惟 terminators, taxa de transmissão, quebra de cabo
BBC2Station number setting errorStation number out of range or wrong station typeStation type must be [Remote I/O Station], not Remote Device Station; station range 1~64
BBC5Duplicate master station (multi-master conflict)2 masters on the same CC-Link busCheck bus and keep only one master module
BD85Master hardware failureQJ61BT11N module damageCiclo de energia, replace master module if fault persists
BFFECPU watchdog timeoutCommunication error between PLC CPU and master moduleCheck QCPU backplane, module installation, PLC reset
C92EBaud rate mismatchMaster baud differs from slave DIP settingSet master baud equal to AJ65SBTB1-32D DIP baud
C932Duplicate station number conflictTwo slaves with identical station DIP settingCheck each module DIP and assign unique station number
C940Data link stopBus break / interference / missing terminatorCheck DA DB wiring, shield earthing, terminating resistors
  1. Q-series CC-Link Special Relay SW (Monitor in GX Works)

Identify offline station quickly via SW registers

  1. SW0080~SW0083: Link error bits, bit maps to station number. ON = fault at that station

SW0080 bit0 = Station1 fault; bit1 = Station2 fault, and so on

  1. SW006B: Detailed error type

0: Normal

1: Transmission line fault

2: Parameter error

3: CRC error (interferência eletromagnética)

4: Timeout error (slave no response)

5: Abort error

6: Setting error

  1. On-site Troubleshooting Sequence (AJ65SBTB1-32D)
  2. Check slave PW lamp: OFF → inspect DC24V supply
  3. Check slave L.RUN / L.ERR lamp
  4. Open GX Works → CC-Link Diagnosis, read fault code + SW0080 to locate faulty station
  5. Verificar: station number, taxa de transmissão, station type (Remote I/O Station)
  6. Check DA/DB polarity, 110Ω terminators at both bus ends
  7. Single-point earthing for shield; avoid both-end earthing to prevent ground loop
  8. Separate CC-Link cable away from power cables to reduce interference
  9. Common Pitfall Summary
  10. Remote I/O Station mistakenly selected as Remote Device Station → BBC2 station type error, ERR flashing
  11. Master Ver.2 mode enabled, old AJ65SBTB1-32D incompatible → B983 invalid module type
  12. Terminating resistor fitted only on one end → random flashing, intermittent disconnection
  13. DA DB wires reversed, entire bus down, master ERR steady ON
  14. Modify DIP switches while powered on, slave L.ERR flashes periodically; power cycle to recover

Mitsubishi AJ65SBTB1 Series (CC-Link Compact Remote I/O, Screw Terminal Block, all discontinued, 1 station occupancy)

Suffix definition

D: Entrada digital CC; D1: High-speed Input; D5: 5V Input

T: Sink transistor output; T1: High-speed transistor output; TE1: Saída do transistor de origem

DT: Mixed Input+Output; K: Special common terminal specification

All modules in this series are Remote I/O Stations (not Remote Device Stations), CC-Link Ver.1 compatible

  1. Pure DC Input Modules (DE)
ModeloPontosBrief Specification
AJ65SBTB1-8D8DECC24V, standard response 1.5ms, NPN/PNP common terminal
AJ65SBTB1-16D16DECC24V, standard response 1.5ms
AJ65SBTB1-16D116DECC24V, high-speed 0.2ms
AJ65SBTB1-32D32DECC24V, standard response 1.5ms (your target model)
AJ65SBTB1-32D132DECC24V, high-speed 0.2ms, direct compatible replacement for 32D
AJ65SBTB1-32D532DEDC5V input, special signal acquisition for legacy projects
AJ65SBTB1-32KD32DECC24V, special common terminal layout
  1. Pure Transistor Output Modules (FAZER)
ModeloPontosBrief Specification
AJ65SBTB1-8T8FAZERDC24V sink transistor, 0.5Um por ponto
AJ65SBTB1-8T18FAZERHigh-speed sink transistor output
AJ65SBTB1-8TE8FAZERSaída do transistor de origem
AJ65SBTB1-16T16FAZERDC24V sink transistor
AJ65SBTB1-16T116FAZERHigh-speed sink transistor output
AJ65SBTB1-32T32FAZERDC24V sink transistor output
AJ65SBTB1-32T132FAZERHigh-speed sink transistor output
AJ65SBTB1-32TE132FAZERSaída do transistor de origem
  1. Módulos de E/S mistos (DI+DO)
ModeloConfiguração de E/SBrief Specification
AJ65SBTB1-16DT8D+8CEntrada DC24V + sink transistor output
AJ65SBTB1-16DT18D+8CVersão de alta velocidade
AJ65SBTB1-16DT28D+8CPositive common version
AJ65SBTB1-16DT38D+8CNegative common version
AJ65SBTB1-32DT16D+16C16-in 16-out, modelo padrão
AJ65SBTB1-32DT216D+16CRevised common terminal spec
AJ65SBTB1-32DT316D+16CImproved revision
AJ65SBTB1-32DTE116D+16CSaída do transistor de origem
AJ65SBTB1-32KDT216D+16CSpecial common terminal
AJ65SBTB1-32KDT816D+16C12V I/O, special legacy project

Distinguish other family series (AJ65SBTB2 / AJ65SBTB32 / AJ65SBTC connector type, NOT SBTB1 series)

Frequently confused during procurement, not part of SBTB1 series, reference only

  1. AJ65SBTB2: Relay output R, analog A modules

AJ65SBTB2-8R, AJ65SBTB2-16R (saída de relé); AJ65SBTB2-8A, 16A analog

  1. AJ65SBTB32: Compact small terminal block

AJ65SBTB32-8DT / 8DT2, AJ65SBTB32-16DT / 16DT2, AJ65SBTB32-16DR (mixed relay)

  1. AJ65SBTC: Quick connector type (not screw terminals)

AJ65SBTC1-32D, AJ65SBTC1-32T, AJ65SBTC1-32DT, field plug wiring, different form factor from SBTB1

Notas de seleção

  1. All AJ65SBTB1 series are discontinued. Not available for new project purchase, apenas estoque / used units.
  2. Mesmas dimensões de montagem: same point count D/D1, T/T1, DT/DT modules support direct drop-in replacement with no program modification.
  3. Station type: Must select [Remote I/O Station] in GX Works parameter; fixo 1 occupied station.
  4. Analog modules are not in SBTB1 series: models AJ65SBT-64AD, AJ65SBT2B-64AD etc.

Anterior:

Deixe uma resposta

Deixe um recado