Prezentare generală a produsului & Explicația modelului
ACS 310-01E-02A4-2 is a invertor de uz general from the ABB ACS310 series with single-phase 230 V input and three-phase output. It is mainly designed for variable-torque applications such as fans and pumps, with IP20 protection and C3 EMC filter compatibility.
Defalcarea codului de model (ABB ACS310 Naming Convention)
| Cod | Sens | Descriere |
| ACS 310 | Basic series | ACS310 = general-purpose inverter, optimized for fan & pump variable-torque loads |
| 01E | Cadru & incintă | 01 = Frame R1; E = IP20, no built-in filter (external filter required) |
| 02A4 | Rated output & Voltaj | 02A = rated output current 2.4 O (0.37 kW); 4 = voltage class (200–240 V) |
| 2 | Input phase | 2 = single-phase input (200–240 V), three-phase 200–240 V output |
- Specificații tehnice de bază
2.1 Date electrice
| Articol | Caietul de sarcini |
| Input power | Single-phase 200–240 V AC, 50/60 Hz, ±10% toleranță |
| Ieșire | Three-phase 0–240 V AC, 0–500 Hz, 0.37 kW / 2.4 O, 150% suprasarcina pentru 60 s |
| Modul de control | control V/f (flux vector optional), built-in PID and PFC (pump/fan control) |
| I/O digitală | 2 intrări digitale, 1 ieșire releu (250 V AC/2 A, 30 V DC/2 A) |
| Analog I/O | 1 intrare analogică (0–10 V or 4–20 mA), 1 ieșire analogică (0-20 mA) |
| Comunicare | Built-in Modbus EIA-485, Modbus RTU acceptat |
| EMC | Category C3 (mediu industrial), external filter required |
2.2 Caracteristici mecanice
| Articol | Caietul de sarcini |
| Cadru | R1 (132 × 175 × 155 mm, L × H × D) |
| Montare | Wall or cabinet mounting, vertical installation; ≥100 mm clearance top & bottom |
| Protecţie | IP20 |
| Temperatură | Funcționează: -10 °C până la +40 °C (derate above 40 °C); Depozitare: -40 °C până la +70 °C |
| Greutate | Aproximativ. 1.5 kg |
| Răcire | Natural convection (no fan) |
- Key Functions & Aplicații
3.1 Ventilator & Pump Special Functions
Built-in multi-pump control (până la 4 pompe), alternation and automatic backup
Pipe cleaning and priming functions for system commissioning and maintenance
Sleep / wake-up function for significant energy saving
Anti-blockage and dry-run protection for pumps
Motor noise smoothing to reduce noise
3.2 Aplicații tipice
| Aplicație | Suitable Equipment | Key Benefits |
| sisteme HVAC | Ventilatoare centrifuge, pompe, cooling tower fans | 30–50% energy saving, stable, zgomot redus |
| Tratarea apei | Pompe de rapel, submersible pumps, pompe de canalizare | Dry-run protection, control cu mai multe pompe |
| Industrial circuits | Cooling pumps, lubrication pumps | Longer service life, lower maintenance |
| Mașini mici | Transportoare, mixere, small compressors | Easy to use, rentabil |
- Series Models & Alternative
4.1 ACS310 Series (Frame R1, 200–240 V single-phase)
| Model | Putere nominală | Curent nominal | Diferența principală | Aplicație |
| ACS310-01E-02A4-2 | 0.37 kW | 2.4 O | Model de bază | Mici fani, micro pumps |
| ACS310-01E-04A7-2 | 0.75 kW | 4.7 O | Higher power | Small/medium fans & pompe |
| ACS310-01E-07A5-2 | 1.5 kW | 7.5 O | Higher power | Medium fans & pompe |
| ACS310-01E-09A8-2 | 2.2 kW | 9.8 O | Higher power | Ventilatoare mari & pompe |
4.2 Alternative recomandate
| Alternativă | Diferența principală | Aplicație |
| ACS310-03E-02A4-4 | Three-phase 380–480 V input, 0.37 kW | Industrial three-phase systems |
| ACS355-01E-02A4-2 | Full-featured, filtru EMC încorporat | Higher EMC & functional requirements |
| ACS580-01-03A3-4 | Controlul vectorial, 180% suprasarcina | High dynamic & control de precizie |
- Accesorii & Opțiuni
| Accesorii | Cod tip | Descriere |
| Control panel | CDP312R | Basic control and parameter setting |
| Advanced panel | CDP312R-ETH | Cu Ethernet, monitorizare de la distanță |
| filtru EMC | 3AFE68300909 | C3 EMC filter for industrial environment |
| Unitate de frână | ACS-BU-01 | For frequent start/stop and braking |
| I/O extension | 3AXD50000038762 | 4 DIN + 2 DO expansion |
| Comm module | 3AXD50000038763 | Profibus-DP interface |
- Instalare & Depanare
6.1 Note de instalare
- Electrical installation
Input must be protected by a circuit breaker and fuse matching 2.4 O
Output cable: shielded, max. 50 m to prevent motor overvoltage
Separate control wiring from power wiring by ≥100 mm
- Mechanical installation
Mount vertically with sufficient ventilation
Derate 1% per °C above 40 °C
Avoid high vibration, praf, moisture, gaz corosiv
6.2 Fault Codes
| Cod | Descriere | Cauza posibila | Soluţie |
| F001 | Supracurent | Scurt-circuit, motor overload, wrong settings | Verificați cablajul, reduce load, reset parameters |
| F002 | Supratensiune | High supply voltage, fast deceleration | Check supply, adjust deceleration time |
| F003 | Subtensiune | Low voltage, pierdere de fază | Check input power |
| F004 | Overtemperature | Ventilatie slaba, blocked heatsink | Îmbunătățiți răcirea, clean heatsink |
| F005 | Suprasarcina motorului | Excess load, stand | Reduceți sarcina, check motor |
| F006 | Defecțiune la pământ | Output grounded, motor insulation fault | Check cable and motor |
- Selecţie & Application Advice
- By load type
Fan/pump variable-torque loads: ACS310 series recommended
Constant-torque loads (transportoare, mixere): ACS355 or ACS580
- By power
≤ 0.37 kW: ACS310-01E-02A4-2
0.37–2.2 kW: ACS310-01E series
> 2.2 kW: ACS310-03E three-phase series
- Energy-saving analysis
Fans and pumps can save 30–50% energy with VFD control
Use ABB DriveSize for accurate selection and energy calculation
As an entry-level model of the ABB ACS310 series, the ACS 310-01E-02A4-2 features compact design, operare usoara, and fan/pump‑optimized functions, making it an ideal choice for small industrial and commercial applications. For advanced control or higher performance, upgrade to ACS355 or ACS580 series.