Izolator Schneider Electric Compact INS630-3 poli

This product is a non-automatic load break isolator from Schneider Electric’s Interpact INS series, with the official order code 31114.

It is designed for power isolation and maintenance safety in low-voltage distribution systems.

It is 3-pole, rated current 630A, rated voltage 690VAC, without short-circuit or overload protection, and is used only for isolation purposes.

  1. Defalcarea modelului
Partea modeluluiSensKey Description
CompactProduct platformSchneider compact distribution platform, suitable for limited panel space
INSCod de serieInterpact INS series, non-automatic load break isolator, isolation only, no protection
630Cadru / curent nominalFrame size 630A, operational current 630A (AC-22A / AC-23A)
3 PolNumărul de poli3P (three-phase three-wire), no neutral pole, not suitable for neutral isolation in TN‑S / sisteme TT
31114Official order codeUnique code for standard version (black rotary handle, fixed mounting)
  1. Specificații tehnice cheie (Official Standard)
ArticolCaietul de sarciniStandard aplicabil
Tip de produsNon-automatic load break isolatorIEC 60947-3, ÎN 60947-3
Tensiune nominalăAC 690V, Ui 750VSuitable for 380/415/480V industrial systems
Curent nominal630O (AC-22A / AC-23A)Continuous operation ≤ 630A, recommended duty ≤ 80% (≤ 504A)
Curent de scurtă durată11.5kA/3s, 20kA/1s, 4kA/30sWithstands short-circuit current only, no breaking capacity
Impulse withstand voltageUimp 8kVLightning and overvoltage protection
OperațiuneaManual rotary handle (black)Motor operation available (separate order)
MontareTip fixFaţă / rear connection, 35mm DIN rail or panel mount
Ingress protectionIP20 body, IP55 with handleIndoor panels or outdoor enclosures
Rezistenta mecanica10,000 operațiuniExceeds standard industrial requirements
  1. Series Model List (630Un cadru)
Model (Cod de comandă)PoloniiTipAplicație
INS630 3P (31114)3PStandard isolatorIncoming, bus-coupler, equipment isolation (3-phase 3-wire)
INS630 4P (31115)4PStandard isolatorIsolation with neutral (3-phase 4-wire)
INS630 3P Changeover (31154)3PManual changeover switchMains / generator manual switching
INS630 4P Changeover (31155)4PManual changeover switch3-phase 4-wire dual power switching

Extended Current Ratings

Actual3P Code4P CodeCaracteristici de rupere
400O3111231113Same as INS630, current only
500O3111631117
630O3111431115This model
  1. Recommended Equivalent Models from Other Brands
MarcaSerieEquivalent ModelMatching ParametersNote
LS ElectricMeta-MEC ISIS630N-3P3P, 630O, 690V, isolatorEconomic version
ABBOTOT630E033P, 630O, 690V, isolatorVisible break
Siemens3KD3KD4630-0NE103P, 630O, 690V, isolatorMotor operation compatible
EatonNZMNZM3-XT6303P, 630O, 690V, isolatorEnhanced interlocking
Comutator ChangshuCM1GCM1G-630/33003P, 630O, 690V, isolatorDomestic high cost‑performance
  1. Aplicații tipice (Isolation Only, No Protection)
  2. Uzini industriale
AplicațieMotivRecomandare
Production line main isolation630A suitable for ≤315kW three-phase loadsUsed in series with NSX630N circuit breaker
Large motor circuit isolationMotors above 200kW (fani, pompe, compresoare)Complete protection with contactor & releu
Panel bus-coupler isolationDual power supply systemsMechanical interlock recommended
  1. Comercial & Public Buildings

Office / shopping mall incomer isolation with EZD630 breakers

Secondary distribution isolation in hospitals and schools

Infrastructure partial isolation (metro, airport utilities)

  1. Aplicații speciale

Generator outlet isolation ≤500kVA

Capacitor bank isolation ≤300kvar

Construction site temporary power isolation

  1. Selecţie & Operation Guidelines
  2. Selection Rules
FactorSelectie corectaRisk of Wrong Selection
FuncţieIsolation only; must be used with a circuit breakerNo protection, equipment burnout
Polonii3P for IT systems; 4P for TN‑S / TTRisk of electric shock without neutral isolation
ActualTotal load ≤ 504A (80% duty)Overheating, reduced life
ScurtcircuitSystem Isc ≤ 11.5kA/3sContact welding, failure to open
  1. Safety Rules
  2. Do NOT break under load — operate only at no-load or light load
  3. Use interlocks with upstream breakers
  4. Indoor dry environment (-25°C ~ +70°C); outdoor needs IP55 enclosure
  5. Accesorii: contacte auxiliare, motor operation, padlock attachment available
  6. Key Difference from Circuit Breaker
ArticolCompact INS630 3PCompact NSX630N 3P
TipLoad break isolatorMolded case circuit breaker (MCCB)
FuncţieIsolation onlySupraîncărcare + protectie la scurtcircuit
Capacitate de rupereNici unul, withstand onlyIcu = 50kA @ 415V
UsageManual isolation for maintenanceAutomatic protection during operation
ConexiuneInstalled after breakerMain protection device

Schneider Compact INS630-3P (order code 31114) is a dedicated isolation device for safe maintenance in LV distribution systems.

It must be used with a circuit breaker.

If you require both protection and isolation, use NSX630N.

For economic alternatives, consider LS IS630N or Changshu CM1G.