Schneider EOCRSSD-30S Digital Motor Protector - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Schneider EOCRSSD-30S Digital Motor Protector - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

Schneider EOCRSSD-30S Digital Motor Protector

Model Code Interpretation Code Segment Description EOCR Series logo, motor protection relay series under Schneider (Former SAMWHA Korea) SS Basic series code, economical electronic overcurrent relay platform D Function upgrade code, Digital display version, different from LED indicator type of traditional SS series 30 Current specification code, rated protection current range: 3-30UM, built-in through-type CT for ...

  • Detalhes do produto

Interpretação de código modelo

Segmento de códigoDescrição
EOCRSeries logo, motor protection relay series under Schneider (Former SAMWHA Korea)
SSBasic series code, economical electronic overcurrent relay platform
DFunction upgrade code, Digital display version, different from LED indicator type of traditional SS series
30Current specification code, rated protection current range: 3-30UM, built-in through-type CT for direct wiring
SControl power supply code: universal wide voltage 24-240V AC/DC; Type W is dedicated for 380-440V AC

Posicionamento central:

EOCRSSD-30S is a compact digital comprehensive motor protection relay, featuring three core protections: sobrecarga, phase loss and stall. It is applicable for motors with current 3-30A and compatible with 24-240V wide-voltage control power supply.

  1. Parâmetros de especificação principal
CategoriaEspecificações detalhadasObservações
Parâmetros Básicos
Número do pedidoEOCRSSD-30S (Schneider SKU: 0015874)Standard universal model worldwide
Tipo de proteçãoElectronic overcurrent relay / Motor protectorReplace combination of traditional thermal relay and ammeter
Instalação35mm montagem em trilho DIN / Panel mountingEstrutura compacta, economia de espaço
Dimensão (L×A×P)56mm×78mm×120mmFully compatible with installation size of EOCR-SS series
Temperatura operacional-20℃ ~ 60℃Adapt to temperature difference changes in industrial environment
Especificações Elétricas
Current Protection Range3-30UM (direct wiring)External CT is required for current over 60A
Control Power Supply24-240V CA/CC (50/60Hz)Projeto de ampla tensão, fit for various control systems
Working Frequency50/60HzUniversal power frequency for global use
Output Contacts1NÃO + 1NC passive contacts95-96 (NC), 97-98 (NÃO)
Capacidade de contatoCA 250V/5A, DC 30V/5AMeet demands of conventional control circuits
Funções de proteção
Proteção contra sobrecargaAjustável (0.1~100s), support I²t inverse time characteristicSet via O-TIME parameter
Proteção contra perda de faseQuick action within 4 segundosTrigger when three-phase unbalance degree>20%
Stall ProtectionAdjustable startup delay (D-TIME), minimum 0.2s quick trippingSuitable for instantaneous protection during motor startup
Display Function7-segment LED digital tubeReal-time display of operating current and fault code
Modo de reinicializaçãoReinicialização manual (RESET button) / Electric resetEasy recovery after troubleshooting
Precisão & Confiabilidade
Measuring Accuracy±1%Higher than traditional thermal relay (±10%)
Tempo de respostaMínimo. 0.2é (proteção contra travamento)Effectively prevent motor damage
Fault RecordCheck the latest 3 registros de falhasConvenient for quick fault location
Classe de isolamentoClasse IIHigh safety protection level
  1. Falhas Comuns & Maintenance Solutions

3.1 Fault Codes & Solução de problemas

Código de falhaTipo de falhaPossíveis causasSoluções
O-COverload Tripping1. Excessive motor load1. Check load and eliminate mechanical jamming
2. Too small O-TIME setting2. Appropriately increase O-TIME value
3. Abnormal power supply voltage3. Measure three-phase voltage to ensure balance
P-PPhase Loss / Open Phase1. Broken or loose power wire1. Check circuit connection and fasten terminals
2. Burned contactor contacts2. Replace faulty contactor contacts
3. Motor winding failure3. Measure insulation resistance of motor winding
S-CParar / Blockage1. Instant stall during motor startup1. Inspect mechanical transmission system
2. Too short D-TIME setting2. Appropriately extend D-TIME value
3. Stuck mechanical load3. Remove load jamming failure
No DisplayPower Failure1. Control power disconnected1. Check power wiring
2. Power voltage out of range2. Measure input voltage (24-240V)
3. Blown internal fuse3. Replace internal fuse
Abnormal DisplayElectromagnetic Interference1. Close to high-power inverter / electric welder1. Keep away from interference sources or add shielding measures
2. Fiação solta2. Inspect and fasten all wiring
3. Firmware error3. Restore device to factory settings

3.2 Daily Maintenance Schedule

Ciclo de ManutençãoMaintenance ItemsPontos de Operação
DiárioInspeção VisualClean panel and heat dissipation holes, check normal LED display
WeeklyInspeção de fiaçãoCheck loose terminals and oxidation phenomenon
MensalParameter VerificationConfirm O-TIME and D-TIME conform to motor rated values
TrimestralTeste de FunçãoSimulate overload and phase loss faults to verify protection accuracy
AnualComprehensive InspectionCheck aging of internal components, update firmware if necessary
  1. Full EOCRSSD Series Model List

The EOCRSSD series has 3 basic models covering current range 0.5-60A to meet protection demands of motors with different power.

ModeloCurrent Protection RangeControl Power SupplyPrincipais recursosPotência do motor aplicável (380V)
EOCRSSD-05S0.5-6UM24-240V CA/CCSpecial for low current, direct wiring0.18-3kW
EOCRSSD-30S3-30UM24-240V CA/CCGeneral medium current type, direct wiring1.5-15kW
EOCRSSD-60S5-60UM24-240V CA/CCGeneral high current type, direct wiring (External CT required above 60A)3-30kW

Observação: The whole series supports overload, phase loss and stall protection; independent adjustable startup delay (D-Time) and overload action time (O-Time); LED digital display for operating current and fault causes.

  1. Cross-brand Product Comparison
Comparison ItemsSchneider EOCRSSD-30SSiemens 3RB2026-1KB0ABB CM-MSS.61SOmron K8DS-PH1
Faixa Atual3-30UM2.5-32UM0.1-40UM3-30UM
Control Power Supply24-240V CA/CC24-240V CA/CC24-240V CA/CC24-240V CA/CC
Funções de proteçãoSobrecarga, Phase Loss, PararSobrecarga, Phase Loss, PararSobrecarga, Phase Loss, Parar, Phase UnbalanceSobrecarga, Phase Loss, Parar
Display Mode7-segment LED digital tubeLED indicator lightDigital displayLED indicator light
Output Contacts1NÃO+1NC1NÃO+1NC1NÃO+1NC1NÃO+1NC
Grau de precisão±1%±2%±1%±2%
Tamanho da instalação56×78×120mm55×78×118mm56×78×120mm55×78×118mm
Faixa de preçoMédio (Sobre 370 RMB)Alto (Sobre 500 RMB)Alto (Sobre 480 RMB)Médio (Sobre 350 RMB)
Principais vantagensIntuitive digital display, fault record, 1:1 replacement for SS seriesBrand premium, excellent system integrationProteção de desequilíbrio de fase, alta precisãoEconômico, velocidade de resposta rápida
  1. Air Shipment Compliance & Informações de certificação

6.1 Air Shipment Compliance Judgment

Product Category: Electrical and electronic equipment (No built-in lithium battery / super capacitor)

UN Number: Não obrigatório (Non-dangerous goods)

Shipping Restrictions: No special restrictions, deliver as general cargo

Packaging Requirement: Adopt anti-static packaging to avoid static damage to internal components during transportation

6.2 Informações de certificação

Certification TypeCertification StandardEscopo aplicávelKey Requirements
Certificação CEEM 60947-4-1 (Segurança Elétrica)EU MarketComply with Low Voltage Directive (LVD) and EMC Directive
EM 61000-6-2 (EMC Immunity)
Certificação ULUL 508 (Industrial Control Equipment)North America MarketMeet North American electrical safety standards
CSA CertificationCSA C22.2 No.14 (Control Equipment)Canada MarketConform to Canadian safety standards
IEC CertificationCEI 60947-4-1Global MarketComply with standards of International Electrotechnical Commission

Observação: CE marks and certification numbers are marked on product body and outer package. Technical documents shall include test reports, risk assessment reports and Declaration of Conformity (DoC), which shall be kept for at least 10 anos.

  1. Fórmula de seleção & Quick Memorization Rules

7.1 Fórmula de seleção

Calculate motor current first, match EOCRSSD properly;

05 stands for 0.5-6A, 30 covers 3-30A;

60 reaches 60A, match external CT for higher current;

Select S/W according to control power, S means 24-240 ampla tensão;

Three core protections: sobrecarga, phase loss and stall;

Easy fault checking via digital display, convenient DIN rail installation.

7.2 Quick Memorization Rules

Correspondência atual: Rated motor current shall be within 30%-80% of protector range, avoid boundary value affecting accuracy

Voltage Selection: Prioritize Type S (24-240V CA/CC) control power for stronger compatibility

Configuração de parâmetros:

O-TIME: Definir 10-20 seconds when current is 1.2 times motor rated current

D-TIME: Set as motor startup time plus 2 segundos

Replacement Rule: Realize 1:1 direct replacement for traditional EOCR-SS series and thermal relays without changing installation size and wiring

  1. Aplicável & Cenários Inaplicáveis

Cenários Aplicáveis

  1. General Industrial Motors: Protection for water pumps, fãs, compressors and other common equipment
  2. Pequenas linhas de produção: Single motor control loop requiring visualized fault display
  3. Renovation Projects: Replace traditional thermal relays to improve protection precision and convenience
  4. Harsh Working Environment: Temperature range -20℃~60℃, suitable for most industrial sites
  5. Multi-voltage System: 24-240V wide voltage adaptation, fit for transnational equipment and complex power supply environment

Cenários Inaplicáveis

  1. High-precision Control: Intelligent control system needing 4-20mA analog output or communication function (Recommend EOCR-E series)
  2. Extra-high Current Motor: Current over 60A without space for external CT installation (Recommend EOCR-3DM2 series)
  3. Special Protection Demand: Occasions requiring earth protection, leakage protection or phase sequence protection (Recommend EOCR-DS1 series)
  4. Explosion-proof Environment: Hazardous areas needing explosion-proof certification (Choose dedicated explosion-proof protectors)

Full Series Model List of Schneider EOCR Digital Motor Protectors

  1. Series Classification Overview

Schneider EOCR digital motor protectors are divided into three categories by function positioning: Tipo Econômico, Multifunctional Digital Type and Intelligent Type, covering current range 0.5-800A to meet various industrial demands.

  1. Economical Digital Protectors (EOCR-SS/SSD Series)

2.1 EOCR-SS Series (LED Indication)

ModeloFaixa AtualPoder de controleNúmero do pedido.Recursos principaisPotência Aplicável (380V)
EOCR-SS05S0.5-6UM24-240V CA/CC15872Overload/Phase Loss/Stall protection, Indicação LED0.18-3kW
EOCR-SS30S3-30UM24-240V CA/CC15873Same protection functions1.5-15kW
EOCR-SS60S5-60UM24-240V CA/CC15874Same protection functions3-30kW
EOCR-SS05W0.5-6UM380-440V e15875Dedicated 380V control power0.18-3kW
EOCR-SS30W3-30UM380-440V e15876Dedicated 380V control power1.5-15kW
EOCR-SS60W5-60UM380-440V e15877Dedicated 380V control power3-30kW

2.2 EOCR-SSD Series (Digital Display Upgraded Version)

ModeloFaixa AtualPoder de controleNúmero do pedido.Recursos principaisPotência Aplicável (380V)
EOCRSSD-05S0.5-6UM24-240V CA/CC15878Dual digital & LED display, fault record, inverter optimized0.18-3kW
EOCRSSD-30S3-30UM24-240V CA/CC15879Same functions1.5-15kW
EOCRSSD-60S5-60UM24-240V CA/CC15880Same functions3-30kW
EOCRSSD-05C0.5-6UM380-440V e15881380V dedicated, dual display0.18-3kW
EOCRSSD-30W3-30UM380-440V e15882380V dedicated, dual display1.5-15kW
EOCRSSD-60W5-60UM380-440V e15883380V dedicated, dual display3-30kW
  1. Multifunctional Digital Protectors (EOCR-E Series)

3.1 EOCR-3DE/FDE Series (Basic Digital Type)

ModeloFaixa AtualPoder de controleWiring TypeRecursos principaisCenários Aplicáveis
EOCR-3DE-050.5-6UM24-240V CA/CCWindow typeOverload/Phase Loss/Stall/Reverse Phase/Unbalance protection, pre-alarmGeneral industrial motors
EOCR-3DE-303-30UM24-240V CA/CCWindow typeSame functionsGeneral industrial motors
EOCR-3DE-605-60UM24-240V CA/CCWindow typeSame functionsGeneral industrial motors
EOCR-FDE-050.5-6UM24-240V CA/CCFeed-through typeSame as 3DE series with different wiringSpace-limited installation
EOCR-FDE-303-30UM24-240V CA/CCFeed-through typeSame as 3DE series with different wiringSpace-limited installation
EOCR-FDE-605-60UM24-240V CA/CCFeed-through typeSame as 3DE series with different wiringSpace-limited installation

3.2 EOCR-3EZ/FEZ Series (With Earth Fault Protection)

ModeloFaixa AtualPoder de controleWiring TypeRecursos principaisCenários Aplicáveis
EOCR-3EZ-050.5-6UM24-240V CA/CCWindow type3DE full functions + adjustable earth fault protection (30mA-1A)Equipment requiring earth protection
EOCR-3EZ-303-30UM24-240V CA/CCWindow typeSame functionsEquipment requiring earth protection
EOCR-3EZ-805-80UM24-240V CA/CCWindow typeSame functionsEquipment requiring earth protection
EOCR-FEZ-050.5-6UM24-240V CA/CCFeed-through typeSame as 3EZ seriesSpace-limited installation + earth protection
EOCR-FEZ-303-30UM24-240V CA/CCFeed-through typeSame as 3EZ seriesSpace-limited installation + earth protection
EOCR-FEZ-805-80UM24-240V CA/CCFeed-through typeSame as 3EZ seriesSpace-limited installation + earth protection

3.3 EOCR-3E420/FE420 Series (With 4-20mA Output)

ModeloFaixa AtualPoder de controleWiring TypeRecursos principaisCenários Aplicáveis
EOCR-3E420-050.5-6UM24-240V CA/CCWindow type3DE functions + 4-20mA analog outputRemote monitoring system
EOCR-3E420-303-30UM24-240V CA/CCWindow typeSame functionsRemote monitoring system
EOCR-3E420-605-60UM24-240V CA/CCWindow typeSame functionsRemote monitoring system
EOCR-FE420-050.5-6UM24-240V CA/CCFeed-through typeSame as 3E420 seriesSpace-limited + monitoramento remoto
EOCR-FE420-303-30UM24-240V CA/CCFeed-through typeSame as 3E420 seriesSpace-limited + monitoramento remoto
EOCR-FE420-605-60UM24-240V CA/CCFeed-through typeSame as 3E420 seriesSpace-limited + monitoramento remoto
  1. Intelligent Protectors (EOCR-3DM2/FDM2/3MZ2 Series)

4.1 EOCR-3DM2 Series (Window Type)

ModeloFaixa AtualPoder de controleRecursos principaisFunção de comunicaçãoCenários Aplicáveis
EOCR-3DM2-WRDB0.5-80UM24Em DCProteção total + digital display + fault record + load selectionRS-485 ModbusDC control system
EOCR-3DM2-WRDU0.5-80UM100-240V CA/CCProteção total + digital display + fault record + load selectionRS-485 ModbusAC & DC universal system
EOCR-3DM2-WRDBHZ0.5-80UM24Em DCWith harmonic suppression functionRS-485 ModbusFrequency conversion drive system
EOCR-3DM2-WRDUHZ0.5-80UM100-240V CA/CCWith harmonic suppression functionRS-485 ModbusFrequency conversion drive system

4.2 EOCR-FDM2 Series (Feed-through Type)

ModeloFaixa AtualPoder de controleRecursos principaisFunção de comunicaçãoCenários Aplicáveis
EOCR-FDM2-FRDB0.5-80UM24Em DCProteção total + digital display + fault record + load selectionRS-485 ModbusDC control system
EOCR-FDM2-FRDU0.5-80UM100-240V CA/CCProteção total + digital display + fault record + load selectionRS-485 ModbusAC & DC universal system
EOCR-FDM2-FRDBHZ0.5-80UM24Em DCWith harmonic suppression functionRS-485 ModbusFrequency conversion drive system
EOCR-FDM2-FRDUHZ0.5-80UM100-240V CA/CCWith harmonic suppression functionRS-485 ModbusFrequency conversion drive system

4.3 EOCR-3MZ2 Series (Tipo de terminal, External CT Required)

ModeloFaixa AtualPoder de controleRecursos principaisFunção de comunicaçãoCenários Aplicáveis
EOCR-3MZ2-TRDB0.5-800UM (External CT)24Em DCProteção total + digital display + fault record + load selectionRS-485 ModbusHigh current motor
EOCR-3MZ2-TRDU0.5-800UM (External CT)100-240V CA/CCProteção total + digital display + fault record + load selectionRS-485 ModbusHigh current motor
EOCR-3MZ2-TRDBHZ0.5-800UM (External CT)24Em DCWith harmonic suppression functionRS-485 ModbusHigh current frequency conversion motor
EOCR-3MZ2-TRDUHZ0.5-800UM (External CT)100-240V CA/CCWith harmonic suppression functionRS-485 ModbusHigh current frequency conversion motor
  1. Special Function Protectors

5.1 EOCR-DS/DS3 Series (Economical Digital Display Type)

ModeloFaixa AtualPoder de controleRecursos principaisCenários Aplicáveis
EOCRDS-05S0.5-6UM24-240V CA/CCOverload/Phase Loss/Stall protection, digital displayBasic digital display demand
EOCRDS-30S3-30UM24-240V CA/CCOverload/Phase Loss/Stall protection, digital displayBasic digital display demand
EOCRDS-60S5-60UM24-240V CA/CCOverload/Phase Loss/Stall protection, digital displayBasic digital display demand
EOCRDS3-05S0.5-6UM24-240V CA/CCUpgraded version with additional phase unbalance protectionBasic display + unbalance protection
EOCRDS3-30S3-30UM24-240V CA/CCUpgraded version with additional phase unbalance protectionBasic display + unbalance protection
EOCRDS3-60S5-60UM24-240V CA/CCUpgraded version with additional phase unbalance protectionBasic display + unbalance protection

5.2 EOCR-PMZ/PFZ Series (Power Monitoring Type)

ModeloFaixa AtualPoder de controleRecursos principaisFunção de comunicaçãoCenários Aplicáveis
EOCR-PMZ-050.5-6UM24-240V CA/CCProteção total + monitoramento de energia + medição de energiaRS-485 ModbusEnergy consumption monitoring system
EOCR-PMZ-303-30UM24-240V CA/CCProteção total + monitoramento de energia + medição de energiaRS-485 ModbusEnergy consumption monitoring system
EOCR-PMZ-805-80UM24-240V CA/CCProteção total + monitoramento de energia + medição de energiaRS-485 ModbusEnergy consumption monitoring system
EOCR-PFZ-050.5-6UM24-240V CA/CCFeed-through type, same functions as PMZ seriesRS-485 ModbusMonitoramento de energia + limited space
EOCR-PFZ-303-30UM24-240V CA/CCFeed-through type, same functions as PMZ seriesRS-485 ModbusMonitoramento de energia + limited space
EOCR-PFZ-805-80UM24-240V CA/CCFeed-through type, same functions as PMZ seriesRS-485 ModbusMonitoramento de energia + limited space

5.3 EOCR-DGT Series (Tipo de proteção contra vazamento)

ModeloFaixa AtualFaixa de proteção contra vazamentoPoder de controleRecursos principaisCenários Aplicáveis
EOCR-DGT-050.5-6UM30mA-1A24-240V CA/CCLeakage + Sobrecarga + Phase Loss + Reverse Phase + Unbalance protectionEquipment in humid environment
EOCR-DGT-303-30UM30mA-1A24-240V CA/CCFull combined protectionEquipment in humid environment
EOCR-DGT-605-60UM30mA-1A24-240V CA/CCFull combined protectionEquipment in humid environment
EOCR-DGT-805-80UM30mA-1A24-240V CA/CCFull combined protectionEquipment in humid environment
  1. Quick Memorization of Model Naming Rules
  2. Prefixo: EOCR= Schneider motor protection relay series mark
  3. Código da série:

SS/SSD: Economical type (SSD with digital display)

3DE/FDE/3EZ/FEZ/3E420/FE420: Multifunctional digital type

3DM2/FDM2/3MZ2: Tipo inteligente (3MZ2 needs external CT)

DS/DS3: Simple digital display type

PMZ/PFZ: Power monitoring type

DGT: Leakage protection type

  1. Current Code: 05(0.5-6UM), 30(3-30UM), 60(5-60UM), 80(5-80UM)
  2. Power Supply Code: S(24-240V CA/CC), C(380V e), B(24CCV), Você(100-240V CA/CC)
  3. Modo de fiação: C(Window), F(Feed-through), T(Tipo de terminal)
  4. Função Especial: HZ(Harmonic suppression), 420(4-20mA output)
  5. Quick Selection Table by Functional Demand
Demanda FuncionalSérie recomendadaPrincipais vantagensMax Current
Proteção básica & baixo custoEOCR-SS/SSDEconômico, fácil instalação60UM
Proteção básica + digital displayEOCRSSD/DSVisualized fault checking60UM
Proteção total + proteção contra falha à terraEOCR-3EZ/FEZAnti-leakage, high safety level80UM
Monitoramento remoto + analog signalEOCR-3E420/FE4204-20mA signal output, easy system integration60UM
Controle inteligente + comunicaçãoEOCR-3DM2/FDM2Modbus remote control80UM
High current motor protectionEOCR-3MZ2Match external CT, cover 0.5-800A800UM
Energy consumption monitoring + proteçãoEOCR-PMZ/PFZPower statistics and energy-saving analysis80UM
Proteção contra vazamento + full combined protectionEOCR-DGTIntegrated leakage protection80UM

Anterior:

Deixe uma resposta