Servo Drive Yaskawa SGDV-5R4D01A - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 Servo Drive Yaskawa SGDV-5R4D01A - Contator,disjuntor,sensor,Codificador,CLP,Conversor

CLP/

Servo Drive Yaskawa SGDV-5R4D01A

400Classe V, MECHATROLINK-II bus-type servo drive. Max compatible with Yaskawa Σ-V 1.5kW servo motors. Classic legacy Yaskawa servo, descontinuado; new units are no longer actively promoted. Análise do modelo: SGDV-5R4D01A Field Definition SGDV -V series SERVOPACK servo unit 5R4 Rated continuous output current 5.4A D 3-phase 400V (380~480VAC) main power supply specification 1 Command interface: MECHATROLINK-II bus communication ...

  • Detalhes do produto

400Classe V, MECHATROLINK-II bus-type servo drive. Max compatible with Yaskawa Σ-V 1.5kW servomotores. Classic legacy Yaskawa servo, descontinuado; new units are no longer actively promoted.

  1. Análise do modelo: SGDV-5R4D01A
CampoDefinição
SGDV-V series SERVOPACK servo unit
5R4Rated continuous output current 5.4A
D3-fase 400V (380~480VAC) main power supply specification
1Command interface: MECHATROLINK-II bus communication type
UMEspecificação padrão, no optional modules
  1. Especificações elétricas principais

Main circuit power: 3-phase AC380~480V, +10%/-15%, 50/60Hz

Fonte de alimentação de controle: CC24V

Corrente de saída contínua: 5.4 Arms

Maximum instantaneous output current: 14 Arms

Compatible motor rated power: 1.5kW (SGMGV / SGMSV 400V series motors)

Largura de banda do loop de velocidade: 1.6kHz, built-in vibration suppression, real-time adaptive tuning (Tuningless)

Regenerative resistor: Internal regenerative resistor equipped; external regenerative resistor available for heavy braking applications (terminals B1/B2. Remove B2-B3 shorting link)

Feedback do codificador: Supports incremental encoder; full-closed loop optional module can be installed

Comunicação: MECHATROLINK-II, rotary switch for station number setting

  1. Interface & Descrição do terminal
  2. CN1: Motor encoder cable connector
  3. CN3 / CN7: MECHATROLINK-II bus (ENTRADA/SAÍDA, daisy-chain wiring)
  4. CN2: Safety terminal (Torque seguro STO desativado)
  5. Terminais do circuito principal: R/S/T 3-phase input; U/V/W motor connection; P/N DC bus; B1/B2/B3 regenerative resistor terminals
  6. Painel frontal: 7-exibição de segmento + POWER/COM indicators, SW1 rotary switch (número da estação), SW2 DIP switch
  7. Aplicações Típicas

Machine tool feed axes, máquinas de embalagem, máquinas têxteis, handling robots, máquinas de corte, multi-axis synchronous production lines, multi-axis MECHATROLINK-II bus control systems.

  1. Opções de substituição (Discontinued Model Selection)
  2. Substituição da mesma série (Compatible with original MECHATROLINK-II): SGDV-5R4D05A (optional variant, spare part replacement only)
  3. New-generation Σ7 series recommendation: SGD7S-120D10A (400V 1.5kW, MECHATROLINK III; different bus protocol, PLC program and cables require modification)
  4. Alternativas domésticas: Inovance IS650, HCFA X3 400V-class 1.5kW bus servo. Motor parameters and communication need re-commissioning.
  5. Instalação & Diretrizes de Manutenção
  6. High voltage remains in capacitors after power-off. Espere pelo menos 5 minutes after power cut before opening the cover. Confirm the Charge lamp is extinguished.
  7. Vertically mount inside control cabinet; reserve ventilation space top and bottom to avoid overheating caused by dust accumulation.
  8. Motor power cable and encoder cable must be shielded with single-end grounding to reduce bus interference.
  9. Regenerative circuit: Use internal resistor for normal operation. For frequent emergency stop / high deceleration loads, connect external braking resistor and modify resistor rating in parameter Pn600.
  10. Alarmes Comuns (SGDV Σ-V)

A.100: Sobrecorrente / Heat sink overheat

A.400: Sobretensão (Excessive deceleration, insufficient regenerative resistance)

A.410: Main circuit undervoltage

A.C90: Drive overheating

A.810 / A.820: MECHATROLINK-II communication fault. Check bus wiring, número da estação, resistor de terminação.

UM.020: Parameter corruption. Restore factory defaults and reconfigure motor parameters.

  1. Recommended Matching Motor

SGMGV-13D (400V, 1.5kW, inércia média, most commonly matched motor)

SGDV-5R4D01A (MECHATROLINK-II Σ-V) Factory Parameter Backup List

Motor combinado: SGMGV-13D (400V 1.5kW). This checklist is used for spare part replacement, whole machine backup and fault recovery. Categorias: [Basic Core Parameters] [MECHATROLINK-II Bus Parameters] [Gain & Afinação] [Regeneration / Parâmetros de proteção] [Codificador & Configurações da unidade] [Alarmes & Funções]

Backup recommendation: Read online and save project file via SigmaWin+ software. Manual panel entry is only for paper backup.

  1. Basic Setting Parameters (Pn0xx)
Parâmetro Não.Nome do parâmetroPadrão de fábricaObservações
Pn000Seleção do modo de controlen.0010MECHATROLINK-II bus position control
Pn001Motor CodeAuto detected by motorAutomatically loaded on power-up for SGMGV-13D. Must reset when replacing motor
Pn002Encoder Type Selectionn.0000Incremental encoder; n.0001=Absolute encoder
Pn003Direção de rotaçãon.0000CCW as positive direction
Pn004Servo ON At Power-upn.0000Servo ON command from host controller
Pn008Velocidade nominal do motor3000Rated motor speed r/min
Pn009Corrente nominal do motor4.4UMCorrente nominal do motor
  1. MECHATROLINK-II Bus Communication Parameters (Pn8xx / Switches)
Parâmetro Não.Nome do parâmetroPadrão de fábricaObservações
SW1 Rotary SwitchMECHATROLINK Station Number00~F, station address 1~16; hardware switch priority higher than parameters
Pn800MECHATROLINK Cycle Time0.5EMBus communication cycle, critical for multi-axis synchronization
Pn801Communication Watchdog Time50Communication timeout in ms. A.810 triggered upon timeout
Pn802Command Selectionn.0000MECHATROLINK position command
Pn810Resistor de Terminaçãon.0000Drive internal termination resistor OFF; set to n.0001 for last axis on bus
  1. Position Unit & Resolução do codificador (Pn2xx)
Parâmetro Não.Nome do parâmetroPadrão de fábricaObservações
Pn202Resolução do codificador104857617-codificador de bits, 1048576 pulse/rev
Pn20EElectronic Gear Numerator1Electronic gear ratio numerator
Pn210Electronic Gear Denominator1Electronic gear ratio denominator; adjust according to mechanical setup
Pn212Positive Soft LimitNo limitMechanical soft limit, configure as required
Pn213Negative Soft LimitNo limit
  1. Regenerative Braking & Protection Limit Parameters (Pn6xx, Pn4xx)
Parâmetro Não.Nome do parâmetroPadrão de fábricaDescrição
Pn600Regenerative Resistor Capacity40CSGDV-5R4D01A built-in regenerative resistor 40W; must modify for external resistor
Pn601Regenerative Resistor Resistance100masInternal resistor resistance
Pn400Positive Torque Limit100%Maximum output torque
Pn401Negative Torque Limit100%
Pn408Overload Warning Threshold80%Overload pre-warning
Pn501Torque seguro STO desativadon.0000STO terminals active
  1. I/O Signal Assignment (Pn3xx, CN2 Terminal)
Parâmetro Não.Nome do parâmetroPadrão de fábrica
Pn300Sinal de saída 1 Assignmentn.0001ALM Alarm Output
Pn301Sinal de saída 2 Assignmentn.0004S-RDY Servo Ready
Pn302Sinal de saída 3 Assignmentn.0005COIN Positioning Complete
Pn310Input Signal Logicn.0000Normally Open Logic
  1. Monitor Parameters (Somente leitura, backup for fault comparison)

Un000: Motor Speed

Un001: Motor Current

Un002: Bus Voltage

Un003: Load Factor

Un00C: MECHATROLINK Communication Status

Un010: Código de alarme

  1. Alarm History & Function Menu Fn (Non-storable parameters, record reference)

Fn000: View Alarm History

Fn005: Write Parameters to ROM (Mandatory after parameter modification!)

Fn006: Operação Servo JOG

Fn009: Inicialização de fábrica (Restaure todos os parâmetros para o padrão de fábrica)

⚠️Importante: Após a inicialização do Fn009, o código do motor Pn001 é apagado; a identificação do motor deve ser executada novamente!

  1. Backup & Procedimentos de restauração (Papel + Backup duplo de software)

1) Backup

  1. Ligar, Servo desligado; conectar via SigmaWin+
  2. Leia todos os parâmetros e salve o arquivo do projeto (.wpj)
  3. Registrar parâmetros da tabela; registrar relação de transmissão eletrônica, número da estação e status do resistor de terminação
  4. Exportar histórico de alarmes via Fn000

2) Restaurar (Substituição da unidade SGDV-5R4D01A)

  1. Ligar, execute a redefinição de fábrica do Fn009 primeiro
  2. Escreva o código do motor Pn001, ciclo de energia
  3. Importar parâmetros completos de backup
  4. Defina o número da estação MECHATROLINK e o resistor de terminação
  5. Execute Fn005 para salvar parâmetros na ROM
  6. Corpo JOG, confirme a ausência de alarmes e a comunicação normal do barramento
  7. Notas
  8. SGDV-5R4D01A é a versão MECHATROLINK-II. Não confunda com SGDV tipo pulso. Modo de controle Pn000 errado acionará alarme de comunicação A.810.
  9. 400Em unidades: Fonte de controle DC24V, 3-phase 380~480V main circuit. Power sequence: Apply 24V control power first, then main circuit power.
  10. For drive replacement: SW1 rotary station number is hardware-prioritized. Software station number setting does not take effect.
  11. When external regenerative resistor is installed, Pn600/Pn601 must be updated. Otherwise A.400 overvoltage alarm may occur and damage regenerative circuit.

Anterior:

Próximo:

Deixe uma resposta