Mitsubishi S-T35 AC Magnetic Contactor - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 Mitsubishi S-T35 AC Magnetic Contactor - Contator,disjuntor,sensor,Codificador,CLP,Conversor

contator/

Mitsubishi S-T35 AC Magnetic Contactor

The S-T35 belongs to Mitsubishi MS-T Series, the upgraded successor model of S-N35, which is fully interchangeable with S-N35. It is an AC coil driven contactor widely used for three-phase motor start-stop and power circuit control in control cabinets. ✅ Core Specifications Frame size: 35 quadro, 3-pole main contacts AC-3 rating at 380/400V: 18.5kW, avaliado ...

  • Detalhes do produto

The S-T35 belongs to Mitsubishi Série MS-T, the upgraded successor model of S-N35, which is fully interchangeable with S-N35. It is an AC coil driven contator widely used for three-phase motor start-stop and power circuit control in control cabinets.

✅ Especificações principais

Tamanho do quadro: 35 quadro, 3-contatos principais do pólo

AC-3 rating at 380/400V: 18.5kW, rated operating current 35A

Tensão máxima do circuito principal: AC690V

Standard built-in auxiliary contacts: 2NÃO + 2NC (2a2b)

Dimensões gerais: 75(C) × 89(H) × 91(D) milímetros, weight 0.55kg

Montagem: DIN rail mounting or screw fixing; mounting hole positions fully compatible with S-N35

Classe de proteção: IP20

Resistência mecânica: 10 milhões de operações; Resistência elétrica (AC-3): aprox.. 1 milhões de operações

Coil voltage options (AC standard): CA24V, AC110V, AC220V, AC380V, AC400V, AC500V, 50/60hertz universais

✅ Model Naming Rule

`S-T35 + Coil Voltage`

Exemplo: S-T35 AC220V, S-T35 AC380V

Observação: S-T series is AC coil by default. DC coil version is SD-T series; não os misture.

✅ Comparison with S-N35

Corrente nominal do contato principal, power rating and auxiliary contact configuration are identical

Mounting dimensions and drilling holes are interchangeable for direct replacement

Optimized coil pull-in performance, wider voltage tolerance range and lower power consumption; officially recommended replacement for S-N35

✅ Matching Accessories

Módulos de contato auxiliar: UA, UN series (for contact expansion)

Supressor de surto: SZ series (varistor / RC absorber to suppress coil back EMF)

Relé de sobrecarga térmica: TH-T35 (motor overload protection, correspondido para 35 quadro)

Mechanical interlock unit: used for forward/reverse (invertendo) circuito

✅ Cenários típicos de aplicação

Máquinas de moldagem por injeção, fãs & bombas de água, linhas de produção, compressores de ar, Armários de controle HVAC, circuitos de energia de máquinas-ferramenta, direct start-stop control of three-phase asynchronous motors.

✅ Troubleshooting Guide

  1. Coil energized but no pull-in: Verifique a tensão da bobina, check loose wiring, test burnt coil
  2. Humming noise after pull-in: Alimentação de subtensão, dust/rust on iron core mating surfaces
  3. Severe main contact arcing & queimando: Overload beyond AC-3 rating, perda de fase, comutação frequente, damaged arc shield
  4. Unstable auxiliary contact signals: Oxidized contact surface, insufficient terminal tightening torque

✅ Cross-Brand Equivalent Models

Schneider LC1D38, Siemens 3RT2035, OMRON CJX2-32

  1. Terminal Definition of S-T35 (Standard 2a2b)

Circuito Principal (Incoming top, outgoing bottom)

L1, L2, L3 (Lado da fonte de alimentação); T1, T2, T3 (Lado de carga, connected to TH-T35 thermal relay input terminals)

Terminais de bobina

A1, A2: Bobina CA. Two A2 terminals are internally shorted for easy jumper wiring.

Contatos Auxiliares Integrados (2NÃO+2NC)

✅ Normally Open (NÃO): 13-14, 43-44

✅ Normally Closed (NC): 21-22, 31-32

Screw size: Main circuit M4; Bobina & auxiliary contacts M3.5

  1. Basic Self-Locking Wiring Diagram (S-T35 + TH-T35 Thermal Relay, Motor Start-Stop)

Circuito Principal

3-phase power → Circuit breaker → S-T35 L1/L2/L3 → S-T35 T1/T2/T3 → TH-T35 thermal relay input → Thermal relay output → Motor M

Circuito de Controle (AC220V example)

  1. L → Stop button (NC) → Botão Iniciar (NÃO) → S-T35 A1
  2. N → S-T35 A2
  3. Self-locking: Paralelo 13-14 (NÃO) across the start button
  4. Proteção contra sobrecarga: Wire TH-T35 95-96 (NC) in series into the control circuit; the coil will cut off when overload trips

Full Model List of MS-T Series

1) Non-Reversing Standard Models (S-T, your S-T35 is included)

ModeloCorrente AC-3 (380V)Potência do motor (380V)Contatos Auxiliares Padrão
S-T1011UM5.5kW1a1b
S-T1213UM7.5kW1a1b
S-T2018UM7.5kW1a1b
S-T2121UM11kW2a2b
S-T2525UM11kW2a2b
S-T3232UM15kW2a2b
S-T3535UM18.5kW2a2b
S-T5050UM22kW2a2b
S-T6565UM30kW2a2b
S-T8080UM37kW2a2b
S-T100100UM45kW2a2b

Coil suffix options: CA24V / AC110V / AC220V / AC380V; por exemplo. S-T35 AC220V

2) Invertendo (Avançar/Retroceder) Integrated Models (S-2×T with built-in interlock)

S-2×T10, S-2×T12, S-2×T20, S-2×T21, S-2×T25, S-2×T32, S-2×T35, S-2×T50, S-2×T65, S-2×T80, S-2×T100

3) Modelos Derivados Especiais (Mesmo quadro, different structure)

  1. DC Coil Version (SD-T, not interchangeable with S-T)

SD-T10, SD-T12, SD-T20, SD-T21, SD-T25, SD-T32, SD-T35, SD-T50, SD-T65, SD-T80, SD-T100

  1. Mechanical Latching Type (SL-T): Pull-in on energization, keep closed after power cut; only released when control circuit is disconnected

SL-T21, SL-T35, SL-T50, SL-T65, SL-T80, SL-T100

  1. Off-Delay Release Type (S-T□DL)

S-T12DL, S-T21DL, S-T35DL

  1. Matching Thermal Overload Relays (TH-T Series, frame-matched one-to-one)

TH-T18 (for T10/T12/T20)

TH-T25 (for T21/T25/T32)

TH-T35 (for S-T35)

TH-T50 (for T50)

TH-T65 (for T65/T80)

TH-T100 (for T100)

III. Magnetic Starters (Integrated contactor + relé térmico)

Non-reversing: MSO-T10, MSO-T12, MSO-T20, MSO-T21, MSO-T25, MSO-T32, MSO-T35, MSO-T50, MSO-T65, MSO-T80, MSO-T100

Invertendo: MSO-2×T10 …… MSO-2×T100

  1. Regra de nomenclatura de modelo (S-T□)

S = Contactor

T = MS-T Series (replaces old S-N series)

Numeral = Frame current rating (10/12/20/21/25/32/35/50/65/80/100)

Sufixo: Tensão da bobina (AC220V/AC380V); DL = Off-delay release; SL = Mechanical latch; SD = DC coil

  1. Cross-Replacement Table with Old S-N Series (Substituição direta)

S-T10 ↔ S-N10

S-T12 ↔ S-N12

S-T20 ↔ S-N20

S-T21 ↔ S-N21

S-T25 ↔ S-N25

S-T32 ↔ S-N32

S-T35 ↔ S-N35 (seu modelo)

S-T50 ↔ S-N50

S-T65 ↔ S-N65

S-T80 ↔ S-N80

S-T100 ↔ S-N100

Anterior:

Deixe uma resposta