Definição de segmento de modelo (Phoenix Contact PSR Series Naming Rule) Segment Meaning Description PSR Product Safety Relay Product series identifier for Phoenix Contact safety relays SPP Safety Plug-in Push-in Safety type, pluggable push-in terminal design 24DC 24V DC Rated control circuit supply voltage: 24Em DC (allowable range: 20.4V~26.4V) FSP2 Filtered Safe Pulse 2 Integrated test pulse ...

  • Detalhes do produto
  1. Definição de segmento de modelo (Contato Fênix PSR Series Naming Rule)
SegmentoSignificadoDescrição
PSRProduct Safety RelayProduct series identifier for Phoenix Contact safety relays
SPPSafety Plug-in Push-inSafety type, pluggable push-in terminal design
24CC24Em DCRated control circuit supply voltage: 24Em DC (allowable range: 20.4V~26.4V)
FSP2Filtered Safe Pulse 2Integrated test pulse filter, suitable for SIL 2 safety integrity level applications
2X12 Normally Open safety contacts2-channel normally open safety contact output (enable current path)
1X21 Normally Closed signal contact1-channel normally closed signal contact (feedback loop)
2986588Número do pedidoGlobal unique material / order number of Phoenix Contact
  1. Parâmetros de especificação principal

Informações gerais

ParâmetroValorObservações
Tipo de produtoSafety Coupling RelayUsed for safe shutdown applications
Série de produtosPSRclassicPhoenix Contact classic safety relay series
Nível de segurançaSIL 2 (High/Low Demand Mode)Compatível com IEC 61508, EM 50156
Performance LevelPL cCompliant with EN ISO 13849 (Control Unit DC ≥ 90%)
Stop Category0Immediate stop without delay
Vida Mecânica10×10⁶ switching cyclesElectromechanical relay with mechanically linked contacts, compatível com IEC/EN 61810-3
Largura17.5milímetrosDesign fino, saves control cabinet space
Proteção de entradaIP20 (Body) / IP54 (Wiring Area)Meets industrial environmental protection requirements
Temperatura ambiente-20°C ~ 55 °C (Operating)Derating is recommended for extreme conditions

Características Elétricas

ParâmetroValorObservações
Tensão nominal de controle24Em DC (-15%/+10%)20.4V~26.4V
Typical Power Consumption1.32CAprox.. 55mA current consumption
Typical Pick-up / Drop-out Time50EM / 50EMStandard response speed
Redefinir horaSafety state recovery time
Max Switching Frequency0.5HzSuitable for low-frequency safety switching applications
Proteção contra surtosSuppression Diode (33V, A1-A2)Built-in protection circuit
Operation Indication1× Yellow LEDVisual power status indication

Contact Parameters

Tipo de contatoQuantidadeMax Switching VoltageCorrente contínua máximaMax Rated Power
Normally Open Safety Contact2 canais250V CA/CC5UM1250VA (AC) / 120C (CC)
Normally Closed Signal Contact1 canal250V CA/CC100mA25VA (AC) / 22C (CC)
Contact Material-AgCuNi + 0.2µm Gold PlatingImprove conductivity and corrosion resistance
Min Switching Voltage-15V CA/CCEnsure reliable switching for low-level signals

Conexão & Montagem

ParâmetroValorObservações
Tipo de conexãoPluggable Push-in TerminalFast wiring, fácil manutenção
Seção transversal do condutor0.2mm~1.5mm (Solid/Flexible)AWG 24~16
Stripping Length8milímetrosStandard wire stripping length
Tipo de montagemMontagem em trilho DINCompliant with EN 60715 trilho padrão
Posição de montagemAny orientationNo installation direction restriction
  1. Lista de acessórios
Nome do acessórioNúmero da peça.Aplicativo
CRIMPFOX 6 Crimping Tool1212034Crimping tool for flexible conductors with wire end ferrules
PSR-ESS-ACC-CB1-C3 Module Bracket1221747Fix and combine multiple PSR modules
PACKB.PSR-24DC/FSP2/2X1/1X2 Package9052052Original product package including installation manual
PSR-ESS-M0-H110 Actuator1221757Actuator matched with safety relay
  1. Alternativa & Comparação entre marcas
MarcaModeloNível de segurançaConfiguração de contatoLarguraCenário de aplicação
Contato FênixPSR-SCP-24DC/FSP2/2X1/1X2 (2986575)SIL 22NÃO+1NC17.5milímetrosAlternative to PSR-SPP series; SCP = Screw terminal version
Siemens3TK2825-1BB40SIL 22NÃO+1NC22.5milímetrosSafety coupling relay, 24Em DC, screw terminal
SchneiderXPSBC3121SIL 22NÃO+1NC22.5milímetrosSafety coupling relay, 24Em DC, spring terminal
OmronG9SA-321-T075SIL 22NÃO+1NC22.5milímetrosSafety relay module, 24Em DC, screw terminal
Contato FênixPSR-SPP-24DC/FSP/2X1/1X2 (2986957)SIL 32NÃO+1NC17.5milímetrosUpgraded replacement with higher safety level
  1. Diretrizes de seleção & Soluções Alternativas

Árvore de decisão de seleção

  1. Safety Level Matching: Confirm required SIL level for the application (this model fits SIL 2); for SIL 3, select PSR-SPP-24DC/FSP/2X1/1X2 (2986957).
  2. Contact Configuration Requirement: Verify whether 2NO+1NC meets control loop demands; select expansion modules if more contacts are needed.
  3. Wiring Preference: Choose Push-in (SPP) vs Screw (SCP) terminals according to wiring habits and vibration environment.
  4. Space Limitation: 17.5mm slim design for compact cabinets; 22.5mm series available if space is sufficient.
  5. Diagnostic Requirement: Integrated test pulse filter simplifies validation testing per IEC 61508.

Alternative Recommendation

Requirement ChangeModelo Alternativo RecomendadoVantagem
Upgrade to SIL 3PSR-SPP-24DC/FSP/2X1/1X2 (2986957)Higher safety integrity for more demanding applications
Screw Terminal VersionPSR-SCP-24DC/FSP2/2X1/1X2 (2986575)More stable connection, suitable for vibration environments
More Normally Open ContactsPSR-SPP-24DC/FSP/3X1/1X23NO+1NC for expanded control capability
Lower Power ConsumptionPSR-SPP-24DC/FSP2/2X1/1X2-LPLow-power version, ideal for battery-powered systems
Expansão ModularPSR-SPP-24DC/URML4/3X1/1X2/B (2903584)Contact expansion module for combination with main unit
  1. Partial Full Model List of PSR-SPP Series Safety Coupling Relays
ModeloNúmero da peça.Nível de segurançaConfiguração de contatoCaracterísticas
PSR-SPP-24DC/FSP/1X1/1X22981981SIL 31NÃO+1NC1 safety NO contact + 1 signal NC contact
PSR-SPP-24DC/FSP/2X1/1X22986957SIL 32NÃO+1NC2 safety NO contacts + 1 signal NC contact
PSR-SPP-24DC/FSP2/2X1/1X22986588SIL 22NÃO+1NCIntegrated test pulse filter for SIL 2 applications
PSR-SPP-24DC/FSP/3X1/1X22986958SIL 33NÃO+1NC3 safety NO contacts + 1 signal NC contact
PSR-SPP-24UC/FSP/2X1/1X22986959SIL 32NÃO+1NC24V AC/DC universal voltage for multi-power environments
PSR-SPP-48DC/FSP/2X1/1X22986961SIL 32NÃO+1NC48V DC control voltage for specific industrial systems

Cenários de aplicativos principais

PLC Digital Output Safety Isolation: Convert standard PLC digital output to SIL 2 safety signal.

Safe Shutdown Control: Applicable to safety doors, emergency stop buttons and other safety disconnection occasions.

Test Pulse Compatible System: Built-in test pulse filter, compatible with safety controllers with test pulse function.

Industrial Automation Safety Loop: Provide safety redundant control for production lines, robôs, packaging machinery and other equipment.

Full Model List of Phoenix Contact Safety Relays (Authoritative Classification Version)

  1. Visão geral da série de produtos

Phoenix Contact safety relays are mainly divided into 5 série, covering full application demands from compact fixed-function to programmable modular systems:

SérieCaracterísticasLarguraNível de segurançaAplicativo principal
PSRclassicTraditional type, funções completas, industry standard designFrom 17.5mmSIL 2/3, PL c/eEmergency stop, porta de segurança, light curtain, two-hand control
PSRminiUltra-slim design, saves 70% space6milímetros / 12milímetrosSIL 2/3, PL c/eSpace-limited small equipment
PSRcompactCompact type, high integrationFrom 12.5mmSIL 2/3, PL c/eStandard safety functions with cost performance
PSRmodularProgrammable safety system, expansão flexívelFrom 17.5mmSIL 3, PL eComplex safety control, multi-axis motion monitoring
Safety Coupling RelaySafety isolation for digital output signals17.5milímetrosSIL 2/3PLC output to safety loop conversion
  1. PSRclassic Series (Traditional Safety Relay)

2.1 Parada de Emergência / Safety Door Monitoring (Modelos principais)

ModeloNúmero da peça.Nível de segurançaConfiguração de contatoTensão de controleTipo de conexãoCaracterísticas
PSR-SCP-24DC/ESA4/2X1/1X22981019SIL 3, PL e2NÃO+1NC24Em DCScrew TerminalDual-channel, auto/manual reset, cross-circuit detection
PSR-SPP-24DC/ESA4/2X1/1X22981021SIL 3, PL e2NÃO+1NC24Em DCPlug-in Push-inIgual ao acima, push-in wiring for easy maintenance
PSR-SCP-24UC/ESA4/3X1/1X2/B2963763SIL 3, PL e3NÃO+1NC24V CA/CCScrew TerminalWith expansion interface, 3 safety contacts
PSR-SPP-24UC/ESAM4/2X1/1X22900526SIL 3, PL e2NÃO+1NC24V CA/CCPlug-in Push-inDual-channel, reinicialização manual, start monitoring
PSR-SCP-24DC/ESP4/2X1/1X22981020SIL 3, PL e2NÃO+1NC24Em DCScrew TerminalWith test pulse, suitable for light curtain / safety mat

2.2 Two-Hand Control Type

ModeloNúmero da peça.Nível de segurançaConfiguração de contatoTensão de controleCaracterísticas
PSR-SCP-24DC/2HS4/2X1/1X22981022SIL 3, PL e2NÃO+1NC24Em DCTwo-hand control, dual-channel, auto reset
PSR-SPP-24DC/2HS4/2X1/1X22981023SIL 3, PL e2NÃO+1NC24Em DCTwo-hand control, pluggable push-in terminal
PSR-SCP-48DC/2HS4/3X1/1X22981024SIL 3, PL e3NÃO+1NC48Em DCTwo-hand control with 3 safety contacts

2.3 Test Pulse Compatible Type (FSP Series)

ModeloNúmero da peça.Nível de segurançaConfiguração de contatoTensão de controleCaracterísticas
PSR-SPP-24DC/FSP2/2X1/1X22986588SIL 22NÃO+1NC24Em DCIntegrated test pulse filter for SIL 2
PSR-SPP-24DC/FSP/2X1/1X22986957SIL 32NÃO+1NC24Em DCTest pulse compatible, SIL 3 nível
PSR-SCP-24DC/FSP2/2X1/1X22986575SIL 22NÃO+1NC24Em DCScrew terminal version with test pulse filter
  1. PSRmini Series (Ultra-Slim Safety Relay, 6mm/12mm)

3.1 6mm Ultra-Slim Basic Type

ModeloNúmero da peça.Nível de segurançaConfiguração de contatoTensão de controleLarguraCaracterísticas
PSRmini-6-24DC/1NO/1NC2963912SIL 2, PL c1NÃO+1NC24Em DC6milímetros1 safety contact + 1 signal contact
PSRmini-6-24DC/2NO2963913SIL 2, PL c2NÃO24Em DC6milímetros2 normally open safety contacts
PSRmini-6-24UC/1NO/1NC2963914SIL 2, PL c1NÃO+1NC24V CA/CC6milímetrosUniversal voltage, economia de espaço

3.2 12mm Extended Type

ModeloNúmero da peça.Nível de segurançaConfiguração de contatoTensão de controleLarguraCaracterísticas
PSRmini-12-24DC/2NO/1NC2963915SIL 3, PL e2NÃO+1NC24Em DC12milímetros2 safety contacts + 1 signal contact
PSRmini-12-24DC/3NO2963916SIL 3, PL e3NÃO24Em DC12milímetros3 normally open safety contacts
PSRmini-12-48DC/2NO/1NC2963917SIL 3, PL e2NÃO+1NC48Em DC12milímetros48V DC control for specific systems
  1. Safety Coupling Relay (PSR-PS Series)

Used for safety isolation of PLC digital output signals, converting standard output to safety signal.

ModeloNúmero da peça.Nível de segurançaConfiguração de contatoTensão de controleTipo de conexãoCaracterísticas
PSR-PS22-1NO-1NC-24VDC-SC2702524SIL 31NÃO+1NC24Em DCScrew Terminal1 enable current, 1 confirm current
PSR-PS23-1NO-1NC-24VDC-SC2702663SIL 31NÃO+1NC24Em DCScrew TerminalWith test pulse filter, safe shutdown
PSR-PS24-2NO-1NC-24VDC-PI2702664SIL 32NÃO+1NC24Em DCPlug-in Push-in2 enable current, 1 confirm current
PSR-PS25-1NO-2NC-24VDC-SC2702665SIL 31NÃO+2NC24Em DCScrew Terminal1 enable, 2 signal feedback
  1. PSRmotion Series (Speed Monitoring Safety Relay)

Applied to zero-speed / overspeed monitoring for rotating equipment protection.

ModeloNúmero da peça.Nível de segurançaFunção de monitoramentoTipo de entradaConfiguração de contato
PSR-MM20-2NO-1DO-24DC-SP2702375SIL 3, PL eVelocidade / Zero Speed2 Proximity Sensors2NO+1DO
PSR-MM21-2NO-1DO-24DC-SP2702376SIL 3, PL eOverspeed1 Codificador2NO+1DO
PSR-MM22-2NO-1DO-24DC-SP2702377SIL 3, PL eUnderspeed1 Codificador2NO+1DO
PSR-MM23-2NO-1DO-24DC-SP2702378SIL 3, PL eSpeed Range1 Codificador2NO+1DO
  1. PSR-M Series (Configurable Safety Module)

Flexible safety function configuration, supporting multiple safety I/O combinations.

ModeloNúmero da peça.Nível de segurançaEntrada / SaídaCaracterísticas
PSR-MC34-3NO-1DO-24DC-SP2700548SIL 3, PL eDual-channel Input, 3NO+1DOEmergency stop / porta de segurança, cross-circuit detection
PSR-MC38-2NO-1DO-24DC-PI1009832SIL 3, PL eDual-channel Input, 2NO+1DOPlug-in push-in, auto/manual reset
PSR-UNI-L-2X2NO-2DO-24DC-SC-SIL 3, PL e2-channel Input, 4NO+2DOMulti-function with configurable safety logic
PSR-UNI-L-1X4NO-1DO-24DC-PI1487648SIL 3, PL e1-channel Input, 4NO+1DOSingle-channel operation, 4 safety contacts
  1. PSRmodular Series (Programmable Safety System)

Highly flexible modular safety control system supporting distributed configuration.

Tipo de móduloExemplo de modeloNúmero da peça.FunçãoNível de segurança
Main ModulePSR-M-M30-0000-00001091000System control, até 8 safety functionsSIL 3, PL e
Entrada DigitalPSR-M-EF1-SDI8-SDO4-DO4-PI11049858DI+4SDO+4DOSIL 3
Entrada AnalógicaPSR-M-EF7-SAI4-PI11049864-channel safety analog input (0-10V)SIL 3
Motion MonitoringPSR-M-EF8-MOT2-PI11049872-axis speed / position monitoringSIL 3
Gateway ModulePSR-M-GW-PROFNET1104988PROFINET communication interfaceSIL 3
  1. Guia de seleção rápida
  2. Selection by Safety Level

SIL 2 Aplicativo: Choose models with suffix FSP2 (por exemplo. PSR-SPP-24DC/FSP2/2X1/1X2)

SIL 3 Aplicativo: Choose models with suffix FSP/ESA/ESAM/2HS (por exemplo. PSR-SPP-24DC/FSP/2X1/1X2)

  1. Selection by Connection Type

SPP: Plug-in Push-in Terminal (Fast wiring, suitable for frequent maintenance)

SCP: Screw Terminal (Reliable connection, suitable for vibration environment)

PI: Push-in Terminal (Tool-free quick installation)

  1. Seection by Space Requirement

Ultracompacto: PSRmini Series (6milímetros / 12milímetros)

Standard Cabinet: PSRclassic Series (17.5milímetros)

Complex System: PSRmodular Series (Modular combination)

  1. Selection by Functional Requirement

Parada de Emergência / Safety Door: ESA / ESAM Series

Two-Hand Control: 2HS Series

Test Pulse Compatibility: FSP / FSP2 Series

Speed Monitoring: PSRmotion Series

PLC Signal Isolation: PSR-PS Series