Modelo Completo: EMG 17-REL/KSR-24/21-21-LC
✅ Basic Information
Número da peça: 2940391
Tipo de produto: DIN-rail mounted electromagnetic relay module (built-in miniature relay soldered, relay core non-removable)
Série: EMG 17-REL
Origem: Alemanha
Código HS: 85364190
Conexão: Screw terminal M3
Dimensões: 17.5(C) ×75(H) ×62.5(D) milímetros
Embalagem: 10 peças por caixa, minimum order 1 computador
⚙️ Core Electrical Parameters
Fornecimento de bobinas: 24V CA/CC universal, typical current 18mA, power consumption 0.43W
Configuração de contato: 2 changeover contacts DPDT (2C)
Material de contato: AgNi silver nickel, suitable for medium-load applications
Rated Continuous Current: 5UM; maximum inrush switching current 6A
Tensão máxima de comutação: 250V CA/CC
Vida Mecânica: aprox.. 5operações ×10⁷
Temperatura operacional: -20℃ ~ +40 ℃; Temperatura de armazenamento: -20℃ ~ +70 ℃
Isolamento: Basic isolation between input and output, with status LED and surge suppression circuit
Wiring Cross-section: 0.2–4mm² solid wire / 0.2–2.5mm² flexible wire
📌 Terminal Definition
A1/A2: Fonte de alimentação da bobina (24V CA/CC)
11, 12, 14: 1primeiro contato de mudança
21, 22, 24: 2segundo contato de mudança
📋 Application Scenarios
PLC/controller signal isolation, low-side control of high-power loads, válvulas solenóides, contactors and indicator light circuits.
Recurso: Integrated soldered construction, relay core cannot be replaced separately; interchangeable pluggable models belong to the RIF series.
🔁 Alternative Reference (Compatible Equivalents)
Same brand alternative: RIF-1-RSC-24DC/2X21 (pluggable relay core, manutenção mais fácil, same width 17.5mm)
Alternativa doméstica: 17.5mm width relay module, 24V CA/CC, 2 contatos de mudança, tipo de terminal de parafuso
📎 Certifications
cULus, EAC, CE; compatível com EN 61810-1, EN50178
Full List of Contato Fênix EMG-REL Relay Modules
Observação: EMG-REL includes 3 sub-width series: EMG10-REL (10milímetros), EMG17-REL (17.5milímetros, convencional), EMG22-REL (22.5milímetros). All adopt soldered built-in relays (non-removable relay core), screw terminals and DIN rail mounting.
KSR = standard monostable electromagnetic relay; SG = latching relay; G = DC-only coil; W = AC-only coil; LC = LED indicator + surge suppression circuit
- EMG 17-REL / 17.5milímetros (Mais Comum, incluindo 2940391)
| Número da peça. | Modelo Completo | Tensão da bobina | Contact Spec | Observações |
| 2940391 | EMG 17‑REL/KSR‑24/21‑21‑LC | 24V CA/CC | 2 changeover (2C) | ✅ Item you enquired, AgNi, com LED & suppression circuit |
| 2940430 | EMG 17‑REL/KSR‑W230/21‑21‑LC | 230V e | 2 changeover (2C) | AC-only version, dual contacts |
| 2953854 | EMG 17‑REL/KSR‑24/21 | 24V CA/CC | 1 changeover (1C) | Single changeover, simplified version without LC |
| 2947420 | EMG 17‑REL/KSR‑12/21 | 12V CA/CC | 1 changeover (1C) | 12V universal model |
| 2947653 | EMG 17‑REL/KSR‑230/21 | 230V CA/CC | 1 changeover (1C) | 230V universal, dual A2 terminal |
| 2946353 | EMG 17‑REL/KSR‑230/21/SO54 | 230V CA/CC | 1 changeover (1C) | SO54 special contact configuration, reinforced insulation |
| 2949994 | EMG 17‑REL/KSR‑G24/SO38 BK | 24Em DC | 1 normalmente aberto (NÃO) | Carcaça preta, AgSnO₂, 80A inrush withstand, dedicated for lamp loads |
| 2946654 | EMG 17‑REL/SG‑B48/21/P | 48Em DC | 1 changeover (1C) | SG latching relay, with forward diode circuit |
- EMG 10-REL / 10mm Narrow Version (Cabinet Space Saving)
| Número da peça. | Modelo Completo | Tensão da bobina | Contact Spec | Observações |
| 2942108 | EMG 10‑REL/KSR‑G24/1‑LC | 24Em DC | 1 normalmente aberto (NÃO) | Com LED, AgNi for standard loads |
| 2941400 | EMG 10‑REL/KSR‑G60/1‑LC AU | 60Em DC | 1 normalmente aberto (NÃO) | AU gold-plated contacts, for low-current weak signals |
- EMG 22-REL / 22.5mm Wide Version (High Isolation / Built-in Transistor Drive)
| Número da peça. | Modelo Completo | Tensão da bobina | Contact Spec | Observações |
| 2951885 | EMG 22‑REL/KSR‑24/21 | 24V CA/CC | 1 changeover (1C) | Alto isolamento, 5kV dielectric strength, propósito geral |
| 2952350 | EMG 22‑REL/KSR‑G24/TRN35 | 24Em DC | 1 changeover (1C) | Built-in NPN transistor, direct drive by low-current PLC outputs, hybrid relay |
- Suffix Explanation for Model Selection
KSR: Standard monostable electromagnetic relay
SG: Latching relay (remains state after power loss)
G: DC-only coil
C: Bobina somente CA
LC: Indicador de status LED integrado + coil surge suppression circuit (diodo de roda livre / varistor)
/21: 1 contato de mudança (1C: 11/12/14)
/21-21: 2 contatos de mudança (2C: 11-12-14 & 21-22-24)
SO38 / SO54: Special contact material (AgSnO₂, suitable for lamp loads and high inrush current)
UA: Gold-plated contacts, weak signal and low-level circuits
TRN35: Built-in NPN pre-drive transistor
- Distinção Chave (Avoid Confusion with RIF Series)
EMG-REL: Relay soldered to base, non-replaceable relay core, cost-effective for fixed installation
RIF-REL / RIF-1: Plug-in replaceable relay core, separate base and relay, manutenção mais fácil, same width for replacement
Application Fields of Phoenix Contact EMG-REL Relay Modules
Posicionamento: Isolation relay for PLC / controller digital interfaces. Soldered integrated DIN-rail modules. Funções principais: low-voltage signal isolation, amplificação de sinal, level conversion, driving contactors, valves and indicator loads. Special variants (AU gold-plated, SO38 high-inrush, SG latching, TRN built-in transistor) for differentiated working conditions.
- Automação Industrial Geral (Mais Comum, incluindo 2940391)
Máquinas-ferramentas, equipamento de embalagem, linhas transportadoras, máquinas de moldagem por injeção, woodworking machinery and custom automation control cabinets
Isolation for PLC DO channels: PLC 24V DC outputs driving contactors, válvulas solenóides, indicator lights and sound-light alarms
Intertravamento de porta, comentários sobre status, fault alarm circuits, auxiliary start-stop control
Vantagem: LC versions with LED and suppression circuit suppress reverse EMF and protect PLC modules
- Automação Predial / AVAC
Air handling units, fresh air systems, unidades de fan coil, air dampers and water valve actuator control
Circuitos de iluminação, exaustores, bombas de água, BA system signal interfaces
230V AC coil variants directly work with mains circuits; narrow EMG10-REL saves cabinet space
- Tratamento de Água & Abastecimento Municipal de Água / Drenagem
Clean water tanks, sewage pump stations, chemical dosing systems, bar screens, valve actuation and liquid level alarm signal isolation
Stable screw wiring suitable for long continuous operation in humid cabinet environments
- Energia Renovável (VP, Armazenamento de energia, Energia Eólica)
Inverter cabinets, caixas combinadoras, auxiliary control for box-type transformers, fault alarm and status dry contact upload
Signal isolation to prevent strong electrical interference to acquisition boards; for onshore power stations (No ATEX certification, RIF explosion-proof series for hazardous areas)
- Classificação Logística & Automação de Armazém
Sorters, transportadores de rolos, empilhadores, AGV control cabinets, high-frequency switching signals, brake control and solenoid valves for sorting chutes
Alta vida mecânica (up to 5×10⁷ operations) for frequent switching cycles
- Infraestrutura: Tunnel & Road Lighting, Estações de bombeamento
Controle de iluminação (SO38 models with AgSnO₂ contacts withstand high inrush current from incandescent and LED lamps, up to 80A inrush)
Remote start-stop control of fans and drainage pumps
- Equipamento de teste, Instrumentação & Equipamento Médico
AU gold-plated variants: Low contact resistance for mA-level weak signal switching, sensor signal switching and test fixtures; not suitable for high-power loads, gold layer may be damaged by arcing
- Outras aplicações
Control cabinet signal transfer, relay logic expansion, remote IO isolation, auxiliary dry contacts for fire alarm linkage
SG latching variants: retain switching state after power loss for state memory applications
✅ Selection Guide by Suffix
KSR standard type: General solenoid valves, contatores, luzes indicadoras (90% common applications, por exemplo. 2940391)
SO38 BK: Lamp loads, capacitive loads, alta corrente de partida
AU gold-plated: Weak signal, instrument and low-current test circuits
SG latching: State retention after power failure
TRN35 built-in transistor: Direct drive by low-current PLC outputs without external pre-resistor
⚠️ Not Suitable Applications
EMG-REL complies with Class A EMC standards, not designed for consumer electronics. It does not have forcibly guided contacts, cannot be used for PLd / PLe safety circuits (safety relays with forcibly guided contacts required). No ATEX certification, not permitted in explosive hazardous areas.
Working Principle of Phoenix Contact EMG-REL Relay Modules
EMG-REL is an integrated electromagnetic relay module. Base, relé eletromagnético, LED indicator and suppression components are assembled in one DIN-rail housing. The relay core is permanently soldered and non-pluggable. Fundamentally, it is an electromechanical contact relay for low-voltage control of high-voltage circuits, electrical isolation and signal conversion.
- Basic Electromagnetic Principle
- Coil Side (Control Terminals A1/A2)
When rated coil voltage (CC24V / CA24V / AC230V etc.) is applied to A1 and A2, excitation current flows through the coil and generates magnetic flux on the iron core. The magnetic force overcomes spring tension and pulls the armature.
Coil energized → Armature pulls in → Contacts switch
Coil de-energized → Magnetic field disappears → Spring resets → Contacts return to original position
AC/DC universal coil versions (como 2940391) have coil windings designed for both AC and DC supply. Pure DC (suffix G) and pure AC (suffix W) variants use different winding parameters.
- Contact Side (Load Terminals 11/12/14, 21/22/24)
Changeover contacts (1C / 2C) include normally closed (NC) e normalmente aberto (NÃO):
De-energized state: Terminal comum (11) connects to NC (12) and disconnects from NO (14)
Bobina energizada: Terminal comum (11) disconnects from NC (12) and connects to NO (14) to activate the external load (válvulas solenóides, bobinas do contator, indicator lights etc.)
- Principle of Built-in Auxiliary Components (LC suffix, 2940391 is LC version)
LC = LED indicator + coil surge suppression circuit
LED status indicator: Wired parallel to the coil. Lights up when coil is powered to visually indicate drive signal presence. Integrated current-limiting resistor matched to rated voltage.
Surge suppression circuit (diodo de roda livre / varistor):
Relay coils are inductive loads and produce high reverse EMF upon de-energization, which may damage PLC output chips.
Bobinas CC: Usually use freewheeling diodes to dissipate inductive energy
Bobinas CA: Use varistor or RC snubber circuits to suppress AC voltage spikes
Models without LC suffix have no indicator or suppression; external surge protection must be added.
- Differentiated Principle of Special Sub-models
- SG Latching Version (EMG…SG)
Not conventional monostable relays. Permanent magnet inside:
Forward pulse power → Contacts close and stay latched after power removal
Reverse pulse power → Contacts reset and stay open after power removal
No continuous power required to maintain state, only pulse signal for switching, baixo consumo de energia.
- TRN35 Built-in Transistor Version (EMG…TRN35)
NPN pre-drive transistor integrated before coil: Low-current PLC signal drives the transistor first, then the transistor energizes the relay coil. Suitable for PLC channels with weak drive capacity.
- AU Gold-plated Contact Version
Gold plating on contact surface reduces contact resistance for mA-level weak signal switching. Not for heavy loads; gold plating is vulnerable to arc damage under high current.
- SO38 (AgSnO₂ Contacts)
Tin oxide silver contact material, arc-resistant and withstands high inrush surges, dedicated for lamp and capacitive loads to prevent contact welding.
- Electrical Isolation Logic
Basic insulation separates the coil control circuit and load contact circuit. It isolates PLC low-voltage side from high-voltage load side, blocks common-mode interference and prevents load-side faults from propagating into controller IO boards.
⚠️ Importante: This is only functional isolation. It is not a safety relay with forcibly guided contacts and cannot be used for PLe / PLd safety circuits.
- Simplified Working Flow (2940391, EMG17-REL/KSR-24/21-21-LC)
PLC digital output → 24V AC/DC supplied to A1/A2 → LED on, coil energized → Magnetic field pulls armature → Two changeover contacts switch synchronously → Solenoid valve / contactor energized
PLC output off → Coil de-energized → Suppression circuit dissipates residual coil energy → Spring resets contacts → Load de-energized
Contator,disjuntor,sensor,Codificador,CLP,Conversor



















NH42-63-318x560.png)