LC1N2501 is a 3-pole 25A AC Contactor of Schneider Electric EasyPact D3N Series. It is standard configured with 3 contatos principais normalmente abertos + 1 normally closed auxiliary contact. It is suitable for 11kW / 380V motor control under AC-3 duty, widely used in industrial automation and motor control circuits, featuring high reliability and flexible installation.
- Definição de segmento de modelo
| Segmento | Significado | Descrição detalhada |
| LC1 | Código da série do produto | LC = TeSys series contactor; 1 = Standard AC contactor |
| N | Sub-series identifier | N = EasyPact D3N Series (replaces the original LC1E Series); economy design for general industrial applications |
| 25 | Corrente operacional nominal | Main contact rated current 25A (AC-3 / 440V, 60°C) |
| 1 | Configuração de contato auxiliar | 0 = 0 Normalmente aberto; 1 = 1 Normalmente fechado, i.e. 1 NC auxiliary contact |
| [Sufixo] | Código de tensão da bobina | por exemplo. M5=220V AC 50Hz, B5=24V DC, C5=36V AC, F5=110V AC, Q5=380V AC |
Exemplos completos de modelos:
LC1N2501M5N (220V AC coil, 50Hz)、LC1N2501B5N (24V DC coil)
- Parâmetros de especificação principal
| Categoria de parâmetro | Technical Index | Observações |
| Basic Characteristics | ||
| Tipo de produto | 3-Pole AC Contactor | EasyPact D3N Series, replacement for LC1E2501 |
| Marca | Schneider Elétrica | Benchmark brand in industrial control |
| Configuração do contato principal | 3NÃO (3 Normalmente aberto) | Standard AC-3 motor control configuration |
| Configuração de contato auxiliar | 1NC (1 Normalmente fechado) | Expandable up to maximum 4 contatos auxiliares (2NÃO+2NC) |
| Corrente Operacional Nominal | 25UM (AC-3, 440V, 60°C) | Potência do motor correspondente: 11kW@380V, 15kW@220V |
| Tensão operacional nominal | ≤690V AC (50/60Hz) | Maximum working voltage of main circuit |
| Desempenho Elétrico | ||
| Rated Insulation Voltage Ui | 690V | Compatível com IEC 60947-4-1 |
| Rated Impulse Withstand Voltage Uimp | 6kV | Strong surge withstand capability |
| Frequência operacional nominal | 1200 cycles/hour (AC-3) | Suitable for frequent start-stop operation |
| Vida Mecânica | ≥10 milhões de ciclos | High durability design |
| Vida Elétrica | ≥1 million cycles (AC-3, corrente nominal) | Meets long-term service requirements |
| Coil Control Voltage | 24V~380V AC/DC optional | Padrão: 220V e (M5) |
| Consumo de energia da bobina | Pick-up: aprox.. 100VA; Holding: aprox.. 10VA | Baixo consumo de energia, economia de energia & alta eficiência |
| Physical Dimensions | ||
| Método de montagem | 35mm DIN rail or screw mounting | Two mounting options for different cabinet layouts |
| Overall Dimension | W45mm × H80mm × D85mm | Design compacto, economiza espaço no armário |
| Peso | Aprox.. 170g | Leve para fácil instalação & handling |
| Tipo de terminal | Circuito principal: Tipo de parafuso; Circuito de controle: Spring type | Main circuit compatible with 1.5-10mm² wire, tightening torque 1.85N·m |
| Condições Ambientais | ||
| Temperatura operacional | -25°C ~ +60°C | Wide temperature range, adapts to harsh industrial environments |
| Temperatura de armazenamento | -40°C ~ +85°C | Withstands extreme temperature storage |
| Proteção de entrada | IP20 | Protects against finger access and solid foreign objects, suitable for cabinet installation |
| Humidity Resistance | 5%~95% UR (sem condensação) | Adapts to humid environments |
| Certificações & Standards | ||
| Main Standards | CEI 60947-4-1, GB14048.4 | Compliant with international and national standards |
| Marcas de Certificação | CCC, CE, UL, CSA | Global market access qualifications |
- Lista de acessórios & Mounting Parts
| Part Model | Nome | Função | Cenário de aplicação |
| LRN07N-LRN35N | Relé de sobrecarga térmica | Direct plug-in with contactor, provides motor overload protection | Motor control circuit requiring overload protection |
| LANN01N-LANN22N | Bloco de contato auxiliar | Expand auxiliary contact quantity (máx.. 2NÃO+2NC) | Complex control circuits requiring more auxiliary contacts |
| LA9D09978C | Mechanical Interlock Accessory | Interlocks two contactors to prevent phase-to-phase short circuit | Reversible motor control (Forward/Reverse) |
| LA9D0902 | Mecânico + Electrical Interlock | Dual protection of mechanical and electrical interlock | Reversible control circuits with high safety requirements |
| Overvoltage Suppression Module | RC / Varistor Surge Suppressor | Absorbs back EMF generated during coil de-energization | Protects electronic components in control circuit |
| Trilho de montagem | 35mm Standard DIN Rail | Fixes contactor in position | Standardized installation inside control cabinet |
| Tampa de proteção terminal | Insulating Protective Shield | Prevents accidental electric shock and improves safety | Protection for exposed terminals, complies with safety regulations |
| Installation Manual | Operation Guideline | Provides detailed installation procedures and wiring diagrams | On-site installation guidance to ensure correct wiring |
- Competitor & Equivalente entre marcas
| Marca | Modelo de substituição | Similar Features | Diferenças |
| Schneider Internal Replacement | LC1D2501 | 3-pole 25A, 1NC auxiliary, AC-3 11kW | TeSys D series, better performance, preço mais alto |
| ABB | A16-30-01 | 3-pole 25A, 1NC auxiliary, 11kW@400V | Similar dimension, slightly higher coil power consumption, comparable price |
| Siemens | 3RT2026-1BB40 | 3-pole 25A, 1NC auxiliary, 11kW@400V | Vida mecânica 10 milhões de ciclos, vida elétrica 2 milhões de ciclos, slightly higher price |
| Mitsubishi | S-N25 | 3-pole 25A, 1NC auxiliary, 11kW@400V | Tamanho menor, compact mounting, preço moderado |
| Chint | CJX2-2501 | 3-pole 25A, 1NC auxiliary, 11kW@380V | Alternativa doméstica, desempenho de alto custo, desempenho semelhante |
| Delicioso | CJX2S-2501 | 3-pole 25A, 1NC auxiliary, 11kW@380V | Alternativa doméstica, Menor preço, suitable for budget-limited projects |
- Diretrizes de seleção & Soluções de substituição
5.1 Parâmetros de seleção chave
| Parâmetro | Pontos-chave da seleção | Recommended Specification |
| Rated Current Matching | Contactor rated current ≥ motor rated current (Dever AC-3) | 25A contactor suitable for ≤11kW/380V motors |
| Configuração de contato auxiliar | Select NO/NC quantity according to control circuit demand | Padrão 01(1NC); Normally Open select 10(1NÃO); More contacts select 22 |
| Seleção de tensão da bobina | Consistent with control circuit voltage | Industrial common: 220V e(M5); Safety voltage: 24Em DC(B5) |
| Método de montagem | Determined by control cabinet layout | Montagem em trilho DIN (padrão); Screw mounting for limited space |
| Protection Requirement | Need for overload protection and interlock function | Motor control must match LRN thermal relay; Reversible control requires interlock accessory |
| Frequência operacional | High-frequency start-stop occasion requires high-cycle model | Padrão 1200 cycles/hour; Ultra-high frequency choose LC1D series |
5.2 Recomendações de substituição
Current rating mismatch:
Motor power ≤7.5kW: Select LC1N1801 (18UM)
Motor power 15kW: Select LC1N3201 (32UM)
Insufficient auxiliary contacts:
Add LANN series auxiliary contact block, expandable up to 2NO+2NC maximum
Different control voltage:
24V DC control: LC1N2501B5N
380V AC control: LC1N2501Q5N
Higher performance required:
Choose LC1D2501 (TeSys D series), vida mecânica 10 milhões de ciclos, vida elétrica 2 milhões de ciclos, stronger vibration resistance
Budget limited:
Adopt domestic alternatives such as Chint CJX2-2501, Delixi CJX2S-2501; similar performance with price reduced by about 30-50%
5.3 Application Precautions
- Confirm coil voltage matches control circuit before installation to avoid coil burnout.
- Fasten main circuit wiring with recommended torque 1.85N·m to prevent overheating and poor contact.
- When directly plugging with LRN series thermal relay, ensure complete latch locking to prevent loosening by vibration.
- Reversible control circuit must be equipped with LA9D09978C mechanical interlock to prevent phase-to-phase short circuit.
- It is recommended to parallel surge suppressor at both ends of the coil to protect PLC/relay contacts in control circuit.
- When ambient temperature exceeds 40°C, derate rated current (10% reduction per additional 10°C rise).
- Regularly check contact ablation; replace contactor when main contact wear exceeds 1mm.
- Cenários típicos de aplicação
Direct starting control of three-phase asynchronous motor (≤11kW/380V)
Start-stop control for fans, bombas de água e máquinas em geral
Electrical control for compressors, conveyors and industrial equipment
Compressor control for air conditioning and refrigeration systems
Lighting and ventilation system control in building electrical systems
Motor control circuits for automated production lines
Auxiliary motor control for machine tool equipment
Output switching control for photovoltaic inverters and UPS power supplies
Complete Model List of Schneider LC1N Series (EasyPact D3N) Contatores
LC1N Series is Schneider Electric EasyPact D3N 3-pole AC contactor, replacing the original LC1E Series. It is designed for AC-3 motor control, covering current ratings from 6A to 95A, with multiple auxiliary contact configurations and coil voltage options. Supports DIN rail or screw mounting with IP20 ingress protection.
- Regras de codificação de modelo
| Segmento | Significado | Optional Value | Descrição |
| LC1 | Série de produtos | LC1 | Schneider TeSys contactor series |
| N | Subsérie | N | EasyPact D3N Series (economy type) |
| XX | Corrente nominal | 06/09/12/18/25/ 32/38/40/50/65 /80/95 | Unidade: UM (AC-3/440V, 60°C) |
| YY | Contato Auxiliar | 00/01/10/22/11 | 00=No auxiliary; 01= 1NC; 10=1NÃO; 22=2NA+2NC; 11=1NA+1NC |
| Z | Código de tensão da bobina | B/E/F/M/Q/… | B=24V; E=48V; F=110V; M=220V; Q=380V |
| 5月7日 | Freqüência | 5月7日 | 5=50Hz; 7=50/60Hz universal |
| N/C | Origem | N/C | N=Standard; C=Made in China |
Exemplo de modelo completo:
LC1N2501M5N (25UM, 1NC, 220V CA 50 Hz)
- Full Current Rating & Basic Model Matrix
2.1 Standard Auxiliary Configuration (01/10)
| Corrente nominal | Potência do motor correspondente(380V) | 1NC(01) | 1NÃO(10) | Observações |
| 6UM | 2.2kW | LC1N0601 | LC1N0610 | Minimum current size |
| 9UM | 3kW | LC1N0901 | LC1N0910 | - |
| 12UM | 4kW | LC1N1201 | LC1N1210 | - |
| 18UM | 7.5kW | LC1N1801 | LC1N1810 | - |
| 25UM | 11kW | LC1N2501 | LC1N2510 | Most commonly used |
| 32UM | 15kW | LC1N3201 | LC1N3210 | - |
| 38UM | 18.5kW | LC1N3801 | LC1N3810 | - |
| 40UM | 22kW | LC1N4001 | LC1N4010 | - |
| 50UM | 25kW | LC1N5001 | LC1N5010 | - |
| 65UM | 30kW | LC1N6501 | LC1N6510 | - |
| 80UM | 37kW | LC1N8001 | LC1N8010 | - |
| 95UM | 45kW | LC1N9501 | LC1N9510 | Maximum current size |
2.2 Special Auxiliary Configuration (11/22/00)
| Corrente nominal | 1NÃO+1NC(11) | 2NÃO+2NC(22) | No Auxiliary(00) | Cenário de aplicação |
| 6A~38A | LC1NXX11 | LC1NXX22 | LC1NXX00 | Complex control circuit requiring multi-contacts |
| 40A~95A | LC1NXX11 | LC1NXX22 | LC1NXX00 | High-power motor control requiring contact expansion |
- Complete Coil Voltage Options
3.1 AC Coil Voltage Code
| Voltage Code | Tensão da bobina | Frequency Code | Exemplo de modelo completo | Cenário de aplicação |
| B | 24V e | 5(50Hz)/7(50/60Hz) | LC1N2501B5N / LC1N2501B7N | Safety voltage control, PLC output |
| C | 36V e | 5-7 | LC1N2501C5N / LC1N2501C7N | Safety circuit, machine tool control |
| E | 48V e | 5-7 | LC1N2501E5N / LC1N2501E7N | Controle industrial, special equipment |
| F | 110V e | 5-7 | LC1N2501F5N / LC1N2501F7N | Padrão norte-americano, partial equipment |
| M | 220V e | 5-7 | LC1N2501M5N / LC1N2501M7N | Chinese industrial standard, mais amplamente utilizado |
| P | 230V e | 5-7 | LC1N2501P5N / LC1N2501P7N | Padrão europeu, compatible with 220V |
| P | 380V e | 5-7 | LC1N2501Q5N / LC1N2501Q7N | High-voltage control circuit, direct 380V supply |
| R | 400V e | 5-7 | LC1N2501R5N / LC1N2501R7N | European industrial standard |
| S | 415V e | 5-7 | LC1N2501S5N / LC1N2501S7N | Southeast Asian standard |
3.2 DC Coil Voltage Code
| Voltage Code | Tensão da bobina | Exemplo de modelo completo | Cenário de aplicação |
| B | 24Em DC | LC1N2501B5N | Safety control, PLC digital output |
| eu | 48Em DC | LC1N2501L5N | Industrial DC system |
| K | 110Em DC | LC1N2501K5N | Special DC equipment |
| N | 220Em DC | LC1N2501N5N | High-voltage DC control |
- Common Complete Model Combinations
| Modelo Completo | Atual | Contato Auxiliar | Tensão da bobina | Potência do motor correspondente | Aplicação Típica |
| LC1N2501M5N | 25UM | 1NC | 220V CA 50 Hz | 11kW | Bomba de água & fan control |
| LC1N3210B7N | 32UM | 1NÃO | 24Vca 50/60 Hz | 15kW | PLC control circuit |
| LC1N1801F5N | 18UM | 1NC | 110V CA 50 Hz | 7.5kW | Export equipment |
| LC1N5011M7N | 50UM | 1NÃO+1NC | 220Vca 50/60 Hz | 25kW | Compressor control |
| LC1N6522Q5N | 65UM | 2NÃO+2NC | 380V CA 50 Hz | 30kW | Large fan |
| LC1N0900B5N | 9UM | No auxiliary | 24V CA 50 Hz | 3kW | Simple control circuit |
| LC1N9511M7N | 95UM | 1NÃO+1NC | 220Vca 50/60 Hz | 45kW | High-power motor |
- Selection Reference Table
5.1 Current Rating vs Motor Power (AC-3/380V)
| Corrente nominal | Potência do motor(kW) | Wire Size(milímetros) | Matching Thermal Relay |
| 6UM | 2.2 | 1.5 | LRN06N |
| 9UM | 3 | 1.5 | LRN06N |
| 12UM | 4 | 1.5 | LRN07N |
| 18UM | 7.5 | 2.5 | LRN10N |
| 25UM | 11 | 4 | LRN14N |
| 32UM | 15 | 6 | LRN21N |
| 38UM | 18.5 | 6 | LRN21N |
| 40UM | 22 | 10 | LRN25N |
| 50UM | 25 | 10 | LRN32N |
| 65UM | 30 | 16 | LRN35N |
| 80UM | 37 | 25 | LRN35N |
| 95UM | 45 | 35 | LRN40N |
5.2 Auxiliary Contact Expansion Options
| Modelo Básico | Expandable Accessory | Expanded Contact Configuration | Cenário de aplicação |
| LC1NXX01/10 | LANN01N(1NÃO) | 2NÃO / 2NC | Add more control circuit contacts |
| LC1NXX01/10 | LANN22N(2NÃO+2NC) | 3NÃO+2NC / 2NÃO+3NC | Complex control logic |
| LC1NXX00 | LANN01N+LANN02N | 1NÃO+1NC | Expand from no auxiliary to standard configuration |
- Quick Model Selection Guide
- Confirm current rating: Selecione de acordo com a potência do motor (Sob serviço AC-3, contactor rated current ≥ motor rated current).
- Selecione contatos auxiliares: 01(1NC) for stop control; 10(1NÃO) for self-locking; 11(1NÃO+1NC) para controle reversível.
- Match coil voltage: Consistent with control circuit voltage (220V AC common; 24V DC for safety occasions).
- Frequency selection: Domestic standard 50Hz(Código 5); Export equipment use universal 50/60Hz(Código 7).
- Configuração de acessórios: Motor control must match LRN thermal relay; Reversible control requires LA9D mechanical interlock.
- Common Model Replacement Table
| Modelo original | Modelo de substituição | Replacement Reason |
| LC1E2501 | LC1N2501 | EasyPact D3N replaces original EasyPact E Series |
| LC1D2501 | LC1N2501 | Economy model replaces high-performance model, cost reduced by approx. 20% |
| CJX2-2501 | LC1N2501 | Import replaced by domestic, performance improved with similar price |
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares














![NXC-65 da série Kunlun da CHINT Electric é um contator CA de 3 pólos, avaliado em 65A na série NXC. O modelo completo é normalmente expresso como NXC-65 [Tensão da bobina] [Freqüência] NXC-65 from the Kunlun Series by CHINT Electric is a 3-pole AC contactor, rated at 65A in the NXC series. The full model is typically expressed as NXC-65 [Coil Voltage] [Frequency]](https://www.bestcontactor.com/wp-content/uploads/2026/04/ScreenShot_2026-01-30_132315_324-419x560.png)