Allen‑Bradley 20G11NC011AA0NNNNN AC Drive

PowerFlex 755 Air-Cooled AC Variable Frequency Drive (VFD) Ciclo vital: Obsoleto (Last order date: 2024‑06‑30). Direct OEM replacement part number: 20G11NC011JA0NNNNN Catalog Number Breakdown (20G Series Coding Rule) 20GRAMO 1 1 N C 011 A 0 NNNNN Segment Code Description 1~3 20G PowerFlex 755 air-cooled AC drive series 4 1 Embedded EtherNet/IP, standard protection, forced air ...

  • Detalles del producto

PowerFlex 755 Air-Cooled AC Unidad de frecuencia variable (VFD)

Ciclo vital: Obsoleto (Last order date: 2024‑06‑30). Direct OEM replacement part number: 20G11NC011JA0NNNNN

  1. Catalog Number Breakdown (20G Series Coding Rule)

20GRAMO 1 1 N C 011 A 0 NNNNN

SegmentoCódigoDescripción
1~320GRAMOPowerFlex 755 air-cooled AC drive series
41Embedded EtherNet/IP, standard protection, refrigeración por aire forzado
51AC input with DC bus terminals
6norteIP20 / IP00, Open Frame (NEMA Open Type)
7do400V trifásico (380~480VAC)
8~1011Rated output current 11.5A
11AIntegrated Dynamic Braking Transistor (DB Transistor)
120No HIM keypad (blank)
13~17NNNNNNo additional option modules
  1. Especificaciones eléctricas clave

Corriente nominal: 11.5A

Clase de voltaje: 3-phase 400V AC

Clasificación de potencia:

DAKOTA DEL NORTE (Servicio normal): 5.5kilovatios

alta definición (Servicio pesado): 4kilovatios

Tamaño del marco: Marco 2

Enfriamiento: Refrigeración por aire forzado

Comunicación: Embedded EtherNet/IP (DLR ring support)

Dynamic Braking: Built-in DB transistor, Se requiere resistencia de frenado externa

Clasificación del gabinete: IP20 (solo para montaje en gabinete)

Aporte: AC main circuit with brought-out DC bus terminals, suitable for common DC bus applications

  1. Aplicaciones típicas

Transportadores, fans, zapatillas, extruders and general-purpose industrial motor speed control; supports multi-axis EtherNet/IP motion control and can share the same network with Kinetix servo drives.

  1. Hardware & Notas de mantenimiento
  2. Obsolete notice: After discontinuation of AA0 suffix legacy units, JA0 is the drop-in compatible replacement. Dimensiones de montaje, I/O and program parameters are fully compatible for direct replacement.
  3. Accesorios opcionales: HIM keypad (20‑750‑HIM), input EMC filter, dynamic braking resistor, Desconexión de par segura (STO) módulo.
  4. Puntos de falla comunes: Fan aging, DC bus capacitor degradation, ESD damage on EtherNet/IP port; for spare part replacement, prioritize OEM JA0 version.
  5. Domestic Alternative Reference (Same rating 400V /11.5A VFD)

Innovación MD880, V&T AC800, Xinje DS500. Hardware replacement is feasible, but communication program, parameter groups and terminal definitions require re-commissioning. Cannot directly inherit the original Rockwell EtherNet/IP motion link.

  1. Referencia del código HS

8504409990 (Otros convertidores estáticos, general classification for VFDs. Final customs classification subject to local customs authority.)

PowerFlex755 (20G11NC011AA0NNNNN) Power-On Commissioning Parameter List

Aplicable: 400V, ND 5.5kW / HD 4kW, embedded EtherNet/IP, integrated braking transistor. Estructura: Pre-power-on inspection → Factory reset → Motor nameplate data → Control mode → Start / Speed reference source → Accel/Decel & límites & protection → Autotune → EtherNet/IP communication → Dynamic braking & fault strategy → Monitoring parameters

Nota: Parameter numbers refer to Port0 (drive native parameters). Actual values from motor nameplate must be entered on site. Italic values below are examples.

  1. Pre-Power-On Hardware Check (Not parameters, mandatory before commissioning)
  2. Circuito principal: 3-phase input R/S/T, output U/V/W, DC bus, braking resistor wiring and earthing.
  3. circuito de control: 24V control supply, STO safety terminals must be shorted (short required if no STO module, otherwise safety fault alarm).
  4. Motor decoupling recommended: Disconnect mechanical load before initial autotune.
  5. Rating verification: Drive rated 11.5A, match motor rated current.
  6. Factory Reset (Nuevo proyecto / After repair)
Parameter No.English NameChinese NameConfiguraciónObservaciones
5Reset To Default恢复出厂Opciones>Factory ResetTakes effect after power cycle; clears all custom parameters. Recommended for new commissioning.
  1. Motor Nameplate Parameters (Crítico, enter from nameplate)
Parameter No.English NameChinese NameExample ValueObservaciones
26Motor NP FLA电机额定电流10.5AMotor full load current from nameplate, shall not exceed drive 11.5A
27Motor NP Hertz电机额定频率50HzFrom nameplate
28Motor NP RPM电机额定转速1480RPMFrom nameplate
29Mtr NP Pwr Units电机功率单位0=kW /1=HP0=kilowatt
30Motor NP Power电机额定功率5.5kilovatiosFrom nameplate
31Motor NP Volts电机额定电压380VFrom nameplate
  1. Modo de control (TotalFORCE, for induction motors)
Parameter No.English NameChinese NameConfiguración recomendadaObservaciones
35Motor Cntl Mode电机控制模式2=Sensorless VectorPreferred for fans/pumps/conveyors;
use 3=Flux Vector for high precision torque control (encoder required)
  1. Command Source & Speed Reference Source (Select ONE: Control de terminales / EtherNet/IP Network Control)

Option A: EtherNet/IP Network Control (Built-in port standard on this unit, most common for projects)

Parameter No.English NameChinese NameConfiguraciónObservaciones
160Start Source启动命令源Port13 (Embedded EtherNet/IP)Start/stop command from Logix controller
161Speed Ref Source速度给定源Port13 (Embedded EtherNet/IP)Speed reference from network

Option B: Local Terminal Control (Commissioning test / Standalone test)

Parameter No.English NameChinese NameConfiguraciónObservaciones
160Start Source启动命令源Entrada digital (DI Terminal)Start/stop via DI terminals
161Speed Ref Source速度给定源Entrada analógica 0 (AI0)AI analog 0-10V /4-20mA reference
163DI Run数字输入 – 运行DI0DI0 = Run command
164DI Stop数字输入 – 停止DI1DI1 = Stop (normally closed for safety)
  1. Accel / Desacelerar & Limit Parameters
Parameter No.English NameChinese NameEjemploObservaciones
53Accel Time 1加速时间 15.0sExtend for heavy load; 8~20s for fans/pumps
54Tiempo de desaceleración 1减速时间 15.0sExtend for high inertia loads; can shorten if braking resistor fitted
55Max Freq最大频率50HzFrecuencia máxima de funcionamiento, do not exceed motor nameplate
56Min Freq最小频率0HzMinimum output frequency
57Speed CLIP Hi最高转速限幅1480RPMMatches motor rated speed
  1. Actual / Torque Protection Parameters
Parameter No.English NameChinese NameEjemploObservaciones
42Motor OL Current电机过载保护电流Motor nameplate FLAMotor thermal protection, use nameplate value
44Motor OL Select电机过载保护模式1=Class10Class10 for standard induction motors; Class20 for heavy duty
47Current Limit 1电流限幅11.5ADrive rated output current
49Torque Limit Pos正向转矩限幅150%Por defecto 150%; reduce for hoist applications
50Torque Limit Neg反向转矩限幅150%Reverse torque limit
  1. Motor Autotune (Crítico! Run after entering nameplate data)
Parameter No.English NameChinese NameOperaciónObservaciones
70Autotune电机自整定Static Tune 2Motor decoupled from load before autotune.
Static Tune: No motor rotation.
Rotational Tune: Motor spins, higher accuracy for commissioning

After successful autotune, parameter 70 automatically returns to Ready 0. If autotune fails, comprobar el cableado, nameplate entries and short-circuit to earth.

  1. Embedded EtherNet/IP Communication Parameters (Port13 Embedded Adapter)
Parameter No.English NameChinese NameConfiguraciónObservaciones
36BOOTPBOOTP 模式0=BOOTP DisabledFor static IP addressing
37IP AddressIP 地址192.168.1.10Site planned IP address
38Subnet Mask子网掩码255.255.255.0Match subnet segment
39Gateway网关192.168.1.1Gateway address
84Comm Flt Action通讯丢失动作0=Fault (Disparo por falla)Network break protection; optional 1=Coast, 2=Hold Speed
85Idle Flt Action控制器 Idle 动作0=FaultDrive action when PLC enters idle state

Hardware DIP switch: All DIPs set to 0 to allow software-configured IP. If DIPs are non-zero, IP is determined by hardware switches.

  1. Dynamic Braking Parameters (A suffix = integrated DB transistor on this model)
Parameter No.English NameChinese NameEjemploObservaciones
100DB Resistor Ohms制动电阻阻值Enter actual resistor valueMust match fitted external braking resistor
101DB Resistor Power制动电阻功率Actual power rating
102DB Level制动投入电压780VDefault for 400V class drives
103DB Overload制动电阻过载保护Set per resistor selection
  1. Auto Restart on Fault (Opcional, safety hazard risk)
Parameter No.English NameChinese NameConfiguraciónObservaciones
348Auto Rstrt Tries自动重启次数0=Disabled1~5 allowed for fans/conveyors; DO NOT enable for safety-critical machinery
349Auto Rstrt Delay重启延时5sDelay between each fault restart attempt
  1. Read-only Monitoring Parameters (For observation only, no write)
Parameter No.English NameChinese NameObjetivo
10Output Freq输出频率Actual output frequency
11DC Bus Volts直流母线电压Normal ~540~580V for 400V class
12Corriente de salida输出电流Actual motor current
13Motor Speed电机转速Estimated motor speed
220Digital In Sts数字输入状态Diagnose DI terminal status
  1. Standard Commissioning Procedure
  2. Power off → Factory reset parameters → Apply power
  3. Enter all motor nameplate parameters
  4. Configure control mode, command source and reference source
  5. Set accel/decel, limits and overload protection
  6. Run motor autotune with load decoupled, confirm autotune success
  7. Ethernet/IP: Set IP address, download PLC project, establish I/O connection
  8. No-load jog test, verify rotation direction, current and speed
  9. Loaded trial run, fine-tune accel/decel and torque limits
  10. Save parameters to drive (parameter backup), export via Studio5000
  11. Record and archive full parameter set
  12. Common Commissioning Pitfalls
  13. STO safety terminals: 20G11NC011AA0NNNNN has no STO module; STO jumpers on control board must be shorted, otherwise safety fault on power-up.
  14. Autotune fault: Check for open 3-phase motor wiring, nameplate data entry and earth short circuit.
  15. Replacement 20G11NC011AA0NNNNN → 20G11NC011JA0NNNNN: Parameters can be uploaded/downloaded directly, nearly fully compatible; only verify firmware version.

4. High inertia loads: Extend deceleration time or select higher rated braking resistor

Anterior: