Allen‑Bradley 440R‑D23171 Safety Relay

Allen‑Bradley Guardmaster MSR125HP (440R‑D23171) Two-Hand Control Safety Relay This unit is a dedicated two-hand control safety relay under the Guardmaster series of Rockwell Automation. It features dual-channel input, 2 NO safety contacts, Categoría 4 / Performance Level e (pl y) safety rating and removable terminals. Designed specifically for high-risk machinery requiring synchronized two-hand operation, él ...

  • Detalles del producto

Allen‑Bradley Guardmaster MSR125HP (440R‑D23171) Two-Hand Control Safety Relay

This unit is a dedicated two-hand control safety relay under the Guardmaster series of Rockwell Automation. It features dual-channel input, 2 NO safety contacts, Categoría 4 / Performance Level e (pl y) safety rating and removable terminals. Designed specifically for high-risk machinery requiring synchronized two-hand operation, it keeps operators’ hands within safe zones and prevents personal injuries.

  1. Explicación del código del modelo

MSR125HP‑440R‑D23171 is a two-hand control safety relay of the Guardmaster series manufactured by Allen‑Bradley / Automatización Rockwell, EE.UU. The model breakdown and corresponding order number are specified below:

Segmento de códigoDescripción
MSRcódigo de serie: Minotaur Safety Relay
125Function code: Two-hand control unit, compliant with Type III safety requirements of ISO 13851
caballos de fuerzaFeature code: Rendimiento alto, equipped with removable terminals (differentiated from MSR125H with fixed terminals)
440R‑D23171Número de orden: Exclusive Rockwell identification code, for 24V DC power supply and two-hand control function

Key Ordering Information

Main Order Number: 440R‑D23171 (Standard version with removable terminals)

Modelo alternativo: 440R‑D23168 (MSR125H, fixed terminals)

Compatible Model: 440R‑D23172 (with 0.5-second time delay function)

  1. Especificaciones técnicas básicas
CategoríaDatos técnicosObservaciones
Especificaciones generales
TipoTwo-hand control monitoring safety relayCompliant with Type III requirements of ISO 13851
Voltaje de funcionamiento24En DC (-15%/+20%) / 24V y (-15%/+10%)máx.. ripple voltage: 10%
Consumo de energíamáx.. 3W.Low power consumption design
Protección de ingresoIP40 (Alojamiento) / IP20 (Terminales)Suitable for control cabinet installation
Características de entrada
Monitoring ChannelsDual channel (1CAROLINA DEL NORTE + 1NO input)Dedicated for two-hand control, synchronized triggering required
Tipo de entradaDry contact signalCompatible with two-hand control buttons and foot switches
Synchronization Time Window≤ 0.5 segundoOperation beyond this window is deemed unsafe
Características de salida
Contactos de seguridad2 Normalmente abierto (NO) contactosAC15: 230V/6A; DC13: 24V/6A
Salida auxiliarNingunoOptimized for safety control
Nivel de rendimientopl y (Highest level)Compliant with EN ISO 13849‑1
Safety CategoryCategoría 4Compliant with EN IEC 61508
Safety Integrity LevelSIL 3Meets requirements for high-risk applications
Características físicas
Dimensiones22.5mm × 99mm × 121mmMontaje en carril DIN, ahorro de espacio
Montaje35carril DIN estándar mmStandard industrial installation
Temperatura de funcionamiento-25°C ~ 60°CWide temperature range for industrial environments
TerminalesRemovable screw terminalsCable cross-section: 0.25mm² ~ 2.5mm²
CertificacionesUL, CSA, CE, TUVCumple con los estándares internacionales de seguridad.
  1. Cross-Brand Compatibility List
MarcaModelo de reemplazoCompatibility Description
Allen‑BradleyMSR125H (440R‑D23168)Identical functions, only differs in terminal type (fixed terminals)
SchmersalSRB301‑24V (101190686)General-purpose safety relay with 3 contactos de seguridad; two-hand control logic needs reconfiguration
siemens3SK1122‑1AB30Dedicated two-hand control relay, 2 contactos de seguridad, 24En DC
Electricidad SchneiderXPSAC512124VCA/CC, 3 contactos de seguridad; two-hand control requires additional programming
OmrónG9SA‑501Two-hand control unit, 2 contactos de seguridad, DETENER 0 stop category

Consejo de selección: Choose dedicated two-hand control relays; match synchronization window and contact quantity; do not downgrade safety ratings; select terminals according to on-site demands.

  1. Full Model List of MSR Two-Hand Control Series
    ModeloNúmero de ordenVoltajeConfiguración de contactoTipo de terminalFunción especial
    MSR125HP440R‑D2317124VCA/CC2 NO safety contactsRemovableTwo-hand control, salida instantánea
    MSR125H440R‑D2316824VCA/CC2 NO safety contactsFijadoTwo-hand control, salida instantánea
    MSR125HP‑0.5s440R‑D2317224VCA/CC2 NO safety contactsRemovableTwo-hand control, 0.5s delayed output
    MSR125H‑0.5s440R‑D2316924VCA/CC2 NO safety contactsFijadoTwo-hand control, 0.5s delayed output
    MSR125HP‑240V440R‑D23173240V y2 NO safety contactsRemovableTwo-hand control, high voltage version

    Fallos comunes & Solución de problemas

Fenómeno de fallaPosibles causasSoluciones
Indicador de encendido apagado1. Power disconnected or abnormal voltage1. Check power connection and voltage (20.4V~28.8V DC)
2. Internal fuse blown2. Replace 2A internal fuse
Safety contacts fail to activate1. Two buttons not synchronized (interval over 0.5s)1. Standardize operation to ensure synchronized actuation
2. Fault in input channels2. Inspect buttons and wiring, replace defective parts
3. Incorrect reset mode setting3. Verify reset mode (automatic / manual)
Frecuentes disparos en falso1. Interferencia electromagnética1. Apply shielding and keep away from interference sources
2. Loose cable connections2. Retighten cables and ensure reliable connection
3. Improper synchronization window3. Confirm fixed 0.5s synchronization window (no ajustable)
Failed reset1. Safety circuit not fully closed1. Inspect all safety input devices
2. Manual reset button not pressed2. Press reset button (under manual reset mode)
3. Internal component failure3. Replace the safety relay module

Quick Troubleshooting Guide: Check power supply first, then synchronization. For inactive contacts, inspect inputs; for false tripping, eliminate interference; for reset failure, verify the whole safety circuit.

  1. Entornos de aplicación & Casos de la industria

6.1 Escenarios aplicables

Stamping & Bending Machinery: Presses, press brakes, shears and other metalworking equipment requiring two-hand operation

Injection & Molding Machinery: Mold area protection for injection molding machines and die-casting machines to prevent hand injuries

Assembly & Testing Tooling: Custom automated equipment with mandatory two-hand operation for operational safety

Welding & Cutting Equipment: Start-up control for welding robots and plasma cutters to avoid accidental activation

Maquinaria de embalaje: Sealing and cutting stations with synchronized two-hand operation to protect operators

6.2 Escenarios no recomendados

Single-button controlled equipment: Two-hand control function cannot be utilized, resulting in unnecessary cost

Outdoor harsh environments: IP40 rating is not suitable for outdoor installation

Highly corrosive environments: No anti-corrosion coating, incompatible with acid, alkali and corrosive substances

High vibration environments: Vibration exceeding 5g will shorten relay service life

6.3 Casos de aplicación típicos

Caso 1: Two-Hand Start Safety System for CNC Press

Solicitud: Start control for 160-ton CNC press, preventing operators from reaching into the stamping zone

Configuración: MSR125HP (440R‑D23171) + 2 mushroom-head two-hand buttons (mounted on both sides of machine, spacing ≥ 60cm)

Principio de funcionamiento: Both buttons must be pressed synchronously within 0.5 second to close safety contacts and start the press. The machine stops immediately once either button is released.

Efecto: Complies with Category 4 / PL e standards, eliminating risks of hands entering hazardous areas during operation.

Caso 2: Mold Closing Safety Protection for Injection Molding Machine

Solicitud: Mold closing control for 200-ton injection molding machine, preventing pinching injuries during part removal

Configuración: MSR125HP + two-hand buttons (mounted on both sides of control panel) + magnetic safety switch for safety gate

Principio de funcionamiento: Mold closing can only be initiated when the safety gate is fully closed and both buttons are pressed synchronously. Mold movement stops instantly if the gate is opened or any button is released.

Efecto: Dual safety protection implemented, fully compliant with safety standards for rubber and plastics industry.

Caso 3: Two-Hand Coordinated Workstation for Automated Assembly Line

Solicitud: Press-fitting station for automotive component assembly line, two-hand operation required to activate the press head

Configuración: MSR125HP + foot switch (auxiliary control) + two-hand buttons (main control)

Principio de funcionamiento: Activate foot switch to clamp workpieces, then press both buttons synchronously to start the press head, ensuring operators’ hands stay in safe positions.

Efecto: Improves production efficiency while guaranteeing operator safety, ideal for mass production lines.

  1. Pautas de operación & Especificaciones de instalación
  2. Two-hand button installation: Maintain a minimum spacing of 60cm between two buttons to prevent actuation with one single hand.
  3. Wiring rules: Adopt cross wiring for dual input channels to enhance fault detection capability.
  4. Reset mode selection

Reinicio automático: System recovers automatically after fault removal, suitable for continuous production lines.

Reinicio manual: Reset button must be pressed manually, recommended for high-risk applications.

  1. Maintenance schedule: Inspect contact status and wiring every 6 months to ensure stable and safe operation.
  2. Spare parts management: Prepare one identical relay as spare part to minimize downtime caused by equipment failure.