T6V 800 PR221DS|ABB Tmax T6 Series High Performance Moulded Case Circuit Breaker (MCCB)
Model complet: T6V 800 PR221DS-LS/I In=800 (Codurile comune de comandă: 1SDA069432R1, 1SDA069429R1, 3P/4P selectable)
Marca: ABB (SACE Tmax Series)
- Detailed Model Interpretation
| Segmentul de model | Sens | Descrierea cheii |
| T6 | Series Designation | Tmax T6 series, frame current 800A, suitable for medium and high voltage power distribution systems |
| V | Clasa de capacitate de rupere | Class V, ultra-high breaking capacity: 120kA at 400V, 200kA at 220V |
| 800 | Curent nominal | 800O (same as frame current) |
| PR221DS | Tip unitate de deplasare | Electronic intelligent trip unit with LS/I protection (Long-time delay L, Short-time delay S, I instantaneu) |
| LS/I | Configurație de protecție | Standard three-stage protection; earth fault protection optional (extra configuration required) |
| F F | Montare / Conexiune | First F: Montaj fix; Second F: Conexiune frontală |
- Parametrii tehnici de bază
| Articol | Caietul de sarcini | Observații |
| Tensiune nominală (Ue) | 690V și | Suitable for industrial high-voltage power distribution systems |
| Tensiune nominală de izolație (Ui) | 1000V și | Higher than rated operating voltage, large safety margin |
| Capacitate maximă de rupere (Icu) | 120kA@400V, 200kA@220V | Highest Class V, potrivit pentru medii industriale dure |
| Curent nominal de funcționare (În) | 800O | Maximum continuous operating current |
| Polonii | 3P/4P selectable | 3P for three-phase circuits, 4P include protecția neutră |
| Trip Characteristic | LS/I three-stage protection | Long-time delay inverse time, de scurtă durată / instantaneous definite time |
| Tip de montare | Fix | Draw-out type also available (special model required) |
| Tip conexiune | Conexiune frontală | Compatible with cables or busbars |
| Grad de protecție | IP30 | Standard switchgear installation protection |
| Standard aplicabil | IEC 60947-2 | International standard for low-voltage switchgear |
- Caracteristici cheie & Aplicații
Avantajele de bază
- Ultra-high breaking capacity: Class V can withstand severe short-circuit faults and ensure system safety
- Intelligent protection: PR221DS trip unit provides accurate overload and short-circuit protection with adjustable parameters
- Fiabil și durabil: ABB Tmax series design, suitable for frequent operation and harsh industrial environments
- Flexible extension: Supports various accessories (contacte auxiliare, contacte de alarmă, declanșare la subtensiune, etc.)
Aplicații tipice
Main power distribution systems in large industrial plants
690V high-voltage Motor Control Centers (MCC)
Power supply for data centers and critical infrastructure
Combiner box protection for new energy power systems (PV, wind power)
Marine and offshore platform power distribution systems
- Reference Replacement Models
Same-brand Upgrades / Înlocuitori
| Model | Capacitate de rupere | Tip de călătorie | Aplicație |
| T6V 800 PR222DS-LSIG | 120kA@400V | With earth fault protection (G) | Systems requiring earth fault detection |
| T6V 800 PR223DS | 120kA@400V | Advanced intelligent trip unit | Applications requiring remote monitoring and communication |
| T6S 800 PR221DS | 70kA@400V | Capacitate de rupere standard | General industrial power distribution, cost mai mic |
Alternative cross-brand
| Marca | Model | Parametrii cheie de potrivire |
| Schneider | Masterpact MT25H1 800A | 800O, 120kA rupere, three-stage protection |
| Siemens | 3WL1210-3BB36-4GA4 | 800O, 100kA rupere, intelligent trip unit |
| Mitsubishi | NF800-SEW | 800O, 100kA rupere, electronic trip unit |
- Note de selecție
- Potrivirea capacității de rupere: Select V/S/H/N/L classes based on system short-circuit current calculation
- Protection function selection: Basic LS/I meets most needs; choose LSIG for earth fault protection
- Tip de montare: Fixed for standard switchgear, draw-out for easy maintenance and replacement
- Configurare accesorii: Select auxiliary contacts, contacte de alarmă, operatori cu motor, etc., according to control requirements
- Voltage compatibility: T6V suitable for systems up to 690V; use dedicated 1000V series (de ex., T6L) for higher voltages
Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare