El Chint Contactor NXC18-380V belongs to the Kunlun Series AC contactors, specifically designed for industrial control applications.
- Parámetros técnicos básicos
- Parámetros del circuito principal
Corriente de funcionamiento nominal: 18A (under AC-3 utilization category, corresponding to 380V/400V main circuit voltage).
Tensión nominal de aislamiento: 690V, capable of adapting to voltage fluctuations in complex industrial environments.
Configuración de polos: 3-polo normalmente abierto (NO) contactos principales, supporting three-phase motor control.
Capacidad de ruptura: Rated making current is 180A (10×Es decir), and breaking current is 144A (8×Es decir), meeting the requirements of frequent starting and stopping.
- Parámetros del circuito de control
Voltaje de la bobina: 380V y (50Hz), directly compatible with industrial standard control voltages.
Power Consumption Characteristics: Pull-in power consumption is approximately 40-60VA, and holding power consumption is only 2-7VA, featuring significant energy-saving effects.
Operating Range: Pull-in voltage ranges from 70% a 120% del valor nominal, and release voltage ranges from 20% a 70% del valor nominal, ensuring reliable triggering.
- Configuración de contacto auxiliar
Contactos incorporados: 1 normalmente abierto (NO) + 1 normalmente cerrado (CAROLINA DEL NORTE) contacto auxiliar, enabling extended control logic.
Capacidad de contacto: The rated current of auxiliary contacts is 5A, supporting signal feedback or interlock control.
- Características mecánicas y ambientales
- Diseño Estructural
Método de montaje: Supports 35mm DIN rail clipping or screw fixing, compatible with standardized control cabinet layouts.
Dimensiones y peso: Compact design with dimensions of 88mm×45mm×75mm and a weight of 367g, ahorrando espacio y facilitando el mantenimiento.
Clase de protección: IP20 (protects against intrusion of solid foreign objects larger than 12mm), adecuado para entornos industriales convencionales.
- Adaptabilidad ambiental
Temperatura de funcionamiento: -5℃~+40℃ (a largo plazo), with extreme temperature resistance of -35℃~+70℃, adapting to wide-temperature environments.
Altitude Requirement: ≤2000 metros, meeting the needs of most industrial sites.
Resistencia a vibraciones y golpes: The inclination of the mounting surface is ≤±5°, allowing stable operation in scenarios without significant vibration.
III. Application Scenarios and Supporting Solutions
- Aplicaciones típicas
Control de motores: Directly controls 7.5kW three-phase asynchronous motors (bajo la categoría AC-3), compatible with fan and pump loads.
Sistemas de automatización: Used for production line start-stop control and sequential logic interlocking, supporting PLC integration.
Sistemas de distribución de energía: Combinado con relés de sobrecarga térmica (p.ej., Serie NR2) para formar arrancadores electromagnéticos, proporcionando protección contra sobrecarga.
- Selection and Matching
Fuse Matching: NT00-20 type fuses (gG20) are recommended for short-circuit protection.
Thermal Overload Relay Model: NR2-25/Z, with a rated current adjustment range of 12-18A, accurately matching load characteristics.
- Certifications and Reliability
Certificaciones Internacionales: Certificado por CCC y CE, compliant with GB/T 14048.4/IEC 60947-4-1 estándares, applicable for export projects.
Indicadores de vida útil: vida mecanica de 12 millones de operaciones, electrical life of 1.2 millones de operaciones (bajo AC-3), meeting the requirements of long-term high-load operation.
Material and Technology: Silver alloy contacts have strong arc resistance, and the enhanced spring mechanism ensures rapid contact breaking, reducing the risk of welding.
- Puntos clave de instalación y mantenimiento
- Especificaciones de cableado
Circuito principal: Supports 1.5-6mm² solid wires or 1-4mm² flexible wires, fastened with M3.5 screws (par de apriete: 0.8Nuevo Méjico).
Circuito de control: 1-2.5mm² wires are connected to A1/A2 terminals; shielded wires are recommended for anti-interference.
. Recomendaciones de puesta en servicio
Pull-in Test: Measure the coil resistance before power-on (approximately 1.2kΩ for the 380V specification) to verify coil integrity.
Inspección de contacto: Regularly clean the oxide layer on the contact surface to ensure the contact resistance is ≤50mΩ.
- Alternative Solutions and Upgrade Paths
For function expansion, the following upgrade solutions can be considered:
NXC-22 (22A): Enhanced current capacity, suitable for 11kW motor control.
NXC-25 (25A): Supports DC coil versions, compatible with DC control power supply systems.
Intelligent Contactors: Por ejemplo, NXC-18 paired with the iMCC control module, enabling remote monitoring and energy management.
VII. Caso de aplicación típico
In a certain food processing production line, the NXC18-380V is used to control the conveyor belt motor:
Lógica de control: PLC sends signals to drive the contactor to realize motor forward and reverse switching.
Mecanismo de protección: Combined with the NR2 thermal overload relay, when the motor current exceeds 18A due to stalling, el suministro eléctrico se corta dentro de 0.5 artículos de segunda clase.
Rendimiento de confiabilidad: It has operated continuously for 18 months without faults, with contact wear less than 0.1mm and the maintenance cycle extended by 30%.
VIII. Procurement and Compatibility Recommendations
Selección de canal: Purchase through Chint-authorized distributors (WhatsApp: 0086-13811255435) to ensure the products are accompanied by CCC certification and original factory quality assurance.
Compatibility Verification: Antes de la instalación, check that the coil voltage (380V y) matches the control cabinet power supply to avoid misoperation caused by voltage deviation.
Con su alta rentabilidad y rendimiento estable, the NXC18-380V has become the preferred solution for small and medium-sized motor control, especially suitable for industrial scenarios requiring frequent starting/stopping and high reliability. Al seleccionar el producto, it is necessary to consider load characteristics and environmental conditions; si es necesario, consult Chint technical support to obtain customized solutions.
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor