ABB F204B63-2CSF204592R1630 - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Leistungsschalter/

ABB F204B63-2CSF204592R1630

This is a ABB F200 Series 4-pole Type B Residual Current Circuit Breaker (FI-Schutzschalter) with a rated current of 63A and a rated residual operating current of 30mA. This model is obsolete. The original manufacturer replacement part number is 2CSF204568R1630 (F204B-63/0.03-4TE). It is designed for industrial applications equipped with frequency converters, UPS and other devices, ...

  • Produktdetails

Das ist ein ABB F200 Series 4-pole Type B Fehlerstromschutzschalter (FI-Schutzschalter) with a rated current of 63A and a rated residual operating current of 30mA. This model is obsolete. The original manufacturer replacement part number is 2CSF204568R1630 (F204B-63/0.03-4TE). It is designed for industrial applications equipped with frequency converters, UPS and other devices, and provides protection against smooth DC leakage current.

  1. Erklärung des Modellcodes
ModellsegmentDefinitionDetaillierte Beschreibung
F204BasismodellF200 Series, 4-pole residual current circuit breaker
BResidual Current TypeTyp B, capable of detecting AC, pulsating DC and smooth DC residual current (0-1000Hz)
63Nennbetriebsstrom63A, continuous current rating
0.03Nenn-Restbetriebsstrom0.03A = 30mA, high-sensitivity protection against direct human contact
2CSF204592R1630BestellcodeUnique official ABB identification code for purchasing and traceability
4DERMontageartStandard DIN rail mounting with 4-pole terminals (marked on partial versions)
  1. Wichtigste technische Spezifikationen
KategorieTechnische DatenBemerkungen
Grundlegende Eigenschaften
ProdukttypFehlerstromschutzschalter (FI-Schutzschalter)No overload or short-circuit protection; must be used with MCB
SerieSystem pro M compact® F200ABB modular power distribution product line
Polen4P (L1, L2, L3, N)Protection for 3-phase 4-wire systems
Nennspannung400V und (50/60Hz)Betriebsspannungsbereich: 380-415V
Nennstrom (In)63ACompliant with IEC/EN 61008-1
Nenn-Restbetriebsstrom (IΔn)30mAInstantaneous type (no time delay)
Residual Current TypeTyp BComprehensive protection against AC, pulsating DC and smooth DC leakage current
Leistungsparameter
Bruchkapazität (IΔm)3DieBreaking capacity under rated conditions
Betriebszeit≤0.04s @ IΔn=30mAMeets requirements for rapid personal safety protection
Rated Residual Non-operating Current (IΔNr)15mANo tripping below this value to avoid nuisance tripping
TesttasteEingebautFor regular functional testing
Physikalische Eigenschaften
Abmessungen (B × H × T)70mm × 85mm × 60mmStandardmäßiger modularer Aufbau, occupies 4 module units
Montage35mm DIN-SchieneKonform mit EN 50022
TerminaltypBi-directional cylindrical terminalsFacilitates cable connection and enhances safety
GewichtCa. 360GWeight per unit
Umfeld & Zertifizierungen
Betriebstemperatur-25°C ~ +55°CPerformance may be affected beyond this range
Lagertemperatur-40°C ~ +85°C
Luftfeuchtigkeit5% ~ 95% (nicht kondensierend)
Schutz vor EindringenIP20Fingersicher, not suitable for outdoor use
ZertifizierungenIEC/EN 61008-1, IEC/EN 61008-2-1CE-zertifiziert, complies with international safety standards
Lebenszyklusstatus
StatusVeraltetStock still available via some distributors
Discontinued DateJun-24Official record
  1. Vollständige Modellliste (F204 Type B)
ModellBestellcodeNennstromRated Residual CurrentMerkmale
F204 B-25/0.032CSF204592R125025A30mA4-pole Type B, basic model
F204 B-40/0.032CSF204592R140040A30mA4-pole Type B, medium current
F204 B-63/0.032CSF204592R163063A30mA4-pole Type B, standard industrial model
F204 B-63/0.12CSF204592R263063A100mA4-pole Type B, higher sensitivity
F204 B-63/0.32CSF204592R363063A300mA4-pole Type B, Geräteschutz
F204 B-63/0.52CSF204592R463063A500mA4-pole Type B, system protection
F204 B-80/0.032CSF204592R180080A30mA4-pole Type B, hoher Strom
F204 B-100/0.032CSF204592R1100100A30mA4-pole Type B, extra high current
F204 B-125/0.032CSF204592R1125125A30mA4-pole Type B, maximum current
F204 B-63/0.03-4TE2CSF204568R163063A30mAReplacement model, 4-pole Type B, standard terminals
  1. Ersatzlösungen & Markenübergreifende Äquivalente

4.1 Original Manufacturer Replacements

OriginalmodellErsatzmodellGrund für den AustauschKompatibilität
F204 B-63/0.03 (2CSF204592R1630)F204 B-63/0.03-4TE (2CSF204568R1630)Product upgrade with optimized terminal designVollständig kompatibel, Direkter Ersatz
DDA204 B-63/0.03 AP-R (2CSB204592R1630)FI-Block series, integrated designIdentical mounting dimensions and functions

4.2 Cross-Brand Compatible Replacements

MarkeModellTechnical Matching RateBemerkungen
SchneideriC60H RCCB 4P 63A 30mA Type B95%Dimensionally compatible, equivalent performance
Siemens5SU1356-6KK6390%Slight difference in tripping characteristics
Legrand4102 63 03 B90%Different wiring terminals
Chint (China)NXBLE-400/4P 63A 30mA Type B85%Cost-effective with complete certifications
  1. Anwendungsumgebungen & Typische Fälle

5.1 Empfohlene Anwendungen

Industrielle Automatisierungssysteme: Frequency converters, Servoantriebe, SPS-Schränke; protects against smooth DC leakage current.

Medizinische Ausrüstung: Operationssäle, ICU devices; provides top-level leakage protection.

Rechenzentren: USV-Systeme, server cabinets; prevents nuisance tripping caused by power fluctuation.

Erneuerbare Energie: PV-Wechselrichter, Energiespeichersysteme; protects DC side leakage.

Gewerbebauten: Kitchen equipment, central air conditioning, elevator control systems; protection for 3-phase loads.

5.2 Nicht empfohlene Anwendungen

Pure residential single-phase loads: Type B is overqualified; Type AC is sufficient.

Outdoor humid environments: IP20 rating is inadequate; additional enclosure protection required.

Explosionsgefährdete Bereiche: Explosion-proof products must be used.

Applications requiring overload/short-circuit protection: This unit only provides leakage protection and shall be used together with MCB.

5.3 Typische Anwendungsfälle

Fall 1: Automotive Manufacturing Workshop

Ausrüstung: Robotic welding systems, converter-driven production lines

Ausgabe: Frequent nuisance tripping of conventional Type AC RCCBs affected production.

Lösung: Install F204 B-63/0.03 to protect against smooth DC leakage generated by converters.

Ergebnis: Nuisance tripping rate reduced by 90%, production efficiency improved by 15%.

Fall 2: Hospital Operating Room

Ausrüstung: Anesthesia machines, Patientenmonitore, surgical lights

Requirements: Höchste Sicherheitsstufe, zero nuisance tripping and fast response.

Lösung: Adopt F204 B-63/0.03 combined with S204-B63 MCB.

Ergebnis: Complies with medical equipment safety standards and ensures operational safety.

  1. Fehlerbehebung & Maintenance Manual

6.1 Häufige Fehler & Lösungen

FehlerphänomenMögliche UrsachenSchritte zur Fehlerbehebung
Häufiges Stolpern1. Actual circuit leakage1. Test circuit insulation with megohmmeter after power off
2. DC leakage from loads2. Verify if loads require Type B RCCB
3. Product aging3. Check production date; replace if service life exceeds 10 Jahre
4. Lose Kabelklemmen4. Retighten wiring terminals
Failure to trip1. Beschädigter Testknopf1. Replace test button assembly
2. Internal trip mechanism fault2. Send for repair or replace the unit
3. Falsche Verkabelung (neutral wire disconnected)3. Check wiring and ensure neutral wire is properly connected
Cannot be reset1. Mechanical lock failure1. Manually reset after power off; replace if failed
2. Persistent leakage2. Eliminate leakage fault before resetting
3. Zu hohe Umgebungstemperatur3. Verbessern Sie die Belüftung und senken Sie die Umgebungstemperatur
Indicator light off1. Damaged indicator lamp1. Replace indicator lamp
2. Internal circuit fault2. Send for repair or replace the unit

6.2 Maintenance Procedures

  1. Routine Inspection (Monatlich)

Visually inspect for damage or discoloration.

Press test button to confirm normal tripping and reset.

Check terminals for looseness and overheating marks.

  1. Regelmäßige Wartung (Jährlich)

Clean unit surface with dry soft cloth after power cut.

Check firmness of DIN rail mounting.

Measure insulation resistance (≥1MΩ).

Record test results.

  1. Austauschzyklus

Normal operating conditions: 10 Jahre

Raue Umgebungen (hohe Temperatur / hohe Luftfeuchtigkeit): 5~7 years

Frequent tripping conditions: 3~5 years

6.3 Quick Diagnosis Tips

Type B RCCB handles DC leakage well.

Check wiring first for frequent tripping; load type matters most.

Replace unit immediately if test button malfunctions.

Power off and clear faults before resetting.

Replace after 10 years for reliable safety.

  1. Auswahlrichtlinien
  2. Residual Current Type Selection: Choose Type B for systems with converters, UPS or medical devices; Type AC for general lighting and sockets; Type A for pulsating DC loads.
  3. Auswahl des Nennstroms: Nennstrom ≥ 1.2 times total load current. 63A is suitable for most industrial control cabinets.
  4. Residual Current Rating Selection: 30mA für den Personenschutz; 100~300mA for equipment protection; 500mA~1A for system protection.
  5. Polauswahl: 2P for single-phase systems; 3P for 3-phase 3-wire systems; 4P (mit Neutralleiter) for 3-phase 4-wire systems.
  6. Replacement Principle: Prioritize upgraded models from the same series for obsolete products to guarantee identical dimensions and performance.