счастливая случайность 572-2 High Temperature Infrared Thermometer - Контактор,автоматический выключатель,датчик,Кодер,ПЛК,Конвертер

Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

 счастливая случайность 572-2 High Temperature Infrared Thermometer - Контактор,автоматический выключатель,датчик,Кодер,ПЛК,Конвертер

электрический/

счастливая случайность 572-2 High Temperature Infrared Thermometer

Позиционирование продукта: Industrial handheld infrared thermometer combining infrared and K-type thermocouple. Designed for long-distance high-temperature measurement, widely used in power, металлургия, cement and petrochemical industries. Key Specifications Infrared Temperature Range: -30 ℃ ~ 900 ℃ Distance-to-Spot Ratio (Д:С): 60:1 (90% энергия), minimum spot diameter φ19 mm, dual-laser targeting Infrared Accuracy (at 23℃ ambient): ≥0℃: ±1℃ ...

  • Подробная информация о продукте

Позиционирование продукта: Industrial handheld infrared thermometer combining infrared and K-type thermocouple. Designed for long-distance high-temperature measurement, widely used in power, металлургия, cement and petrochemical industries.

Ключевые характеристики

Infrared Temperature Range: -30 ℃ ~ 900 ℃

Distance-to-Spot Ratio (Д:С): 60:1 (90% энергия), minimum spot diameter φ19 mm, dual-laser targeting

Infrared Accuracy (at 23℃ ambient):

≥0℃: ±1℃ or ±1% of reading, whichever is greater

-10 ~ 0℃: ±2℃

<-10℃: ±3℃

K-type thermocouple input (contact temperature measurement): -270 ℃ ~ 1372 ℃

Emissivity: 0.10 ~ 1.00 регулируемый (0.01 step), built-in material emissivity lookup table

Время ответа: <500РС (95%)

Spectral Band: 8~14 μm

Хранение данных: До 99 записи, USB export supported

Отображать: MAX/MIN/AVG/DIF, high/low temperature audible & визуальная сигнализация, adjustable backlight

Источник питания: 2×AA batteries; Вес нетто: 322г

Основные характеристики

  1. Dual-Laser Targeting: Offset dual lasers mark the measurement area for precise targeting of small objects from long distances
  2. Dual Measurement Mode: Non-contact infrared + K-type thermocouple contact measurement, balancing operational safety and accuracy verification
  3. Industrial Robustness: Ergonomic anti-slip housing, intuitive menu, многоязычная поддержка
  4. Alarm Function: Audible and visual alert on temperature threshold violation, suitable for inspection and predictive maintenance of equipment

Типичные применения

Power industry: Switchgear, шины, трансформаторы, cable joints temperature inspection

Металлургия / Heat treatment: Furnace body, rolls, casting surface temperature

Цемент, стекло, нефтехимический: Kiln, pipeline, reactor surface temperature measurement

Machinery industry: Мотор, bearing and high-temperature equipment inspection

Standard Package Contents

счастливая случайность 572-2 Основной блок

K-type bead thermocouple probe

USB-кабель

2 AA batteries

User manual and certificate of conformity

Comparison with Related Models

счастливая случайность 572-2: 60:1 соотношение, max infrared temp 900℃, with K-type thermocouple and data storage

счастливая случайность 568: 50:1 соотношение, max infrared temp 800℃

счастливая случайность 62 MAX+: 12:1 соотношение, max temp 650℃, entry-level industrial model

Выбор & Примечания по эксплуатации

  1. Д:S=60:1: The spot size increases with measurement distance; shorten distance when measuring small targets
  2. Polished metallic surfaces have low emissivity and may cause large measurement error. High-temperature tape is recommended to raise emissivity
  3. Infrared measures surface temperature only; K-type thermocouple is used for contact temperature comparison
  4. Not suitable for measurement through glass or transparent plastics (infrared radiation will be blocked)

счастливая случайность 572-2 Контрольный список устранения неполадок

Recommended troubleshooting sequence: Power supply → Lens / Optical path → Parameter setting → Ambient condition → Hardware / Error code; Do NOT disassemble the unit. Disassembly of internal laser and sensor will void calibration and warranty.

  1. Power Supply Faults
СимптомПервопричинаСредство
Blank screen, no response when trigger is pulledSleep mode / Dead battery / Обратная полярность1. Pull trigger to wake up; 2. Replace with new AA alkaline batteries, verify polarity; 3. Inspect battery contacts for oxidation or electrolyte corrosion
Low battery icon displayed, unstable readingsInsufficient battery voltageReplace batteries immediately; Accuracy is unreliable under low power, discontinue inspection
Emissivity, time and stored data lost after battery replacementBattery removal exceeds 1 мин, mainboard power resetReplace battery promptly upon low power alert; Complete battery swap within 1 минута; Reconfigure parameters afterwards
  1. Отображать & Error Codes
СимптомПервопричинаСредство
shown on screenTarget temperature out of range (<-30℃ or>900℃)Confirm target temperature is within measuring range; Infrared max 900℃, K-type thermocouple max 1372℃
EEPROMErr / CalAreaErr / ProbCalErDamaged internal storage / calibration dataNo on-site repair possible. Stop operation and send to Fluke authorized service center
Alarm light flashes with buzzer soundВысокий / low temperature alarm triggeredEnter menu to check threshold, modify or disable alarm as required

III. Laser Targeting Faults

СимптомПервопричинаСредство
Valid infrared reading but dual laser does not turn onLow battery; Ambient temp>40℃; Laser disabled in menu1. Replace battery; 2. Move to location with ambient temp ≤40℃; 3. Enable laser in menu
Blurred or offset laser spotDirty or scratched lensClean lens; Replace lens assembly if scratched
  1. Inaccurate / Drifting Readings (Most Common Fault)

Distinguish first: Infrared reading error VS K-type thermocouple probe error

Inaccurate Infrared Readings

  1. Wrong emissivity setting: Polished metal has low emissivity leading to high reading; Non-metal has high emissivity. Adjust emissivity from 0.10~1.00; Apply high-temperature tape for shiny metal (emissivity≈0.95)
  2. Field-of-view spot issue: Д:S=60:1. Too long distance results in spot larger than workpiece and captures surrounding hot/cold objects. Shorten distance and ensure full spot coverage on target surface
  3. Загрязнение линзы: Пыль, масло, moisture attenuate infrared signal

✅ Cleaning procedure: Blow with compressed air → Brush gently with camel hair brush → Wipe with cotton swab moistened with pure water; Do NOT use alcohol, acetone or other solvents, which will damage infrared lens

  1. Ambient interference: Hot air stream, steam, smoke, стекло / transparent plastic blocking optical path; сильные электромагнитные помехи (welding machine, induction heating); water film or oxide scale on target surface
  2. Thermal shock: Sensor unstable when moved from drastically different temperature environment. Let instrument stabilize ≥30 minutes on site before measurement
  3. Reflected heat from surrounding hot sources causes falsely high reading: Adjust measurement angle to avoid hot background reflection

No Reading / Abnormal Reading on K-type Thermocouple Channel

  1. Loose or oxidized probe connector; сломанный провод

✅ Remedy: Re-seat connector; Cross-test with 80PK series K-type probe to identify fault on probe or instrument jack

  1. Wrong thermocouple type selected: Unit only accepts K-type. S/T/J type probes cannot read correctly
  2. Cold junction compensation anomaly: Large temperature difference at probe terminal
  3. USB Communication & Data Export Faults
СимптомПервопричинаСредство
PC fails to recognize instrument and export recordsInstrument not powered on; FlukeView Forms software not running; Damaged USB cable1. Hold trigger to keep unit powered; 2. Launch FlukeView Forms software; 3. Replace USB cable for test; 4. Check PC USB port
Stored data lostBattery depleted for long time; Battery replacement timeoutExport records regularly; Replace battery at low power prompt
  1. Механический & Appearance Faults
  2. Sticky trigger: Dust accumulated in trigger gap, clean with dry brush, Do NOT apply lubricant
  3. Треснувший корпус: Damage from drop impact. Crack does not affect temperature reading but reduces ingress protection, keep away from moisture
  4. Lens scratch: Scratch introduces measurement error, return to factory for lens replacement and recalibration

VII. Решение по ошибке & Service Standard (When to Stop Using)

✅ On-site repairable: Battery replacement, lens cleaning, parameter reset, probe cross-verification

❌ Must send to official service, no disassembly allowed:

  1. EEPROM or calibration related error codes
  2. Cracked lens, internal water condensation
  3. Persistent reading deviation after drop impact, cannot be corrected by lens / emissivity adjustment
  4. Battery leakage corroding mainboard contacts

VIII. Quick On-Site Self-Check Procedure

  1. Install new batteries and stabilize for 30 min under ambient condition
  2. Clean lens, restore factory menu setting, set emissivity to 0.95
  3. Measure warm water (приблизительно. 80~90℃) in infrared mode, connect K-type thermocouple for contact comparison; Deviation shall stay within specified accuracy
  4. Verify laser, high/low alarm, backlight and trigger hold function
  5. Test USB connection and data read/write

счастливая случайность 570 Ряд (572 Family) Список моделей

Consists of Legacy 570 ряд (Снято с производства) and Currently available 572-2. счастливая случайность 570 series is industrial high-precision long-distance infrared thermometer with K-type thermocouple input.

  1. Наследие 570 Ряд (Снято с производства, available in spare / second-hand market)
МодельКлючевая конфигурацияКлючевые различия
счастливая случайность 572 (наследие, no -2 суффикс)-30~900℃, Д:S=60:1, 3-point laser targeting, K-type thermocouple input, RS232 interfaceOld version with serial port, no USB, прекращено
счастливая случайность 574-30~900℃, Д:S=60:1, 3-point laser, RS232, регистрация данных, optional close-focus 50:1 маленькое пятноEnhanced data logging vs 572; 574-NI: version without infrared calibration certificate
счастливая случайность 576-30~900℃, Д:S=60:1, built-in digital camera for image archive, USB, 3-point laserTop-tier model with image capture, long discontinued
  1. Current Active Model: счастливая случайность 572-2 (Replaces legacy 572)

Your target model, current main production unit

Измерение температуры: Infrared -30 ~ 900℃; Термопара типа К -270 ~ 1372℃

Д:S=60:1, dual-laser targeting; 99 local storage records, USB-экспорт

Dual mode (инфракрасный + contact thermocouple), слышимый & visual high/low temperature alarm

Industries: Власть, металлургия, нефтехимический, cement high-temperature inspection

III. Related Dual-Mode Infrared Thermometers (Commonly compared with 572-2 for selection)

Not part of 570 ряд, but Fluke handheld infrared + K-type thermocouple models frequently referenced in project selection

|Модель|Infrared Range|Д:С|Функции|

|—|—|—|—|

|счастливая случайность 568|-30~800℃|50:1|Dual mode, lower spec alternative to 572-2 with lower max temperature|

|счастливая случайность 568 EX|-30~800℃|50:1|Intrinsically safe explosion-proof version for hazardous oil & gas area|

|счастливая случайность 561|-40~550℃|12:1|HVAC dedicated entry-level dual mode unit|

  1. Infrared-only Models (No thermocouple, reference for category comparison, not in 570 ряд)

счастливая случайность 62 MAX / 62 MAX+: -30~650℃, Д:S=12:1, IP54, 3m drop resistance

счастливая случайность 64 MAX: -30~600℃, Д:S=20:1

  1. Model Version Remarks
  2. 572-2 has no sub-models, only standard main unit. Variants come from accessory kits: Optional carrying case, extended thermocouple probe, tripod
  3. Наследие 572/574/576 permanently discontinued. Only surplus stock, refurbished or second-hand units available; calibration and spare parts are difficult to source. Выбирать 572-2 for new projects
  4. Key distinction: Legacy models use 3-point laser; new 572-2 uses dual laser targeting system