NXC-65 from the Kunlun Series by CHINT Electric is a 3-pole AC contactor, rated at 65A in the NXC series. The full model is typically expressed as NXC-65 [Voltaje de la bobina] [Frecuencia] (p.ej., NXC-65 220V 50Hz). It is mainly used for frequent starting and control of AC motors, as well as remote making and breaking of ...

  • Detalles del producto

NXC-65 from the Kunlun Series by CHINT Electric is a 3-pole AC contactor, rated at 65A in the NXC series. The full model is typically expressed as NXC-65 [Voltaje de la bobina] [Frecuencia] (p.ej., NXC-65 220V 50Hz). It is mainly used for frequent starting and control of AC motors, as well as remote making and breaking of circuits.

Parámetros eléctricos básicos

ArtículoEspecificaciónDescripción
Rated Operational Current (Es decir)65ARated current of the main circuit
Conventional Thermal Current (Ith)80AMaximum continuous operating current
Tensión operativa nominal (ue)220~690VVoltage range of the main circuit
Número de polos3PAGThree-phase main contact design
Configuración del contacto principal3NO (3 Normalmente abierto)Standard for connecting three-phase power
Contactos auxiliares1NO + 1CAROLINA DEL NORTEBuilt-in 1 NO y 1 CAROLINA DEL NORTE, ampliable
Voltaje de la bobinaAC24V/127V/220V/380V, etc..Multiple voltages available for various control systems
Vida mecánica1,200,000 operacionesMechanical operating cycles
Vida eléctrica100,000 operacionesElectrical cycles under rated load
Applicable StandardsGB/T 14048.1/IEC 60947-1, GB/T 14048.4/IEC 60947-4-1National and international standards

Características del producto

  1. Compact structure: Kunlun series design, tamaño pequeño, low installation space requirement
  2. Alta confiabilidad: Made of high-quality materials with precision manufacturing, adecuado para entornos industriales hostiles
  3. Low power consumption: Low coil power loss, obvious energy-saving effect
  4. Easy installation & maintenance: Montaje en carril DIN estándar de 35 mm, clear terminals for easy operation
  5. Strong expandability: Optional auxiliary contacts, air delay modules and other accessories available
  6. Good safety performance: Excellent arc extinguishing performance and high breaking capacity

Aplicaciones

AC motor control: Frequent start, stop and reversing control for three-phase asynchronous motors up to approx. 30KW

Industrial automation systems: Control of production lines, transportadores, fans, zapatillas, etc..

Electrical control systems: Combined with thermal overload relays to form magnetic starters for motor overload protection

Building electrical: Air conditioning systems, fire equipment, water pump control systems

New energy equipment: Auxiliary control circuits for charging piles, PV inverters, etc..

Partial List of CHINT NXC Series Models

ModeloCorriente nominalConventional Thermal CurrentTypical Motor PowerNotas
NXC-066A10AUp to 2.2kWMinimum rating
NXC-1212A16AUp to 5.5kW
NXC-1818A25AUp to 7.5kW
NXC-2525A32AUp to 11kW
NXC-3232A40AUp to 15kW
NXC-4040A50AUp to 18.5kW
NXC-5050A63AUp to 22kW
NXC-6565A80AUp to 30kW
NXC-8080A100AUp to 37kW
NXC-9595A125AUp to 45kW
NXC-115115A140AUp to 55kW
NXC-150150A175AUp to 75kW

Cross-Brand Comparison (Equivalent AC Contactors)

Below is a comparison between CHINT NXC-65 and equivalent contactors from major brands, all functionally compatible:

CHINTSchneidersiemensTEJIDODeliciosoCompatibilidad
NXC-65LC1D65M7C3RT2036-1AP00A63-30-10CJX2-6511Funcionalmente compatible, slight dimensional differences, mounting may need adjustment

Brand Feature Comparison

MarcaCore StrengthsAplicaciones típicas
CHINTRentable, extensive after-sales networkcontrol industrial general, civil & edificio electrico
SchneiderInternational brand, mature technology, alta confiabilidadHigh-end industrial automation, critical equipment
siemensHigh intelligence, strong communication functionsIndustria 4.0, fabricación inteligente
TEJIDORendimiento alto, robust in harsh environmentsIndustria pesada, nueva energía, tránsito ferroviario
DeliciosoAffordable, high domestic market shareSMEs, civil electrical systems

Important Notes

  1. Ensure the coil voltage matches the control system to avoid malfunction.
  2. Use the contactor with protective devices such as thermal overload relays for motor overload protection.
  3. Para operación de alta frecuencia, select models with longer electrical life or increase maintenance frequency.
  4. Ensure firm wiring of main and control circuits to prevent failures caused by poor contact.

CHINT Contactor Full Series Coding System & Cross-Brand Reference

  1. CHINT Contactor Series Overview & Naming Rules

1.1 Main Series Classification

SeriePosicionamientoRango actualAplicaciones típicas
Serie NXCKunlun, new flagship6~630Acontrol industrial general, motor starting, distribución de energía
Serie NC1Economic basic series9A~95AEquipo pequeño, control de iluminación
Serie NC2Standard industrial series9~630AGeneral industrial & motor control
NC8 SeriesHigh-performance series6A~100AFrequent operation, control de precisión
Serie CJX2Classic predecessor of NXC9A~95ATraditional industrial equipment, motores pequeños
Serie CJ20High-current series10~630AHigh-power motors, heavy-duty equipment
CJ19 SeriesCapacitor switching dedicated16A~100AReactive power compensation, capacitor cabinets
NCH8 SeriesFamiliar / civil use16A~63ASmart home, small appliances
NXJ SeriesMini electromagnetic relay5A~10AControl circuits, signal switching
CKJ SeriesVacuum contactor63~630AHigh-voltage applications, frequent starting

1.2 CHINT Contactor Model Naming Rules

NXC Series Format

NXC □□□ [METRO] [Voltaje de la bobina] [Frecuencia]

│ │ │ │ │

│ │ │ │ └─ Coil frequency (50Hz/60Hz, default 50Hz)

│ │ │ └─ Coil voltage (AC24V/110V/220V/380V or DC24V/110V/220V)

│ │ └─ M = reversing contactor; blank = non-reversing

│ └─ Rated operational current (A)

└─ Brand code + product type (CHINT + contactor de CA)

Auxiliary Contact Marking

Base model: default 1NO + 1CAROLINA DEL NORTE (11)

Extended format: NXC-□□□-[XX], where XX = contact combination (01=0NO1NC, 22=2NO2NC)

Special Function Codes

z: DC-operated contactor

norte: Reversing contactor (NS = horizontal, NC = vertical)

-12: Newer version with improved performance

  1. Complete CHINT Contactor Model List

2.1 Full NXC Series (Kunlun)

ModeloCorriente nominalCorriente térmicaTypical Motor Power (AC-3, 380V)Base Aux. Contactos
NXC-066A10AUp to 2.2kW1NO+1NC
NXC-099A12.5AUp to 3kW1NO+1NC
NXC-1212A16AUp to 5.5kW1NO+1NC
NXC-1818A25AUp to 7.5kW1NO+1NC
NXC-2525A32AUp to 11kW1NO+1NC
NXC-3232A40AUp to 15kW1NO+1NC
NXC-4040A50AUp to 18.5kW1NO+1NC
NXC-5050A63AUp to 22kW1NO+1NC
NXC-6565A80AUp to 30kW1NO+1NC
NXC-8080A100AUp to 37kW1NO+1NC
NXC-9595A125AUp to 45kW1NO+1NC
NXC-115115A140AUp to 55kW1NO+1NC
NXC-150150A175AUp to 75kW1NO+1NC
NXC-185185A210AUp to 90kW1NO+1NC
NXC-225225A250AUp to 110kW1NO+1NC
NXC-265265A300AUp to 132kW1NO+1NC
NXC-300300A350AUp to 160kW1NO+1NC
NXC-370370A400AUp to 200kW1NO+1NC
NXC-400400A450AUp to 220kW1NO+1NC
NXC-500500A560AUp to 250kW1NO+1NC
NXC-630630A700AUp to 315kW1NO+1NC

2.2 Core Models of Other Series

SerieCore ModelsRango actualCaracterísticas clave
NC1NC1-09/12/18/25/32/40

/50/65/80/95

9A~95ACompacto, economical
NC2NC2-09~1509A~150AStandard design, versatile
NC8NC8-06~1006A~100ALow power, long mechanical life
CJX2CJX2-09~959A~95AMounting compatible with Schneider LC1-D
CJ20CJ20-10~63010~630AHigh current carrying capacity
CJ19CJ19-16~10016A~100ASpecial arc quenching for capacitor switching
  1. Cross-Brand Reference for CHINT Contactors

3.1 General Contactor Cross Reference (AC-3, 380V)

CHINTSchneidersiemensTEJIDODeliciosoFunctional Compatibility
NXC-06LC1D0610M5C3RT2015-1AP00A6-30-10CJX2-0610Totalmente compatible, minor dimensional differences
NXC-09LC1D0910M5C3RT2016-1AP00A9-30-10CJX2-0910Totalmente compatible, minor dimensional differences
NXC-12LC1D1210M5C3RT2017-1AP00A12-30-10CJX2-1210Totalmente compatible, minor dimensional differences
NXC-18LC1D1810M5C3RT2026-1AP00A18-30-10CJX2-1810Totalmente compatible, minor dimensional differences
NXC-25LC1D2510M5C3RT2027-1AP00A26-30-10CJX2-2510Totalmente compatible, minor dimensional differences
NXC-32LC1D3210M5C3RT2036-1AP00A30-30-10CJX2-3210Totalmente compatible, minor dimensional differences
NXC-40LC1D4010M5C3RT2037-1AP00A40-30-10CJX2-4010Totalmente compatible, minor dimensional differences
NXC-50LC1D5010M5C3RT2040-1AP00A50-30-10CJX2-5010Totalmente compatible, minor dimensional differences
NXC-65LC1D6510M5C3RT2046-1AP00A63-30-10CJX2-6510Totalmente compatible, minor dimensional differences
NXC-80LC1D8010M5C3RT2056-1AP00A75-30-10CJX2-8010Totalmente compatible, minor dimensional differences
NXC-95LC1D9510M5C3RT2066-1AP00A95-30-10CJX2-9510Totalmente compatible, minor dimensional differences
NXC-115LC1D11510M5C3RT2076-1AP00A110-30-10CJX2-11510Generally compatible, mounting may need adjustment
NXC-150LC1D15010M5C3RT2086-1AP00A145-30-10CJX2-15010Generally compatible, mounting may need adjustment

3.2 Brand Technical Comparison

MarcaCaracterísticas técnicasStrengthsPrice Position
CHINTModular Kunlun design, low-power coil, long-life contactsGeneral industry, building electricsMid-low, rentable
SchneiderTeSys series, intelligent control, rich communicationHigh-end automation, critical loadsMid-high, leading tech
siemens3RT series, alta confiabilidad, integrated protectionIndustria 4.0, smart manufacturingAlto, stable
TEJIDOModular, high noise immunity, eco-friendly materialsIndustria pesada, nueva energía, transitAlto, premium performance
DeliciosoCJX2 compatible with CHINTSMEs, civil installationsBajo, affordable
  1. Selección & Pautas de reemplazo

4.1 Key Selection Parameters

  1. Corriente nominal (Es decir): Select according to load; for motors, Ie ≥ 1.2 × motor rated current.
  2. voltaje de la bobina: Must match control system (AC/DC no intercambiables).
  3. Operating frequency: Para >1200 operaciones/hora, use long-life models.
  4. Contactos auxiliares: Choose based on control logic (default 1NO+1NC).
  5. Montaje: Carril DIN estándar de 35 mm; high-current models may use bolt mounting.

4.2 Cross-Brand Replacement Notes

  1. Mechanical compatibility

NXC mostly compatible with Schneider LC1-D mounting, but hole positions differ slightly.

Models above 100A vary greatly; brackets may need modification.

  1. Electrical compatibility

Coil voltage and frequency must match exactly.

Auxiliary contact ratings differ (CHINT ~5A, some Schneider ~10A).

Short-circuit coordination with fuses/circuit breakers should be rechecked.

  1. Performance differences

NXC: mechanical life 1.2 millón, electrical life 100,000 (AC-3).

Premium Schneider/Siemens models reach 200,000 electrical cycles for ultra-frequent use.

4.3 NXC vs CJX2 Replacement

CHINT CJX2Equivalent NXCUpgrade Benefits
CJX2-09NXC-09Smaller, lower power, longer life
CJX2-12NXC-12Smaller, lower power, longer life
CJX2-18NXC-18Smaller, lower power, longer life
CJX2-25NXC-25Smaller, lower power, longer life
CJX2-32NXC-32Smaller, lower power, longer life
CJX2-40NXC-40Smaller, lower power, longer life
CJX2-50NXC-50Smaller, lower power, longer life
CJX2-65NXC-65Smaller, lower power, longer life
CJX2-80NXC-80Smaller, lower power, longer life
CJX2-95NXC-95Smaller, lower power, longer life
  1. Quick Motor Selection Table
Potencia del motor (KW)Corriente nominal (A)Recommended CHINTSchneidersiemensTEJIDO
2.25NXC-06LC1D06103RT2015A6-30-10
36.5NXC-09LC1D09103RT2016A9-30-10
5.512NXC-12LC1D12103RT2017A12-30-10
7.516NXC-18LC1D18103RT2026A18-30-10
1123NXC-25LC1D25103RT2027A26-30-10
1532NXC-32LC1D32103RT2036A30-30-10
18.539NXC-40LC1D40103RT2037A40-30-10
2247NXC-50LC1D50103RT2040A50-30-10
3063NXC-65LC1D65103RT2046A63-30-10
3778NXC-80LC1D80103RT2056A75-30-10
4594NXC-95LC1D95103RT2066A95-30-10

CHINT contactors cover a full range from 6A to 630A. The NXC (Kunlun) series offers greatly improved performance, reliability and compatibility, and can directly replace the CJX2 series and equivalent products from other brands. Para reemplazo entre marcas, verify rated current, voltaje de la bobina, mounting dimensions and auxiliary contact configuration to ensure stable system operation.