Carlo Gavazzi VNY 4 NS/NT Conductive Level Sensor (Item No.: 481046)
| Segmentul de model | Descriere |
| VNY | Seria de produse: Conductive level probe; VNY series features threaded connection with PBTP housing and non-insulated electrodes |
| 4 | Electrode quantity: 4 electrodes, supporting multi-level monitoring (Ridicat / Mediu / Scăzut / Ultra-low) |
| NS | Electrode type: Non-Isolated, suitable for general conductive liquid measurement |
| NT | Tip conexiune: Borne cu șuruburi, convenient for field wiring |
| 481046 | Global unique item / order number, official Carlo Gavazzi part identifier |
- Full Core Technical Specifications
| Categoria parametrilor | Specificații | Observații |
| Basic Info | Conductive level sensor for multi-point level control of conductive liquids | Must be used with amplifier relays (SV series, S195/196, ELA/ELC/ELD) |
| Comanda nr. | 481046 (corresponds to model VNY 4 NS/NT) | Order strictly by this part number |
| Producător | Carlo Gavazzi | Well-known brand in industrial automation sensors |
| Electrode Configuration | 4 non-insulated electrodes, AISI316 stainless steel (DIN1.4401) | Diameter 5mm, standard length 100cm (field-cuttable) |
| Materialul carcasei | PBTP engineering plastic | Corrosion-resistant for industrial environments |
| Tip de montare | 1 1/2″ pipe thread (ISO 228/1-G1 1/2″) | Standard industrial pipeline mounting, fixed with VM15 nut |
| Metoda de conectare | Conexiune terminală cu șurub (NT) | More suitable for vibrating environments than cable connection, easy maintenance |
| Protecție la intrare | IP67 | Dust-tight and waterproof, submersible in liquid |
| Temperatura de operare | 0°C ~ 90°C (32°F ~ 194°F) | Compatible with most industrial liquid temperature ranges |
| Temperatura de depozitare | -25°C ~ 100°C (-13°F ~ 212°F) | Adaptable to extreme transportation and storage conditions |
| Working Pressure | 10 bar (@ 60°C) | Suitable for medium and high-pressure tank applications |
| Specificația cablului | No built-in cable (screw terminal type) | Customer-supplied cable recommended; shielded cable preferred to reduce interference |
| Certificari | CE certified (conform cu IEC 529) | Meets EU industrial safety requirements |
| Dimensiuni | Electrode diameter 5mm, total length approx. 100cm | Electrode length can be cut on-site according to actual liquid level |
| Greutate | Aproximativ. 0.8kg | Lightweight design for easy installation and maintenance |
- VNY Series Full Model List
| Item No. | Model | Electrode Qty | Electrode Type | Tip conexiune | Materialul carcasei | Mounting Thread | Caracteristici speciale |
| 481046 | VNY 4 NS/NT | 4 | Non-Isolated (NS) | Terminal cu șurub (NT) | PBTP | 1 1/2″ | Multi-level control, general industrial use |
| 481043 | VNY 1 NS/NT | 1 | Non-Isolated (NS) | Terminal cu șurub (NT) | PBTP | 1 1/2″ | Single-point level detection, rentabil |
| 481044 | VNY 2 NS/NT | 2 | Non-Isolated (NS) | Terminal cu șurub (NT) | PBTP | 1 1/2″ | Two-point high/low level control |
| 481045 | VNY 3 NS/NT | 3 | Non-Isolated (NS) | Terminal cu șurub (NT) | PBTP | 1 1/2″ | Three-point high/medium/low level control |
| 481047 | VNYI 4 IS/NT | 4 | Insulated (IS) | Terminal cu șurub (NT) | PBTP | 1 1/2″ | PE insulated electrodes, anti-clinging liquid interference |
| 481042 | VNY 1 NS/CB | 1 | Non-Isolated (NS) | Cable Connection (CB) | PBTP | 1 1/2″ | 2m fixed cable length, suitable for long-distance installation |
- Înlocuire & Cross Reference
4.1 Same Brand Direct Replacement
| Model original | Model de înlocuire | Replacement Description | Scenariul aplicației |
| VNY 4 NS/NT (481046) | VNYI 4 IS/NT | Upgraded insulated electrodes to avoid false triggering from liquid clinging | Viscous liquids and wall-adhering media (syrup, lubricating oil) |
| VNY 4 NS/NT (481046) | VNY 4 NS/CB | Changed to cable connection for heavy vibration environments | Level monitoring for vibrating equipment such as pump sets and compressors |
| VNY 4 NS/NT (481046) | VN 4 NS/CB | Cable type with PBTP housing and 1 1/2″ thread | General industrial environments, better cost performance |
4.2 Cross-Brand Equivalent Models
| Carlo Gavazzi | Schneider | Omron | Pepperl+Fuchs | Main Differences |
| VNY 4 NS/NT (481046) | XPSAK3711 | D4CC-4000 | FTL20-0020 | Carlo Gavazzi adopts superior AISI316 material with IP67 protection |
| Schneider higher integration; Omron more cost-competitive | ||||
| Field-cuttable electrode length for better adaptability | ||||
| Pepperl+Fuchs suitable for explosion-proof areas; Carlo Gavazzi for general industry |
- Application Industries & Typical Cases
Recommended Applications
- Process Industry: Tank level monitoring in chemical, petrochemical and pharmaceutical industries to prevent overflow and dry running
- Mâncare & Băutură: Raw material and finished tank level control for beer, beverage and dairy production lines
- Tratarea apei: Level monitoring for sedimentation tanks and reaction tanks in waterworks and wastewater plants
- Energy Sector: Level protection for cooling and lubrication systems in power plants and substations
- Mechanical Manufacturing: Oil level monitoring for hydraulic and lubrication systems to avoid equipment damage
- Marine Industry: Level measurement for ship ballast tanks, fuel tanks and fresh water tanks
Cazuri tipice de aplicare
- Chemical Plant Acid & Alkali Tank Level Control System
Application Goal: Monitor high/low levels of three 100m³ acid and alkali tanks to prevent overflow and pump dry running
Avantajele de bază: AISI316 corrosion-resistant electrodes; IP67 suitable for outdoor installation; 4-electrode enables multi-point level monitoring
System Configuration: VNY 4 NS/NT (481046) × 3 + ELA amplifier relay + PLC control system + HMI touch screen
Operation Effect: Level control accuracy ±1cm, false alarm rate reduced by 95%, maintenance cost cut by 60%
- Automobile Factory Hydraulic Station Oil Level Monitoring System
Application Goal: Monitor oil levels of 5 hydraulic stations to ensure stable operation and prevent oil shortage failure
Avantajele de bază: Vibration-resistant screw terminal design; oil-resistant PBTP housing; field-cuttable electrodes adaptable to various tank heights
System Configuration: VNY 4 NS/NT (481046) × 5 + S196 amplifier + indicator light + buzzer
Operation Effect: Equipment failure rate reduced by 40%, maintenance cycle doubled
Not Recommended Applications
Non-conductive liquids: Such as pure oil, alcohol, acetone; not detectable by conductive sensors
High temperature >90°C: Adopt VPP series (up to 100°C) or high-temperature versions
Working pressure >10 bar: Special high-pressure level sensor required
Strong corrosive media: Concentrated hydrochloric acid, concentrated sulfuric acid; use VPP series with PVDF electrodes or anti-corrosion coated models
- Instalare & Ghid de cablare
Cerințe de instalare
- Poziția de montare: Install on tank top or side, away from inlet ports and agitators; ensure vertical electrode immersion
- Electrode Cutting: Cut electrode length on-site according to actual liquid level; deburr the end after cutting for accuracy
- Sealing: Use suitable gaskets (PTFE recommended) for leak-tight installation to maintain IP67 protection
- Earthing Requirement: Conductive tank body can serve as common electrode; non-conductive tanks require separate common electrode grounding
- Spacing Requirement: Keep ≥50mm between electrodes and between electrodes and tank wall to avoid signal interference
Core Terminal Definition
| Terminal No. | Funcţie | Tip | Observații |
| E1/E2/E3/E4 | Electrode 1–4 | Signal Input | Correspond to four level detection points; freely assign high/medium/low functions |
| COM | Terminal comun | Signal Reference | Connect to tank wall or separate common electrode to complete circuit |
| +V/-V | Alimentare electrică | 24VDC | Requires matching amplifier relay; sensor itself needs no independent power supply |
| NO/NC/COM | Ieșire releu | Switch Contact | Provided by amplifier relay for valve control or alarm output |
Puncte cheie de punere în funcțiune
- Electrode Setting: Define corresponding level heights for each electrode (de ex. E1=Low, E2=Medium, E3=High, E4=Ultra-high)
- Sensitivity Adjustment: Adjust amplifier relay sensitivity to avoid false triggering caused by foam or clinging liquid
- Test de funcționare: Simulate level changes to verify accurate switching action and response time
- Insulation Check: For non-insulated type, ensure no short circuit between electrodes and tank wall; check insulation integrity for insulated type
- Environmental Adaptation Test: Verify long-term stability within rated temperature and pressure range
- Selection Rules & Quick Reference
Ghid de selecție
- Liquid Type: Choose VNY series for conductive liquids; use capacitive or ultrasonic sensors for non-conductive liquids
- Electrode Quantity: 1=single point, 2=high/low, 3=high/medium/low, 4=four-point full control
- Electrode Insulation: NS for normal liquids; IS insulated type for viscous wall-adhering media
- Tip conexiune: NT screw terminal for vibration environments; CB cable type for long-distance installation
- Mounting Thread: 1 1/2″ for large tanks, 1″ for medium, 1/2″ for small containers
- Temperatură & Pressure: VNY for 0–90°C / 10 bar; VPP for higher temperature; special models for higher pressure
- Air Freight Compliance & Certificari
Air Freight Compliance: No lithium battery / supercapacitor. Pure mechanical and metallic structure, compliant with IATA DGR Class 9, shippable as standard general cargo.
Certificari:
– CE: Conform IEC 529 ingress protection standard
– RoHS: EU RoHS compliant, free of hazardous heavy metals
– Material Certification: AISI316 stainless steel electrodes meet food-contact grade requirements for food & beverage industry
Environmental Compliance: Compliant with REACH regulations for global market access
- de cumpărare & Logistics Information
| Purchase Item | Detalii |
| MOQ | 1 unitate |
| Lead Time | Standard 5–7 days; Express 2–3 days |
| Ambalare | Individual carton with installation manual, sealing gasket and mounting nut |
| garanție | 12 months from commissioning acceptance |
| Recommended Spares | Same model sensor, electrode extension joint (VD1), mounting nut (VM15) |
| Accesorii potrivite | Carlo Gavazzi ELA/ELC/ELD amplifier relay, PLC, HMI touch screen |
Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare