The domestic full model designation is commonly LC1E630U7N. Discontinued in April 2021. It is a 3-pole high-power AC contactor.
✅ Model Code Definition
LC1E: EasyPact TVS AC contactor series
630: AC-3 rated operational current of 630 UM
Você: Tensão da bobina 240 V e
7: 50/60 Hz universal AC coil
N: Domestic version with CCC certification (Overseas model LC1E630U7 does not carry suffix N)
This unit has no built-in auxiliary contacts. Auxiliary contacts require add-on accessories.
📋 Core Electrical Specifications
| Item | Parâmetro |
| Número de pólos | 3P, 3SEM contatos principais |
| Utilisation category | AC-3 (cargas do motor), AC-1 (cargas resistivas) |
| AC-3 Ie | 630 UM (@ ≤440 V, 55 °C) |
| AC-1 Ith | 1000 UM (@ 40 °C) |
| Tensão nominal de isolamento Ui | 690 V |
| Tensão nominal suportável de impulso Uimp | 8 kV |
| Coil rated voltage Uc | 240 V e, 50/60 Hz |
| Faixa de operação da bobina | Escolher: 0.85~1.1 × Uc; Cair fora: 0.25~0.5 × Uc |
| Inrush power consumption | 1650 VA; Hold power consumption: 22 VA |
| Compatible motor power | 220 V: 185 kW 380/400 V: 335 kW 440 V: 400 kW 690 V: 450 kW |
| Rated short-time withstand current Icw | 5050 UM / 10 é |
| Fazendo / Capacidade de ruptura | Fazendo: 6300 UM; Quebra: 5040 E @440V |
🛠 Mechanical & Endurance Characteristics
Resistência mecânica: 4 milhões de ciclos
AC-3 electrical endurance: 600,000 ciclos; AC-1: 200,000 ciclos
Maximum operating rate: 1200 ciclos/hora
Tempo de operação: Closing 40~80 ms; Opening 100~200 ms
Montagem: Plate mount (high-current frame does not support standard DIN rail)
Torque de aperto: Circuito principal 58 N·m; Circuito de controle 1.2 N·m
Dimensão geral: W309 × H304 × D255 mm; Peso líquido: 18.6 kg
Classe de proteção: IP00
Temperatura ambiente de operação: -5 ~ +55 °C; No derating up to altitude 3000 eu
📌 Typical Applications
Ventiladores de alta potência, bombas de água, compressores de ar, trituradores, large motor starter cabinets, low-voltage switchgear; AC-3 squirrel-cage motor start-stop control, switching of heavy resistive loads.
⚠️ Discontinuation & Opções de substituição
LC1E630U7N discontinued in April 2021, no new original production. Stock / second-hand units available on market.
- Schneider OEM replacement: LC1G630KUEC (Série TeSys Giga, 630 UM, 240 VAC compatible coil)
- Alternativa doméstica: CJX2-F630, NC2-630, etc.. (Verifique a tensão da bobina, temperature rise and short-time withstand current)
🧰 Optional Accessories
Bloco de contato auxiliar: LA1KN (add-on 1NO+1NC)
Coil surge suppressor, intertravamento mecânico, terminal shroud, relé de sobrecarga térmica (large frame LRD series)
📎 Inspection Checklist for Second-hand Acceptance
- Measure coil resistance and compare with reference value for same model; power on to test pull-in / drop-out, no sticking or abnormal noise
- Inspect main contact surface for ablation or welding; check consistency of contact resistance across three phases
- Dielectric strength test: 2.5 kV / 1 min between phases and main circuit to earth
- Verify terminal tightening torque; inspect busbar contact surface for oxidation and overheating discoloration
- Test operating voltage: Reliable pull-in at 0.85Uc, reliable drop-out below 0.5Uc
LC1G630KUEC VS LC1E630U7 Parameter Comparison Table
LC1E630U7: TVS EasyPact, descontinuado; LC1G630KUEC: TeSys Giga, OEM replacement. KU = 100~250 V AC/DC wide-range coil (compatible with original 240 VAC).
| Parâmetro | LC1E630U7 | LC1G630KUEC | Observações |
| Série de produtos | TVS EasyPact (Easy TeSys) | TeSys Giga | Schneider new generation high power contactor |
| Model definition | 3P, AC-3 630 UM, bobina 240 V e, 50/60 Hz | 3P, AC-3 630 UM, 100~250 V AC/DC wide coil | Giga AC/DC universal coil, direct replacement for U7 (240VAC) without control circuit modification |
| Estado do produto | Discontinued Apr 2021, estoque / second-hand | Em produção, genuine new | |
| Poloneses / Principais contatos | 3P, 3NÃO | 3P, 3NÃO | |
| AC-3 rated Ie @≤440V | 630 UM (55 °C) | 630 UM | Identical rating for motor loads |
| AC-1 conventional thermal current Ith @40 °C | 1000 UM | 1050 UM | Giga higher resistive load capacity |
| Tensão nominal de isolamento Ui | 690 V | 1000 V | Giga upgraded insulation |
| Tensão nominal suportável de impulso Uimp | 8 kV | 8 kV | Idêntico |
| Rated short-time withstand current Icw | 5050 UM /10 é | 5050 UM /10 é; 4400 UM /30 é | Same 10s withstand; Giga superior long-duration withstand |
| Making capacity @440V | 6300 UM | 7220 UM | Giga higher short-circuit making capability |
| Breaking capacity @440V | 5040 UM | 5550 UM | |
| Contatos auxiliares integrados | Nenhum, LA1KN add-on required | 1NO+1NC built-in | No need to purchase auxiliary contact block for retrofit |
| Tipo de bobina | AC only, 240 V, 50/60 Hz | Wide-range AC/DC 100~250 V | Compatible with AC and DC control supply, better engineering flexibility |
| Faixa de operação da bobina | Puxar para dentro:0.85~1.1Uc Drop-out:0.25~0.5Uc | Puxar para dentro:0.8~1.1Ucmin~Ucmax Drop-out: ≤0.45Uc | Wider voltage tolerance for grid fluctuation |
| Consumo de energia da bobina | Inrush 1650 VA; Hold 22 VA | Inrush 800 VA; Hold 15 VA | Much lower coil power, less cabinet heat |
| Resistência mecânica | 4 milhões de ciclos | 5 milhões de ciclos | 25% melhoria |
| AC-3 electrical endurance | 600,000 ciclos | 1 milhões de ciclos | Significant improvement under motor duty |
| Maximum operating rate | 1200 ciclos/hora | AC-3: 600 ciclos/hora | LC1E better for frequent cycling; LC1G sufficient for standard motor applications |
| Tempo de operação | Close 40~80 ms; Open 100~200 ms | Close 40~70 ms; Open 15~50 ms | Giga faster opening |
| Temperatura ambiente | -5 ~ +55 °C | -25 ~ +60 °C | Giga supports low-temperature startup |
| Classe de proteção | IP00 | IP2X with shroud | Finger-safe protection |
| Dimensão(L×A×P) | 309 × 304 × 255 milímetros | 211 × 284 × 266 milímetros | ~32% narrower, economiza espaço no armário |
| Peso líquido | 18.6 kg | 14.2 kg | 4.4 kg lighter for easier handling |
| Main circuit tightening torque | 58 N·m | 58 N·m | Busbar torque unchanged, busbars can be reused |
| Control circuit torque | 1.2 N·m | Terminal de mola push-in | Tool-free control circuit connection |
| Montagem | Plate mount | Plate mount | Mounting hole pattern incompatible, base plate re-drilling required |
| Power dissipation per pole (AC-3) | 48 C | 26 C | Lower contact loss, less temperature rise |
| Motor power AC-3 @400V | 335 kW | 335 kW | Identical motor rating |
| Extra features | Basic contactor | Optional contact wear diagnosis, intertravamento mecânico, comentários sobre status | Predictive maintenance available for critical loads |
✅ Replacement Summary
- Main circuit rating fully equivalent: Adequado para 335 kW, 400 V motor. Keep busbar torque at 58 N·m; Mounting hole layout differs, base plate re-drilling required.
- Control circuit advantage: LC1G630KUEC wide-range 100~250 V AC/DC coil works directly with original 240 VAC control supply; lower coil power and built-in 1NO+1NC auxiliary contacts, no auxiliary accessory purchase.
- Limitação: Max operating rate reduced to 600 ciclos/hora. Applications with frequent inching or high cycle count need evaluation.
- Temperature rise & confiabilidade: Giga higher insulation voltage, lower contact loss and wider ambient temperature range, ideal for critical continuous-duty loads.
⚠️ Engineering Replacement Risk Notes
Original 240 V AC control supply can connect directly to LC1G630KUEC coil.
Do not replace directly for heavy inching / reversão frequente >600 ciclos/hora; performance review mandatory.
Much narrower frame width; existing busbars and protective baffles need rework.
LC1G630KUEC (TeSys Giga) Indústria & Load Application Guide
LC1G630KUEC: AC-3 630 UM, rated for 335 kW three-phase squirrel cage motor at 400 V. Built-in contact wear diagnosis, wide-range AC/DC coil and IP2X shroud. Designed for high-power motor start-stop, star-delta starters and heavy resistive load switching. Max operating rate 600 ciclos/hora, not recommended for high-frequency inching.
🏭 1. Água & Águas Residuais (Waterworks, Sewage Plants, Estações de bombeamento)
Typical loads: Large raw water pumps, bombas de elevação de esgoto, bombas de circulação, sludge pumps, sopradores de aeração, main drive motors for scrapers.
Características: 24/7 continuous operation requiring high reliability. LC1G supports -25 °C low temperature operation and contact wear diagnosis for predictive maintenance. Widely used in MCC pump cabinets and the most common retrofit candidate replacing LC1E630U7.
🌬️ 2. Grande HVAC, Centros de dados & Complexos Comerciais
Typical loads: Chiller compressors, large cooling tower fans, primary / secondary chilled water pumps, building exhaust fans.
Características: Building MCC switchgear, frequent start-stop and elevated cabinet ambient temperature. Giga Ui=1000 V high insulation and low temperature rise; wide coil accommodates building supply voltage fluctuation.
⚙️ 3. Metalurgia, Mineração & Materiais de Construção
Typical loads: Trituradores, moinhos de bolas, heavy belt conveyors, kiln blowers, hoist motors (derating required for AC-4 duty).
Características: Heavy shock loads and dusty harsh environment; strong short-time withstand and short-circuit capacity. AC-4 hoist duty limited to max 150 ciclos/hora, derating mandatory during selection.
🛢️ 4. Petroquímica & Energia (Óleo & Gás, Solar, Energia Eólica)
Typical loads: Process pumps, compressores, thermal oil furnace blowers, wind turbine yaw / pitch large motors, high-power resistive load switching for PV systems.
Características: Mounted outside explosion-proof enclosures, prone to supply voltage fluctuation. Wide-range 100~250 V AC/DC coil with high control supply compatibility; Marine certification available for auxiliary motor circuits on offshore platforms.
📦 5. Papel, Polpa, Comida & Farmacêutico
Typical loads: Paper machine main fans, bombas de vácuo, large agitator motors, drying resistive heating loads (AC-1).
Características: Continuous production with zero unscheduled downtime tolerance. Contact wear diagnosis enables advance replacement planning.
🏗️ 6. Infraestrutura & Railway Auxiliary Systems
Typical loads: Tunnel exhaust fans, station large water pumps, refrigeradores, port crane auxiliary drives, terminal conveying equipment.
Características: Preferred choice for project-type MCC panel builders; compatible with star-delta starter schemes with LA9G mechanical interlock accessory.
🧱 7. OEM Panel Builders & System Integrators
Panel builders: Low voltage Motor Control Centre (MCC), large motor starter cabinets, star-delta starter panels, soft starter bypass contactors (Bypass duty breaking capacity assessment required).
✅ Load Category Compatibility Summary
AC-3 (Primary use): Normal start-stop squirrel cage motors (bombas, fãs) ✅ Preferred
AC-1: Aquecimento resistivo, resistive load switching, Ith=1050 A ✅
AC-4: Motor plugging / reverse braking, avançando (hoists etc.), derating required and strict operating frequency limits ⚠️
AC-6a: Comutação de banco de capacitores, capacitor dedicated protection required; direct use not recommended
⚠️ Key Selection Limitations
- Max AC-3 operating rate: 600 ciclos/hora. Applications with higher frequency (avançando, reversão frequente) are not recommended; LC1E630U7 is preferred.
- Ambiente operacional: -25 °C ~ +60 °C, wider temperature range than legacy LC1E630U7.
- Mounting hole pattern incompatible with LC1E; cabinet base plate re-drilling required for retrofit.
- Marine type approval available for vessel applications.
Contator,disjuntor,sensor,Codificador,CLP,Conversor






















NH42-63-318x560.png)